DKDehao Kong

Dehao Kong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dehao Kong has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Trajectory-Optimized Predictive Control for Power Converters

    by Yuanxiang Sun, Zhenbin Zhang, Dehao Kong, Yongdu Wang, Zhen Li, Marcelo Lobo Heldwein

  • Short-Circuit Fault Ride-Through Method for Dual-Active-Bridge Converters Considering DC-Voltage Inertia Support

    by Heyang Sun, Chuang Liu, Dehao Kong

    The DC distribution network has the characteristics of “low inertia” and “low damping,” among which pole to pole short circuit fault is the most serious type of fault in the DC distribution system. When a short-circuit fault occurs, the port voltage of the dual active bridge (DAB) converter drops sharply. However, there is a risk that the DC circuit breaker (DCCB) may not be able to operate in a timely manner, which can lead to overcurrent locking inside the DAB converter and trigger emergency power outages in the distribution substation area. Therefore, this paper proposes a fault ride-through (FRT) method with voltage inertia support capability. By incorporating a DC voltage inertia support (DC-VIS) circuit at the output port of the DAB converter, the rate of port voltage decline during short-circuit fault conditions is effectively slowed through designing support capacitance. This provides additional time for system identification and DCCB operation while eliminating the risk of overcurrent inside the DAB converter. Under normal conditions with the support capacitor fully charged, the proposed structure does not affect the dynamic response capability of the DAB converter. Furthermore, based on the DC-VIS circuit, an adaptive dynamic limiting strategy is designed to maximize the transmission power of the DAB converter while ensuring coordinated control among multiple modules. The effectiveness of the proposed method is validated through simulations and experiments.

  • Deadbeat Control of Dual Active Bridge Converters With Adaptive Noise Resistance Ability

    by Dehao Kong, Tianxu Cao, Ralph Kennel, Marcelo Lobo Heldwein

    Although deadbeat control offers excellent dynamic performance for dual active bridge (DAB) converters with relatively simple computations, it is sensitive to sampling noise, which degrades system performance and even leads to instability. Existing approaches based on digital filters induce higher computational burden and alter the system pole locations affecting the inherent characteristics of deadbeat-controlled DABs. Therefore, this letter proposes a novel deadbeat control method with adaptive noise resistance ability for DABs. Instead of digital filters, an adaptive attenuation coefficient is used to efficiently and adaptively mitigate the impact of noises, using a simple structure. Combing with the compensation term derived from the system model, it introduces no steady-state error and preserves the original closed-loop pole locations, thereby maximally retaining the essential features of deadbeat control. Experimental results verify the effectiveness and superiority of the proposed method.


  • Fault-Tolerant Model Predictive Control for Three-Level T-Type Converters Based on Fault-Induced State Equation Modeling

    by Tianxu Cao, Dehao Kong, Chaohui Zhang, Bo Long, Marcelo Lobo Heldwein

    Three-level T-type converters (3LT${}^{\mathbf{2}}$Cs) provide inherent redundancies that can be used to improve system-level reliability, where fault-tolerant control (FTC) techniques are the enabling algorithms. Existing FTC methods primarily focus on compensating redundant vectors and adjusting dwell times, while neglecting the impact on modeling and control of grid-side currents and neutral-point (NP) voltage under fault conditions. This work formulates a unified fault-induced state space model that facilitates the construction of cost functions in finite-control-set model predictive control (FCS-MPC). The modeling is based on the investigation of the possible cases of single-switch and double-switch open-circuit faults, and the analysis of additional terms introduced by the faults. The proposed FTC method adopts a dual-loop control structure, i.e., the outer loop uses a proportional integral (PI) controller to automatically increase the reference value of the dc bus voltage during vertical faults and converts it into the grid current reference, while the inner loop combines fault-induced grid-side current and NP voltage cost functions in FCS-MPC, adjusting weighting factors based on fault conditions to prioritize grid-side current quality. Experimental results demonstrate the proposed FTC under various open-circuit fault scenarios.


  • Series Bipolar Hybrid Voltage Optimizer Based on Switching-Cell-Inserted Direct AC–AC Converter and Multiwindings Transformer

    by Dongbo Guo, Dehao Kong, Zhongchen Pei, Xiaonan Gao, Chuang Liu, Pinjia Zhang, Cristian Garcia, Jose Rodriguez

    This article proposes a series bipolar hybrid voltage optimizer (B-HVO), which can work at the noninverting and inverting modes for addressing voltage sag/swell in the utility grid. The superiority of the proposed system is that the direct ac–ac converter cell is deeply integrated with the multiwindings line frequency transformer, which not only effectively diminishes the switches quantities, but also avoids the use of additional isolated transformers when it is applied to distribution network. The proposed B-HVO inherits the strengths of converters fast response and line frequency transformers long-life. The B-HVO has much system reliability because the direct ac–ac converter cell has no shoot-through and commutation problems. In addition, the converter uses four switches and only two switches are switched at high frequency during each half-cycle of input voltage, which evidently reduces the total switching losses. Detailed analysis is provided with experimental results to validate the effectiveness of the proposed system. Besides, the measured data of the proposed system in the engineering demonstration application also proves its validity in handling voltage fluctuation problems.


