Jiayuan Peng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jiayuan Peng has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
Bin Cai
Department of Radiation Oncology's Division of Medical Physics & Engineering, University of Texas Southwestern Medical Center, Dallas, TX, USA
3 shared publications- Bin Cai
Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
2 shared publications - Jiazhou Wang
Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, 200032, China; Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, 200032, China; Shanghai Clinical Research Center for Radiation Oncology, China; Shanghai Key Laboratory of Article Radiation Oncology, Shanghai, 200032, China
2 shared publications Sasa Mutic
Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri
2 shared publicationsThomas R Mazur
Washington University
2 shared publications- Weigang Hu
Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, 200032, China; Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, 200032, China; Shanghai Clinical Research Center for Radiation Oncology, China; Shanghai Key Laboratory of Article Radiation Oncology, Shanghai, 200032, China
2 shared publications
Latest Publications
- Open Access
- 10 April 2026
- Published by Elsevier in Photoacoustics
- Vol. 49, 100826
Limited-view signal recovery with frequency-aware denoising diffusion and geometry-integrated masked autoencoders for X-ray acoustic computed tomography
- 10 April 2026
- Published by Elsevier in Photoacoustics
- Vol. 49, 100826
Open AccessLimited-view signal recovery with frequency-aware denoising diffusion and geometry-integrated masked autoencoders for X-ray acoustic computed tomography
- 24 November 2022
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 231, 107263
Toward real-time automatic treatment planning (RTTP) with a one-step 3D fluence map prediction method and (nonorthogonal) convolution technique
- 24 November 2022
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 231, 107263
Toward real-time automatic treatment planning (RTTP) with a one-step 3D fluence map prediction method and (nonorthogonal) convolution technique
- 23 July 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (15) , 155011
An atlas-guided automatic planning approach for rectal cancer intensity-modulated radiotherapy
We try to develop an atlas-guided automatic planning (AGAP) approach and evaluate its feasibility and performance in rectal cancer intensity-modulated radiotherapy. The developed AGAP approach consisted of four independent modules: patient atlas, similar patient retrieval, beam morphing (BM), and plan fine-tuning (PFT) modules. The atlas was setup using anatomy and plan data from Pinnacle auto-planning (P-auto) plans. Given a new patient, the retrieval function searched the top similar patient by a generic Fourier descriptor algorithm and retrieved its plan information. The BM function generated an initial plan for the new patient by morphing the beam aperture from the top similar patient plan. The beam aperture and calculated dose of the initial plan were used to guide the new plan optimization in the PFT function. The AGAP approach was tested on 96 patients by the leave-one-out validation and plan quality was compared with the P-auto plans. The AGAP and P-auto plans had no statistical difference for target coverage and dose homogeneity in terms of V 100% ( p = 0.76) and homogeneity index ( p = 0.073), respectively. The CI index showed they had a statistically significant difference. But the ΔCI was both 0.02 compared to the perfect CI index of 1. The AGAP approach reduced the bladder mean dose by 152.1 cGy ( p < 0.05) and V 50 by 0.9% ( p < 0.05), and slightly increased the left and right femoral head mean dose by 70.1 cGy ( p < 0.05) and 69.7 cGy ( p < 0.05), respectively. This work developed an efficient and automatic approach that could fully automate the IMRT planning process in rectal cancer radiotherapy. It reduced the plan quality dependence on the planner experience and maintained the comparable plan quality with P-auto plans.
