Ahmed M. Abdelaal
Research Subjects
Ahmed M. Abdelaal has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Ehab M. Attalla
National Cancer Institute, Cairo University
1 shared publication- Ehab Marouf Attalla
Medical Physics Department, National Cancer Institute, Cairo University, Cairo, Egypt
1 shared publication - Limam Ahmed Neya1 shared publication
- Reem H. El-Gebaly
Biophysics Department, Faculty of Science, Cairo University, Giza, Egypt
1 shared publication - Reham Salah El-Din Sherif
Biophysics Department, Faculty of Science, Cairo University, Giza 12613 Cairo, Egypt
1 shared publication Wael M. Elshemey
Biophysics Department, Faculty of Science, Cairo University
1 shared publication
Latest Publications
- Open Access
- 8 December 2025
- Published by V. N. Karazin Kharkiv National University in East European Journal of Physics
- No. 4,p. 560-574
Optimizing Head and Neck Cancer Radiotherapy: A Dosimetric Comparison of FF and FFF Beams in VMAT
Aim: Head and neck cancer (HNC) is a significant global health concern, with rising incidence rates and a high prevalence in South Asia, particularly in India. Radiation therapy, including advanced techniques like Volumetric-Modulated Arc Therapy (VMAT) and Intensity-Modulated Radiotherapy (IMRT), plays a crucial role in treating HNC. This study aims to compare the dosimetric and biological and second cancer risk estimation differences between flattened (FF) and flattening filter-free (FFF) beams in VMAT treatment plans for HNC, focusing on the impact of 6 MV and 10 MV energies.Methods: Twenty HNC patients underwent replanning using VMAT on an ELEKTA VERSA HD linear accelerator with 6 MV FF, 6 MV FFF, 10 MV FF, and 10 MV FFF beams. Dosimetric parameters evaluated included dose distribution to planning target volumes (PTVs) and dose delivered to 98% of the target (D98), 50% (D50), and 2% (D2), as well as doses to organs at risk (OARs)., monitor units per segment (MU/Segment), number of MU/cGy, treatment delivery time, conformity index, and homogeneity index, also biological parameters (NTCP and EUD) and second cancer risk estimation were evaluated.Results: The results showed that 6 MV FFF beams provided slightly better dose-sparing for OARs compared to 6 MV FF, with no significant differences in target volume coverage. Both FF and FFF beams demonstrated comparable conformity indices, but FF beams had better homogeneity indices. FFF beams required more monitor units (MUs) and segments but offered reduced treatment delivery times. For 10 MV beams, FFF showed marginal advantages in dose homogeneity and sparing of normal tissues at lower doses, though it required more MUs and segments, this study found that NTCP and EUD were largely comparable between FF and FFF types, with minor but statistically significant differences for the brainstem (favoring FFF) and heart. Second cancer risks varied slightly by energy and technique 6MV FFF reduced parotid risks (though increased larynx risk).Conclusion: 6 MV beams, particularly FFF, showed slight advantages in sparing OARs and target volume coverage compared to 10 MV beams. This study highlights the dosimetric comparability of FF and FFF beams in HNC treatment, with FFF offering potential benefits in treatment efficiency and reduced delivery times. This study also shows that FF and FFF types yield comparable radiobiological outcomes, though 6MV FFF beams slightly reduce doses to critical organs without sacrificing efficacy. Both types perform similarly, with minor risk variations by energy.
- 8 December 2025
- Published by V. N. Karazin Kharkiv National University in East European Journal of Physics
- No. 4,p. 560-574
Open AccessOptimizing Head and Neck Cancer Radiotherapy: A Dosimetric Comparison of FF and FFF Beams in VMAT
Aim: Head and neck cancer (HNC) is a significant global health concern, with rising incidence rates and a high prevalence in South Asia, particularly in India. Radiation therapy, including advanced techniques like Volumetric-Modulated Arc Therapy (VMAT) and Intensity-Modulated Radiotherapy (IMRT), plays a crucial role in treating HNC. This study aims to compare the dosimetric and biological and second cancer risk estimation differences between flattened (FF) and flattening filter-free (FFF) beams in VMAT treatment plans for HNC, focusing on the impact of 6 MV and 10 MV energies.Methods: Twenty HNC patients underwent replanning using VMAT on an ELEKTA VERSA HD linear accelerator with 6 MV FF, 6 MV FFF, 10 MV FF, and 10 MV FFF beams. Dosimetric parameters evaluated included dose distribution to planning target volumes (PTVs) and dose delivered to 98% of the target (D98), 50% (D50), and 2% (D2), as well as doses to organs at risk (OARs)., monitor units per segment (MU/Segment), number of MU/cGy, treatment delivery time, conformity index, and homogeneity index, also biological parameters (NTCP and EUD) and second cancer risk estimation were evaluated.Results: The results showed that 6 MV FFF beams provided slightly better dose-sparing for OARs compared to 6 MV FF, with no significant differences in target volume coverage. Both FF and FFF beams demonstrated comparable conformity indices, but FF beams had better homogeneity indices. FFF beams required more monitor units (MUs) and segments but offered reduced treatment delivery times. For 10 MV beams, FFF showed marginal advantages in dose homogeneity and sparing of normal tissues at lower doses, though it required more MUs and segments, this study found that NTCP and EUD were largely comparable between FF and FFF types, with minor but statistically significant differences for the brainstem (favoring FFF) and heart. Second cancer risks varied slightly by energy and technique 6MV FFF reduced parotid risks (though increased larynx risk).Conclusion: 6 MV beams, particularly FFF, showed slight advantages in sparing OARs and target volume coverage compared to 10 MV beams. This study highlights the dosimetric comparability of FF and FFF beams in HNC treatment, with FFF offering potential benefits in treatment efficiency and reduced delivery times. This study also shows that FF and FFF types yield comparable radiobiological outcomes, though 6MV FFF beams slightly reduce doses to critical organs without sacrificing efficacy. Both types perform similarly, with minor risk variations by energy.
