Hyeongmin Jin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hyeongmin Jin has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Chang Heon Choi
Department of Radiation Oncology Seoul National University Hospital Seoul Republic of Korea
14 shared publications - Jung-In Kim
Department of Radiation Oncology Seoul National University Hospital Seoul Republic of Korea
14 shared publications - Jong Min Park
Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
12 shared publications - Seonghee Kang
Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
11 shared publications - Jaeman Son
Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
9 shared publications - Inbum Lee
Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
7 shared publications
Latest Publications
- Open Access
- 30 September 2026
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 37 (3) , 89-107
Risk-Based Management of Patients with Cardiac Implantable Electronic Devices Underwent Radiation Therapy: A Practical Review
Na Hye Kwon, Inbum Lee, Euntaek Yoon, Bo-Wi Cheon, Young Jae Jang, Chang Heon Choi, Hyeongmin Jin, Jaeman Son, Jongmin Park, Jung-in Kim, Seonghee Kang, Sung Hyun Lee, Yoonsuk Huh. Progress in Medical Physics 2026;37:89-107. https://doi.org/10.14316/pmp.2026.37.3.89
- 30 September 2026
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 37 (3) , 89-107
Open AccessRisk-Based Management of Patients with Cardiac Implantable Electronic Devices Underwent Radiation Therapy: A Practical Review
Na Hye Kwon, Inbum Lee, Euntaek Yoon, Bo-Wi Cheon, Young Jae Jang, Chang Heon Choi, Hyeongmin Jin, Jaeman Son, Jongmin Park, Jung-in Kim, Seonghee Kang, Sung Hyun Lee, Yoonsuk Huh. Progress in Medical Physics 2026;37:89-107. https://doi.org/10.14316/pmp.2026.37.3.89
- Open Access
- 11 August 2026
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- p. 1-18
Planning CT-Guided Dual-Branch Attention GAN for Longitudinal CBCT Outpainting in Adaptive Radiotherapy
Limited longitudinal field of view in cone-beam computed tomography (CBCT) remains a significant challenge for image-guided adaptive radiotherapy. We developed a deep learning–based CBCT outpainting framework that synthesizes anatomically consistent extensions beyond the scanned volume. The model employs a dual-branch encoder–decoder architecture that separately encodes CBCT and edge maps derived from planning CT (pCT) and integrates them via attention-guided skip connections and late fusion to preserve structure while accommodating cross-modality differences. The framework was trained and validated using 90 prostate cancer cases, with 20 held-out patients used for quantitative evaluation against four baseline models. The proposed method achieved the lowest absolute volume difference for the clinical target volume at 0.11 ± 0.07 cc and for the planning target volume at 0.05 ± 0.04 cc. It also yielded superior perceptual image quality, with LPIPS of 0.119 ± 0.029 and FID of 54.70. Qualitative assessment confirmed improved soft-tissue continuity and more faithful preservation of anatomical landmarks in both bony and low-contrast regions. These results demonstrate that the proposed framework can restore CBCT longitudinal coverage with high anatomical fidelity, supporting more reliable deformable registration and adaptive radiotherapy workflows in clinical environments constrained by limited-FOV CBCT.
- 11 August 2026
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- p. 1-18
Open AccessPlanning CT-Guided Dual-Branch Attention GAN for Longitudinal CBCT Outpainting in Adaptive Radiotherapy
Limited longitudinal field of view in cone-beam computed tomography (CBCT) remains a significant challenge for image-guided adaptive radiotherapy. We developed a deep learning–based CBCT outpainting framework that synthesizes anatomically consistent extensions beyond the scanned volume. The model employs a dual-branch encoder–decoder architecture that separately encodes CBCT and edge maps derived from planning CT (pCT) and integrates them via attention-guided skip connections and late fusion to preserve structure while accommodating cross-modality differences. The framework was trained and validated using 90 prostate cancer cases, with 20 held-out patients used for quantitative evaluation against four baseline models. The proposed method achieved the lowest absolute volume difference for the clinical target volume at 0.11 ± 0.07 cc and for the planning target volume at 0.05 ± 0.04 cc. It also yielded superior perceptual image quality, with LPIPS of 0.119 ± 0.029 and FID of 54.70. Qualitative assessment confirmed improved soft-tissue continuity and more faithful preservation of anatomical landmarks in both bony and low-contrast regions. These results demonstrate that the proposed framework can restore CBCT longitudinal coverage with high anatomical fidelity, supporting more reliable deformable registration and adaptive radiotherapy workflows in clinical environments constrained by limited-FOV CBCT.
