Cheng Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Cheng Liu has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Guangming Xu
University of Chinese Academy of Sciences, Beijing 100049, China
1 shared publication - Nanxi Li
Shanghai Institute of Technical Physics, Chinese Academy of Sciences , Shanghai 200083 , China
1 shared publication - Rongjian Xie
Shanghai Institution of Technology and Physics, Shanghai, China
1 shared publication
Latest Publications
- 18 November 2021
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 14 (4) , 1-17
Experimental Investigation of a Loop Heat Pipe With R245fa and R1234ze(E) as Working Fluids
Two kinds of new refrigerant R1234ze(E) and R245fa were discussed as substitutes or supplements to traditional working fluids of loop heat pipes (LHPs) based on their favorable thermophysical properties and characteristics such as being safe and environmentally friendly. Thermal characteristics of a loop heat pipe with sintering copper wick at different charging ratios were experimentally investigated under variable heat loads. The results showed that the optimal charging ratio in the loop heat pipe range from 65% to 70%, and at this charging level, the R1234ze(E) system had better start-up response, while the R245fa system presented a stronger heat transfer capacity. The characteristic temperature of R1234ze(E) system was below 35 °C, and the corresponding thermal resistance was 0.08 K/W–1.62 K/W under heat loads ranging from 5 W to 40 W. The thermal resistance of the R245fa system was 0.18 K/W–0.91 K/W under heat loads of 10 W–60 W, and the operating temperature was below 60 °C. The loop heat pipes charged with the proposed new refrigerants exhibit superb performance in room temperature applications, making them beneficial for enhancing the performance of electronics and could provide a distinctive choice for the cooling of small-sized electronics especially.
- 18 November 2021
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 14 (4) , 1-17
Experimental Investigation of a Loop Heat Pipe With R245fa and R1234ze(E) as Working Fluids
Two kinds of new refrigerant R1234ze(E) and R245fa were discussed as substitutes or supplements to traditional working fluids of loop heat pipes (LHPs) based on their favorable thermophysical properties and characteristics such as being safe and environmentally friendly. Thermal characteristics of a loop heat pipe with sintering copper wick at different charging ratios were experimentally investigated under variable heat loads. The results showed that the optimal charging ratio in the loop heat pipe range from 65% to 70%, and at this charging level, the R1234ze(E) system had better start-up response, while the R245fa system presented a stronger heat transfer capacity. The characteristic temperature of R1234ze(E) system was below 35 °C, and the corresponding thermal resistance was 0.08 K/W–1.62 K/W under heat loads ranging from 5 W to 40 W. The thermal resistance of the R245fa system was 0.18 K/W–0.91 K/W under heat loads of 10 W–60 W, and the operating temperature was below 60 °C. The loop heat pipes charged with the proposed new refrigerants exhibit superb performance in room temperature applications, making them beneficial for enhancing the performance of electronics and could provide a distinctive choice for the cooling of small-sized electronics especially.