Thierry Schild
Research Subjects
Thierry Schild has a total of 253 co-authors. Here are the top co-authors by number of shared publications:
- Nicolai Martovetsky
US ITER Project, Oak Ridge National Laboratory, Oak Ridge, TN, USA
12 shared publications - Neil Mitchell
ITER Organization, St. Paul Lez Durance, France
10 shared publications - John Smith
General Atomics, San Diego, CA, USA
9 shared publications - Min Liao
ITER Organization, St. Paul Lez Durance, France
8 shared publications - Yasuyuki Miyoshi
ITER Organization, St. Paul Lez durance Cedex, France
8 shared publications - Andrew Bruton
ITER Organization, St. Paul Lez Durance, France
6 shared publications
Latest Publications
- 5 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Calibration Test for Preload Control With Ultrasonic Checking for Magnet Studs During ITER Machine Assembly
The ITER superconducting magnet system comprises 18 Toroidal Field (TF) coils, one Central Solenoid (CS), 6 Poloidal Field (PF) coils, and 18 Correction Coils (CC). These superconducting coils are integrated using robust, flexible structures and over 4700 high-grade large studs ranging from M24 to M160. During assembly, these studs are preloaded from hundreds to thousands of kN with Hydraulic Tensioners or Multi-jack bolt Tensioners (MJT or Superbolts). Since preload losses are inevitable under current methods with hydraulic tensioners, and the maximum allowable loads are constrained by the material's yield strength as per ITER Magnet Structure Design Criteria, these constraints create a narrow operational window for successful assembly to the expected preload. Precise preload control is critical to ensuring proper integration of the superconducting magnets. Ultrasonic bolt load measurement emerges as a promising solution, especially in scenarios where one end of the stud is inaccessible after installation. Calibration tests at ITER are underway to validate the use of this method for preload measurement during machine assembly. This article presents calibration test results, including velocity, stress factor, load factor, preload loss, and field calibration measurements. It concludes with insights from the design and manufacturing of high-grade studs, highlighting their impact on achieving accurate preload control via ultrasonic inspection.
- 5 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Calibration Test for Preload Control With Ultrasonic Checking for Magnet Studs During ITER Machine Assembly
The ITER superconducting magnet system comprises 18 Toroidal Field (TF) coils, one Central Solenoid (CS), 6 Poloidal Field (PF) coils, and 18 Correction Coils (CC). These superconducting coils are integrated using robust, flexible structures and over 4700 high-grade large studs ranging from M24 to M160. During assembly, these studs are preloaded from hundreds to thousands of kN with Hydraulic Tensioners or Multi-jack bolt Tensioners (MJT or Superbolts). Since preload losses are inevitable under current methods with hydraulic tensioners, and the maximum allowable loads are constrained by the material's yield strength as per ITER Magnet Structure Design Criteria, these constraints create a narrow operational window for successful assembly to the expected preload. Precise preload control is critical to ensuring proper integration of the superconducting magnets. Ultrasonic bolt load measurement emerges as a promising solution, especially in scenarios where one end of the stud is inaccessible after installation. Calibration tests at ITER are underway to validate the use of this method for preload measurement during machine assembly. This article presents calibration test results, including velocity, stress factor, load factor, preload loss, and field calibration measurements. It concludes with insights from the design and manufacturing of high-grade studs, highlighting their impact on achieving accurate preload control via ultrasonic inspection.
- 24 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-7
ITER Central Solenoid Manufacturing and Assembly Progress
ITER Central Solenoid (CS) system manufacturing, after ten years, completed all coil modules manufacturing and testing to full current 40 kA at 4.5 K. Meanwhile the assembly work at ITER has progressed steadily since its start five years ago. A summary of characteristic technical challenges found in manufacturing and assembly, and an outlook of what is expected towards the completion of CS assembly are presented.
- 24 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-7
ITER Central Solenoid Manufacturing and Assembly Progress
ITER Central Solenoid (CS) system manufacturing, after ten years, completed all coil modules manufacturing and testing to full current 40 kA at 4.5 K. Meanwhile the assembly work at ITER has progressed steadily since its start five years ago. A summary of characteristic technical challenges found in manufacturing and assembly, and an outlook of what is expected towards the completion of CS assembly are presented.