- 23 July 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (15) , 155011
An atlas-guided automatic planning approach for rectal cancer intensity-modulated radiotherapy
We try to develop an atlas-guided automatic planning (AGAP) approach and evaluate its feasibility and performance in rectal cancer intensity-modulated radiotherapy. The developed AGAP approach consisted of four independent modules: patient atlas, similar patient retrieval, beam morphing (BM), and plan fine-tuning (PFT) modules. The atlas was setup using anatomy and plan data from Pinnacle auto-planning (P-auto) plans. Given a new patient, the retrieval function searched the top similar patient by a generic Fourier descriptor algorithm and retrieved its plan information. The BM function generated an initial plan for the new patient by morphing the beam aperture from the top similar patient plan. The beam aperture and calculated dose of the initial plan were used to guide the new plan optimization in the PFT function. The AGAP approach was tested on 96 patients by the leave-one-out validation and plan quality was compared with the P-auto plans. The AGAP and P-auto plans had no statistical difference for target coverage and dose homogeneity in terms of V 100% ( p = 0.76) and homogeneity index ( p = 0.073), respectively. The CI index showed they had a statistically significant difference. But the ΔCI was both 0.02 compared to the perfect CI index of 1. The AGAP approach reduced the bladder mean dose by 152.1 cGy ( p < 0.05) and V 50 by 0.9% ( p < 0.05), and slightly increased the left and right femoral head mean dose by 70.1 cGy ( p < 0.05) and 69.7 cGy ( p < 0.05), respectively. This work developed an efficient and automatic approach that could fully automate the IMRT planning process in rectal cancer radiotherapy. It reduced the plan quality dependence on the planner experience and maintained the comparable plan quality with P-auto plans.
- Open Access
- 1 May 2020
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 5 (3) , 482-489
Intracranial Stereotactic Radiation Therapy With a Jawless Ring Gantry Linear Accelerator Equipped With New Dual Layer Multileaf Collimator
- 1 May 2020
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 5 (3) , 482-489
Open AccessIntracranial Stereotactic Radiation Therapy With a Jawless Ring Gantry Linear Accelerator Equipped With New Dual Layer Multileaf Collimator
- 1 January 2020
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 6 (1) , 015025
Long-term Inter-protocol kV CBCT image quality assessment for a ring-gantry linac via automated QA approach
We develop a fully automated QA process to compare the image quality of all kV CBCT protocols on a Halcyon linac with ring gantry design, and evaluate image quality stability over a 10-month period. A total of 19 imaging scan and reconstruction protocols were characterized with measurement on a newly released QUART phantom. A set of image analysis algorithms were developed and integrated into an automated analysis suite to derive key image quality metrics, including HU value accuracy on density inserts, HU uniformity using the background plate, high contrast resolution with the modulation transfer function (MTF) from the edge profiles, low contrast resolution using the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), slice thickness with the air gap modules, and geometric accuracy with the diameter of the phantom. Image quality data over 10 months was tracked and analyzed to evaluate the stability of the Halcyon kV imaging system. The HU accuracy over all 19 protocols is within tolerance (±50HU). The maximum uniformity deviation is 12.2 HU. The SNR and CNR, depending on the protocol selected, range from 18.5–911.9 and 1.9–102.8, respectively. A much-improved SNR and CNR were observed for iterative reconstruction (iCBCT) modes and protocols designed for large subjects over low dose and fast scanning modes. The Head and Image Gently protocols have the greatest high contrast resolution with MTF 10% over 1 lp/mm and MTF 50% over 0.6 lp/mm. The iCBCT mode slightly improved the MTF 10% and MTF 50% compared to the Feldkamp-Davis-Kress approach. The slice thickness (maximum error of 0.31 mm) and geometry metrics (maximum error of 0.7 mm) are all within tolerance (±0.5 mm for slice thickness and ±1 mm for geometry metrics). The long-term study over 10-month showed no significant drift for all key image quality metrics, which indicated the kV CBCT image quality is stable over time.
