Michael Neubauer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael Neubauer has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Verl
University of Stuttgart
9 shared publications - Armin Lechler
Institute for Control Engineering of Machine Tools and Manufacturing Units (ISW), University of Stuttgart, Stuttgart, Germany
6 shared publications - Christoph Hinze
Institute for Control Engineering of Machine Tools and Manufacturing Units, University of Stuttgart, Stuttgart, Germany
3 shared publications - Colin Reiff
Institute for Control Engineering of Machine Tools and Manufacturing Units (ISW), University of Stuttgart, Seidenstr. 36, 70174 Stuttgart, Germany
3 shared publications - David Dietrich
ISW, ISW, University of Stuttgart, Stuttgart, Germany
3 shared publications - Patrick Mesmer
University of Stuttgart
2 shared publications
Latest Publications
- 7 July 2026
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2026-01 (52) , 2527
Laser-Induced Graphene Electrodes for Electrochemical Conductivity Sensing in Automated Soil-Water Monitoring Systems
Electrochemical conductivity measurements are widely used to assess solute content in soil pore water and shallow aqueous environments, where conductivity can vary over short spatial and temporal scales due to hydrologic events, soil structure, and ion transport processes. Automated soil-water monitoring platforms that integrate microfluidic sampling with electrochemical analysis offer a practical approach for capturing these dynamics. However, sensor performance in such systems is strongly influenced by electrode material properties, particularly under low ionic strength conditions and small sample volumes. In this work, laser-induced graphene (LIG) and planar gold electrodes are evaluated as conductivity sensing elements using electrochemical impedance spectroscopy (EIS) within a microfluidic measurement geometry representative of automated soil-water sampling. LIG electrodes are fabricated by laser pyrolysis of polymer substrates, forming a porous and rough graphene network with a high density of defects and surface functional groups.
- 7 July 2026
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2026-01 (52) , 2527
Laser-Induced Graphene Electrodes for Electrochemical Conductivity Sensing in Automated Soil-Water Monitoring Systems
Electrochemical conductivity measurements are widely used to assess solute content in soil pore water and shallow aqueous environments, where conductivity can vary over short spatial and temporal scales due to hydrologic events, soil structure, and ion transport processes. Automated soil-water monitoring platforms that integrate microfluidic sampling with electrochemical analysis offer a practical approach for capturing these dynamics. However, sensor performance in such systems is strongly influenced by electrode material properties, particularly under low ionic strength conditions and small sample volumes. In this work, laser-induced graphene (LIG) and planar gold electrodes are evaluated as conductivity sensing elements using electrochemical impedance spectroscopy (EIS) within a microfluidic measurement geometry representative of automated soil-water sampling. LIG electrodes are fabricated by laser pyrolysis of polymer substrates, forming a porous and rough graphene network with a high density of defects and surface functional groups.
- Open Access
- 18 April 2026
- Published by Elsevier in Journal of Engineering Research
- Vol. 14 (3) , 3355-3363
Use cases for Manufacturing-X: Benefits of data spaces in industrial practice
- 18 April 2026
- Published by Elsevier in Journal of Engineering Research
- Vol. 14 (3) , 3355-3363
Open AccessUse cases for Manufacturing-X: Benefits of data spaces in industrial practice
- 24 November 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-02 (63) , 2961
Microfabricated Electrochemical Sensors as a Sentinel System to Detect Biofilms in River Systems
Monitoring river water quality is crucial for assessing and maintaining the health of local ecosystems, particularly in agriculture and livestock management. This is especially true in arid regions like Montana, where limited water sources necessitate sustainable water management practices to support farming and ranching. In these areas, rivers and streams often serve as key water supplies for irrigation, livestock, and even drinking water, making it essential to monitor and manage water quality effectively. The U.S. Geological Survey (USGS) autonomously measures water temperature, conductivity, and flow rates, among others, to assess river conditions, but there is currently no assessment of microbial concentration. Manual field sampling and laboratory analysis are the standard protocols to analyze dynamic changes, with results often impeded by high costs for labor and required wet-chemical laboratory settings. Also, localized sampling minimizes the spatial resolution of environmental changes. There is a need for an autonomous, low-cost water monitoring system that can be integrated into a sentinel remote sensing unit for biofilm and pathogen detection in harsh environments. This study reports the two-month deployment of microfabricated sensor arrays to measure temperature, conductivity, and electrochemical impedance spectroscopy (EIS) in the Clark Fork River at USGS site 12323800 near Galen, Montana. Two sensor arrays connected to an additively manufactured waterproof housing were submerged in the river, and data was collected with a Data Acquistion Station (DAQ) described below. Data from each sensor was collected every 15 minutes for the whole duration of the installment and stored locally. A Data Acquisition Station (DAQ) was developed using a single-board computer to control an on-site impedance spectroscope and log sensor data. The DAQ supports data retrieval via Wi-Fi and LoRa interfaces. The Wi-Fi interface is designed for transferring large datasets over short distances, with an effective range of approximately 300 