- 10 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Residual Inductive Voltages in the Quench Detection Loops of the ITER TF Coil During Testing in the ITER Magnet Cold Test Bench
While the assembly of the ITER device is progressing, a Magnet Cold Test Bench (MCTB) is also under preparation to test some of the ITER superconducting coils at 4 k up to nominal current before their installation in the pit. In this context calculations are performed to estimate the residual inductive voltages in the quench detection loops of the TF coils during the test scenarios. These residual inductive voltages are defined as the difference between the turn and Co-Wound-Tape (CWT) voltages appearing during ramping operation. These residual voltages need to be known as they cannot be avoided and because they need to be smaller than the resistive voltage developing during a quench to allow its detection. In particular, the case of a fast discharge is investigated, which represents the most severe transient operation expected for MCTB, generating the largest possible residual inductive voltages. Once validated against the MCTB tests, the models used to predict these residual inductive voltages in the ITER TF coils, can be applied to predict these voltages during a ITER plasma pulse. This will allow the assessment by which margin quenches can be detected in the ITER TF coils during plasma operation.
- 10 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Residual Inductive Voltages in the Quench Detection Loops of the ITER TF Coil During Testing in the ITER Magnet Cold Test Bench
While the assembly of the ITER device is progressing, a Magnet Cold Test Bench (MCTB) is also under preparation to test some of the ITER superconducting coils at 4 k up to nominal current before their installation in the pit. In this context calculations are performed to estimate the residual inductive voltages in the quench detection loops of the TF coils during the test scenarios. These residual inductive voltages are defined as the difference between the turn and Co-Wound-Tape (CWT) voltages appearing during ramping operation. These residual voltages need to be known as they cannot be avoided and because they need to be smaller than the resistive voltage developing during a quench to allow its detection. In particular, the case of a fast discharge is investigated, which represents the most severe transient operation expected for MCTB, generating the largest possible residual inductive voltages. Once validated against the MCTB tests, the models used to predict these residual inductive voltages in the ITER TF coils, can be applied to predict these voltages during a ITER plasma pulse. This will allow the assessment by which margin quenches can be detected in the ITER TF coils during plasma operation.
- 6 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Preliminary Design of a Supporting Structure for the Full Current Test of ITER TF Magnet
IO (ITER Organization) planned cold tests for Toroidal Field (TF) and Poloidal Field (PF1) coils, and a test facility is under development for this specific purpose. The TF coil test campaign foresees a series of tests at half operational current and a final one at full current, 68kA. The latter requires a further development of the facility, due to the severity of the test together with a series of design constraints. Firstly, a stand-alone TF coil is subjected to a stress condition different from the operational one, since it is not part of the entire magnetic system, where centripetal actions are shared and reacted by wedging. This condition results in significant bending of the inboard leg and a strain state potentially affecting the superconductor performance. Secondly, the required supporting structures to mitigate this bending, apart from being effective in increasing the stiffness and structurally sound, must withstand strict requirements in terms of dimension, interface with other components, handling and weight. In this investigation the preliminary design of the necessary auxiliary structure is discussed. The results of the FEM mechanical and thermal analyses show how the design meets the requirements in terms of stresses in the TF coil and strain in the Winding Pack (WP), as well as the structural compliance of both coil and supporting structure, also in compliance with the requirements of assembly and handling in the facility.
- 6 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Preliminary Design of a Supporting Structure for the Full Current Test of ITER TF Magnet
IO (ITER Organization) planned cold tests for Toroidal Field (TF) and Poloidal Field (PF1) coils, and a test facility is under development for this specific purpose. The TF coil test campaign foresees a series of tests at half operational current and a final one at full current, 68kA. The latter requires a further development of the facility, due to the severity of the test together with a series of design constraints. Firstly, a stand-alone TF coil is subjected to a stress condition different from the operational one, since it is not part of the entire magnetic system, where centripetal actions are shared and reacted by wedging. This condition results in significant bending of the inboard leg and a strain state potentially affecting the superconductor performance. Secondly, the required supporting structures to mitigate this bending, apart from being effective in increasing the stiffness and structurally sound, must withstand strict requirements in terms of dimension, interface with other components, handling and weight. In this investigation the preliminary design of the necessary auxiliary structure is discussed. The results of the FEM mechanical and thermal analyses show how the design meets the requirements in terms of stresses in the TF coil and strain in the Winding Pack (WP), as well as the structural compliance of both coil and supporting structure, also in compliance with the requirements of assembly and handling in the facility.
