Inbum Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Inbum Lee has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Jung-In Kim
Department of Radiation Oncology Seoul National University Hospital Seoul Republic of Korea
14 shared publications - Chang Heon Choi
Department of Radiation Oncology Seoul National University Hospital Seoul Republic of Korea
13 shared publications - Seonghee Kang
Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
11 shared publications - Yoonsuk Huh
Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
11 shared publications - Jin Jegal
Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
10 shared publications - Bo-Wi Cheon
Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
9 shared publications
Latest Publications
- Open Access
- 17 November 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (12)
Evaluation of a multifunctional phantom for geometric, image quality, and dosimetric constancy of megavoltage electronic portal imaging devices
Background: Routine quality assurance (QA) of linear accelerators and electronic portal imaging devices (EPIDs) often requires separate devices and acquisition procedures for geometric, image‐quality, radiation‐field, multileaf collimator (MLC), and dosimetric checks. A multifunctional phantom could consolidate these assessments within a single QA workflow. Purpose: To evaluate the week‐to‐week reproducibility of measurements obtained with MZ Slab, a multifunctional megavoltage EPID phantom, on three linear accelerators with different EPID configurations. Methods: Measurements were performed weekly for four weeks on TrueBeam STx, Halcyon, and Harmony Pro. Each session comprised three acquisition sets with phantom removal and repositioning between sets. The phantom provided measurements of geometric accuracy, image quality, material‐response isotropy, and radiation‐field size, together with qualitative MLC light‐field checks. Weekly values were summarized as mean and within‐session standard deviation, and changes were assessed relative to week 1. Field sizes were compared with open‐field EPID images and IC Profiler measurements. Dose‐calibrated portal images acquired on TrueBeam were compared with the week 1 image using mean response change and gamma passing rates. Results: Central‐marker offset ranged from 0.24 to 0.78 mm across units, with a maximum change from week 1 of 0.29 mm. Marker‐distance deviations changed by no more than 0.03 mm. The maximum changes in mean relative contrast transfer function and low‐contrast contrast‐to‐noise ratio were 0.011 (2.6%) and 1.81 (5.0%), respectively, relative to the week 1 baseline. Uniformity deviation and normalized noise changed by up to 0.50 and 0.17 percentage points, and material‐specific normalized response by up to 0.014. Field sizes changed by up to 0.56 mm and agreed with open‐field EPID measurements within 0.3 mm. IC Profiler values were 0.2–0.9 mm larger than MZ Slab values. MLC leaf ends remained within the printed ± 1 mm tolerance. At week 4, mean portal‐image response had increased by 0.77%, with a gamma passing rate of 99.65% at 1%/1 mm. Conclusions: MZ Slab supported geometric, image‐quality, radiation‐field, qualitative MLC, and portal‐dosimetry assessments within a single‐phantom QA workflow. Measurements on three linacs characterized within‐session reproducibility and week‐to‐week consistency over four weeks. Longer observation and deliberate perturbation testing are required to establish action limits and fault‐detection sensitivity.
- 17 November 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (12)
Open AccessEvaluation of a multifunctional phantom for geometric, image quality, and dosimetric constancy of megavoltage electronic portal imaging devices
Background: Routine quality assurance (QA) of linear accelerators and electronic portal imaging devices (EPIDs) often requires separate devices and acquisition procedures for geometric, image‐quality, radiation‐field, multileaf collimator (MLC), and dosimetric checks. A multifunctional phantom could consolidate these assessments within a single QA workflow. Purpose: To evaluate the week‐to‐week reproducibility of measurements obtained with MZ Slab, a multifunctional megavoltage EPID phantom, on three linear accelerators with different EPID configurations. Methods: Measurements were performed weekly for four weeks on TrueBeam STx, Halcyon, and Harmony Pro. Each session comprised three acquisition sets with phantom removal and repositioning between sets. The phantom provided measurements of geometric accuracy, image quality, material‐response isotropy, and radiation‐field size, together with qualitative MLC light‐field checks. Weekly values were summarized as mean and within‐session standard deviation, and changes were assessed relative to week 1. Field sizes were compared with open‐field EPID images and IC Profiler measurements. Dose‐calibrated portal images acquired on TrueBeam were compared with the week 1 image using mean response change and gamma passing rates. Results: Central‐marker offset ranged from 0.24 to 0.78 mm across units, with a maximum change from week 1 of 0.29 mm. Marker‐distance deviations changed by no more than 0.03 mm. The maximum changes in mean relative contrast transfer function and low‐contrast contrast‐to‐noise ratio were 0.011 (2.6%) and 1.81 (5.0%), respectively, relative to the week 1 baseline. Uniformity deviation and normalized noise changed by up to 0.50 and 0.17 percentage points, and material‐specific normalized response by up to 0.014. Field sizes changed by up to 0.56 mm and agreed with open‐field EPID measurements within 0.3 mm. IC Profiler values were 0.2–0.9 mm larger than MZ Slab values. MLC leaf ends remained within the printed ± 1 mm tolerance. At week 4, mean portal‐image response had increased by 0.77%, with a gamma passing rate of 99.65% at 1%/1 mm. Conclusions: MZ Slab supported geometric, image‐quality, radiation‐field, qualitative MLC, and portal‐dosimetry assessments within a single‐phantom QA workflow. Measurements on three linacs characterized within‐session reproducibility and week‐to‐week consistency over four weeks. Longer observation and deliberate perturbation testing are required to establish action limits and fault‐detection sensitivity.
