Jian Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jian Zhang has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Tao Zhang
College of Mechanical and Electrical Engineering, Northeast Forestry University, Harbin 150040, China
5 shared publications - Yuhang Wang
College of Mechanical and Electrical Engineering, Northeast Forestry University, Harbin 150040, China
5 shared publications Jihai Jiang
School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, China
3 shared publications- Jinghui Zhang
Mechanical and Electrical Engineering College, Northeast Forestry University, Harbin 150040, China
2 shared publications - Kai Yang
Mechanical and Electrical Engineering College, Northeast Forestry University, Harbin 150040, China
2 shared publications Naiming Qi
School of Astronautics, Harbin Institute of Technology, Harbin, China
2 shared publications
Latest Publications
- 29 August 2026
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
HEMODYNAMIC ALTERATIONS IN THORACIC AORTIC ANEURYSM: INSIGHTS FROM PATIENT-SPECIFIC COMPUTATIONAL SIMULATIONS WITH ANATOMICAL CONTROLS
The pathological progression of thoracic aortic aneurysm (TAA) is strongly coupled with hemodynamic abnormalities, which are difficult to quantify using traditional medical imaging. To address this, this study proposes a patient-specific modeling-simulation-decision analysis framework based on multimodal image fusion. A three-dimensional geometric model of the TAA was reconstructed from the patient CTA data, and a corresponding healthy thoracic aortic model was generated as an internal control using a geometric repair algorithm. Computational fluid dynamics (CFD) was then employed to systematically compare their hemodynamic characteristics over the entire cardiac cycle. The results revealed that, compared to the normal vessel, the aneurysmal region exhibited significantly lower flow velocity ([Formula: see text] [Formula: see text]m/s), with a disordered flow field characterized by multiple vortex structures. Furthermore, this region demonstrated an abnormal biomechanical environment, including low time-averaged wall shear stress (TAWSS[Formula: see text]0.5 Pa) and high relative residence time (RRT[Formula: see text]12). These parametric features showed a significant positive correlation with endothelial dysfunction and thrombogenic risk. Additionally, at peak systolic ejection, wall pressure in the aneurysm reached its maximum, which was 1.6% higher than in the normal vessel and exhibited a phase-lag phenomenon, suggesting an elevated rupture risk. By establishing a systematic comparative framework between TAA and normal thoracic aortas, this study provides an important theoretical basis and an analytical tool for elucidating the underlying hemodynamic mechanisms and assisting in clinical risk assessment and treatment strategy formulation.
- 29 August 2026
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
HEMODYNAMIC ALTERATIONS IN THORACIC AORTIC ANEURYSM: INSIGHTS FROM PATIENT-SPECIFIC COMPUTATIONAL SIMULATIONS WITH ANATOMICAL CONTROLS
The pathological progression of thoracic aortic aneurysm (TAA) is strongly coupled with hemodynamic abnormalities, which are difficult to quantify using traditional medical imaging. To address this, this study proposes a patient-specific modeling-simulation-decision analysis framework based on multimodal image fusion. A three-dimensional geometric model of the TAA was reconstructed from the patient CTA data, and a corresponding healthy thoracic aortic model was generated as an internal control using a geometric repair algorithm. Computational fluid dynamics (CFD) was then employed to systematically compare their hemodynamic characteristics over the entire cardiac cycle. The results revealed that, compared to the normal vessel, the aneurysmal region exhibited significantly lower flow velocity ([Formula: see text] [Formula: see text]m/s), with a disordered flow field characterized by multiple vortex structures. Furthermore, this region demonstrated an abnormal biomechanical environment, including low time-averaged wall shear stress (TAWSS[Formula: see text]0.5 Pa) and high relative residence time (RRT[Formula: see text]12). These parametric features showed a significant positive correlation with endothelial dysfunction and thrombogenic risk. Additionally, at peak systolic ejection, wall pressure in the aneurysm reached its maximum, which was 1.6% higher than in the normal vessel and exhibited a phase-lag phenomenon, suggesting an elevated rupture risk. By establishing a systematic comparative framework between TAA and normal thoracic aortas, this study provides an important theoretical basis and an analytical tool for elucidating the underlying hemodynamic mechanisms and assisting in clinical risk assessment and treatment strategy formulation.
