  • Assembly of UV-Ozone Reactor to Combat of Coronavirus and Other Pathogenic Microorganisms

    by Emerson Roberto Santos, Juliana Aparecida Vendrami, Antonio Celso Duarte, Elvo Calixto Burini Júnior, Roberto Koji Onmori, Wang Shu Hui

    The contamination on the surface of objects caused by: fungi, microbes, bacteria and viruses (and also coronavirus) can be solved using UV rays and/or ozone gas. For this reason, a UV-Ozone reactor apparatus with low cost was mounted to test two different types of HID (high intensity discharge) lamps: high pressure mercury vapor lamp (HPMVL) and metal halide lamp (MHL), both with nominal power of 400 watts and E-40 (base, screw) were studied as possible method of disinfection. Each lamp used the respective electromagnetic ballasts and both were manufactured by Osram Company. These lamps have two bulb types: the outer bulb which was removed and it is responsible for filtering the ultraviolet wavelengths and the internal bulb (where there is mercury, argon or metal halide confined at high pressure) that is the main source of ultraviolet rays. The complete apparatus was assembled using: aluminum reflector (used as a chamber), two microcomputer fans and a wooden base covered by an aluminum foil. A rubber strip was placed at the edge of the reflector for better adhesion on the aluminum foil (for better confinement ozone gas). The ozone concentration inside the reactor was measured with a monitor, the temperatures were measured near lamps with a thermocouple and a spectroradiometer with optical fiber was used to obtain the wavelengths. The results revealed to the elapsed time of 2 minutes a maximum peak of ozone concentration of 23 ppm for LVMAP, while the MHL presented 4.5 ppm only. The temperature obtained by HPMVL was lower with 31.5 ºC, while the MHL presented 48.0 ºC. The HPMVL presented higher amount of wavelengths at the ranges: UV-A, UV-B and UV-C, while the MHL presented only UV-A. For these reasons, it is suggested to be most promissory the use of HPMVL to combat the coronavirus and other pathogenic microorganisms.


  • Open Access

    Temperature analysis of driver and optical behavior of LED lamps

    by Emerson Roberto Santos, Maurício Vicente Tavares, Antonio Celso Duarte, Hélio Akira Furuya

    This exploratory study was carried out with the objective to know the optical behavior of light-emitting diode (LED) lamps used and the temperature reached by electronic components that compose the driver (electronic circuit situated inside the body LED lamp) responsible to convert electrical alternating current from power line to direct current to operate the LED devices. Then, two different experiments were carried out with LED lamps. In the first experiment, 131 LED lamps used were chosen randomly and bought from household appliances store (bargain market product) presenting different nominal powers, 8, 10, 12 and 15 watts. All LED lamps were polarized at the power line at 127 V and revealed different optical behaviors, such as: not turn-on; flashing light (as strobe effect); flashing light (as strobe effect) with high intensity (more intense than normal); flashing light (as strobe effect) with low intensity (less intense than normal); fast turnon and turn-off only; and turn-on with low intensity of light (less intense than normal). The hypothesis for these behaviors can be attributed by three different behaviors: in lamps not turn-on, this failure can be attributed for dark spots that are created on the surface of LED device. In these lamps, all LED devices are electrically connected in serial. When a LED is inoperative, the electrical current is interrupted for all LED devices; damage to the electronic components caused by internal high temperature confined inside the lamp body during the operation causing electrical oscillations, as observed from different behaviors from flashing light, flashing light with high intensity, flashing light with low intensity and fast turn-on and turn-off only; swelling of the electrolytic capacitors causing low energy storage and varying the electrical current flow, the electrical current for other electronic components altered the normal optical behavior of the LED lamps. In the second experiment, the temperatures of electronic components located in driver were obtained out of body lamp revealing: from 33 (lowest temperature attributed to inductor) to 52.5ºC (highest temperature attributed to electrolytic capacitor). These temperature values represent the ideal or normal condition of operation for electronic components, but, when they are operating inside the lamp body, the found temperature values increased considerably. This characteristic can be better evidenced by strong color change (caused by accumulative temperature during the elapsed days used) on the printed circuit board used in the driver.