feet (about 91 meters) from the base station. In contrast, the LoRa interface transmits status updates and control data, typically a few bytes in size, over distances up to 20 miles (approximately 32 kilometers) in rural areas. The DAQ features an HTTPS-secured RESTful API, enabling seamless integration into an overarching network infrastructure and providing point-to-point access. Future deployments plan to use the LoRa interface. The sensor arrays were made of thin film Au structures on borosilicate glass, which were fabricated using standard evaporation, lithography, and wet chemical etching techniques. The resistive temperature device (RTD) and ring electrode conductivity sensors were added to the sensor array in part to compare to data from the USGS probe located at the same site. The EIS sensor consisted of 50 pairs of 10 µm interdigitated electrodes (IDE) with 15 µm gaps. To enhance sensitivity and stability, one side of the EIS IDE was modified with poly (4-styrenesulfonic acid) doped with pyrrole, termed PPy:PSS. Impedance sweeps of 100 mV from 100 Hz to 100 kHz were recorded for the Eis sensor. The temperature and conductivity data from these sensors were compared to those generated by USGS, and the general daily trends were in good agreement. The discrepancy in the magnitude of the measured values indicates that further work should be done to characterize the performance of these sensors. EIS data from each sweep was fit to a Randles circuit with a constant phase element (CPE) to describe interface processes. The CPE magnitude was tracked over deployment and gradually increased, indicating biofilm growth on the sensor. After 600 hours, the value saturated, suggesting a complete biofilm layer had formed. Our results provide new insights into water biology fluctuations and demonstrate the potential of EIS for real-time monitoring applications.
- 24 November 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-02 (63) , 2961
Microfabricated Electrochemical Sensors as a Sentinel System to Detect Biofilms in River Systems
Monitoring river water quality is crucial for assessing and maintaining the health of local ecosystems, particularly in agriculture and livestock management. This is especially true in arid regions like Montana, where limited water sources necessitate sustainable water management practices to support farming and ranching. In these areas, rivers and streams often serve as key water supplies for irrigation, livestock, and even drinking water, making it essential to monitor and manage water quality effectively. The U.S. Geological Survey (USGS) autonomously measures water temperature, conductivity, and flow rates, among others, to assess river conditions, but there is currently no assessment of microbial concentration. Manual field sampling and laboratory analysis are the standard protocols to analyze dynamic changes, with results often impeded by high costs for labor and required wet-chemical laboratory settings. Also, localized sampling minimizes the spatial resolution of environmental changes. There is a need for an autonomous, low-cost water monitoring system that can be integrated into a sentinel remote sensing unit for biofilm and pathogen detection in harsh environments. This study reports the two-month deployment of microfabricated sensor arrays to measure temperature, conductivity, and electrochemical impedance spectroscopy (EIS) in the Clark Fork River at USGS site 12323800 near Galen, Montana. Two sensor arrays connected to an additively manufactured waterproof housing were submerged in the river, and data was collected with a Data Acquistion Station (DAQ) described below. Data from each sensor was collected every 15 minutes for the whole duration of the installment and stored locally. A Data Acquisition Station (DAQ) was developed using a single-board computer to control an on-site impedance spectroscope and log sensor data. The DAQ supports data retrieval via Wi-Fi and LoRa interfaces. The Wi-Fi interface is designed for transferring large datasets over short distances, with an effective range of approximately 300 feet (about 91 meters) from the base station. In contrast, the LoRa interface transmits status updates and control data, typically a few bytes in size, over distances up to 20 miles (approximately 32 kilometers) in rural areas. The DAQ features an HTTPS-secured RESTful API, enabling seamless integration into an overarching network infrastructure and providing point-to-point access. Future deployments plan to use the LoRa interface. The sensor arrays were made of thin film Au structures on borosilicate glass, which were fabricated using standard evaporation, lithography, and wet chemical etching techniques. The resistive temperature device (RTD) and ring electrode conductivity sensors were added to the sensor array in part to compare to data from the USGS probe located at the same site. The EIS sensor consisted of 50 pairs of 10 µm interdigitated electrodes (IDE) with 15 µm gaps. To enhance sensitivity and stability, one side of the EIS IDE was modified with poly (4-styrenesulfonic acid) doped with pyrrole, termed PPy:PSS. Impedance sweeps of 100 mV from 100 Hz to 100 kHz were recorded for the Eis sensor. The temperature and conductivity data from these sensors were compared to those generated by USGS, and the general daily trends were in good agreement. The discrepancy in the magnitude of the measured values indicates that further work should be done to characterize the performance of these sensors. EIS data from each sweep was fit to a Randles circuit with a constant phase element (CPE) to describe interface processes. The CPE magnitude was tracked over deployment and gradually increased, indicating biofilm growth on the sensor. After 600 hours, the value saturated, suggesting a complete biofilm layer had formed. Our results provide new insights into water biology fluctuations and demonstrate the potential of EIS for real-time monitoring applications.
