Alireza Shams
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Alireza Shams has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Mahboubeh Masrournia
Islamic Azad University
2 shared publications - Mahdi Ghorbani
Department of Chemistry, Faculty of Sciences, Ferdowsi University of Mashhad, Mashhad, Iran
2 shared publications - Narges Ashraf
Department of Chemistry, Faculty of Science, Ferdowsi University of Mashhad, Mashhad, Iran
2 shared publications Abouzar Mehraban
Institute of Remote Sensing, Nanjing University of Information Science & Technology (NUIST), Nanjing, China
1 shared publication- Amir Ismailzadeh
Department of Chemistry, Mashhad Branch, Islamic Azad University, Mashhad, Iran
1 shared publication - Foroughalzaman Kazempoor Mofrad
Department of Chemistry, Ma. C., Islamic Azad University, Mashhad, Iran
1 shared publication
Latest Publications
- Open Access
- 26 May 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 16 (26) , 23528-23543
Ultra-sensitive determination of carcinogenic aflatoxins in food matrices using a novel magnetic bimetallic ZIF-8@chitosan sorbent and dispersive micro-solid phase extraction
A dispersive micro-solid phase extraction (D-µ-SPE) method coupled with HPLC-FLD was developed for the sensitive determination of carcinogenic aflatoxins. A novel magnetic composite sorbent was synthesized by integrating bimetallic Co/Zn ZIF-8, chitosan, and Fe3O4 nanoparticles. Statistical comparison revealed that bimetallic Co/Zn ZIF-8 exhibited significantly enhanced aflatoxin extraction efficiency over its monometallic counterpart, with subsequent functionalization using chitosan and magnetization further improving performance. Key extraction parameters were systematically optimized using experimental design. The validated method demonstrated wide linearity (0.02–120 ng mL−1; R2 > 0.993), and low detection limits (LODs: 0.006–0.07 ng mL−1), and quantification limits (LOQs: 0.02–0.21 ng mL−1). Precision ranged from 3.7–4.7% (intra-day) to 4.5–6.2% (inter-day). Given the critical need to monitor these potent toxins in high-consumption and high-risk commodities, the method was successfully applied to commercial mineral water (potential environmental contamination), rice (global dietary staple), and peanut (notoriously susceptible crop) samples. Relative recoveries of 91.2–98.0% (RSD < 4.4%) confirmed the method's robustness and accuracy for complex matrices.
- 26 May 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 16 (26) , 23528-23543
Open AccessUltra-sensitive determination of carcinogenic aflatoxins in food matrices using a novel magnetic bimetallic ZIF-8@chitosan sorbent and dispersive micro-solid phase extraction
A dispersive micro-solid phase extraction (D-µ-SPE) method coupled with HPLC-FLD was developed for the sensitive determination of carcinogenic aflatoxins. A novel magnetic composite sorbent was synthesized by integrating bimetallic Co/Zn ZIF-8, chitosan, and Fe3O4 nanoparticles. Statistical comparison revealed that bimetallic Co/Zn ZIF-8 exhibited significantly enhanced aflatoxin extraction efficiency over its monometallic counterpart, with subsequent functionalization using chitosan and magnetization further improving performance. Key extraction parameters were systematically optimized using experimental design. The validated method demonstrated wide linearity (0.02–120 ng mL−1; R2 > 0.993), and low detection limits (LODs: 0.006–0.07 ng mL−1), and quantification limits (LOQs: 0.02–0.21 ng mL−1). Precision ranged from 3.7–4.7% (intra-day) to 4.5–6.2% (inter-day). Given the critical need to monitor these potent toxins in high-consumption and high-risk commodities, the method was successfully applied to commercial mineral water (potential environmental contamination), rice (global dietary staple), and peanut (notoriously susceptible crop) samples. Relative recoveries of 91.2–98.0% (RSD < 4.4%) confirmed the method's robustness and accuracy for complex matrices.