- Open Access
Interpretable Acoustic-Emission Leak Detection and ED+MLE-Based Regional Localization in Thin Aluminum-Alloy Plates Under Vacuum Pressure-Difference Excitation
Continuous gas leakage in thin-walled sealed spacecraft structures produces sustained broadband acoustic-emission (AE) signals from which reliable first-arrival picking is difficult. This study presents an interpretable two-stage workflow that decouples leak screening from regional localization. Experiments used a 500 × 500 × 2.5 mm 3A21 aluminum-alloy plate with eight piezoelectric AE sensors under 0.1 MPa pressure difference. Intact, circular-hole, and slit-leak conditions were each tested three times with a 0.5–1.5 s steady-state window. Leak screening employed the 20–200 kHz mean spectral amplitude (Hann window). A provisional threshold of 0.85, set from three intact records, separated all leak records from intact controls. Regional localization used relative logarithmic RMS amplitudes in an energy-decay plus maximum-likelihood-estimation (ED+MLE) cost function on a 10 mm grid. The equivalent attenuation coefficient, empirically selected as 2.3 m−1 using the 1 mm central-hole calibration case, gave a 10 mm grid error for that calibration demonstration. With this coefficient fixed, the four transfer conditions yielded mean localization errors of 19.6–45.7 mm. The results provide preliminary feasibility evidence for leak detection and regional localization under the controlled laboratory conditions investigated in this study. Further validation requires independent channel calibration, larger background datasets, leak-rate measurements, parameter-sensitivity analysis, and testing on more representative structures.
Open AccessInterpretable Acoustic-Emission Leak Detection and ED+MLE-Based Regional Localization in Thin Aluminum-Alloy Plates Under Vacuum Pressure-Difference Excitation
Continuous gas leakage in thin-walled sealed spacecraft structures produces sustained broadband acoustic-emission (AE) signals from which reliable first-arrival picking is difficult. This study presents an interpretable two-stage workflow that decouples leak screening from regional localization. Experiments used a 500 × 500 × 2.5 mm 3A21 aluminum-alloy plate with eight piezoelectric AE sensors under 0.1 MPa pressure difference. Intact, circular-hole, and slit-leak conditions were each tested three times with a 0.5–1.5 s steady-state window. Leak screening employed the 20–200 kHz mean spectral amplitude (Hann window). A provisional threshold of 0.85, set from three intact records, separated all leak records from intact controls. Regional localization used relative logarithmic RMS amplitudes in an energy-decay plus maximum-likelihood-estimation (ED+MLE) cost function on a 10 mm grid. The equivalent attenuation coefficient, empirically selected as 2.3 m−1 using the 1 mm central-hole calibration case, gave a 10 mm grid error for that calibration demonstration. With this coefficient fixed, the four transfer conditions yielded mean localization errors of 19.6–45.7 mm. The results provide preliminary feasibility evidence for leak detection and regional localization under the controlled laboratory conditions investigated in this study. Further validation requires independent channel calibration, larger background datasets, leak-rate measurements, parameter-sensitivity analysis, and testing on more representative structures.
- Open Access
- 12 June 2026
- Published by Elsevier in SSRN Electronic Journal
Physics-Consistent Synthetic MWIR Imaging of UAVs Using Coupled CFD–CHT, Radiometric Projection, and Detector-Domain Rendering
Synthetic infrared imagery is useful for electro-optical evaluation and data generation only when the rendered thermal signatures remain physically traceable. This study develops a physics-consistent forward-modeling framework for synthetic mid-wave infrared (MWIR) imaging of unmanned aerial vehicles. The framework links steady computational fluid dynamics-conjugate heat transfer (CFD-CHT), atmospheric radiative transfer, geometric projection, visibility handling, and detector-domain degradation to convert a three-dimensional UAV thermal state into a sensor-parameterized digital-number image.A full-scale MQ-9-class UAV is modeled under steady cruise. The surface temperature field is obtained using CFD-CHT with temperature-dependent air properties, solar radiative loading, and an equivalent internal nacelle heat source. The resulting non-uniform temperature field is converted into sensor-received MWIR radiance by accounting for gray-body emission, reflected environmental radiance, atmospheric attenuation, and path radiance. Pinhole projection, back-face culling, and depth-buffering are used for focal-plane mapping, followed by optical blur, detector non-uniformity, stochastic noise, defective pixels, and 8-bit quantization. Detector parameters are constrained by controlled infrared measurements of a high-emissivity target, dark frames, and a knife-edge target.Sensitivity analyses show that constant-property modeling overpredicts the peak skin temperature by about 8 K, while solar irradiation produces local increases of up to 9 K. The generated MWIR images retain nacelle hotspots and leading-edge thermal enhancement across viewing aspects, demonstrating an experimentally constrained and physically interpretable route for synthetic UAV infrared imaging.