  • Open Access

    Assembly of UV-Ozone Reactor to Combat of Coronavirus and Other Pathogenic Microorganisms

    by Emerson Roberto Santos, Juliana Aparecida Vendrami, Antonio Celso Duarte, Elvo Calixto Burini Júnior, Roberto Koji Onmori, Wang Shu Hui

    The contamination on the surface of objects caused by: fungi, microbes, bacteria and viruses (and also coronavirus) can be solved using UV rays and/or ozone gas. For this reason, a UV-Ozone reactor apparatus with low cost was mounted to test two different types of HID (high intensity discharge) lamps: high pressure mercury vapor lamp (HPMVL) and metal halide lamp (MHL), both with nominal power of 400 watts and E-40 (base, screw) were studied as possible method of disinfection. Each lamp used the respective electromagnetic ballasts and both were manufactured by Osram Company. These lamps have two bulb types: the outer bulb which was removed and it is responsible for filtering the ultraviolet wavelengths and the internal bulb (where there is mercury, argon or metal halide confined at high pressure) that is the main source of ultraviolet rays. The complete apparatus was assembled using: aluminum reflector (used as a chamber), two microcomputer fans and a wooden base covered by an aluminum foil. A rubber strip was placed at the edge of the reflector for better adhesion on the aluminum foil (for better confinement ozone gas). The ozone concentration inside the reactor was measured with a monitor, the temperatures were measured near lamps with a thermocouple and a spectroradiometer with optical fiber was used to obtain the wavelengths. The results revealed to the elapsed time of 2 minutes a maximum peak of ozone concentration of 23 ppm for LVMAP, while the MHL presented 4.5 ppm only. The temperature obtained by HPMVL was lower with 31.5 ºC, while the MHL presented 48.0 ºC. The HPMVL presented higher amount of wavelengths at the ranges: UV-A, UV-B and UV-C, while the MHL presented only UV-A. For these reasons, it is suggested to be most promissory the use of HPMVL to combat the coronavirus and other pathogenic microorganisms.


  • Open Access

    INOVAÇÃO ABERTA NAS INCUBADORAS: REVISÃO INTEGRATIVA DA LITERATURA

    by Antonio Celso Duarte, Napoleão Verardi Galegale

    INOVAÇÃO ABERTA NAS INCUBADORAS: REVISÃO INTEGRATIVA DA LITERATURA

  • Open Access

    Aplicação do Modelo Squad Health Check em times ágeis de uma instituição financeira

    by Klauren Godoi Araújo Camargo, Felipe Neves, Antonio Celso Duarte, Napoleão Verardi Galegale, Marcelo Duduchi

    Neste trabalho foram discutidos por meio de uma abordagem qualitativa, instrumentos de aferição de maturidade no desenvolvimento de software com uso de Scrum aplicados a 17 times de uma instituição financeira de economia mista. A prática de medição de maturidade já se faz presente mesmo em times que utilizam método tradicional de desenvolvimento, com utilização de modelos como CMMI – Capability Maturity Model Integration e ISO/IEC 15504 dentre outros, mas que se mostram bastante lineares em seus níveis. Assim, a empresa analisada optou por experimentar a utilização de um modelo mais informal e mais leve para obter de forma holística a percepção de seus times em relação a quatro dimensões: cultura, desafios organizacionais, técnicos e insights recebidos de clientes e usuários, para evidenciar necessidades de melhoria e posterior proposição de planos de ação. O objetivo desse trabalho é analisar a aplicação do Squad Health Check Model (SHCM) em uma instituição financeira de grande porte e que utiliza o método Scrum para desenvolvimento ágil de produtos digitais. Nesse artigo são abordadas a natureza do SHCM, etapas e sua aplicação em um contexto específico. Os resultados apresentados baseiam-se no compilado de percepções dos 17 times ágeis que aplicaram o Squad Health Check Model proposto pelo Spotify o que permitiu verificar que a utilização do modelo proposto por analistas do Spotify pode ser adaptada à realidade das empresas brasileiras pois apresentou resultados assertivos. Falhas e dificuldades estruturais foram evidenciadas pelo modelo que puderam ser constatadas ao se analisar os processos internos da instituição.