- Open Access
- 11 April 2026
- Published by Springer Nature in Radiation Oncology
- Vol. 21 (1)
Machine learning approach to estimation of in vivo measured dose and treatment planning for total body irradiation
This study aims to enhance the conventional Total Body Irradiation (TBI) dose calculation method which relies on manual calculation using tissue maximum ra
- 11 April 2026
- Published by Springer Nature in Radiation Oncology
- Vol. 21 (1)
Open AccessMachine learning approach to estimation of in vivo measured dose and treatment planning for total body irradiation
This study aims to enhance the conventional Total Body Irradiation (TBI) dose calculation method which relies on manual calculation using tissue maximum ra
- Open Access
- 31 March 2026
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 37 (1) , 28-37
Prediction of Therapeutic and Imaging Doses in the Gonadal Shielding Block Using Monte Carlo Simulation
Sung Hyun Lee, Inbum Lee, Bo-Wi Cheon, Jin Jegal, Hyeongmin Jin, Jong Min Park, Chang Heon Choi, Jung-in Kim, Kyung Su Kim, Eui Kyu Chie, Seonghee Kang. Progress in Medical Physics 2026;37:28-37. https://doi.org/10.14316/pmp.2026.37.1.28
- 31 March 2026
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 37 (1) , 28-37
Open AccessPrediction of Therapeutic and Imaging Doses in the Gonadal Shielding Block Using Monte Carlo Simulation
Sung Hyun Lee, Inbum Lee, Bo-Wi Cheon, Jin Jegal, Hyeongmin Jin, Jong Min Park, Chang Heon Choi, Jung-in Kim, Kyung Su Kim, Eui Kyu Chie, Seonghee Kang. Progress in Medical Physics 2026;37:28-37. https://doi.org/10.14316/pmp.2026.37.1.28
- Open Access
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 165-174
Performance Evaluation of the HyperSight Cone-Beam Computed Tomography System on the Halcyon Platform: Installation Acceptance and Quantitative Image Quality Assessment
Yoonsuk Huh, Euntaek Yoon, Jin Jegal, Inbum Lee, Bo-Wi Cheon, Jongmin Park, Jung-in Kim, Chang Heon Choi, Seonghee Kang, Sung Hyun Lee, Hyeongmin Jin, Jaeman Son. Progress in Medical Physics 2025;36:165-74. https://doi.org/10.14316/pmp.2025.36.4.165
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 165-174
Open AccessPerformance Evaluation of the HyperSight Cone-Beam Computed Tomography System on the Halcyon Platform: Installation Acceptance and Quantitative Image Quality Assessment
Yoonsuk Huh, Euntaek Yoon, Jin Jegal, Inbum Lee, Bo-Wi Cheon, Jongmin Park, Jung-in Kim, Chang Heon Choi, Seonghee Kang, Sung Hyun Lee, Hyeongmin Jin, Jaeman Son. Progress in Medical Physics 2025;36:165-74. https://doi.org/10.14316/pmp.2025.36.4.165
- Open Access
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 139-146
Clinical Validation of EPIbeam as a Patient-Specific Pre-Treatment Quality Assurance System
Euntaek Yoon, Inbum Lee, Yoonsuk Huh, Bo-Wi Cheon, Jin Jegal, Hyeongmin Jin, Sung Hyun Lee, Seonghee Kang, Chang Heon Choi, Jong Min Park, Jung-in Kim, Jaeman Son. Progress in Medical Physics 2025;36:139-46. https://doi.org/10.14316/pmp.2025.36.4.139
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 139-146
Open AccessClinical Validation of EPIbeam as a Patient-Specific Pre-Treatment Quality Assurance System
Euntaek Yoon, Inbum Lee, Yoonsuk Huh, Bo-Wi Cheon, Jin Jegal, Hyeongmin Jin, Sung Hyun Lee, Seonghee Kang, Chang Heon Choi, Jong Min Park, Jung-in Kim, Jaeman Son. Progress in Medical Physics 2025;36:139-46. https://doi.org/10.14316/pmp.2025.36.4.139
- Open Access
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 147-154
Head Leakage in Modern Clinical Linear Accelerators: A Multimachine Appraisal at Seoul National University Hospital
Inbum Lee, Euntaek Yoon, Bo-Wi Cheon, Jin Jegal, Yoonsuk Huh, Jong Min Park, Jung-in Kim, Chang Heon Choi, Seonghee Kang, Jaeman Son, Hyeongmin Jin, Sung Hyun Lee. Progress in Medical Physics 2025;36:147-54. https://doi.org/10.14316/pmp.2025.36.4.147
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 147-154
Open AccessHead Leakage in Modern Clinical Linear Accelerators: A Multimachine Appraisal at Seoul National University Hospital
Inbum Lee, Euntaek Yoon, Bo-Wi Cheon, Jin Jegal, Yoonsuk Huh, Jong Min Park, Jung-in Kim, Chang Heon Choi, Seonghee Kang, Jaeman Son, Hyeongmin Jin, Sung Hyun Lee. Progress in Medical Physics 2025;36:147-54. https://doi.org/10.14316/pmp.2025.36.4.147
- 16 December 2025
- Published by Elsevier in Physica Medica
- Vol. 141, 105707
Comparative study of inertial measurement unit and optical tracking systems for respiratory motion management in radiotherapy
- 16 December 2025