- 12 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessPhysics-Consistent Synthetic MWIR Imaging of UAVs Using Coupled CFD–CHT, Radiometric Projection, and Detector-Domain Rendering
Synthetic infrared imagery is useful for electro-optical evaluation and data generation only when the rendered thermal signatures remain physically traceable. This study develops a physics-consistent forward-modeling framework for synthetic mid-wave infrared (MWIR) imaging of unmanned aerial vehicles. The framework links steady computational fluid dynamics-conjugate heat transfer (CFD-CHT), atmospheric radiative transfer, geometric projection, visibility handling, and detector-domain degradation to convert a three-dimensional UAV thermal state into a sensor-parameterized digital-number image.A full-scale MQ-9-class UAV is modeled under steady cruise. The surface temperature field is obtained using CFD-CHT with temperature-dependent air properties, solar radiative loading, and an equivalent internal nacelle heat source. The resulting non-uniform temperature field is converted into sensor-received MWIR radiance by accounting for gray-body emission, reflected environmental radiance, atmospheric attenuation, and path radiance. Pinhole projection, back-face culling, and depth-buffering are used for focal-plane mapping, followed by optical blur, detector non-uniformity, stochastic noise, defective pixels, and 8-bit quantization. Detector parameters are constrained by controlled infrared measurements of a high-emissivity target, dark frames, and a knife-edge target.Sensitivity analyses show that constant-property modeling overpredicts the peak skin temperature by about 8 K, while solar irradiation produces local increases of up to 9 K. The generated MWIR images retain nacelle hotspots and leading-edge thermal enhancement across viewing aspects, demonstrating an experimentally constrained and physically interpretable route for synthetic UAV infrared imaging.
- Open Access
- 1 January 2026
- Published by Hainan University in Natural Science of Hainan University
- Vol. 45
Kinematics analysis and simulation of an underwater manipulator for propeller entanglement relief
针对舰船螺旋桨易被渔网等异物绞缠,且人工清理存在较风险高的问题,本研究以一种多自由度水下清绞机械手为研究对象,运用Modified-DH法构建运动学模型,并完成正逆运动学求解。采用蒙特卡洛法对其可达工作空间进行仿真分析,基于多项式插值开展轨迹规划,并借助Matlab实现轨迹仿真,同时结合Adams完成虚拟样机运动验证。结果表明:该机械手具备充足的工作空间,能够覆盖螺旋桨清绞作业区域。采用五次多项式插值规划的轨迹呈现出平滑连续的特征,关节运动无冲击、无突变,运行平稳性良好。研究结果可为水下清绞机械手的结构优化与控制策略设计提供理论支撑。
- 1 January 2026
- Published by Hainan University in Natural Science of Hainan University
- Vol. 45
Open AccessKinematics analysis and simulation of an underwater manipulator for propeller entanglement relief
针对舰船螺旋桨易被渔网等异物绞缠,且人工清理存在较风险高的问题,本研究以一种多自由度水下清绞机械手为研究对象,运用Modified-DH法构建运动学模型,并完成正逆运动学求解。采用蒙特卡洛法对其可达工作空间进行仿真分析,基于多项式插值开展轨迹规划,并借助Matlab实现轨迹仿真,同时结合Adams完成虚拟样机运动验证。结果表明:该机械手具备充足的工作空间,能够覆盖螺旋桨清绞作业区域。采用五次多项式插值规划的轨迹呈现出平滑连续的特征,关节运动无冲击、无突变,运行平稳性良好。研究结果可为水下清绞机械手的结构优化与控制策略设计提供理论支撑。
- Open Access
Multi-Objective Optimization of Torque Motor Structural Parameters in Direct-Drive Valves Based on Genetic Algorithm
This paper presents a genetic algorithm (GA) approach to optimize key structural parameters of the torque motor used in a direct-drive slide knife gate valve. The optimization aims at enhancing the performance of the torque motor by improving the output torque, minimizing the overshoot, and reducing the response time. A mathematical model based on these performance indicators is formulated to guide the optimization process. Compared to the original design, the optimized design is shown to achieve a 26.4% increase in output torque, a 0.14 ms reduction in response