Seonghee Kang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Seonghee Kang has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Chang Heon Choi
Department of Radiation Oncology Seoul National University Hospital Seoul Republic of Korea
22 shared publications - Jung-In Kim
Department of Radiation Oncology Seoul National University Hospital Seoul Republic of Korea
20 shared publications - Jin Jegal
Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
13 shared publications - Hyeongmin Jin
Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
11 shared publications - Inbum Lee
Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
11 shared publications - Yoonsuk Huh
Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea
11 shared publications
Latest Publications
- Open Access
- 30 September 2026
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 37 (3) , 89-107
Risk-Based Management of Patients with Cardiac Implantable Electronic Devices Underwent Radiation Therapy: A Practical Review
Na Hye Kwon, Inbum Lee, Euntaek Yoon, Bo-Wi Cheon, Young Jae Jang, Chang Heon Choi, Hyeongmin Jin, Jaeman Son, Jongmin Park, Jung-in Kim, Seonghee Kang, Sung Hyun Lee, Yoonsuk Huh. Progress in Medical Physics 2026;37:89-107. https://doi.org/10.14316/pmp.2026.37.3.89
- 30 September 2026
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 37 (3) , 89-107
Open AccessRisk-Based Management of Patients with Cardiac Implantable Electronic Devices Underwent Radiation Therapy: A Practical Review
Na Hye Kwon, Inbum Lee, Euntaek Yoon, Bo-Wi Cheon, Young Jae Jang, Chang Heon Choi, Hyeongmin Jin, Jaeman Son, Jongmin Park, Jung-in Kim, Seonghee Kang, Sung Hyun Lee, Yoonsuk Huh. Progress in Medical Physics 2026;37:89-107. https://doi.org/10.14316/pmp.2026.37.3.89
- 21 August 2026
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 99 (1187) , 2261-2265
Comparison of 4 CBCT-IGRT geometric QA phantoms within a single institutional workflow
Objectives: To compare 4 commercial cone-beam CT (CBCT) geometric quality assurance phantoms within a common workflow, focusing on positioning/repositioning accuracy and agreement between the laser-defined setup reference and the CBCT imaging isocenter. Methods: MIMI, QUASAR Penta-Guide, ISOCube, and MZ CUBE were evaluated monthly for 5 months on a Versa HD system with XVI CBCT and a HexaPOD couch. Two observers independently completed each measurement. Three-dimensional post-correction translational residuals (Δdpos/rep) and laser-defined setup reference-CBCT imaging isocenter distances (Δdiso) were calculated. Phantom comparisons used observer-averaged values from the 5 monthly sessions. Rotational correction and CBCT image quality were assessed descriptively with MZ CUBE. Results: Mean Δdpos/rep values ranged from 0.19 to 0.31 mm, with mean absolute observer differences of 0.05-0.12 mm. No overall difference was found among the 4 phantoms (P = .547). Mean Δdiso values ranged from 0.68 to 0.87 mm, and all measurements were below 2 mm. An overall difference was observed for Δdiso (P = .019), although no pairwise comparisons were performed. With MZ CUBE, mean post-correction translational and rotational residuals were 0.24 mm and 0.37°, respectively, and image-quality measures showed no consistent temporal trend. Conclusions: The 4 phantoms showed similarly small post-correction translational residuals. In our setting, MZ CUBE additionally supported rotational and image-quality checks. Advances in knowledge: Direct comparison within a common workflow showed similar translational performance, while the scope of additional testing depended on the phantom configuration and locally available accessories.
