EJElvo Calixto Burini Junior

Elvo Calixto Burini Junior

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Elvo Calixto Burini Junior has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Revitalização da Iluminação na CUASO: premissas

    by Elvo Calixto Burini Junior, Universidade de São Paulo, José Carlos Martinez Melero, Leonardo Brian Favato, Rafael Ferri, Hédio Tatizawa

  • Open Access

    Sistemas de iluminação pública: polímeros utilizados e depreciação luminosa (L70)

    by José Carlos Martinez Melero, Universidade de São Paulo., Elvo Calixto Burini Junior, Emerson Roberto Santos, Hédio Tatizawa

    Os materiais à base de polímeros foram identificados como componentes em um sistema de iluminação pública viária. Está presente em lentes (policarbonato e silicone), encapsulamento e vedação (poliéster, silicone) para proteção dos usuários, conexões e circuitos elétricos/eletrônicos. A queda na eficiência luminosa e a falha abrupta de um ponto de luz podem estar associadas a alteração na estrutura de um polímero utilizado. Alguns polímeros utilizados em sistemas de iluminação pública foram identificados. O desempenho de material polimérico utilizado em luminárias e componentes da iluminação conduziu a um modo de falha não usual, perda da rigidez estrutural/mecânica, que pode estar relacionado a fatores externos (radiação infravermelha e/ou ultravioleta e umidade), a qualidade do polímero utilizado, traduzida pela ausência de agente para a estabilização do polímero. O modo de falha por perda de estanqueidade nos equipamentos avaliados está indicado, a utilização de polímeros foi investigada e discutida. Em relação à vida útil, os equipamentos LED da Universidade de São Paulo têm apresentado alto índice de falhas abruptas, saída de luz com depreciação estimada de 70 % alcançada aos 10 anos (44 kh) de utilização, antes de atingir o valor nominal prescrito pelo fornecedor de 65 kh (L70).

  • Assembly of UV-Ozone Reactor to Combat of Coronavirus and Other Pathogenic Microorganisms

    by Emerson Roberto Santos, Juliana Aparecida Vendrami, Antonio Celso Duarte, Elvo Calixto Burini Júnior, Roberto Koji Onmori, Wang Shu Hui

    The contamination on the surface of objects caused by: fungi, microbes, bacteria and viruses (and also coronavirus) can be solved using UV rays and/or ozone gas. For this reason, a UV-Ozone reactor apparatus with low cost was mounted to test two different types of HID (high intensity discharge) lamps: high pressure mercury vapor lamp (HPMVL) and metal halide lamp (MHL), both with nominal power of 400 watts and E-40 (base, screw) were studied as possible method of disinfection. Each lamp used the respective electromagnetic ballasts and both were manufactured by Osram Company. These lamps have two bulb types: the outer bulb which was removed and it is responsible for filtering the ultraviolet wavelengths and the internal bulb (where there is mercury, argon or metal halide confined at high pressure) that is the main source of ultraviolet rays. The complete apparatus was assembled using: aluminum reflector (used as a chamber), two microcomputer fans and a wooden base covered by an aluminum foil. A rubber strip was placed at the edge of the reflector for better adhesion on the aluminum foil (for better confinement ozone gas). The ozone concentration inside the reactor was measured with a monitor, the temperatures were measured near lamps with a thermocouple and a spectroradiometer with optical fiber was used to obtain the wavelengths. The results revealed to the elapsed time of 2 minutes a maximum peak of ozone concentration of 23 ppm for LVMAP, while the MHL presented 4.5 ppm only. The temperature obtained by HPMVL was lower with 31.5 ºC, while the MHL presented 48.0 ºC. The HPMVL presented higher amount of wavelengths at the ranges: UV-A, UV-B and UV-C, while the MHL presented only UV-A. For these reasons, it is suggested to be most promissory the use of HPMVL to combat the coronavirus and other pathogenic microorganisms.


  • Open Access

    Assembly of UV-Ozone Reactor to Combat of Coronavirus and Other Pathogenic Microorganisms

    by Emerson Roberto Santos, Juliana Aparecida Vendrami, Antonio Celso Duarte, Elvo Calixto Burini Júnior, Roberto Koji Onmori, Wang Shu Hui

    The contamination on the surface of objects caused by: fungi, microbes, bacteria and viruses (and also coronavirus) can be solved using UV rays and/or ozone gas. For this reason, a UV-Ozone reactor apparatus with low cost was mounted to test two different types of HID (high intensity discharge) lamps: high pressure mercury vapor lamp (HPMVL) and metal halide lamp (MHL), both with nominal power of 400 watts and E-40 (base, screw) were studied as possible method of disinfection. Each lamp used the respective electromagnetic ballasts and both were manufactured by Osram Company. These lamps have two bulb types: the outer bulb which was removed and it is responsible for filtering the ultraviolet wavelengths and the internal bulb (where there is mercury, argon or metal halide confined at high pressure) that is the main source of ultraviolet rays. The complete apparatus was assembled using: aluminum reflector (used as a chamber), two microcomputer fans and a wooden base covered by an aluminum foil. A rubber strip was placed at the edge of the reflector for better adhesion on the aluminum foil (for better confinement ozone gas). The ozone concentration inside the reactor was measured with a monitor, the temperatures were measured near lamps with a thermocouple and a spectroradiometer with optical fiber was used to obtain the wavelengths. The results revealed to the elapsed time of 2 minutes a maximum peak of ozone concentration of 23 ppm for LVMAP, while the MHL presented 4.5 ppm only. The temperature obtained by HPMVL was lower with 31.5 ºC, while the MHL presented 48.0 ºC. The HPMVL presented higher amount of wavelengths at the ranges: UV-A, UV-B and UV-C, while the MHL presented only UV-A. For these reasons, it is suggested to be most promissory the use of HPMVL to combat the coronavirus and other pathogenic microorganisms.


  • Open Access

    Low cost spinner developed for deposition of thin films used in OLED devices

    by Emerson Roberto Santos, Christine Miwa Takahashi, Herick Garcia Takimoto, Satoru Yoshida, Mariane Tsubaki Oide, Elvo Calixto Burini Junior, Roberto Koji Onmori, Wang Shu Hui

    This work aims the development of a compact spinner to be used inside the glove-box chamber to deposition of polymeric thin films used in the build of OLED devices. Initially, ten fans extracted of microcomputers were tested with commercial multi-voltage power supply. Four fans were selected based on the standard deviation of speed. A variable power supply was also built in order to get a more detailed response in terms of electrical current and speed in function of applied voltage. The fan that showed less variation of speed with applied voltage was selected for deposition tests using polymeric photoresist solution on the ITO (indium tin oxide) coated glass. This polymer was deposited by spin-coating at different speeds: 1000, 2000, 3000 and 4000 rpm and dried for the thicknesses measurement revealing good uniformity. Finally, three OLED devices were assembled with 2000 and 3000 rpm and the layers were dried under the same conditions. In the structure of the devices were used the materials deposited layer-by-layer:glass/ITO/PEDOT:PSS/ Polyfluorene (PFpf)/Al. The OLED devices revealed blue light electroluminescence. The I-V curves showed better performance for OLED devices mounted at 2000 rpm with higher current density and similar appearance to the diode curve.