time, and a 9% decrease in overshoot. Additionally, AMESim simulations confirm that the optimized motor significantly improves valve control accuracy, dynamic response, and flow stability, while also decreasing sensitivity to pressure fluctuations under high-current conditions. Finally, experimental results are provided to corroborate the simulation findings, validating the accuracy and effectiveness of the proposed optimization methodology. This study provides novel theoretical insights and practical guidance for the design of high-performance torque motors used in direct-drive electro-hydraulic servo valves within aerospace applications.
Open AccessMulti-Objective Optimization of Torque Motor Structural Parameters in Direct-Drive Valves Based on Genetic Algorithm
This paper presents a genetic algorithm (GA) approach to optimize key structural parameters of the torque motor used in a direct-drive slide knife gate valve. The optimization aims at enhancing the performance of the torque motor by improving the output torque, minimizing the overshoot, and reducing the response time. A mathematical model based on these performance indicators is formulated to guide the optimization process. Compared to the original design, the optimized design is shown to achieve a 26.4% increase in output torque, a 0.14 ms reduction in response time, and a 9% decrease in overshoot. Additionally, AMESim simulations confirm that the optimized motor significantly improves valve control accuracy, dynamic response, and flow stability, while also decreasing sensitivity to pressure fluctuations under high-current conditions. Finally, experimental results are provided to corroborate the simulation findings, validating the accuracy and effectiveness of the proposed optimization methodology. This study provides novel theoretical insights and practical guidance for the design of high-performance torque motors used in direct-drive electro-hydraulic servo valves within aerospace applications.
- 1 July 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (7)
A stick–slip piezoelectric actuator utilizing a special parallelogram flexible mechanism
A stick–slip actuator based on a parallelogram flexible mechanism is proposed to achieve high-performance output. This actuator utilizes the coupled motion generated when the parallelogram is driven by the piezo-stack to propel the slider. To minimize the shear force on the piezo-stack during operation, straight circular flexible hinge structure is added to the output end of the piezo-stack. In addition, a straight beam flexible hinges structure is incorporated into the parallelogram flexible mechanism to achieve a high output speed under conditions of low driving frequency. Static analysis, finite element simulation, optimized design, and experimental studies of the flexible mechanism were conducted. The finite element analysis indicates that the flexible mechanism, based on a parallelogram flexible mechanism, can generate motion in both the X and Y directions, reduce the shear force on the piezo-stack, and increase the output speed of the actuator, among other functions. A prototype of the stick–slip piezoelectric actuator was fabricated, and a measurement system was developed and experimentally validated against the results of the theoretical analysis and finite element simulation. The experimental results demonstrate that the actuator achieves a maximum output speed of 17.64 mm/s, a resolution of 62 nm, a maximum load capacity of 310 g, and excellent repetitive positioning accuracy, with the structural dimensions of the stator measuring only 43 × 44 × 10 mm3.