- Open Access
- 30 September 2026
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 37 (3) , 89-107
Risk-Based Management of Patients with Cardiac Implantable Electronic Devices Underwent Radiation Therapy: A Practical Review
Na Hye Kwon, Inbum Lee, Euntaek Yoon, Bo-Wi Cheon, Young Jae Jang, Chang Heon Choi, Hyeongmin Jin, Jaeman Son, Jongmin Park, Jung-in Kim, Seonghee Kang, Sung Hyun Lee, Yoonsuk Huh. Progress in Medical Physics 2026;37:89-107. https://doi.org/10.14316/pmp.2026.37.3.89
- 30 September 2026
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 37 (3) , 89-107
Open AccessRisk-Based Management of Patients with Cardiac Implantable Electronic Devices Underwent Radiation Therapy: A Practical Review
Na Hye Kwon, Inbum Lee, Euntaek Yoon, Bo-Wi Cheon, Young Jae Jang, Chang Heon Choi, Hyeongmin Jin, Jaeman Son, Jongmin Park, Jung-in Kim, Seonghee Kang, Sung Hyun Lee, Yoonsuk Huh. Progress in Medical Physics 2026;37:89-107. https://doi.org/10.14316/pmp.2026.37.3.89
- 29 July 2026
- Published by Elsevier in Physica Medica
- Vol. 148
Technical evaluation of a multipurpose phantom for selected CBCT QA endpoints across linac platforms
- 29 July 2026
- Published by Elsevier in Physica Medica
- Vol. 148
Technical evaluation of a multipurpose phantom for selected CBCT QA endpoints across linac platforms
- Open Access
- 31 March 2026
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 37 (1) , 28-37
Prediction of Therapeutic and Imaging Doses in the Gonadal Shielding Block Using Monte Carlo Simulation
Sung Hyun Lee, Inbum Lee, Bo-Wi Cheon, Jin Jegal, Hyeongmin Jin, Jong Min Park, Chang Heon Choi, Jung-in Kim, Kyung Su Kim, Eui Kyu Chie, Seonghee Kang. Progress in Medical Physics 2026;37:28-37. https://doi.org/10.14316/pmp.2026.37.1.28
- 31 March 2026
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 37 (1) , 28-37
Open AccessPrediction of Therapeutic and Imaging Doses in the Gonadal Shielding Block Using Monte Carlo Simulation
Sung Hyun Lee, Inbum Lee, Bo-Wi Cheon, Jin Jegal, Hyeongmin Jin, Jong Min Park, Chang Heon Choi, Jung-in Kim, Kyung Su Kim, Eui Kyu Chie, Seonghee Kang. Progress in Medical Physics 2026;37:28-37. https://doi.org/10.14316/pmp.2026.37.1.28
- Open Access
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 100-107
Validation of Clinically Optimized Multi-Leaf Collimator Parameters Using Enhanced Leaf Modeling in the AcurosXB Algorithm
Jin Jegal, Yoonsuk Huh, Inbum Lee, Bo-Wi Cheon, Euntaek Yoon, Chang Heon Choi, Jung-in Kim, Seonghee Kang. Progress in Medical Physics 2025;36:100-7. https://doi.org/10.14316/pmp.2025.36.4.100
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 100-107
Open AccessValidation of Clinically Optimized Multi-Leaf Collimator Parameters Using Enhanced Leaf Modeling in the AcurosXB Algorithm
Jin Jegal, Yoonsuk Huh, Inbum Lee, Bo-Wi Cheon, Euntaek Yoon, Chang Heon Choi, Jung-in Kim, Seonghee Kang. Progress in Medical Physics 2025;36:100-7. https://doi.org/10.14316/pmp.2025.36.4.100
- Open Access
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 165-174
Performance Evaluation of the HyperSight Cone-Beam Computed Tomography System on the Halcyon Platform: Installation Acceptance and Quantitative Image Quality Assessment
Yoonsuk Huh, Euntaek Yoon, Jin Jegal, Inbum Lee, Bo-Wi Cheon, Jongmin Park, Jung-in Kim, Chang Heon Choi, Seonghee Kang, Sung Hyun Lee, Hyeongmin Jin, Jaeman Son. Progress in Medical Physics 2025;36:165-74. https://doi.org/10.14316/pmp.2025.36.4.165
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 165-174
Open AccessPerformance Evaluation of the HyperSight Cone-Beam Computed Tomography System on the Halcyon Platform: Installation Acceptance and Quantitative Image Quality Assessment