- 21 August 2026
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 99 (1187) , 2261-2265
Comparison of 4 CBCT-IGRT geometric QA phantoms within a single institutional workflow
Objectives: To compare 4 commercial cone-beam CT (CBCT) geometric quality assurance phantoms within a common workflow, focusing on positioning/repositioning accuracy and agreement between the laser-defined setup reference and the CBCT imaging isocenter. Methods: MIMI, QUASAR Penta-Guide, ISOCube, and MZ CUBE were evaluated monthly for 5 months on a Versa HD system with XVI CBCT and a HexaPOD couch. Two observers independently completed each measurement. Three-dimensional post-correction translational residuals (Δdpos/rep) and laser-defined setup reference-CBCT imaging isocenter distances (Δdiso) were calculated. Phantom comparisons used observer-averaged values from the 5 monthly sessions. Rotational correction and CBCT image quality were assessed descriptively with MZ CUBE. Results: Mean Δdpos/rep values ranged from 0.19 to 0.31 mm, with mean absolute observer differences of 0.05-0.12 mm. No overall difference was found among the 4 phantoms (P = .547). Mean Δdiso values ranged from 0.68 to 0.87 mm, and all measurements were below 2 mm. An overall difference was observed for Δdiso (P = .019), although no pairwise comparisons were performed. With MZ CUBE, mean post-correction translational and rotational residuals were 0.24 mm and 0.37°, respectively, and image-quality measures showed no consistent temporal trend. Conclusions: The 4 phantoms showed similarly small post-correction translational residuals. In our setting, MZ CUBE additionally supported rotational and image-quality checks. Advances in knowledge: Direct comparison within a common workflow showed similar translational performance, while the scope of additional testing depended on the phantom configuration and locally available accessories.
- Open Access
- 31 March 2026
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 37 (1) , 28-37
Prediction of Therapeutic and Imaging Doses in the Gonadal Shielding Block Using Monte Carlo Simulation
Sung Hyun Lee, Inbum Lee, Bo-Wi Cheon, Jin Jegal, Hyeongmin Jin, Jong Min Park, Chang Heon Choi, Jung-in Kim, Kyung Su Kim, Eui Kyu Chie, Seonghee Kang. Progress in Medical Physics 2026;37:28-37. https://doi.org/10.14316/pmp.2026.37.1.28
- 31 March 2026
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 37 (1) , 28-37
Open AccessPrediction of Therapeutic and Imaging Doses in the Gonadal Shielding Block Using Monte Carlo Simulation
Sung Hyun Lee, Inbum Lee, Bo-Wi Cheon, Jin Jegal, Hyeongmin Jin, Jong Min Park, Chang Heon Choi, Jung-in Kim, Kyung Su Kim, Eui Kyu Chie, Seonghee Kang. Progress in Medical Physics 2026;37:28-37. https://doi.org/10.14316/pmp.2026.37.1.28
- Open Access
- 17 March 2026
- Published by Springer Nature in Radiation Oncology
- Vol. 21 (1)
Dose calculation accuracy with extended CT scales near metal: phantom–patient evaluation using a beam–metal overlap metric
We evaluated whether 16-bit CT reconstruction with explicit CT-to-electron-density (CT-to-ED) calibration improves dose-calculation accuracy versus conventional 12-bit reconstruction in the presence of metallic implants, and whether geometric metrics can identify cases that benefit most. CT-to-ED tables were built for both bit depths. In Solid Water, dose profiles and absolute dose were compared against EBT4 film and TG-51 ion-chamber measurements. Eight clinical IMRT plans were optimized and cross-recalculated between bit-depth domains with segments and monitor units fixed. A beam–metal interaction metric, ηmetal (monitor-unit–weighted beam’s-eye-view overlap), and the volumetric overlap ratio (VOR) between metal and PTV were computed. Gamma passing rate (GPR, 3 mm/3%), mean gamma, profile error, and absolute-dose deviation were evaluated. In the phantom, 16-bit improved agreement over 12-bit, yielding higher GPR, profile differences ≤ 2%, and absolute-dose errors ≤ 1.0%; 12-bit showed profile errors up to 5.4% (stainless steel) and 3.0% (titanium) and absolute-dose errors of 2.3% and 1.7%. In patients, ηmetal > 35% was associated with GPR < 90% when 12-bit plans were recalculated on 16-bit, whereas low ηmetal maintained ≥ 90%. ηmetal correlated positively with VOR and negatively with GPR, supporting pre-treatment triage via VOR. Extended-bit reconstruction mitigates HU saturation, improves RED assignment, and yields better agreement with measurements and calculation. These findings support adopting 16-bit CT with CT-to-ED calibration as the default for planning and verification in patients with metallic implants, with VOR or ηmetal flagging cases where benefit is greatest. The online version contains supplementary material available at 10.1186/s13014-026-02828-7.
