Wei Tian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wei Tian has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Jifang Tao
School of Information Science and Engineering, Shandong University, Qingdao 266237, China
6 shared publications - Yuzhe Lin
College of Electronics and Information, Qingdao University, Qingdao, China
5 shared publications - Maosen Xu
College of Electrical Engineering and Automation, Shandong University of Science and Technology, Qingdao 266590, China
4 shared publications - Jinghua Lin
School of Information Science and Engineering, Shandong University, Qingdao, China
3 shared publications - Hanzhe Liu
School of Information Science and Engineering, Shandong University, Qingdao, China
2 shared publications Hong Zhou
Science and Technology on Microsystem Laboratory, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, China
2 shared publications
Latest Publications
- 21 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-12
Hybrid Modeling and Experimental Validation for Gas Factor Determination in a MEMS Thermal Flow Meter
Undetermined gas factors of micro-electro-mechanical systems (MEMS) thermal mass flow meters (MFMs) constitute a critical bottleneck limiting their industrial adoption, particularly in semiconductor manufacturing. This limitation stems from current manufacturing practices, where only N2-calibrated products are mass-produced, whereas real-world applications require gas factor switching for multigas measurement. To address this challenge, this work presents a porous silicon-based MEMS thermal MFM and proposes a corresponding gas factor determination method using a hybrid modeling-experimental approach. The implementation involves: derivation of mathematical correlations among the output signal, gas flow rate, and thermophysical parameters via constitutive modeling, followed by empirical correction of model exponents using experimental datasets. The gas factors derived from this relationship were empirically validated using six test gases under constant ambient conditions. The results demonstrate high effectiveness, with all observed absolute errors confined within 6.4%FS, and exhibit excellent consistency. This work provides a practical methodology for gas factor determination in MEMS thermal MFMs, addressing a major limitation that restricts their universality in multigas measurement.
- 21 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-12
Hybrid Modeling and Experimental Validation for Gas Factor Determination in a MEMS Thermal Flow Meter
Undetermined gas factors of micro-electro-mechanical systems (MEMS) thermal mass flow meters (MFMs) constitute a critical bottleneck limiting their industrial adoption, particularly in semiconductor manufacturing. This limitation stems from current manufacturing practices, where only N2-calibrated products are mass-produced, whereas real-world applications require gas factor switching for multigas measurement. To address this challenge, this work presents a porous silicon-based MEMS thermal MFM and proposes a corresponding gas factor determination method using a hybrid modeling-experimental approach. The implementation involves: derivation of mathematical correlations among the output signal, gas flow rate, and thermophysical parameters via constitutive modeling, followed by empirical correction of model exponents using experimental datasets. The gas factors derived from this relationship were empirically validated using six test gases under constant ambient conditions. The results demonstrate high effectiveness, with all observed absolute errors confined within 6.4%FS, and exhibit excellent consistency. This work provides a practical methodology for gas factor determination in MEMS thermal MFMs, addressing a major limitation that restricts their universality in multigas measurement.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 46 (7) , 1207-1210
NH₃-Targeted Corrosion-Resistant MEMS Calorimetric Flow Sensor Based on Parylene C
This letter presents a corrosion-resistant MEMS calorimetric flow sensor that addresses reliability challenges in ammonia (NH3) flow measurement. The employment of Parylene C anti-corrosion coating extends the sensor’s stability in 25 wt% ammonia solution to over 168 hours, demonstrating enhanced resistance to alkaline corrosion. Additionally, compared with suspended membrane designs, the adoption of porous silicon thermal isolation structure reduces the zero-flow voltage difference when measuring NH3 versus N2 from 2.02%FS to 0.07%FS, enabling mass production using an N2-calibration scheme. The experimental results demonstrate the sensor’s potential for replacing capillary-based flow sensors in semiconductor manufacturing.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 46 (7) , 1207-1210
NH₃-Targeted Corrosion-Resistant MEMS Calorimetric Flow Sensor Based on Parylene C
This letter presents a corrosion-resistant MEMS calorimetric flow sensor that addresses reliability challenges in ammonia (NH3) flow measurement. The employment of Parylene C anti-corrosion coating extends the sensor’s stability in 25 wt% ammonia solution to over 168 hours, demonstrating enhanced resistance to alkaline corrosion. Additionally, compared with suspended membrane designs, the adoption of porous silicon thermal isolation structure reduces the zero-flow voltage difference when measuring NH3 versus N2 from 2.02%FS to 0.07%FS, enabling mass production using an N2-calibration scheme. The experimental results demonstrate the sensor’s potential for replacing capillary-based flow sensors in semiconductor manufacturing.