Yoonsuk Huh, Euntaek Yoon, Jin Jegal, Inbum Lee, Bo-Wi Cheon, Jongmin Park, Jung-in Kim, Chang Heon Choi, Seonghee Kang, Sung Hyun Lee, Hyeongmin Jin, Jaeman Son. Progress in Medical Physics 2025;36:165-74. https://doi.org/10.14316/pmp.2025.36.4.165
- Open Access
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 139-146
Clinical Validation of EPIbeam as a Patient-Specific Pre-Treatment Quality Assurance System
Euntaek Yoon, Inbum Lee, Yoonsuk Huh, Bo-Wi Cheon, Jin Jegal, Hyeongmin Jin, Sung Hyun Lee, Seonghee Kang, Chang Heon Choi, Jong Min Park, Jung-in Kim, Jaeman Son. Progress in Medical Physics 2025;36:139-46. https://doi.org/10.14316/pmp.2025.36.4.139
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 139-146
Open AccessClinical Validation of EPIbeam as a Patient-Specific Pre-Treatment Quality Assurance System
Euntaek Yoon, Inbum Lee, Yoonsuk Huh, Bo-Wi Cheon, Jin Jegal, Hyeongmin Jin, Sung Hyun Lee, Seonghee Kang, Chang Heon Choi, Jong Min Park, Jung-in Kim, Jaeman Son. Progress in Medical Physics 2025;36:139-46. https://doi.org/10.14316/pmp.2025.36.4.139
- Open Access
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 147-154
Head Leakage in Modern Clinical Linear Accelerators: A Multimachine Appraisal at Seoul National University Hospital
Inbum Lee, Euntaek Yoon, Bo-Wi Cheon, Jin Jegal, Yoonsuk Huh, Jong Min Park, Jung-in Kim, Chang Heon Choi, Seonghee Kang, Jaeman Son, Hyeongmin Jin, Sung Hyun Lee. Progress in Medical Physics 2025;36:147-54. https://doi.org/10.14316/pmp.2025.36.4.147
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 147-154
Open AccessHead Leakage in Modern Clinical Linear Accelerators: A Multimachine Appraisal at Seoul National University Hospital
Inbum Lee, Euntaek Yoon, Bo-Wi Cheon, Jin Jegal, Yoonsuk Huh, Jong Min Park, Jung-in Kim, Chang Heon Choi, Seonghee Kang, Jaeman Son, Hyeongmin Jin, Sung Hyun Lee. Progress in Medical Physics 2025;36:147-54. https://doi.org/10.14316/pmp.2025.36.4.147
- Open Access
- 30 September 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (3) , 61-69
Clinical Commissioning of a Ceiling-Mounted Spoiler for Total Body Irradiation
Jin Jegal, Yoonsuk Huh, Inbum Lee, Bo-Wi Cheon, Euntaek Yoon, Seonghee Kang, Jaeman Son, Sung Hyun Lee, Chang Heon Choi, Jung-in Kim, Hyeongmin Jin. Progress in Medical Physics 2025;36:61-39. https://doi.org/10.14316/pmp.2025.36.3.61
- 30 September 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (3) , 61-69
Open AccessClinical Commissioning of a Ceiling-Mounted Spoiler for Total Body Irradiation
Jin Jegal, Yoonsuk Huh, Inbum Lee, Bo-Wi Cheon, Euntaek Yoon, Seonghee Kang, Jaeman Son, Sung Hyun Lee, Chang Heon Choi, Jung-in Kim, Hyeongmin Jin. Progress in Medical Physics 2025;36:61-39. https://doi.org/10.14316/pmp.2025.36.3.61
- Open Access
- 30 June 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (2) , 38-44
Comparative Evaluation of the Volumetric Effects on Chemical Yield in Monte Carlo Computational Approaches
Euntaek Yoon, Bo-Wi Cheon, Inbum Lee, Yoonsuk Huh, Jin Jegal, Seonghee Kang, Jung-in Kim, Chang Heon Choi. Progress in Medical Physics 2025;36:38-44. https://doi.org/10.14316/pmp.2025.36.2.38
- 30 June 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (2) , 38-44
Open AccessComparative Evaluation of the Volumetric Effects on Chemical Yield in Monte Carlo Computational Approaches
Euntaek Yoon, Bo-Wi Cheon, Inbum Lee, Yoonsuk Huh, Jin Jegal, Seonghee Kang, Jung-in Kim, Chang Heon Choi. Progress in Medical Physics 2025;36:38-44. https://doi.org/10.14316/pmp.2025.36.2.38