Bo Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bo Zhou has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Hui Li
School of Architecture and Civil Engineering, Shenyang University of Technology
3 shared publications - Wen Xin
School of Mechanical Engineering, Shenyang University of Technology, Shenyang 110870, China
2 shared publications - Xiaolong Lu
School of Architecture and Civil Engineering, Shenyang University of Technology, Shenyang 110870, China
2 shared publications - Baokuan Ning
School of Architecture & Civil Engineering, Shenyang University of Technology, Shenyang, China
1 shared publication - Fangai Yu
School of Mechanical Engineering Shenyang University of Technology Shenyang China
1 shared publication H Li
School of Architecture and Civil Engineering, Shenyang University of Technology, Shenyang 110870, People’s Republic of China
1 shared publication
Latest Publications
- 3 September 2024
- Published by Springer Nature
- p. 577-592
Study on the Delamination Damage Prediction of Wind Turbine Blade Spar Cap Based on Morphology Feature Recognition
- 3 September 2024
- Published by Springer Nature
- p. 577-592
Study on the Delamination Damage Prediction of Wind Turbine Blade Spar Cap Based on Morphology Feature Recognition
- Open Access
Study on the Effect of Initial Delamination on Tensile Behavior of Offshore Wind Turbine Blade Spar Cap
Delamination damage to spar caps seriously endangers the operation safety of offshore wind turbines. The effect of initial delamination of various depths and areas on the ultimate tensile load of laminates is studied based on experiments and numerical simulation, and an effective method for predicting the residual tensile strength of laminates with high thickness is proposed. Three groups of initial delamination specimens with different characteristics were fabricated, and static displacement tensile tests were carried out. An accurate three-dimensional numerical analysis model was established, and the results were in good agreement with the experimental values, with the overall error of the failure load being less than 6%. Furthermore, a numerical model for a 20-ply high-thickness spar cap laminate was established to predict the effect of delamination on tensile strength. The results showed that, for the same depth of initial delamination, the difference in delamination area had little influence on the tensile strength. The dangerous locations of delamination were at the shallow surface and at the ratio of 0.3–0.4 in the thickness direction, and the maximum decrease in tensile strength was 14.86%; meanwhile, it was found that delamination on the middle surface had no significant effect on tensile strength.
Open AccessStudy on the Effect of Initial Delamination on Tensile Behavior of Offshore Wind Turbine Blade Spar Cap
Delamination damage to spar caps seriously endangers the operation safety of offshore wind turbines. The effect of initial delamination of various depths and areas on the ultimate tensile load of laminates is studied based on experiments and numerical simulation, and an effective method for predicting the residual tensile strength of laminates with high thickness is proposed. Three groups of initial delamination specimens with different characteristics were fabricated, and static displacement tensile tests were carried out. An accurate three-dimensional numerical analysis model was established, and the results were in good agreement with the experimental values, with the overall error of the failure load being less than 6%. Furthermore, a numerical model for a 20-ply high-thickness spar cap laminate was established to predict the effect of delamination on tensile strength. The results showed that, for the same depth of initial delamination, the difference in delamination area had little influence on the tensile strength. The dangerous locations of delamination were at the shallow surface and at the ratio of 0.3–0.4 in the thickness direction, and the maximum decrease in tensile strength was 14.86%; meanwhile, it was found that delamination on the middle surface had no significant effect on tensile strength.
- Open Access
Repair Parameter Design of Outer Reinforcement Layers of Offshore Wind Turbine Blade Spar Cap Based on Structural and Aerodynamic Analysis
The influence of the outer reinforcement layers on the repair structure and aerodynamic performance was studied. Firstly, a continuous damage mechanics model was established, and the 3D Hashin criterion and cohesive zone material model were used to analyze the damage repair model. The failure load deviation was 5.5%. Secondly, on the basis of the transition model and SST–ω turbulence model, the aerodynamic analysis model of DU300 airfoil was established. The numerical simulation results showed that the lift coefficient and pressure distribution at the angle of attack of 10° and 15° were deviated from the experimental values by 2%. Furthermore, 27 structural repair models, nine 2D aerodynamic repair models, and a 3D full-scale blade model were designed. It was found that, when the repair length accounted for 60% of the total model length, the failure load increased by 22%, but the aerodynamic power with the repair length of 10 m was decreased by 0.137%. When the repair area was large and the repair height was from 4 mm to 6 mm, the failure load was greatly increased by about 30%, and the aerodynamic pressure distribution and static pressure field fluctuated significantly. The results show that the structural and aerodynamic characteristics were closely related to the repair parameters.Open AccessRepair Parameter Design of Outer Reinforcement Layers of Offshore Wind Turbine Blade Spar Cap Based on Structural and Aerodynamic Analysis
The influence of the outer reinforcement layers on the repair structure and aerodynamic performance was studied. Firstly, a continuous damage mechanics model was established, and the 3D Hashin criterion and cohesive zone material model were used to analyze the damage repair model. The failure load deviation was 5.5%. Secondly, on the basis of the transition model and SST–ω turbulence model, the aerodynamic analysis model of DU300 airfoil was established. The numerical simulation results showed that the lift coefficient and pressure distribution at the angle of attack of 10° and 15° were deviated from the experimental values by 2%. Furthermore, 27 structural repair models, nine 2D aerodynamic repair models, and a 3D full-scale blade model were designed. It was found that, when the repair length accounted for 60% of the total model length, the failure load increased by 22%, but the aerodynamic power with the repair length of 10 m was decreased by 0.137%. When the repair area was large and the repair height was from 4 mm to 6 mm, the failure load was greatly increased by about 30%, and the aerodynamic pressure distribution and static pressure field fluctuated significantly. The results show that the structural and aerodynamic characteristics were closely related to the repair parameters. - 8 February 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 33 (5) , 055008