- 1 July 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (7)
A stick–slip piezoelectric actuator utilizing a special parallelogram flexible mechanism
A stick–slip actuator based on a parallelogram flexible mechanism is proposed to achieve high-performance output. This actuator utilizes the coupled motion generated when the parallelogram is driven by the piezo-stack to propel the slider. To minimize the shear force on the piezo-stack during operation, straight circular flexible hinge structure is added to the output end of the piezo-stack. In addition, a straight beam flexible hinges structure is incorporated into the parallelogram flexible mechanism to achieve a high output speed under conditions of low driving frequency. Static analysis, finite element simulation, optimized design, and experimental studies of the flexible mechanism were conducted. The finite element analysis indicates that the flexible mechanism, based on a parallelogram flexible mechanism, can generate motion in both the X and Y directions, reduce the shear force on the piezo-stack, and increase the output speed of the actuator, among other functions. A prototype of the stick–slip piezoelectric actuator was fabricated, and a measurement system was developed and experimentally validated against the results of the theoretical analysis and finite element simulation. The experimental results demonstrate that the actuator achieves a maximum output speed of 17.64 mm/s, a resolution of 62 nm, a maximum load capacity of 310 g, and excellent repetitive positioning accuracy, with the structural dimensions of the stator measuring only 43 × 44 × 10 mm3.
- Open Access
- 12 January 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (1) , 130
Development of a Microheater with a Large Heating Area and Low Thermal Stress in the Heating Area
In this paper, a microheater that can absorb thermal stress and has a large heating area is demonstrated by optimizing the structure and process of the microheater. Four symmetrically distributed elongated support beam structures were machined around the microheater via deep silicon etching. This design efficiently mitigates the deformation of the heated region caused by thermal expansion and enhances the structural stability of the microheater. The updated microheater no longer converts the work area into a thin film; instead, it creates a stable heating platform that can uniformly heat a work area measuring 10 × 10 mm2. The microheater is verified to have high temperature uniformity and structural stability in finite element simulation. Finally, thorough investigations of electrical–thermal–structural characterization were conducted. The test findings show that the new microheater can achieve 350 °C with a power consumption of 6 W and a thermal reaction time of 22 s. A scan of its whole plane reveals that the surface of the working area of the new microheater is flat and does not distort in response to variations in temperature, offering good structural stability.
- 12 January 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (1) , 130
Open AccessDevelopment of a Microheater with a Large Heating Area and Low Thermal Stress in the Heating Area
In this paper, a microheater that can absorb thermal stress and has a large heating area is demonstrated by optimizing the structure and process of the microheater. Four symmetrically distributed elongated support beam structures were machined around the microheater via deep silicon etching. This design efficiently mitigates the deformation of the heated region caused by thermal expansion and enhances the structural stability of the microheater. The updated microheater no longer converts the work area into a thin film; instead, it creates a stable heating platform that can uniformly heat a work area measuring 10 × 10 mm2. The microheater is verified to have high temperature uniformity and structural stability in finite element simulation. Finally, thorough investigations of electrical–thermal–structural characterization were conducted. The test findings show that the new microheater can achieve 350 °C with a power consumption of 6 W and a thermal reaction time of 22 s. A scan of its whole plane reveals that the surface of the working area of the new microheater is flat and does not distort in response to variations in temperature, offering good structural stability.
- Open Access
A Study on Refraction Error Compensation Method for Underwater Spinning Laser Scanning Three-Dimensional Imaging
Laser scanning 3D imaging technology, because it can obtain accurate three-dimensional surface data, has been widely used in the search for wrecks and rescue operations, underwater resource development, and other fields. At present, the conventional underwater spinning laser scanning imaging system maintains a relatively fixed light window. However, in low-light situations underwater, the rotation of the scanning device causes some degree of water fluctuation, which warps the light strip data that the system sensor receives about the object’s surface. To solve this problem, this research studies an underwater 3D scanning and imaging system that makes use of a fixed light window and a spinning laser (FWLS). A refraction error compensation algorithm is investigated that is based on the fundamentals of linear laser scanning imaging, and a dynamic refraction mathematical model is established based on the motion of the imaging device. The results of the experiment on error analysis in an optimal underwater environment indicate that the error in reconstructing the radius is decreased by 60% (from 2.5 mm to around 1 mm) when compensating for the measurement data of a standard sphere with a radius of 20 mm. Moreover, the compensated point cloud data exhibit a higher degree of correspondence with the model of the standard spherical point cloud. Furthermore, we examine the impact of physical noise, measurement distance, and partial occlusion of the object on the imaging system inside an authentic underwater setting. This study is a good starting point for looking at the refractive error of an underwater laser scanning imaging system. It also provides to us some ideas for future research on the refractive error of other scanning imaging methods.