- 1 January 2020
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 6 (1) , 015025
Long-term Inter-protocol kV CBCT image quality assessment for a ring-gantry linac via automated QA approach
We develop a fully automated QA process to compare the image quality of all kV CBCT protocols on a Halcyon linac with ring gantry design, and evaluate image quality stability over a 10-month period. A total of 19 imaging scan and reconstruction protocols were characterized with measurement on a newly released QUART phantom. A set of image analysis algorithms were developed and integrated into an automated analysis suite to derive key image quality metrics, including HU value accuracy on density inserts, HU uniformity using the background plate, high contrast resolution with the modulation transfer function (MTF) from the edge profiles, low contrast resolution using the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), slice thickness with the air gap modules, and geometric accuracy with the diameter of the phantom. Image quality data over 10 months was tracked and analyzed to evaluate the stability of the Halcyon kV imaging system. The HU accuracy over all 19 protocols is within tolerance (±50HU). The maximum uniformity deviation is 12.2 HU. The SNR and CNR, depending on the protocol selected, range from 18.5–911.9 and 1.9–102.8, respectively. A much-improved SNR and CNR were observed for iterative reconstruction (iCBCT) modes and protocols designed for large subjects over low dose and fast scanning modes. The Head and Image Gently protocols have the greatest high contrast resolution with MTF 10% over 1 lp/mm and MTF 50% over 0.6 lp/mm. The iCBCT mode slightly improved the MTF 10% and MTF 50% compared to the Feldkamp-Davis-Kress approach. The slice thickness (maximum error of 0.31 mm) and geometry metrics (maximum error of 0.7 mm) are all within tolerance (±0.5 mm for slice thickness and ±1 mm for geometry metrics). The long-term study over 10-month showed no significant drift for all key image quality metrics, which indicated the kV CBCT image quality is stable over time.
- Open Access
- 8 May 2016
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 17 (3) , 147-157
Are simple IMRT beams more robust against MLC error? Exploring the impact of MLC errors on planar quality assurance and plan quality for different complexity beams
This study investigated the impact of beam complexities on planar quality assurance and plan quality robustness by introducing MLC errors in intensity‐modulate radiation therapy. Forty patients' planar quality assurance (QA) plans were enrolled in this study, including 20 dynamic MLC (DMLC) IMRT plans and 20 static MLC (SMLC) IMRT plans. The total beam numbers were 150 and 160 for DMLC and SMLC, respectively. Six different magnitudes of MLC errors were introduced to these beams. Gamma pass rates were calculated by comparing error‐free fluence and error‐induced fluence. The plan quality variation was acquired by comparing PTV coverage. Eight complexity scores were calculated based on the beam fluence and the MLC sequence. The complexity scores include fractal dimension, monitor unit, modulation index, fluence map complexity, weighted average of field area, weighted average of field perimeter, and small aperture ratio . The Spearman's rank correlation coefficient was calculated to analyze the correlation between these scores and gamma pass rate and plan quality variation. For planar QA, the most significant complexity index was fractal dimension for DMLC and weighted segment area for SMLC at low magnitude MLC error. For plan quality, the most significant complexity index was weighted segment perimeter for DMLC and weighted segment area for SMLC at low magnitude MLC error. The sensitivity of planar QA was weakly associated with the field complexity with low magnitude MLC error, but the plan quality robustness was associated with beam complexity. Plans with simple beams were more robust to MLC error.PACS number(s): 87.55
- 8 May 2016
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 17 (3) , 147-157
Open AccessAre simple IMRT beams more robust against MLC error? Exploring the impact of MLC errors on planar quality assurance and plan quality for different complexity beams