  • A Dynamic Response Enhanced Model Predictive Control for Bidirectional Dual Active Bridge Converter

    by Heyang Sun, Dehao Kong, Chao Liu, Chuang Liu, Zhongchen Pei, Di Zhu, Jingyue Wang

    Model Predictive Control (MPC) can enhance the dynamic response performance of Dual Active Bridge (DAB) converters, but its strong dependency on model parameters leads to poor system robustness. To address this issue, this paper proposes an ultra-local model based MPC (ULM-MPC) strategy This method establishes a ULM that retains only accurately measurable parameters, categorizes all remaining uncertain parameters as a lumped disturbance, and calculates the lumped disturbance in real-time using parameter identification techniques. Without altering the original control structure, this method eliminates control accuracy degradation caused by model parameter inaccuracies, thereby improving system robustness. Furthermore, building upon dual-phase-shift modulation, the Lagrange multiplier method (LMM) is employed to solve optimal modulation parameters, achieving current stress optimization and enhancing steady-state operational efficiency. Finally, experimental verification is conducted to validate the effectiveness and superiority of the proposed method.


  • Exploring the Inherent Fault-Tolerance of Model-Free Predictive Control in Three-Level T-Type Converters

    by Tianxu Cao, Dehao Kong, Chengkun Hu, Bo Long, Marcelo Lobo Heldwein

    Fault-tolerant control (FTC) improves the reliability of three-level T-type converters under open-circuit faults in power devices. However, existing FTC methods rely on comprehensive and precise fault diagnosis, which significantly increases the complexity of diagnostic algorithms and limits their adaptability. To address this issue, this work proposes a highly adaptive FTC method based on model-free predictive control using an ultra-local model. The proposed approach dynamically estimates model disturbances caused by faults by employing a neural network observer. This eliminates the need for additional control variations due to different fault scenarios and, thus, enables a unified control strategy. Furthermore, this method only requires the prior identification of vertical device faults without the need to diagnose horizontal devices or pinpoint specific faulty components, thereby reducing the complexity of fault diagnosis. Comparative experiments validate the proposed method's adaptive fault-tolerant performance and robustness against filter parameter variations under various fault conditions.


  • Model-Free Predictive Control of Dual-Active-Bridge Converter Based on Sliding-Mode Observer Considering Parameters’ Uncertainty

    by Heyang Sun, Dehao Kong, Chuang Liu, Di Zhu, Jingyue Wang, Yu Jiang, Zhongchen Pei

    The strong parameter dependency of model predictive control (MPC), despite its capability to enhance dynamic performance in dual-active-bridge (DAB) converters, remains a critical limitation. To overcome the parameters’ uncertainty of DAB, this paper proposes a model-free predictive control (MFPC) method integrated with a sliding mode observer (SMO). First, to enhance the steady-state efficiency of the DAB converter, optimization strategies for natural zero-voltage switching (ZVS) and full ZVS are proposed under the constraint of minimum current stress. A comprehensive analysis of the advantages and disadvantages of both methods is conducted, and the most efficiency-optimal approach is selected based on experimental results. Second, an ultra-local model of the DAB converter is established, which innovatively consolidates all uncertainties into a unified lumped disturbance. A full-order SMO is employed to estimate the lumped disturbance in real time, replacing traditional parameter identification techniques. This reduces computational burden while enhancing system robustness. Finally, experimental comparisons with other schemes validate the effectiveness and superiority of the proposed method.


  • Integrated Model Predictive Control of Double-Stage Solid-State Transformers With Dynamic Reference

    by Dehao Kong, Yuanxiang Sun, Zhenbin Zhang, Hui Li, Ralph Kennel, Marcelo Lobo Heldwein

    The dc-link voltage control is crucial for double-stage solid-state transformers. Due to differences in bandwidth and response speed between the two stages, overvoltage and undervoltage may occur in transient states, potentially leading to overmodulation in the rectifier stage and overcurrent in the dc stage. In extreme cases, the reliable operation of the entire system is threatened. Model predictive control (MPC) methods have been utilized to improve the dynamic performance of the dc-link in some previous works. However, they mainly work as the inner loop. While the inner loop is indeed enhanced, the overall dynamic remains limited by the employment of linear controllers in the outer voltage loop. To address this issue, this article proposes an integrated MPC with dynamic reference generation. Herein, the integrated cost functions for both stages account for all relevant variables. Following with it, the dynamic reference method generates real-time commands for the dc-link based on load estimation, eliminating the need for linear controllers in the outer loop. The response speed of the MPC is fully released, significantly improving the dynamic performance of the dc-link while maintaining a straightforward implementation. Finally, the experimental comparisons with other schemes verify the effectiveness and superiority of the proposed method.


  • Consensus-Based Distributed Control of Offshore Wind Farms Connected via DR-HVDC

    by Yuanxiang Sun, Dehao Kong, Zhenbin Zhang, Yongdu Wang, Zhongchen Pei, Di Zhu, Marcelo Lobo Heldwein

    In offshore wind farms connected via diode-rectifier-based high-voltage dc systems, conventional distributed control strategies of wind turbine (WT) converters suffer from significant coupling between active and reactive power and frequency, leading to large oscillations in WT power and offshore frequency during transients. Upon theoretically analyzing this issue using a small-signal model, this work proposes a novel distributed control strategy to address it. Initially, we propose a specially designed consensus-based global average reactive power observer for each local WT controller, where the consensus algorithm is modified from its basic form to support an adjustable reactive power-sharing ratio. By comparing the observed and actual values of reactive power, a dynamically adjustable virtual impedance control is achieved, completely decoupling active and reactive power control. In addition, global reactive power values are also used in frequency droop control as local references, decoupling reactive power and frequency control while achieving proportional reactive power-sharing. Experimental results confirm that the proposed solution eliminates transient oscillations of reactive power and frequency compared to existing conventional and decoupled control methods.