- 4 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
EM Simulations for the ITER Magnet Cold Test Bench – TF Coil Fast Discharge
While the ITER assembly is progressing, a Magnet Cold Test Bench (MCTB) is also under preparation to test some of the ITER superconducting coils at 4 K up to nominal current before their installation in the pit. In this context transient Electro-Magnetic (EM) calculations were performed to estimate the impact of AC losses and eddy currents on the cryogenic and mechanical performance of the coils and other components of the MCTB. In particular the case of a fast exponential discharge is investigated, which represents the most severe transient operation expected for MCTB. Although different types of ITER coils are considered for the tests (several Toroidal Field Coils and Poloidal Field Coil number 1), the following discussion will be limited to the operation of a single Toroidal Field (TF) coil. Detailed results of the EM analysis, such as field maps, AC losses and QD voltages will be presented.
- 4 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
EM Simulations for the ITER Magnet Cold Test Bench – TF Coil Fast Discharge
While the ITER assembly is progressing, a Magnet Cold Test Bench (MCTB) is also under preparation to test some of the ITER superconducting coils at 4 K up to nominal current before their installation in the pit. In this context transient Electro-Magnetic (EM) calculations were performed to estimate the impact of AC losses and eddy currents on the cryogenic and mechanical performance of the coils and other components of the MCTB. In particular the case of a fast exponential discharge is investigated, which represents the most severe transient operation expected for MCTB. Although different types of ITER coils are considered for the tests (several Toroidal Field Coils and Poloidal Field Coil number 1), the following discussion will be limited to the operation of a single Toroidal Field (TF) coil. Detailed results of the EM analysis, such as field maps, AC losses and QD voltages will be presented.
- 20 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-4
Continuing Testing of the ITER CS Modules
The ITER Central Solenoid (CS) is under fabrication by the US ITER organization and its subcontractors. US ITER will supply seven modules to ITER IO, six of which will be assembled in a stack that forms the ITER Central Solenoid. All CS modules (CSM) were or will be tested at 40 kA in the Final Test facility at General Atomics (GA). CSM 5, 6, and 7 were tested in 2023 and 2024. Some instrumentation was updated to obtain information on the suppression of the inductive noise in the CSMs at high dB/dt events, which will lead to improved quench detection and protection of the modules. All the standard tests performed on previous CSMs to validate the properties of the CSM have also been performed on CSMs 5-7 to confirm the consistency of the CSM properties for ITER CS. The Tcs margin demonstration was done for the first time at the GA Facility on CSM6. Test results and analysis are presented and discussed.
- 20 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-4
Continuing Testing of the ITER CS Modules
The ITER Central Solenoid (CS) is under fabrication by the US ITER organization and its subcontractors. US ITER will supply seven modules to ITER IO, six of which will be assembled in a stack that forms the ITER Central Solenoid. All CS modules (CSM) were or will be tested at 40 kA in the Final Test facility at General Atomics (GA). CSM 5, 6, and 7 were tested in 2023 and 2024. Some instrumentation was updated to obtain information on the suppression of the inductive noise in the CSMs at high dB/dt events, which will lead to improved quench detection and protection of the modules. All the standard tests performed on previous CSMs to validate the properties of the CSM have also been performed on CSMs 5-7 to confirm the consistency of the CSM properties for ITER CS. The Tcs margin demonstration was done for the first time at the GA Facility on CSM6. Test results and analysis are presented and discussed.
- 12 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Upgrade of CICC Mechanical Model and Case Study of ITER TF Conductor in Cold Test Conditions
This paper proposes to use an upgraded version of the Multifil simulation tool to model an ITER TF-like conductor in two cases: In tokamak and in cold test conditions. After briefly introducing the Multifil code, the paper will report the latest upgrades in terms of thermal equilibrium as well as simultaneous Lorentz and coil operational loads. We will present a new post-processing of the fractured filamentary area, which relies on a memory of the fracture map along all the loading steps. Then, considering ITER is currently building a magnet coil test bench (MCTB) with the capability to cold test some of the TF coils at nominal current (68 kA) in a standalone situation, we will discuss how mechanical modelling of the TF conductor is relevant for assessing the impact of the test sequence on the Nb3Sn conductor degradation. We will present a new loading sequence, representative of the test facility conditions, with a different Lorentz force direction and amplitude with respect to tokamak operation. Furthermore, the MCTB test implies an additional over-compression of conductors located in the straight leg of the TF coil in equatorial plane. The effect of this “cold-test cycling” will be discussed in terms of mechanical behavior, fracture of strands and tentative Tcs degradation estimation.