This study investigated the impact of beam complexities on planar quality assurance and plan quality robustness by introducing MLC errors in intensity‐modulate radiation therapy. Forty patients' planar quality assurance (QA) plans were enrolled in this study, including 20 dynamic MLC (DMLC) IMRT plans and 20 static MLC (SMLC) IMRT plans. The total beam numbers were 150 and 160 for DMLC and SMLC, respectively. Six different magnitudes of MLC errors were introduced to these beams. Gamma pass rates were calculated by comparing error‐free fluence and error‐induced fluence. The plan quality variation was acquired by comparing PTV coverage. Eight complexity scores were calculated based on the beam fluence and the MLC sequence. The complexity scores include fractal dimension, monitor unit, modulation index, fluence map complexity, weighted average of field area, weighted average of field perimeter, and small aperture ratio . The Spearman's rank correlation coefficient was calculated to analyze the correlation between these scores and gamma pass rate and plan quality variation. For planar QA, the most significant complexity index was fractal dimension for DMLC and weighted segment area for SMLC at low magnitude MLC error. For plan quality, the most significant complexity index was weighted segment perimeter for DMLC and weighted segment area for SMLC at low magnitude MLC error. The sensitivity of planar QA was weakly associated with the field complexity with low magnitude MLC error, but the plan quality robustness was associated with beam complexity. Plans with simple beams were more robust to MLC error.PACS number(s): 87.55
- Open Access
- 5 September 2014
- Published by Spandidos Publications in Molecular Medicine Reports
- Vol. 10 (5) , 2720-2728
Knockdown of Y-box-binding protein-1 inhibits the malignant progression of HT-29 colorectal adenocarcinoma cells by reversing epithelial-mesenchymal transition
Y‑box binding protein‑1 (YB‑1) has been identified as an oncoprotein in various malignancies. The aim of this study was to investigate the biological role of YB‑1 and its association with epithelial‑to‑mesenchymal transition (EMT) in colorectal cancer (CRC). The expression of YB‑1 and three EMT‑related proteins (E‑cadherin, N‑cadherin and vimentin) was analyzed in 80 CRC and matched normal tissue samples, by immunohistochemistry. The results indicated that the expression of YB‑1 was higher in CRC tissue samples than that in matched normal controls and was significantly correlated with tumor differentiation, tumor invasion, lymph node metastasis and distant metastases. Furthermore, analysis showed that YB‑1 expression was negatively correlated with E‑cadherin and positively correlated with N‑cadherin and vimentin expression. In vitro assays showed that knockdown of YB‑1 inhibited the proliferation, apoptosis resistance, invasion and migration of the HT‑29 CRC cell line. Of note, following knockdown of YB‑1, E‑cadherin expression was elevated whereas N‑cadherin and vimentin expression was reduced. Taken together, these results suggest that YB‑1 promotes the malignant progression of CRC in part through the induction of EMT, and YB‑1 may therefore be a potential novel target for CRC treatment.
- 5 September 2014
- Published by Spandidos Publications in Molecular Medicine Reports
- Vol. 10 (5) , 2720-2728
Open AccessKnockdown of Y-box-binding protein-1 inhibits the malignant progression of HT-29 colorectal adenocarcinoma cells by reversing epithelial-mesenchymal transition
Y‑box binding protein‑1 (YB‑1) has been identified as an oncoprotein in various malignancies. The aim of this study was to investigate the biological role of YB‑1 and its association with epithelial‑to‑mesenchymal transition (EMT) in colorectal cancer (CRC). The expression of YB‑1 and three EMT‑related proteins (E‑cadherin, N‑cadherin and vimentin) was analyzed in 80 CRC and matched normal tissue samples, by immunohistochemistry. The results indicated that the expression of YB‑1 was higher in CRC tissue samples than that in matched normal controls and was significantly correlated with tumor differentiation, tumor invasion, lymph node metastasis and distant metastases. Furthermore, analysis showed that YB‑1 expression was negatively correlated with E‑cadherin and positively correlated with N‑cadherin and vimentin expression. In vitro assays showed that knockdown of YB‑1 inhibited the proliferation, apoptosis resistance, invasion and migration of the HT‑29 CRC cell line. Of note, following knockdown of YB‑1, E‑cadherin expression was elevated whereas N‑cadherin and vimentin expression was reduced. Taken together, these results suggest that YB‑1 promotes the malignant progression of CRC in part through the induction of EMT, and YB‑1 may therefore be a potential novel target for CRC treatment.
- Open Access
- 1 September 2014
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 90 (1) , S201
Patient Features–Based Dosimetric Pareto Front Prediction in Esophagus Cancer Radiation Therapy
- 1 September 2014
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 90 (1) , S201
Open AccessPatient Features–Based Dosimetric Pareto Front Prediction in Esophagus Cancer Radiation Therapy
- 5 May 2010
- Published by Elsevier in Medical Hypotheses
- Vol. 75 (5) , 442-444
Tumor stroma: A determinant role in local recurrence of rectal cancer patients receiving total mesorectal excision?
- 5 May 2010
- Published by Elsevier in Medical Hypotheses
- Vol. 75 (5) , 442-444
Tumor stroma: A determinant role in local recurrence of rectal cancer patients receiving total mesorectal excision?