Open AccessA Study on Refraction Error Compensation Method for Underwater Spinning Laser Scanning Three-Dimensional Imaging
Laser scanning 3D imaging technology, because it can obtain accurate three-dimensional surface data, has been widely used in the search for wrecks and rescue operations, underwater resource development, and other fields. At present, the conventional underwater spinning laser scanning imaging system maintains a relatively fixed light window. However, in low-light situations underwater, the rotation of the scanning device causes some degree of water fluctuation, which warps the light strip data that the system sensor receives about the object’s surface. To solve this problem, this research studies an underwater 3D scanning and imaging system that makes use of a fixed light window and a spinning laser (FWLS). A refraction error compensation algorithm is investigated that is based on the fundamentals of linear laser scanning imaging, and a dynamic refraction mathematical model is established based on the motion of the imaging device. The results of the experiment on error analysis in an optimal underwater environment indicate that the error in reconstructing the radius is decreased by 60% (from 2.5 mm to around 1 mm) when compensating for the measurement data of a standard sphere with a radius of 20 mm. Moreover, the compensated point cloud data exhibit a higher degree of correspondence with the model of the standard spherical point cloud. Furthermore, we examine the impact of physical noise, measurement distance, and partial occlusion of the object on the imaging system inside an authentic underwater setting. This study is a good starting point for looking at the refractive error of an underwater laser scanning imaging system. It also provides to us some ideas for future research on the refractive error of other scanning imaging methods.
- Open Access
- 13 November 2023
- Published by MDPI AG in Preprints.org
A Study on Refraction Error Compensation Method for Underwater Spinning Laser Scanning 3D Imaging
Laser scanning 3D imaging technology, because it can get accurate three-dimensional surface data, has been widely used in the search for wrecks and rescue operations, underwater resource development, and other fields. At present, the conventional underwater rotating laser scanning imaging system maintains a relatively fixed light window. However, in low-light situations underwater, the rotation of the scanning device causes some degree of water fluctuation, which warps the light strip data that the system sensor receives about the object's surface. To solve the problem, this research studies an underwater 3D scanning and imaging system that makes use of a fixed-light window and a spinning laser (FWLS). A refraction error compensation algorithm is investigated that is based on the fundamentals of linear laser scanning imaging and the dynamic refraction mathematical model is established by the motion of the imaging device. During the imaging process, the incident angle between the laser and the light window varies due to the scanning mode of the system. The experimental results show that the reconstruction radius error is reduced by 60% (from 2.5 mm to about 1 mm) when the measurement data for a standard sphere with a radius of 20 mm are compensated. Moreover, the compensated point cloud data exhibits a higher degree of correspondence with the model of the standard spherical point cloud. This study has a specific reference value for the refractive error analysis of an underwater laser scanning imaging system, and it provides certain research ideas for the subsequent refractive error analysis of various scanning imaging modalities.
- 13 November 2023
- Published by MDPI AG in Preprints.org
Open AccessA Study on Refraction Error Compensation Method for Underwater Spinning Laser Scanning 3D Imaging
Laser scanning 3D imaging technology, because it can get accurate three-dimensional surface data, has been widely used in the search for wrecks and rescue operations, underwater resource development, and other fields. At present, the conventional underwater rotating laser scanning imaging system maintains a relatively fixed light window. However, in low-light situations underwater, the rotation of the scanning device causes some degree of water fluctuation, which warps the light strip data that the system sensor receives about the object's surface. To solve the problem, this research studies an underwater 3D scanning and imaging system that makes use of a fixed-light window and a spinning laser (FWLS). A refraction error compensation algorithm is investigated that is based on the fundamentals of linear laser scanning imaging and the dynamic refraction mathematical model is established by the motion of the imaging device. During the imaging process, the incident angle between the laser and the light window varies due to the scanning mode of the system. The experimental results show that the reconstruction radius error is reduced by 60% (from 2.5 mm to about 1 mm) when the measurement data for a standard sphere with a radius of 20 mm are compensated. Moreover, the compensated point cloud data exhibits a higher degree of correspondence with the model of the standard spherical point cloud. This study has a specific reference value for the refractive error analysis of an underwater laser scanning imaging system, and it provides certain research ideas for the subsequent refractive error analysis of various scanning imaging modalities.