- 17 March 2026
- Published by Springer Nature in Radiation Oncology
- Vol. 21 (1)
Open AccessDose calculation accuracy with extended CT scales near metal: phantom–patient evaluation using a beam–metal overlap metric
We evaluated whether 16-bit CT reconstruction with explicit CT-to-electron-density (CT-to-ED) calibration improves dose-calculation accuracy versus conventional 12-bit reconstruction in the presence of metallic implants, and whether geometric metrics can identify cases that benefit most. CT-to-ED tables were built for both bit depths. In Solid Water, dose profiles and absolute dose were compared against EBT4 film and TG-51 ion-chamber measurements. Eight clinical IMRT plans were optimized and cross-recalculated between bit-depth domains with segments and monitor units fixed. A beam–metal interaction metric, ηmetal (monitor-unit–weighted beam’s-eye-view overlap), and the volumetric overlap ratio (VOR) between metal and PTV were computed. Gamma passing rate (GPR, 3 mm/3%), mean gamma, profile error, and absolute-dose deviation were evaluated. In the phantom, 16-bit improved agreement over 12-bit, yielding higher GPR, profile differences ≤ 2%, and absolute-dose errors ≤ 1.0%; 12-bit showed profile errors up to 5.4% (stainless steel) and 3.0% (titanium) and absolute-dose errors of 2.3% and 1.7%. In patients, ηmetal > 35% was associated with GPR < 90% when 12-bit plans were recalculated on 16-bit, whereas low ηmetal maintained ≥ 90%. ηmetal correlated positively with VOR and negatively with GPR, supporting pre-treatment triage via VOR. Extended-bit reconstruction mitigates HU saturation, improves RED assignment, and yields better agreement with measurements and calculation. These findings support adopting 16-bit CT with CT-to-ED calibration as the default for planning and verification in patients with metallic implants, with VOR or ηmetal flagging cases where benefit is greatest. The online version contains supplementary material available at 10.1186/s13014-026-02828-7.
- Open Access
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 100-107
Validation of Clinically Optimized Multi-Leaf Collimator Parameters Using Enhanced Leaf Modeling in the AcurosXB Algorithm
Jin Jegal, Yoonsuk Huh, Inbum Lee, Bo-Wi Cheon, Euntaek Yoon, Chang Heon Choi, Jung-in Kim, Seonghee Kang. Progress in Medical Physics 2025;36:100-7. https://doi.org/10.14316/pmp.2025.36.4.100
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 100-107
Open AccessValidation of Clinically Optimized Multi-Leaf Collimator Parameters Using Enhanced Leaf Modeling in the AcurosXB Algorithm
Jin Jegal, Yoonsuk Huh, Inbum Lee, Bo-Wi Cheon, Euntaek Yoon, Chang Heon Choi, Jung-in Kim, Seonghee Kang. Progress in Medical Physics 2025;36:100-7. https://doi.org/10.14316/pmp.2025.36.4.100
- Open Access
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 165-174
Performance Evaluation of the HyperSight Cone-Beam Computed Tomography System on the Halcyon Platform: Installation Acceptance and Quantitative Image Quality Assessment
