Reham Salah El-Din Sherif
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Reham Salah El-Din Sherif has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed M. Abdelaal
Radiotherapy Department, Nasser Institute, Cairo
1 shared publication Badriah Alasmari
Biophysics Department, Faculty of Science, Cairo University, Giza 12613 Cairo, Egypt
1 shared publication- Ehab Marouf Attalla
Medical Physics Department, National Cancer Institute, Cairo University, Cairo, Egypt
1 shared publication Hend M Kareem
Cairo University
1 shared publicationKhalid Elsaban
Nuclear Medicine Department, Al-Hada Armed Forces Hospital, Taif, Saudi Arabia
1 shared publication- Limam Ahmed Neya1 shared publication
Latest Publications
- 27 April 2026
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 57 (4) , 102343
Diagnostic accuracy of SPECT/CT for parathyroid adenoma: Tracer selection and quality control
- 27 April 2026
- Published by Elsevier in Journal of Medical Imaging and Radiation Sciences
- Vol. 57 (4) , 102343
Diagnostic accuracy of SPECT/CT for parathyroid adenoma: Tracer selection and quality control
- Open Access
- 8 December 2025
- Published by V. N. Karazin Kharkiv National University in East European Journal of Physics
- No. 4,p. 560-574
Optimizing Head and Neck Cancer Radiotherapy: A Dosimetric Comparison of FF and FFF Beams in VMAT
Aim: Head and neck cancer (HNC) is a significant global health concern, with rising incidence rates and a high prevalence in South Asia, particularly in India. Radiation therapy, including advanced techniques like Volumetric-Modulated Arc Therapy (VMAT) and Intensity-Modulated Radiotherapy (IMRT), plays a crucial role in treating HNC. This study aims to compare the dosimetric and biological and second cancer risk estimation differences between flattened (FF) and flattening filter-free (FFF) beams in VMAT treatment plans for HNC, focusing on the impact of 6 MV and 10 MV energies.Methods: Twenty HNC patients underwent replanning using VMAT on an ELEKTA VERSA HD linear accelerator with 6 MV FF, 6 MV FFF, 10 MV FF, and 10 MV FFF beams. Dosimetric parameters evaluated included dose distribution to planning target volumes (PTVs) and dose delivered to 98% of the target (D98), 50% (D50), and 2% (D2), as well as doses to organs at risk (OARs)., monitor units per segment (MU/Segment), number of MU/cGy, treatment delivery time, conformity index, and homogeneity index, also biological parameters (NTCP and EUD) and second cancer risk estimation were evaluated.Results: The results showed that 6 MV FFF beams provided slightly better dose-sparing for OARs compared to 6 MV FF, with no significant differences in target volume coverage. Both FF and FFF beams demonstrated comparable conformity indices, but FF beams had better homogeneity indices. FFF beams required more monitor units (MUs) and segments but offered reduced treatment delivery times. For 10 MV beams, FFF showed marginal advantages in dose homogeneity and sparing of normal tissues at lower doses, though it required more MUs and segments, this study found that NTCP and EUD were largely comparable between FF and FFF types, with minor but statistically significant differences for the brainstem (favoring FFF) and heart. Second cancer risks varied slightly by energy and technique 6MV FFF reduced parotid risks (though increased larynx risk).Conclusion: 6 MV beams, particularly FFF, showed slight advantages in sparing OARs and target volume coverage compared to 10 MV beams. This study highlights the dosimetric comparability of FF and FFF beams in HNC treatment, with FFF offering potential benefits in treatment efficiency and reduced delivery times. This study also shows that FF and FFF types yield comparable radiobiological outcomes, though 6MV FFF beams slightly reduce doses to critical organs without sacrificing efficacy. Both types perform similarly, with minor risk variations by energy.
- 8 December 2025
- Published by V. N. Karazin Kharkiv National University in East European Journal of Physics
- No. 4,p. 560-574
Open AccessOptimizing Head and Neck Cancer Radiotherapy: A Dosimetric Comparison of FF and FFF Beams in VMAT
Aim: Head and neck cancer (HNC) is a significant global health concern, with rising incidence rates and a high prevalence in South Asia, particularly in India. Radiation therapy, including advanced techniques like Volumetric-Modulated Arc Therapy (VMAT) and Intensity-Modulated Radiotherapy (IMRT), plays a crucial role in treating HNC. This study aims to compare the dosimetric and biological and second cancer risk estimation differences between flattened (FF) and flattening filter-free (FFF) beams in VMAT treatment plans for HNC, focusing on the impact of 6 MV and 10 MV energies.Methods: Twenty HNC patients underwent replanning using VMAT on an ELEKTA VERSA HD linear accelerator with 6 MV FF, 6 MV FFF, 10 MV FF, and 10 MV FFF beams. Dosimetric parameters evaluated included dose distribution to planning target volumes (PTVs) and dose delivered to 98% of the target (D98), 50% (D50), and 2% (D2), as well as doses to organs at risk (OARs)., monitor units per segment (MU/Segment), number of MU/cGy, treatment delivery time, conformity index, and homogeneity index, also biological parameters (NTCP and EUD) and second cancer risk estimation were evaluated.Results: The results showed that 6 MV FFF beams provided slightly better dose-sparing for OARs compared to 6 MV FF, with no significant differences in target volume coverage. Both FF and FFF beams demonstrated comparable conformity indices, but FF beams had better homogeneity indices. FFF beams required more monitor units (MUs) and segments but offered reduced treatment delivery times. For 10 MV beams, FFF showed marginal advantages in dose homogeneity and sparing of normal tissues at lower doses, though it required more MUs and segments, this study found that NTCP and EUD were largely comparable between FF and FFF types, with minor but statistically significant differences for the brainstem (favoring FFF) and heart. Second cancer risks varied slightly by energy and technique 6MV FFF reduced parotid risks (though increased larynx risk).Conclusion: 6 MV beams, particularly FFF, showed slight advantages in sparing OARs and target volume coverage compared to 10 MV beams. This study highlights the dosimetric comparability of FF and FFF beams in HNC treatment, with FFF offering potential benefits in treatment efficiency and reduced delivery times. This study also shows that FF and FFF types yield comparable radiobiological outcomes, though 6MV FFF beams slightly reduce doses to critical organs without sacrificing efficacy. Both types perform similarly, with minor risk variations by energy.