- 29 July 2023
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 415 (23) , 5681-5694
Optimization and synthesis of a novel sorbent composite based on magnetic chitosan-amine-functionalized bimetallic MOF for the simultaneous dispersive solid-phase microextraction of four aflatoxins in real water, herbal distillate, and food samples
Aflatoxins (AFs), an important category of pollutants, are formed in many foods and adversely affect human health. Therefore, their determination is critical to ensuring human food health. An efficient dispersive solid-phase microextraction technique was developed as a simple and straightforward sample preparation technique for determination of four aflatoxins using a high-performance liquid chromatography (HPLC) fluorescence detector. A novel efficient, green sorbent for extracting AFs was synthesized based on hydrothermal and chemical strategies. The amounts of three sorbent components were optimized using a mixture design (simplex lattice design), including 14 experiments. The optimal amount of amino-bimetallic Fe/Ni-MIL-53 nanospheres, chitosan, and magnetic Fe3O4 nanoparticles as sorbent components was 0.87, 0.67, and 0.47 g, respectively. Also, various factors affecting the process of AF determination were studied and optimized in two successive experimental designs, including the definitive screening design and the Box–Behnken design. Under optimal conditions, the linear ranges for measuring aflatoxin B1, aflatoxin B2, aflatoxin G1, and aflatoxin G2 were 0.05–82.6, 0.07–86.4, 0.08–85.7, and 0.07–89.5 ng mL−1, respectively. The relative standard deviations under inter-day and intra-day conditions for measuring AFs at three analyte concentrations were determined in triplicate analysis and were in the ranges of 3.7–4.6% and 4.9–6.1% for water sample analysis, respectively. The qualitative detection limits for determining AFs were between 0.01 and 0.05 ng mL−1. The pre-concentration factor of the method for measuring AFs ranged from 739.7 to 802.1. The proposed method was used for determining AFs in several real samples, including herbal distillate, black tea, corn, and real water samples. The relative recovery and standard deviation were 87.8–97.8% and 4.10–6.82%, respectively. Graphical abstract
- 29 July 2023
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 415 (23) , 5681-5694
Optimization and synthesis of a novel sorbent composite based on magnetic chitosan-amine-functionalized bimetallic MOF for the simultaneous dispersive solid-phase microextraction of four aflatoxins in real water, herbal distillate, and food samples
Aflatoxins (AFs), an important category of pollutants, are formed in many foods and adversely affect human health. Therefore, their determination is critical to ensuring human food health. An efficient dispersive solid-phase microextraction technique was developed as a simple and straightforward sample preparation technique for determination of four aflatoxins using a high-performance liquid chromatography (HPLC) fluorescence detector. A novel efficient, green sorbent for extracting AFs was synthesized based on hydrothermal and chemical strategies. The amounts of three sorbent components were optimized using a mixture design (simplex lattice design), including 14 experiments. The optimal amount of amino-bimetallic Fe/Ni-MIL-53 nanospheres, chitosan, and magnetic Fe3O4 nanoparticles as sorbent components was 0.87, 0.67, and 0.47 g, respectively. Also, various factors affecting the process of AF determination were studied and optimized in two successive experimental designs, including the definitive screening design and the Box–Behnken design. Under optimal conditions, the linear ranges for measuring aflatoxin B1, aflatoxin B2, aflatoxin G1, and aflatoxin G2 were 0.05–82.6, 0.07–86.4, 0.08–85.7, and 0.07–89.5 ng mL−1, respectively. The relative standard deviations under inter-day and intra-day conditions for measuring AFs at three analyte concentrations were determined in triplicate analysis and were in the ranges of 3.7–4.6% and 4.9–6.1% for water sample analysis, respectively. The qualitative detection limits for determining AFs were between 0.01 and 0.05 ng mL−1. The pre-concentration factor of the method for measuring AFs ranged from 739.7 to 802.1. The proposed method was used for determining AFs in several real samples, including herbal distillate, black tea, corn, and real water samples. The relative recovery and standard deviation were 87.8–97.8% and 4.10–6.82%, respectively. Graphical abstract
- 20 February 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (5) , 963-971
Electrochemical generation of palladium volatile species enhanced with Sn( ii ): application for detection of Pd( ii ) by pyrolytic graphite-coated furnace atomic absorption spectrometry
Herein, a novel sample derivatization and introduction system, based on electrochemical generation of palladium volatile species (PdVS), has been developed for determination of Pd concentration via pyrolytic graphite-coated furnace atomic absorption spectrometry. PdVS were produced in the cathode chamber of a home-made electrochemical vapor generation cell in which a tungsten-inert gas (TIG) welding electrode and Sn(II) served as the cathode and the enhancement reagent, respectively. The produced PdVS were transferred into a pyrolytic graphite-coated furnace by a stream of argon carrier gas where they were trapped and atomized. Plackett–Burman experimental design was used to screen the influential experimental parameters. The effect of significant influential parameters on the method sensitivity was evaluated and optimized. Under optimum operating conditions, the calibration curve for Pd was constructed and shown to be linear in the Pd concentration range of 7.5 to 110 ng L−1. Detection (3sb/m) and quantification (10sb/m) limits of the proposed method were evaluated using 10 blank samples and found to be 2.1 ng L−1 and 7.1 ng L−1, respectively. The relative standard deviation (n = 7, at 50 ng L−1 concentration level) was 5%. The accuracy of the proposed method was checked by analysing two different certified reference materials which yielded the recoveries of 105% and 81% for Pd.