- 12 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Upgrade of CICC Mechanical Model and Case Study of ITER TF Conductor in Cold Test Conditions
This paper proposes to use an upgraded version of the Multifil simulation tool to model an ITER TF-like conductor in two cases: In tokamak and in cold test conditions. After briefly introducing the Multifil code, the paper will report the latest upgrades in terms of thermal equilibrium as well as simultaneous Lorentz and coil operational loads. We will present a new post-processing of the fractured filamentary area, which relies on a memory of the fracture map along all the loading steps. Then, considering ITER is currently building a magnet coil test bench (MCTB) with the capability to cold test some of the TF coils at nominal current (68 kA) in a standalone situation, we will discuss how mechanical modelling of the TF conductor is relevant for assessing the impact of the test sequence on the Nb3Sn conductor degradation. We will present a new loading sequence, representative of the test facility conditions, with a different Lorentz force direction and amplitude with respect to tokamak operation. Furthermore, the MCTB test implies an additional over-compression of conductors located in the straight leg of the TF coil in equatorial plane. The effect of this “cold-test cycling” will be discussed in terms of mechanical behavior, fracture of strands and tentative Tcs degradation estimation.
- 19 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Development of the ITER Magnet Protection in the Case of Paschen Condition Detection
The ITER superconducting magnet electrical insulation is designed and manufactured to be Paschen proof. The ITER cryostat and the feeder vacuums are also designed to provide a level of vacuum where Paschen conditions should not occur in case of insulation failure. The high voltage insulation failure coincident with degraded vacuum has been identified as a risk with major consequences. The level of magnetic energy stored in the superconducting coils, up to a maximum value of about 50 GJ, could result in electrical arcs leading to severe damages on the magnet system. The present paper focus on the operation, control and protection to mitigate the risk of Paschen discharge: vacuum monitoring, detection and protective actions are discussed: what the baseline strategy is and what should be further developed and improved for the ITER magnet system based on the return of experience of large scale superconducting magnet tests.
- 19 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Development of the ITER Magnet Protection in the Case of Paschen Condition Detection
The ITER superconducting magnet electrical insulation is designed and manufactured to be Paschen proof. The ITER cryostat and the feeder vacuums are also designed to provide a level of vacuum where Paschen conditions should not occur in case of insulation failure. The high voltage insulation failure coincident with degraded vacuum has been identified as a risk with major consequences. The level of magnetic energy stored in the superconducting coils, up to a maximum value of about 50 GJ, could result in electrical arcs leading to severe damages on the magnet system. The present paper focus on the operation, control and protection to mitigate the risk of Paschen discharge: vacuum monitoring, detection and protective actions are discussed: what the baseline strategy is and what should be further developed and improved for the ITER magnet system based on the return of experience of large scale superconducting magnet tests.
- 5 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Selected Topics of Technical Challenges of the ITER Central Solenoid
Central Solenoid (CS) components have an abundance of technical challenges ranging from material science to component interfacing. In manufacturing, a CS module is subjected to stringent high voltage insulation strength tests at multiple occasions. The engineering challenge is where a multitude of quench detection wires need to exit the bulk insulation and the materials boundary or compatibility become an issue. In assembly, each CS module terminals is jumped to its respective feeder line via an extension lead that is manufactured with interfacing constraints with the module terminal vector as well as the feeder terminal mating surface. Another critical aspect is the clearance available in assembly with other surrounding tokamak components. A summary of the issues found in manufacturing of large scale structural components is also given.
- 5 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Selected Topics of Technical Challenges of the ITER Central Solenoid
Central Solenoid (CS) components have an abundance of technical challenges ranging from material science to component interfacing. In manufacturing, a CS module is subjected to stringent high voltage insulation strength tests at multiple occasions. The engineering challenge is where a multitude of quench detection wires need to exit the bulk insulation and the materials boundary or compatibility become an issue. In assembly, each CS module terminals is jumped to its respective feeder line via an extension lead that is manufactured with interfacing constraints with the module terminal vector as well as the feeder terminal mating surface. Another critical aspect is the clearance available in assembly with other surrounding tokamak components. A summary of the issues found in manufacturing of large scale structural components is also given.