Depth detection of spar cap defects in large-scale wind turbine blades based on a 3D heat conduction model using step heating infrared thermography
The defects dispersed in a spar cap often lead to the failure of large-scale wind turbine blades. To predict the residual service life of the blade and make the repair, it is necessary to detect the depth of spar cap defects. Step-heating thermography (SHT) is a common infrared technique in this domain. However, the existing methods of SHT on defect depth detection are generally based on 1D models, which are unable to accurately detect the depth of spar cap defects due to ignoring material anisotropy and in-plane heat flow. To improve the depth detection accuracy of spar cap defects, a 3D model based on the theory of heat transfer is established by using the equivalent source method (ESM), and a defect depth criterion is proposed based on the analytical solution of the heat conduction equation. The modeling process is as follows. The heat conduction model of SHT was established by ESM. Then, coordinate transformation, variables separation, and Laplace transformation were utilized to solve the 3D heat conduction equation. A defect depth criterion was proposed based on emerging contrast Cr. A glass fiber reinforced plastic composite plate containing 12 square flat-bottom holes with different sizes and depths was manufactured to represent a spar cap with large thermal resistance defects, such as delamination and cracks. The experimental results demonstrate the validity of the 3D model. Then, the model was applied to an on-site SHT test of a 1.5 MW wind turbine blade. The test results prove that the depth detection accuracy of spar cap defects can be significantly improved by using the 3D model. In addition, by using an improved principle component analysis (PCA) method containing a contrast enhancement factor, artifacts can be reduced and the recognition time of defects can be shortened. The 3D model provides a tool for detecting the depth of deep-lying defects in a thick composite structure, and the SHT technology is optimized by improved PCA.
- 8 February 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 33 (5) , 055008
Depth detection of spar cap defects in large-scale wind turbine blades based on a 3D heat conduction model using step heating infrared thermography
The defects dispersed in a spar cap often lead to the failure of large-scale wind turbine blades. To predict the residual service life of the blade and make the repair, it is necessary to detect the depth of spar cap defects. Step-heating thermography (SHT) is a common infrared technique in this domain. However, the existing methods of SHT on defect depth detection are generally based on 1D models, which are unable to accurately detect the depth of spar cap defects due to ignoring material anisotropy and in-plane heat flow. To improve the depth detection accuracy of spar cap defects, a 3D model based on the theory of heat transfer is established by using the equivalent source method (ESM), and a defect depth criterion is proposed based on the analytical solution of the heat conduction equation. The modeling process is as follows. The heat conduction model of SHT was established by ESM. Then, coordinate transformation, variables separation, and Laplace transformation were utilized to solve the 3D heat conduction equation. A defect depth criterion was proposed based on emerging contrast Cr. A glass fiber reinforced plastic composite plate containing 12 square flat-bottom holes with different sizes and depths was manufactured to represent a spar cap with large thermal resistance defects, such as delamination and cracks. The experimental results demonstrate the validity of the 3D model. Then, the model was applied to an on-site SHT test of a 1.5 MW wind turbine blade. The test results prove that the depth detection accuracy of spar cap defects can be significantly improved by using the 3D model. In addition, by using an improved principle component analysis (PCA) method containing a contrast enhancement factor, artifacts can be reduced and the recognition time of defects can be shortened. The 3D model provides a tool for detecting the depth of deep-lying defects in a thick composite structure, and the SHT technology is optimized by improved PCA.
- Open Access
- 9 January 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (2) , 491
A Quantitative Study on the Void Defects Evolving into Damage in Wind Turbine Blade Based on Internal Energy Storage
As manufacturing defects, voids in wind turbine blades may cause damage under fatigue loads. In this paper, the internal energy storage is used as an indicator to identify the critical moment when a defect evolves into damage. The heat transfer equation of composites material containing void defects is derived based upon the theory of the thermodynamics of irreversible processes. In order to obtain the numerical calculation model of the internal energy storage of the evolving process, the thermal conductivity along the transverse direction is homogenized as the temperature date along this direction is acquired by a thermal camera. Specimens with different void fractions are tested with infrared thermal imaging under fatigue load, during which the stress, strain and temperature data are acquired to establish the curve of internal energy storage against the fatigue cycle. This relationship curve can be used to identify the critical moment when void defects evolve into damage. The feasibility of this method is proven by microscopic observation.
- 9 January 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (2) , 491
Open AccessA Quantitative Study on the Void Defects Evolving into Damage in Wind Turbine Blade Based on Internal Energy Storage
As manufacturing defects, voids in wind turbine blades may cause damage under fatigue loads. In this paper, the internal energy storage is used as an indicator to identify the critical moment when a defect evolves into damage. The heat transfer equation of composites material containing void defects is derived based upon the theory of the thermodynamics of irreversible processes. In order to obtain the numerical calculation model of the internal energy storage of the evolving process, the thermal conductivity along the transverse direction is homogenized as the temperature date along this direction is acquired by a thermal camera. Specimens with different void fractions are tested with infrared thermal imaging under fatigue load, during which the stress, strain and temperature data are acquired to establish the curve of internal energy storage against the fatigue cycle. This relationship curve can be used to identify the critical moment when void defects evolve into damage. The feasibility of this method is proven by microscopic observation.