- 20 February 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 34 (5) , 963-971
Electrochemical generation of palladium volatile species enhanced with Sn( ii ): application for detection of Pd( ii ) by pyrolytic graphite-coated furnace atomic absorption spectrometry
Herein, a novel sample derivatization and introduction system, based on electrochemical generation of palladium volatile species (PdVS), has been developed for determination of Pd concentration via pyrolytic graphite-coated furnace atomic absorption spectrometry. PdVS were produced in the cathode chamber of a home-made electrochemical vapor generation cell in which a tungsten-inert gas (TIG) welding electrode and Sn(II) served as the cathode and the enhancement reagent, respectively. The produced PdVS were transferred into a pyrolytic graphite-coated furnace by a stream of argon carrier gas where they were trapped and atomized. Plackett–Burman experimental design was used to screen the influential experimental parameters. The effect of significant influential parameters on the method sensitivity was evaluated and optimized. Under optimum operating conditions, the calibration curve for Pd was constructed and shown to be linear in the Pd concentration range of 7.5 to 110 ng L−1. Detection (3sb/m) and quantification (10sb/m) limits of the proposed method were evaluated using 10 blank samples and found to be 2.1 ng L−1 and 7.1 ng L−1, respectively. The relative standard deviation (n = 7, at 50 ng L−1 concentration level) was 5%. The accuracy of the proposed method was checked by analysing two different certified reference materials which yielded the recoveries of 105% and 81% for Pd.
- 8 August 2017
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 32 (11) , 2173-2181
Ultra-trace determination of thallium by electrochemical hydride generation using efficient tungsten electrodes followed by in situ trapping on a graphite tube and detection by electrothermal atomic absorption spectrometry
A novel and extremely efficient cathode material, namely, tungsten-inert gas welding electrode, along with Pd(II) as an enhancement reagent has been introduced for electrochemical hydride generation of thallium (Tl). In situ trapping of the volatile species on a graphite tube along with electrothermal atomic absorption spectrometry was used for preconcentration and detection of Tl in order to provide high sensitivity. The volatile species were transferred to the graphite tube by the flow of argon gas and trapped there for a time period of 170 s. To optimize the performance of the proposed analytical method, effects of several effective experimental parameters, such as the graphite tube modifier, argon gas flow rate, trapping temperature and period, atomization temperature, concentration of the catholyte, and also electrolysis duration were investigated and discussed. Under optimum operating conditions, the calibration curve was plotted which was linear in the concentration range of 28 to 300 ng L−1 of Tl. The limit of detection (LOD) and the limit of quantification (LOQ) of the method were obtained to be 8 ng L−1 and 28 ng L−1, based on 3sb/m and 10sb/m criteria, respectively. The relative standard deviation (RSD%) of the method was found to be 2% for seven replicate measurements at a concentration level of 150 ng L−1 of Tl. The effects of several potential chemical interferents were studied and discussed. The accuracy and the analytical applicability of the proposed method were checked through the analysis of commercial certified reference materials, namely, contaminated unalloyed zinc (ERM®-EB325) and also drinking water containing trace metals (CRM-TMDW). As this method was insensitive towards the oxidation state of Tl, it is suitable for the determination of the total Tl in real analytical samples.
- 8 August 2017
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 32 (11) , 2173-2181
Ultra-trace determination of thallium by electrochemical hydride generation using efficient tungsten electrodes followed by in situ trapping on a graphite tube and detection by electrothermal atomic absorption spectrometry
A novel and extremely efficient cathode material, namely, tungsten-inert gas welding electrode, along with Pd(II) as an enhancement reagent has been introduced for electrochemical hydride generation of thallium (Tl). In situ trapping of the volatile species on a graphite tube along with electrothermal atomic absorption spectrometry was used for preconcentration and detection of Tl in order to provide high sensitivity. The volatile species were transferred to the graphite tube by the flow of argon gas and trapped there for a time period of 170 s. To optimize the performance of the proposed analytical method, effects of several effective experimental parameters, such as the graphite tube modifier, argon gas flow rate, trapping temperature and period, atomization temperature, concentration of the catholyte, and also electrolysis duration were investigated and discussed. Under optimum operating conditions, the calibration curve was plotted which was linear in the concentration range of 28 to 300 ng L−1 of Tl. The limit of detection (LOD) and the limit of quantification (LOQ) of the method were obtained to be 8 ng L−1 and 28 ng L−1, based on 3sb/m and 10sb/m criteria, respectively. The relative standard deviation (RSD%) of the method was found to be 2% for seven replicate measurements at a concentration level of 150 ng L−1 of Tl. The effects of several potential chemical interferents were studied and discussed. The accuracy and the analytical applicability of the proposed method were checked through the analysis of commercial certified reference materials, namely, contaminated unalloyed zinc (ERM®-EB325) and also drinking water containing trace metals (CRM-TMDW). As this method was insensitive towards the oxidation state of Tl, it is suitable for the determination of the total Tl in real analytical samples.