- 19 June 2025
- Published by SAGE Publications in International Journal of Risk & Safety in Medicine
- Vol. 36 (4) , 260-269
Comparative study of brachytherapy using ring and ovoid applicators in treatment of advanced cervical cancer
Background: Image-guided brachytherapy became essential to cervical cancer treatment following chemo-radiotherapy. A variety of applicators including Tandem-Ring (TR) and Tandem-Ovoid (TO) applicators are used to apply brachytherapy. Objective: This study aims to dosimetrically compare TR versus TO applicators by using two different optimization techniques. Methods: Both applicator sets were applied to the 24 patients. The prescribed dose was 7 Gy/fraction, and the treatment plans were normalized to HR-CTV. Two different optimization techniques are applied, along the four treatment fractions. The first optimization technique was a theoretical assumption that aimed to deliver 7 Gy to 90 % of the volume of the HR-CTV. While the second was the clinical situation which aimed to preserve the organs at risk (OARs) according to the ICRU 89 dose-volume constraints, considering that, 90% of HR-CTV is covered by not less than 90% of the prescribed dose. DVHs were generated, and dosimetric parameters including point A, and D2cc of rectum, bladder, and sigmoid, as well as the dose at different volumes of HR-CTV and IR-CTV, were recorded and compared. Results: The results demonstrate that using Ovoid-Tandem applicators achieved significantly higher dose at point A, significantly higher coverage to both HR-CTV and IR-CTV, in addition to significantly better protection to the mean D2cc of the rectum in both optimization techniques. On the other hand, using Ring-Tandem applicators give significantly more protection to the mean D2cc of the bladder, but HR-CTV and IR-CTV have significantly lower coverage. Conclusion: Ovoid-Tandem and Ring-Tandem applicators are the most common interchangeable intracavitary gynecological applicators. In this study, the results demonstrated that Ovoid-Tandem applicators have the advantages of significantly higher coverage for HR-CTV, and IR-CTV, in addition to more protection for D2cc of the rectum. On the contrary, Ring-Tandem applicators can provide higher protection for D2cc of the bladder, and more comfort to the patients.
- 19 June 2025
- Published by SAGE Publications in International Journal of Risk & Safety in Medicine
- Vol. 36 (4) , 260-269
Comparative study of brachytherapy using ring and ovoid applicators in treatment of advanced cervical cancer
Background: Image-guided brachytherapy became essential to cervical cancer treatment following chemo-radiotherapy. A variety of applicators including Tandem-Ring (TR) and Tandem-Ovoid (TO) applicators are used to apply brachytherapy. Objective: This study aims to dosimetrically compare TR versus TO applicators by using two different optimization techniques. Methods: Both applicator sets were applied to the 24 patients. The prescribed dose was 7 Gy/fraction, and the treatment plans were normalized to HR-CTV. Two different optimization techniques are applied, along the four treatment fractions. The first optimization technique was a theoretical assumption that aimed to deliver 7 Gy to 90 % of the volume of the HR-CTV. While the second was the clinical situation which aimed to preserve the organs at risk (OARs) according to the ICRU 89 dose-volume constraints, considering that, 90% of HR-CTV is covered by not less than 90% of the prescribed dose. DVHs were generated, and dosimetric parameters including point A, and D2cc of rectum, bladder, and sigmoid, as well as the dose at different volumes of HR-CTV and IR-CTV, were recorded and compared. Results: The results demonstrate that using Ovoid-Tandem applicators achieved significantly higher dose at point A, significantly higher coverage to both HR-CTV and IR-CTV, in addition to significantly better protection to the mean D2cc of the rectum in both optimization techniques. On the other hand, using Ring-Tandem applicators give significantly more protection to the mean D2cc of the bladder, but HR-CTV and IR-CTV have significantly lower coverage. Conclusion: Ovoid-Tandem and Ring-Tandem applicators are the most common interchangeable intracavitary gynecological applicators. In this study, the results demonstrated that Ovoid-Tandem applicators have the advantages of significantly higher coverage for HR-CTV, and IR-CTV, in addition to more protection for D2cc of the rectum. On the contrary, Ring-Tandem applicators can provide higher protection for D2cc of the bladder, and more comfort to the patients.