- 16 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. PP (10577157) , 1-10
Development of a MEMS Thermal Flow Sensor With High Reliability and Universality for Various Gases
This paper presents an improved calorimetric MEMS flow sensor to meet the needs of large-scale industrial applications such as semiconductor and photovoltaics. Reliability and universality are considered the most critical factors for these fields, for which the porous silicon-based sensor was designed, fabricated and tested rigorously with eight gases. The results demonstrated that the sensor maintained nearly identical zero-flow outputs across various static gas environments (using N2 as the baseline, with deviations ranging from 0.01%FS for CO to 0.69%FS for He). Moreover, well-defined conversion coefficients were established between any two gases. This characteristic enables the practical application of N2-calibrated sensors to other gases through coefficient conversion, achieving an accuracy error within 2.0%FS. In addition, the sensor can survive and maintain its sensing capabilities even during continuous SiH4 combustion reactions and under heavy pollution, whereas the suspended membrane-based sensor ruptures. This innovative work makes MEMS flow sensors more convenient and reliable in complex industrial applications, potentially replacing traditional flow sensors based on capillary structures.[2025-0009]
- 16 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. PP (10577157) , 1-10
Development of a MEMS Thermal Flow Sensor With High Reliability and Universality for Various Gases
This paper presents an improved calorimetric MEMS flow sensor to meet the needs of large-scale industrial applications such as semiconductor and photovoltaics. Reliability and universality are considered the most critical factors for these fields, for which the porous silicon-based sensor was designed, fabricated and tested rigorously with eight gases. The results demonstrated that the sensor maintained nearly identical zero-flow outputs across various static gas environments (using N2 as the baseline, with deviations ranging from 0.01%FS for CO to 0.69%FS for He). Moreover, well-defined conversion coefficients were established between any two gases. This characteristic enables the practical application of N2-calibrated sensors to other gases through coefficient conversion, achieving an accuracy error within 2.0%FS. In addition, the sensor can survive and maintain its sensing capabilities even during continuous SiH4 combustion reactions and under heavy pollution, whereas the suspended membrane-based sensor ruptures. This innovative work makes MEMS flow sensors more convenient and reliable in complex industrial applications, potentially replacing traditional flow sensors based on capillary structures.[2025-0009]
- Open Access
- 28 September 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (10) , 1203
Development of a Compact NDIR CO2 Gas Sensor for a Portable Gas Analyzer
A carbon dioxide (CO2) gas sensor based on non-dispersive infrared (NDIR) technology has been developed and is suitable for use in portable devices for high-precision CO2 detection. The NDIR gas sensor comprises a MEMS infrared emitter, a MEMS thermopile detector with an integrated optical filter, and a compact gas cell with high optical coupling efficiency. A dual-ellipsoid mirror optical system was designed, and based on optical simulation analysis, the structure of the dual-ellipsoid reflective gas chamber was designed and optimized, achieving a coupling efficiency of up to 54%. Optical and thermal simulations were conducted to design the sensor structure, considering thermal management and light analysis. By optimizing the gas cell structure and conditioning circuit, we effectively reduced the sensor’s baseline noise, enhancing the overall reliability and stability of the system. The sensor’s dimensions were 20 mm × 10 mm × 4 mm (L × W × H), only 15% of the size of traditional NDIR gas sensors with equivalent detection resolution. The developed sensor offers high sensitivity and low noise, with a sensitivity of 15 μV/ppm, a detection limit of 90 ppm, and a resolution of 30 ppm. The total power consumption of the whole sensor system is 6.5 mW, with a maximum power consumption of only 90 mW.