- 10 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 22 (15455955) , 16168-16184
A Nonlinear Elasticity Model and Feedforward Compensation Method to Increase Positioning Accuracy of Industrial Robots
Large industrial robots are inexpensive compared to their workspace. Due to flexibility, the positioning accuracy is compromised. This paper presents a simple yet effective static calibration method for robots using a laser tracker that can be applied to processes with no change in external load and without high processing forces. The calibration method is based on a novel elastokinematic model that captures the nonlinear gearbox and link compliance and also accounts for the effects of pose dependent joint friction and nonlinearities due to the gravity compensation mechanism. Furthermore, a feedforward concept is presented that separates kinematics from compliance to reduce computation time. The calibration method was implemented on industrial hardware and experimentally validated on a KUKA KR210–2. In comparison to state of the art compliance modeling, accuracy is improved by 23.1 %. Finally, the feedforward model reduces the mean positioning error in the entire workspace by 54.9% compared to the purely kinematically calibrated model, emphasizing the need for compliance compensation.
- 10 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 22 (15455955) , 16168-16184
A Nonlinear Elasticity Model and Feedforward Compensation Method to Increase Positioning Accuracy of Industrial Robots
Large industrial robots are inexpensive compared to their workspace. Due to flexibility, the positioning accuracy is compromised. This paper presents a simple yet effective static calibration method for robots using a laser tracker that can be applied to processes with no change in external load and without high processing forces. The calibration method is based on a novel elastokinematic model that captures the nonlinear gearbox and link compliance and also accounts for the effects of pose dependent joint friction and nonlinearities due to the gravity compensation mechanism. Furthermore, a feedforward concept is presented that separates kinematics from compliance to reduce computation time. The calibration method was implemented on industrial hardware and experimentally validated on a KUKA KR210–2. In comparison to state of the art compliance modeling, accuracy is improved by 23.1 %. Finally, the feedforward model reduces the mean positioning error in the entire workspace by 54.9% compared to the purely kinematically calibrated model, emphasizing the need for compliance compensation.
- Open Access
- 14 March 2025
- Published by Elsevier in Robotics and Computer-Integrated Manufacturing
- Vol. 95
Semi-active damping for industrial robots
- 14 March 2025
- Published by Elsevier in Robotics and Computer-Integrated Manufacturing
- Vol. 95
Open AccessSemi-active damping for industrial robots
- 18 November 2023
- Published by Springer Nature
- p. 514-524
Software-Defined Value Networks: Motivation, Approaches, and Research Activities
- 18 November 2023
- Published by Springer Nature
- p. 514-524
Software-Defined Value Networks: Motivation, Approaches, and Research Activities
- 24 August 2023
- Published by Springer Nature
- p. 611-621
Iterative Planning as a Holistic Framework for Production System-Wide Optimization Control Loops
- 24 August 2023
- Published by Springer Nature
- p. 611-621
Iterative Planning as a Holistic Framework for Production System-Wide Optimization Control Loops
- Open Access
- 1 May 2023
- Published by Walter de Gruyter GmbH in at - Automatisierungstechnik
- Vol. 71 (5) , 351-363
Cloud-based evaluation platform for software-defined manufacturing
Software-Defined Manufacturing (SDM) is a new paradigm for how to manufacture in the Industry 4.0 factory of the future. The approach requires a fundamental change in thinking and reinvention of central business models in production technology. This paper discusses the main challenges on the way to a software-defined factory of the future and illustrates possible solutions. An exemplary future factory is presented, in which the validation of the solutions is carried out. For this purpose, cloud-based Computerized Numerical Control (CNC) is considered as use case. Experimental results demonstrate the proof of concept and show the potential for further applications.
- 1 May 2023
- Published by Walter de Gruyter GmbH in at - Automatisierungstechnik
- Vol. 71 (5) , 351-363
Open AccessCloud-based evaluation platform for software-defined manufacturing
Software-Defined Manufacturing (SDM) is a new paradigm for how to manufacture in the Industry 4.0 factory of the future. The approach requires a fundamental change in thinking and reinvention of central business models in production technology. This paper discusses the main challenges on the way to a software-defined factory of the future and illustrates possible solutions. An exemplary future factory is presented, in which the validation of the solutions is carried out. For this purpose, cloud-based Computerized Numerical Control (CNC) is considered as use case. Experimental results demonstrate the proof of concept and show the potential for further applications.
- 1 February 2022
- Published by Elsevier in Robotics and Computer-Integrated Manufacturing
- Vol. 73
Robust design of independent joint control of industrial robots with secondary encoders
- 1 February 2022
- Published by Elsevier in Robotics and Computer-Integrated Manufacturing
- Vol. 73
Robust design of independent joint control of industrial robots with secondary encoders
- Open Access
- 1 October 2021
- Published by Elsevier in International Journal of Machine Tools and Manufacture
- Vol. 169
Cascaded sliding mode position control (SMC-PI) for an improved dynamic behavior of elastic feed drives
- 1 October 2021
- Published by Elsevier in International Journal of Machine Tools and Manufacture
- Vol. 169
Open AccessCascaded sliding mode position control (SMC-PI) for an improved dynamic behavior of elastic feed drives