Rongjian Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rongjian Xie has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Nanxi Li
Shanghai Institute of Technical Physics, Chinese Academy of Sciences , Shanghai 200083 , China
2 shared publications - Yinong Wu
Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China
2 shared publications Cheng Liu
Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China
1 shared publication- Cheng Liu
Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China
1 shared publication Depu Lu
University of Chinese Academy of Sciences, Beijing 100049, China
1 shared publicationGuangming Xu
University of Chinese Academy of Sciences, Beijing, China
1 shared publication
Latest Publications
- 20 April 2024
- Published by Springer Nature in Journal of Thermal Science
- Vol. 33 (4) , 1394-1408
Operational Characteristics of Loop Heat Pipe in Microgravity and Normal Gravity Environments
- 20 April 2024
- Published by Springer Nature in Journal of Thermal Science
- Vol. 33 (4) , 1394-1408
Operational Characteristics of Loop Heat Pipe in Microgravity and Normal Gravity Environments
- 18 November 2021
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 14 (4) , 1-17
Experimental Investigation of a Loop Heat Pipe With R245fa and R1234ze(E) as Working Fluids
Two kinds of new refrigerant R1234ze(E) and R245fa were discussed as substitutes or supplements to traditional working fluids of loop heat pipes (LHPs) based on their favorable thermophysical properties and characteristics such as being safe and environmentally friendly. Thermal characteristics of a loop heat pipe with sintering copper wick at different charging ratios were experimentally investigated under variable heat loads. The results showed that the optimal charging ratio in the loop heat pipe range from 65% to 70%, and at this charging level, the R1234ze(E) system had better start-up response, while the R245fa system presented a stronger heat transfer capacity. The characteristic temperature of R1234ze(E) system was below 35 °C, and the corresponding thermal resistance was 0.08 K/W–1.62 K/W under heat loads ranging from 5 W to 40 W. The thermal resistance of the R245fa system was 0.18 K/W–0.91 K/W under heat loads of 10 W–60 W, and the operating temperature was below 60 °C. The loop heat pipes charged with the proposed new refrigerants exhibit superb performance in room temperature applications, making them beneficial for enhancing the performance of electronics and could provide a distinctive choice for the cooling of small-sized electronics especially.
- 18 November 2021
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 14 (4) , 1-17
Experimental Investigation of a Loop Heat Pipe With R245fa and R1234ze(E) as Working Fluids
Two kinds of new refrigerant R1234ze(E) and R245fa were discussed as substitutes or supplements to traditional working fluids of loop heat pipes (LHPs) based on their favorable thermophysical properties and characteristics such as being safe and environmentally friendly. Thermal characteristics of a loop heat pipe with sintering copper wick at different charging ratios were experimentally investigated under variable heat loads. The results showed that the optimal charging ratio in the loop heat pipe range from 65% to 70%, and at this charging level, the R1234ze(E) system had better start-up response, while the R245fa system presented a stronger heat transfer capacity. The characteristic temperature of R1234ze(E) system was below 35 °C, and the corresponding thermal resistance was 0.08 K/W–1.62 K/W under heat loads ranging from 5 W to 40 W. The thermal resistance of the R245fa system was 0.18 K/W–0.91 K/W under heat loads of 10 W–60 W, and the operating temperature was below 60 °C. The loop heat pipes charged with the proposed new refrigerants exhibit superb performance in room temperature applications, making them beneficial for enhancing the performance of electronics and could provide a distinctive choice for the cooling of small-sized electronics especially.
- 9 August 2021
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 14 (5)
Analysis of Condensation Flow Pattern and Heat Transfer of a Cryogenic Loop Heat Pipe With Different Heating Powers
The cryogenic fluids’ flow performance and condensation characteristics with different heating powers in cryogenic loop heat pipes (CLHPs) have not been studied due to the difficulty of measurement at low temperature. In this study, a test system was designed and fabricated to characterize the condensation flow patterns of propylene CLHP and its heat transfer performance with different heating powers. The results show that the two-phase region length and flow pattern in the condenser were closely related to the operation mode of the CLHP. The vapor front in the condenser oscillated at the condenser inlet at a low heating power, which resulted in an unstable operation of the CLHP. Moreover, by comparing the condensation heat transfer coefficient (HTC) with the condensation correlations, the Cavallini correlation is recommended for the design of the CLHP condenser.
- 9 August 2021
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 14 (5)
Analysis of Condensation Flow Pattern and Heat Transfer of a Cryogenic Loop Heat Pipe With Different Heating Powers
The cryogenic fluids’ flow performance and condensation characteristics with different heating powers in cryogenic loop heat pipes (CLHPs) have not been studied due to the difficulty of measurement at low temperature. In this study, a test system was designed and fabricated to characterize the condensation flow patterns of propylene CLHP and its heat transfer performance with different heating powers. The results show that the two-phase region length and flow pattern in the condenser were closely related to the operation mode of the CLHP. The vapor front in the condenser oscillated at the condenser inlet at a low heating power, which resulted in an unstable operation of the CLHP. Moreover, by comparing the condensation heat transfer coefficient (HTC) with the condensation correlations, the Cavallini correlation is recommended for the design of the CLHP condenser.
- 15 April 2021
- Published by Springer Nature in Journal of Thermal Science
- Vol. 30 (5) , 1803-1813
Experimental Investigation and Visualization Study of the Condensation Characteristics in a Propylene Loop Heat Pipe
- 15 April 2021
- Published by Springer Nature in Journal of Thermal Science
- Vol. 30 (5) , 1803-1813
Experimental Investigation and Visualization Study of the Condensation Characteristics in a Propylene Loop Heat Pipe
- 1 January 2020
- Published by Science China Press., Co. Ltd. in Chinese Science Bulletin
- Vol. 65 (12) , 1141-1150
Startup characteristics of a multi-evaporator cryogenic loop heat pipe
- 1 January 2020
- Published by Science China Press., Co. Ltd. in Chinese Science Bulletin
- Vol. 65 (12) , 1141-1150
Startup characteristics of a multi-evaporator cryogenic loop heat pipe