Yoonsuk Huh, Euntaek Yoon, Jin Jegal, Inbum Lee, Bo-Wi Cheon, Jongmin Park, Jung-in Kim, Chang Heon Choi, Seonghee Kang, Sung Hyun Lee, Hyeongmin Jin, Jaeman Son. Progress in Medical Physics 2025;36:165-74. https://doi.org/10.14316/pmp.2025.36.4.165
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 165-174
Open AccessPerformance Evaluation of the HyperSight Cone-Beam Computed Tomography System on the Halcyon Platform: Installation Acceptance and Quantitative Image Quality Assessment
Yoonsuk Huh, Euntaek Yoon, Jin Jegal, Inbum Lee, Bo-Wi Cheon, Jongmin Park, Jung-in Kim, Chang Heon Choi, Seonghee Kang, Sung Hyun Lee, Hyeongmin Jin, Jaeman Son. Progress in Medical Physics 2025;36:165-74. https://doi.org/10.14316/pmp.2025.36.4.165
- Open Access
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 139-146
Clinical Validation of EPIbeam as a Patient-Specific Pre-Treatment Quality Assurance System
Euntaek Yoon, Inbum Lee, Yoonsuk Huh, Bo-Wi Cheon, Jin Jegal, Hyeongmin Jin, Sung Hyun Lee, Seonghee Kang, Chang Heon Choi, Jong Min Park, Jung-in Kim, Jaeman Son. Progress in Medical Physics 2025;36:139-46. https://doi.org/10.14316/pmp.2025.36.4.139
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 139-146
Open AccessClinical Validation of EPIbeam as a Patient-Specific Pre-Treatment Quality Assurance System
Euntaek Yoon, Inbum Lee, Yoonsuk Huh, Bo-Wi Cheon, Jin Jegal, Hyeongmin Jin, Sung Hyun Lee, Seonghee Kang, Chang Heon Choi, Jong Min Park, Jung-in Kim, Jaeman Son. Progress in Medical Physics 2025;36:139-46. https://doi.org/10.14316/pmp.2025.36.4.139
- Open Access
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 147-154
Head Leakage in Modern Clinical Linear Accelerators: A Multimachine Appraisal at Seoul National University Hospital
Inbum Lee, Euntaek Yoon, Bo-Wi Cheon, Jin Jegal, Yoonsuk Huh, Jong Min Park, Jung-in Kim, Chang Heon Choi, Seonghee Kang, Jaeman Son, Hyeongmin Jin, Sung Hyun Lee. Progress in Medical Physics 2025;36:147-54. https://doi.org/10.14316/pmp.2025.36.4.147
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 147-154
Open AccessHead Leakage in Modern Clinical Linear Accelerators: A Multimachine Appraisal at Seoul National University Hospital
Inbum Lee, Euntaek Yoon, Bo-Wi Cheon, Jin Jegal, Yoonsuk Huh, Jong Min Park, Jung-in Kim, Chang Heon Choi, Seonghee Kang, Jaeman Son, Hyeongmin Jin, Sung Hyun Lee. Progress in Medical Physics 2025;36:147-54. https://doi.org/10.14316/pmp.2025.36.4.147
- Open Access
- 30 September 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (3) , 61-69
Clinical Commissioning of a Ceiling-Mounted Spoiler for Total Body Irradiation
Jin Jegal, Yoonsuk Huh, Inbum Lee, Bo-Wi Cheon, Euntaek Yoon, Seonghee Kang, Jaeman Son, Sung Hyun Lee, Chang Heon Choi, Jung-in Kim, Hyeongmin Jin. Progress in Medical Physics 2025;36:61-39. https://doi.org/10.14316/pmp.2025.36.3.61
- 30 September 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (3) , 61-69
Open AccessClinical Commissioning of a Ceiling-Mounted Spoiler for Total Body Irradiation
Jin Jegal, Yoonsuk Huh, Inbum Lee, Bo-Wi Cheon, Euntaek Yoon, Seonghee Kang, Jaeman Son, Sung Hyun Lee, Chang Heon Choi, Jung-in Kim, Hyeongmin Jin. Progress in Medical Physics 2025;36:61-39. https://doi.org/10.14316/pmp.2025.36.3.61