- 28 September 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (10) , 1203
Open AccessDevelopment of a Compact NDIR CO2 Gas Sensor for a Portable Gas Analyzer
A carbon dioxide (CO2) gas sensor based on non-dispersive infrared (NDIR) technology has been developed and is suitable for use in portable devices for high-precision CO2 detection. The NDIR gas sensor comprises a MEMS infrared emitter, a MEMS thermopile detector with an integrated optical filter, and a compact gas cell with high optical coupling efficiency. A dual-ellipsoid mirror optical system was designed, and based on optical simulation analysis, the structure of the dual-ellipsoid reflective gas chamber was designed and optimized, achieving a coupling efficiency of up to 54%. Optical and thermal simulations were conducted to design the sensor structure, considering thermal management and light analysis. By optimizing the gas cell structure and conditioning circuit, we effectively reduced the sensor’s baseline noise, enhancing the overall reliability and stability of the system. The sensor’s dimensions were 20 mm × 10 mm × 4 mm (L × W × H), only 15% of the size of traditional NDIR gas sensors with equivalent detection resolution. The developed sensor offers high sensitivity and low noise, with a sensitivity of 15 μV/ppm, a detection limit of 90 ppm, and a resolution of 30 ppm. The total power consumption of the whole sensor system is 6.5 mW, with a maximum power consumption of only 90 mW.
- 19 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (21) , 35508-35515
Development of a Nonresonant Photoacoustic Gas Sensor for Ozone Detection
A non-resonant photoacoustic effect-based ozone (O 3 ) gas sensor has been developed, with the potential for O 3 concentration monitoring in various fields, including the semiconductor industry, water treatment, and O 3 environmental science research. This sensor comprises a micro-electromechanical system (MEMS) emitter, a miniature photoacoustic cell, a MEMS microphone, and a circuit. By establishing a three-dimensional model and simulating the impact of structural parameters on sensor performance, this comprehensive approach successfully determined the optimal structural parameters. The sensor has a footprint of approximately 12 mm×12 mm ×5 mm (L×W×H), which is 10% of the size of traditional non-dispersive infrared gas sensors. The sensor achieves an accuracy of ±50 ppm within an O 3 concentration range of 0% to 4%. The response time ( t 100 ) is 57 s, and the detection limit (LOD) for O 3 concentration is 36 ppm.
- 19 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (21) , 35508-35515
Development of a Nonresonant Photoacoustic Gas Sensor for Ozone Detection
A non-resonant photoacoustic effect-based ozone (O 3 ) gas sensor has been developed, with the potential for O 3 concentration monitoring in various fields, including the semiconductor industry, water treatment, and O 3 environmental science research. This sensor comprises a micro-electromechanical system (MEMS) emitter, a miniature photoacoustic cell, a MEMS microphone, and a circuit. By establishing a three-dimensional model and simulating the impact of structural parameters on sensor performance, this comprehensive approach successfully determined the optimal structural parameters. The sensor has a footprint of approximately 12 mm×12 mm ×5 mm (L×W×H), which is 10% of the size of traditional non-dispersive infrared gas sensors. The sensor achieves an accuracy of ±50 ppm within an O 3 concentration range of 0% to 4%. The response time ( t 100 ) is 57 s, and the detection limit (LOD) for O 3 concentration is 36 ppm.
- 25 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (2) , 2099-2106
Micromachined Thermocouple for Rapid Detection of Ultrahigh Heat Flux at High Temperature
This article presents a novel high temperature heat flux (HTHF) sensor based on micromachined thermocouple (MTC) to meet the needs of transient high heat flux detection in ultrahigh temperature environments, such as fire research, high-power pulsed lasers testing, and aerospace engineering. The targeted design, fabrication, and package of an MTC-based HTHF sensor with excellent heat dissipation capacity are proposed, and relevant experiments were conducted in two aspects. First, powerful laser tube-based tests at ambient temperature show that such a sensor can detect a heat flux high to 10.8 MW/m 2 with an extremely fast response; its response time, in this case, is 1.9 ms. And then, turbine engine test pipe based tests at high temperature reveal that the sensor with water cooling could survive at 1200 °C for at least 100 s. Compared to conventional heat flux sensors, it is more sensitive to transient heat flux changes and has a faster response speed. Such satisfactory performance makes the sensor extremely competitive in ultrahigh heat flux detection in extremely harsh environments.
