Amir Ismailzadeh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Amir Ismailzadeh has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Abouzar Mehraban
Institute of Remote Sensing, Nanjing University of Information Science & Technology (NUIST), Nanjing, China
1 shared publication- Alireza Shams
Department of Chemistry, Ma. C., Islamic Azad University, Mashhad, Iran
1 shared publication - Hamid Fadaei
Research Centre for Conservation of Cultural Relics, Research Institute of Cultural Heritage and Tourism, Tehran, Iran
1 shared publication - Mahboubeh Masrournia
Islamic Azad University
1 shared publication - Mahdi Ghorbani
Department of Chemistry, Faculty of Sciences, Ferdowsi University of Mashhad, Mashhad, Iran
1 shared publication - Majid Keshavarzi
Cellular and Molecular Research Center, Sabzevar University of Medical Sciences, Faculty of Health, Sabzevar, Iran
1 shared publication
Latest Publications
- Open Access
- 1 June 2025
- Published by InkVista Publishing House
- Vol. 11 (1) , 1-16
A Review of Identification, Measurement, and Classification Methods for Environmental Pollutants Affecting the Erosion of Stone Heritage
With the expansion of industries and the emergence of new technologies, the amount and diversity of environmental pollutants have increased significantly. Consequently, the erosion of historical artifacts near pollution sources has become more complex, and their deterioration—particularly in open spaces—is expected to intensify in the future. Given the importance of ...
- 1 June 2025
- Published by InkVista Publishing House
- Vol. 11 (1) , 1-16
Open AccessA Review of Identification, Measurement, and Classification Methods for Environmental Pollutants Affecting the Erosion of Stone Heritage
With the expansion of industries and the emergence of new technologies, the amount and diversity of environmental pollutants have increased significantly. Consequently, the erosion of historical artifacts near pollution sources has become more complex, and their deterioration—particularly in open spaces—is expected to intensify in the future. Given the importance of ...
- 29 July 2023
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 415 (23) , 5681-5694
Optimization and synthesis of a novel sorbent composite based on magnetic chitosan-amine-functionalized bimetallic MOF for the simultaneous dispersive solid-phase microextraction of four aflatoxins in real water, herbal distillate, and food samples
Aflatoxins (AFs), an important category of pollutants, are formed in many foods and adversely affect human health. Therefore, their determination is critical to ensuring human food health. An efficient dispersive solid-phase microextraction technique was developed as a simple and straightforward sample preparation technique for determination of four aflatoxins using a high-performance liquid chromatography (HPLC) fluorescence detector. A novel efficient, green sorbent for extracting AFs was synthesized based on hydrothermal and chemical strategies. The amounts of three sorbent components were optimized using a mixture design (simplex lattice design), including 14 experiments. The optimal amount of amino-bimetallic Fe/Ni-MIL-53 nanospheres, chitosan, and magnetic Fe3O4 nanoparticles as sorbent components was 0.87, 0.67, and 0.47 g, respectively. Also, various factors affecting the process of AF determination were studied and optimized in two successive experimental designs, including the definitive screening design and the Box–Behnken design. Under optimal conditions, the linear ranges for measuring aflatoxin B1, aflatoxin B2, aflatoxin G1, and aflatoxin G2 were 0.05–82.6, 0.07–86.4, 0.08–85.7, and 0.07–89.5 ng mL−1, respectively. The relative standard deviations under inter-day and intra-day conditions for measuring AFs at three analyte concentrations were determined in triplicate analysis and were in the ranges of 3.7–4.6% and 4.9–6.1% for water sample analysis, respectively. The qualitative detection limits for determining AFs were between 0.01 and 0.05 ng mL−1. The pre-concentration factor of the method for measuring AFs ranged from 739.7 to 802.1. The proposed method was used for determining AFs in several real samples, including herbal distillate, black tea, corn, and real water samples. The relative recovery and standard deviation were 87.8–97.8% and 4.10–6.82%, respectively. Graphical abstract
- 29 July 2023
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 415 (23) , 5681-5694
Optimization and synthesis of a novel sorbent composite based on magnetic chitosan-amine-functionalized bimetallic MOF for the simultaneous dispersive solid-phase microextraction of four aflatoxins in real water, herbal distillate, and food samples
Aflatoxins (AFs), an important category of pollutants, are formed in many foods and adversely affect human health. Therefore, their determination is critical to ensuring human food health. An efficient dispersive solid-phase microextraction technique was developed as a simple and straightforward sample preparation technique for determination of four aflatoxins using a high-performance liquid chromatography (HPLC) fluorescence detector. A novel efficient, green sorbent for extracting AFs was synthesized based on hydrothermal and chemical strategies. The amounts of three sorbent components were optimized using a mixture design (simplex lattice design), including 14 experiments. The optimal amount of amino-bimetallic Fe/Ni-MIL-53 nanospheres, chitosan, and magnetic Fe3O4 nanoparticles as sorbent components was 0.87, 0.67, and 0.47 g, respectively. Also, various factors affecting the process of AF determination were studied and optimized in two successive experimental designs, including the definitive screening design and the Box–Behnken design. Under optimal conditions, the linear ranges for measuring aflatoxin B1, aflatoxin B2, aflatoxin G1, and aflatoxin G2 were 0.05–82.6, 0.07–86.4, 0.08–85.7, and 0.07–89.5 ng mL−1, respectively. The relative standard deviations under inter-day and intra-day conditions for measuring AFs at three analyte concentrations were determined in triplicate analysis and were in the ranges of 3.7–4.6% and 4.9–6.1% for water sample analysis, respectively. The qualitative detection limits for determining AFs were between 0.01 and 0.05 ng mL−1. The pre-concentration factor of the method for measuring AFs ranged from 739.7 to 802.1. The proposed method was used for determining AFs in several real samples, including herbal distillate, black tea, corn, and real water samples. The relative recovery and standard deviation were 87.8–97.8% and 4.10–6.82%, respectively. Graphical abstract
- 13 March 2020
- Published by Springer Nature in Chemical Papers
- Vol. 74 (9) , 2929-2943
An environmentally friendly sample pre-treatment method based on magnetic ionic liquids for trace determination of nitrotoluene compounds in soil and water samples by gas chromatography–mass spectrometry using response surface methodology
- 13 March 2020
- Published by Springer Nature in Chemical Papers
- Vol. 74 (9) , 2929-2943
An environmentally friendly sample pre-treatment method based on magnetic ionic liquids for trace determination of nitrotoluene compounds in soil and water samples by gas chromatography–mass spectrometry using response surface methodology