- Open Access
- 1 March 2020
- Published by Ital Publication in SciMedicine Journal
- Vol. 2 (1) , 8-15
Estimation of Out-of-Field Dose Variation using Markus Ionization Chamber Detector
Objective: The aim of This work to provide evaluation for the out-of-field dose with different plan parameters as field size and depth using Markus ionization chamber detector in the measurement that are frequently used in electron and superficial dosimetery, in radiotherapy. Methods: This is carried out through the application of these detector in estimation of the out-of-field dose with important dosimetric parameters such as field size (from 5×5 to 30×30 cm2) and depth (from 1.5 to 30 cm) at energy 6 MV and collimator angle 0° at SSD 100 cm. Results: Results show that, the Markus detector reported an increase in out-of-field dose with field size, depth in almost all measurements. For 6 MV and 0° collimator angle, the out-of-field dose at field size of 5×5 cm2 (depth of 1.5 cm) is 1.1% and at field size of 30×30 cm2 (depth of 1.5 cm) is 4.4% . The out-of-field dose for a depth of 1.5 cm (field size of 10×10 cm2) is 2.3% and for a depth of 30 cm (field size of 10×10 cm) is 5.5%. the measured out-of-field dose by Markus detector overestimated in the calculated at different field sizes (2.7% instead of 2.3% at field size of 10×10 cm2 and 5.2% instead of 4.4% at field size of 30×30 cm2) and different depths (2.7% instead of 1.1% at depth of 1.5 cm and 4.1% instead of 3.4% at depth of 30 cm). Analysis: The result reported an increase in mean out-of-field dose with field size, depth, energy and SSD. Markus ionization chamber detector show overestimation of the measured out-of-field dose in the calculated values at all field sizes and depths, this may be attributed to the poor detection of out-of-field dose by TPS.
- 1 March 2020
- Published by Ital Publication in SciMedicine Journal
- Vol. 2 (1) , 8-15
Open AccessEstimation of Out-of-Field Dose Variation using Markus Ionization Chamber Detector
Objective: The aim of This work to provide evaluation for the out-of-field dose with different plan parameters as field size and depth using Markus ionization chamber detector in the measurement that are frequently used in electron and superficial dosimetery, in radiotherapy. Methods: This is carried out through the application of these detector in estimation of the out-of-field dose with important dosimetric parameters such as field size (from 5×5 to 30×30 cm2) and depth (from 1.5 to 30 cm) at energy 6 MV and collimator angle 0° at SSD 100 cm. Results: Results show that, the Markus detector reported an increase in out-of-field dose with field size, depth in almost all measurements. For 6 MV and 0° collimator angle, the out-of-field dose at field size of 5×5 cm2 (depth of 1.5 cm) is 1.1% and at field size of 30×30 cm2 (depth of 1.5 cm) is 4.4% . The out-of-field dose for a depth of 1.5 cm (field size of 10×10 cm2) is 2.3% and for a depth of 30 cm (field size of 10×10 cm) is 5.5%. the measured out-of-field dose by Markus detector overestimated in the calculated at different field sizes (2.7% instead of 2.3% at field size of 10×10 cm2 and 5.2% instead of 4.4% at field size of 30×30 cm2) and different depths (2.7% instead of 1.1% at depth of 1.5 cm and 4.1% instead of 3.4% at depth of 30 cm). Analysis: The result reported an increase in mean out-of-field dose with field size, depth, energy and SSD. Markus ionization chamber detector show overestimation of the measured out-of-field dose in the calculated values at all field sizes and depths, this may be attributed to the poor detection of out-of-field dose by TPS.