- Published by Elsevier in Physica Medica
- Vol. 141, 105707
Comparative study of inertial measurement unit and optical tracking systems for respiratory motion management in radiotherapy
- Open Access
- 30 September 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (3) , 61-69
Clinical Commissioning of a Ceiling-Mounted Spoiler for Total Body Irradiation
Jin Jegal, Yoonsuk Huh, Inbum Lee, Bo-Wi Cheon, Euntaek Yoon, Seonghee Kang, Jaeman Son, Sung Hyun Lee, Chang Heon Choi, Jung-in Kim, Hyeongmin Jin. Progress in Medical Physics 2025;36:61-39. https://doi.org/10.14316/pmp.2025.36.3.61
- 30 September 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (3) , 61-69
Open AccessClinical Commissioning of a Ceiling-Mounted Spoiler for Total Body Irradiation
Jin Jegal, Yoonsuk Huh, Inbum Lee, Bo-Wi Cheon, Euntaek Yoon, Seonghee Kang, Jaeman Son, Sung Hyun Lee, Chang Heon Choi, Jung-in Kim, Hyeongmin Jin. Progress in Medical Physics 2025;36:61-39. https://doi.org/10.14316/pmp.2025.36.3.61
- Open Access
- 21 August 2025
- Published by Springer Nature in Strahlentherapie und Onkologie
- Vol. 202 (1) , 84-94
Carbon ion radiotherapy optimization techniques for pancreatic cancer: accounting for the effect of bowel gas variation
Background: Dose variation due to changes in bowel air poses significant challenges for carbon radiotherapy in pancreatic cancer. This retrospective study evaluated a density-override optimization technique to mitigate dosimetric uncertainties caused by bowel air changes. Materials and methods: Planning CT and cone-beam CT data from 8 patients with locally advanced pancreatic cancer undergoing stereotactic ablative radiotherapy were analyzed. Treatment simulations used a dose of 55.2 GyE in 12 fractions with a four-field setup (anterior, lateral, posterior, posterior oblique). Four density-override patterns were compared: pattern 0 (no override), pattern 1 (replacing bowel gas with water), pattern 2 (replacing the entire bowel with mean bowel HU), and pattern 3 (replacing bowel gas with mean bowel HU). Dose evaluations included fraction-wise and accumulated dose analyses, focusing on target coverage, homogeneity index, and organs at risk doses. Results: Pattern 2 achieved the largest clinical tumor volume coverage and the fewest fractions with > 5% coverage loss for the anterior beam, followed by pattern 3. However, pattern 2 demonstrated poorer homogeneity for the lateral beam compared to patterns 1 and 3 and a higher gastrointestinal (GI) dose for the anterior beam. Conclusion: This study evaluated the importance of density overrides to address bowel air variations. For patients where a more uniform dose is desirable or whose tumor is adjacent to the GI tract, a pattern 3 density-override should be considered.
- 21 August 2025
- Published by Springer Nature in Strahlentherapie und Onkologie
- Vol. 202 (1) , 84-94
Open AccessCarbon ion radiotherapy optimization techniques for pancreatic cancer: accounting for the effect of bowel gas variation
Background: Dose variation due to changes in bowel air poses significant challenges for carbon radiotherapy in pancreatic cancer. This retrospective study evaluated a density-override optimization technique to mitigate dosimetric uncertainties caused by bowel air changes. Materials and methods: Planning CT and cone-beam CT data from 8 patients with locally advanced pancreatic cancer undergoing stereotactic ablative radiotherapy were analyzed. Treatment simulations used a dose of 55.2 GyE in 12 fractions with a four-field setup (anterior, lateral, posterior, posterior oblique). Four density-override patterns were compared: pattern 0 (no override), pattern 1 (replacing bowel gas with water), pattern 2 (replacing the entire bowel with mean bowel HU), and pattern 3 (replacing bowel gas with mean bowel HU). Dose evaluations included fraction-wise and accumulated dose analyses, focusing on target coverage, homogeneity index, and organs at risk doses. Results: Pattern 2 achieved the largest clinical tumor volume coverage and the fewest fractions with > 5% coverage loss for the anterior beam, followed by pattern 3. However, pattern 2 demonstrated poorer homogeneity for the lateral beam compared to patterns 1 and 3 and a higher gastrointestinal (GI) dose for the anterior beam. Conclusion: This study evaluated the importance of density overrides to address bowel air variations. For patients where a more uniform dose is desirable or whose tumor is adjacent to the GI tract, a pattern 3 density-override should be considered.