- Open Access
Cavitation Observation and Noise Characteristics in Rectangular Throttling Groove Spool
A hydraulic cavitation platform was developed in order to examine the occurrence of cavitation in the rectangular throttling groove spool and its correlation with noise characteristics. The test valve is constructed using PMMA material, which possesses excellent transparency. This transparency enables direct visual examination of cavitation occurring at the throttle slot. Additionally, high-speed photography is employed to observe the flow characteristics of the valve port, facilitating the analysis of cavitation morphology changes. Furthermore, a noise meter is utilized to measure and record the noise level and its corresponding spectrum. The flow field and flow phenomena at the rectangular throttling groove spool were studied using high-speed photography, noise spectrum analysis, and other methods. It is discovered that back pressure has the greatest influence on cavitation and flow separation, followed by the influence of intake pressure on cavitation morphology and noise. As the back pressure lowers, the cavitation morphology changes from flaky to cloudy, and the cavitation intensity, distribution area, and noise level increase. Background noise and cavitation noise have distinct frequency differences; cavitation noise in the rectangular throttling groove spool is high-frequency noise, with a frequency of more than 8 kHz, and the higher the frequency, the greater the difference in noise value. The magnitude of the alterations in noise intensity is minimal. The noise values exhibit slight variations of 2.3 dB, 4 dB, and 4.3 dB under varying back pressure circumstances of 3 MPa, 4 MPa, and 5 MPa inlet pressure, respectively. It is recommended to use the frequency of cavitation noise to detect the cavitation state and monitor the cavitation process. In the low-frequency region, the cavitation noise in the rectangular throttle groove valve core is not significantly different. Once the center frequency surpasses 3.15 kHz, a discernible distinction emerges, with the magnitude of the discrepancy in noise value increasing as the frequency rises. In other words, the cavitation cloud does not pulsate at one single frequency, but rather in a range of relatively high frequencies (more than 3.15 kHz).
Open AccessCavitation Observation and Noise Characteristics in Rectangular Throttling Groove Spool
A hydraulic cavitation platform was developed in order to examine the occurrence of cavitation in the rectangular throttling groove spool and its correlation with noise characteristics. The test valve is constructed using PMMA material, which possesses excellent transparency. This transparency enables direct visual examination of cavitation occurring at the throttle slot. Additionally, high-speed photography is employed to observe the flow characteristics of the valve port, facilitating the analysis of cavitation morphology changes. Furthermore, a noise meter is utilized to measure and record the noise level and its corresponding spectrum. The flow field and flow phenomena at the rectangular throttling groove spool were studied using high-speed photography, noise spectrum analysis, and other methods. It is discovered that back pressure has the greatest influence on cavitation and flow separation, followed by the influence of intake pressure on cavitation morphology and noise. As the back pressure lowers, the cavitation morphology changes from flaky to cloudy, and the cavitation intensity, distribution area, and noise level increase. Background noise and cavitation noise have distinct frequency differences; cavitation noise in the rectangular throttling groove spool is high-frequency noise, with a frequency of more than 8 kHz, and the higher the frequency, the greater the difference in noise value. The magnitude of the alterations in noise intensity is minimal. The noise values exhibit slight variations of 2.3 dB, 4 dB, and 4.3 dB under varying back pressure circumstances of 3 MPa, 4 MPa, and 5 MPa inlet pressure, respectively. It is recommended to use the frequency of cavitation noise to detect the cavitation state and monitor the cavitation process. In the low-frequency region, the cavitation noise in the rectangular throttle groove valve core is not significantly different. Once the center frequency surpasses 3.15 kHz, a discernible distinction emerges, with the magnitude of the discrepancy in noise value increasing as the frequency rises. In other words, the cavitation cloud does not pulsate at one single frequency, but rather in a range of relatively high frequencies (more than 3.15 kHz).