- 25 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (2) , 2099-2106
Micromachined Thermocouple for Rapid Detection of Ultrahigh Heat Flux at High Temperature
This article presents a novel high temperature heat flux (HTHF) sensor based on micromachined thermocouple (MTC) to meet the needs of transient high heat flux detection in ultrahigh temperature environments, such as fire research, high-power pulsed lasers testing, and aerospace engineering. The targeted design, fabrication, and package of an MTC-based HTHF sensor with excellent heat dissipation capacity are proposed, and relevant experiments were conducted in two aspects. First, powerful laser tube-based tests at ambient temperature show that such a sensor can detect a heat flux high to 10.8 MW/m 2 with an extremely fast response; its response time, in this case, is 1.9 ms. And then, turbine engine test pipe based tests at high temperature reveal that the sensor with water cooling could survive at 1200 °C for at least 100 s. Compared to conventional heat flux sensors, it is more sensitive to transient heat flux changes and has a faster response speed. Such satisfactory performance makes the sensor extremely competitive in ultrahigh heat flux detection in extremely harsh environments.
- 21 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (1) , 36-42
Micromachined Thermopile Based High Heat Flux Sensor
Transient heat flux sensors are widely used in unsteady thermal analyses. Commercial sensors currently available for high heat flux, however, have relatively low sensitivity. Micromachined thermopile based sensors with advantages of high sensitivity and small size, have been used for the measurement of heat flux produced by black body (usually in the level of W/m²), but not been tried to measure a heat flux on the order of MW/m². In this paper, a high heat flux sensor based on structure-enhanced micromachined thermopile is careful designed and fabricated. Experiments using a powerful laser were conducted at ambient temperature to study the general performance, as well as the limit heat flux, of the sensor. The results show that the output signals have a linear characteristic with heat flux from 0.12 to 1.10 MW/m². The sensitivity and response time of the sensor are 1.50x 10⁻⁶ Vm²/W and 14 ms at 0.12 MW/m², respectively. The sensor exhibits excellent repeatability in more than 200 laser pulses at 0.44 MW/m². Limit check reveals that the sensor remains a good repeatability at 0.77 MW/m² and can survive at 1.10 MW/m². The designed sensor shows a high performance and will provide a new effective path for measuring high heat flux fast and sensitively. [2019-0160]
- 21 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 29 (1) , 36-42
Micromachined Thermopile Based High Heat Flux Sensor
Transient heat flux sensors are widely used in unsteady thermal analyses. Commercial sensors currently available for high heat flux, however, have relatively low sensitivity. Micromachined thermopile based sensors with advantages of high sensitivity and small size, have been used for the measurement of heat flux produced by black body (usually in the level of W/m²), but not been tried to measure a heat flux on the order of MW/m². In this paper, a high heat flux sensor based on structure-enhanced micromachined thermopile is careful designed and fabricated. Experiments using a powerful laser were conducted at ambient temperature to study the general performance, as well as the limit heat flux, of the sensor. The results show that the output signals have a linear characteristic with heat flux from 0.12 to 1.10 MW/m². The sensitivity and response time of the sensor are 1.50x 10⁻⁶ Vm²/W and 14 ms at 0.12 MW/m², respectively. The sensor exhibits excellent repeatability in more than 200 laser pulses at 0.44 MW/m². Limit check reveals that the sensor remains a good repeatability at 0.77 MW/m² and can survive at 1.10 MW/m². The designed sensor shows a high performance and will provide a new effective path for measuring high heat flux fast and sensitively. [2019-0160]