Jesús Eduardo González Ruíz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jesús Eduardo González Ruíz has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Yadir Torres
Department of Engineering and Materials Science and Transportation, University of Seville, Seville, Spain
3 shared publications - Alberto Picardo
Universidad de Sevilla
2 shared publications - Amanda Robau-Porrua
Departamento de Metalurgia, Facultad de Ingeniería, Universidad de Concepción
2 shared publications Adrian Paz Ramos
Université de Montréal, Canada
1 shared publication- Adrian Paz Ramos
Université de Montréal, Canada
1 shared publication - Alejandro López Cruz
Autonomous University of Nuevo León, Mexico; University of Havana, Cuba
1 shared publication
Latest Publications
- 11 August 2025
- Published by Springer Nature
- p. 161-169
Development of a Dental Implant Using Selective Laser Melting (SLM)
- 11 August 2025
- Published by Springer Nature
- p. 161-169
Development of a Dental Implant Using Selective Laser Melting (SLM)
- Open Access
A Finite Element Analysis of a New Dental Implant Design: The Influence of the Diameter, Length, and Material of an Implant on Its Biomechanical Behavior
It is widely recognized that excessive stress and/or strain can lead to peri-implant bone atrophy; therefore, the clinical success of dental implants is intrinsically related to their biomechanical behavior. This study evaluates the influence of the diameter, length, and material [Ti6Al4V (α+β Ti) and Ti35Nb7Zr5Ta (β-Ti)] of a novel cylindrical dental implant on stress and strain levels within maxillary bone of type II quality. The implant design aims to ensure an appropriate distribution of stresses and strains within the peri-implant bone structures (cortical and trabecular bones) while also facilitating surgical machining by requiring a simple, linear, and less expensive bone incision. This approach minimizes the risk of thermal necrosis, a common complication in osteotomies for conical implants that can lead to peri-implant bone loss. Using finite element analysis, stress and strain patterns were evaluated in the maxillary second premolar region under static delayed loading. The results reveal that the cortical bone strains remained below the critical threshold (0.003) to prevent resorption. In the trabecular bone, only larger diameter/length configurations satisfied the previous strain criterion. In all simulations, trabecular bone stress remained below 3 MPa, whereas cortical bone stress peaked at 78 MPa. Notably, the implant model with the largest diameter/length minimized stress and strain concentrations in type II bone when compared to smaller designs, thereby demonstrating its biomechanical advantage.
Open AccessA Finite Element Analysis of a New Dental Implant Design: The Influence of the Diameter, Length, and Material of an Implant on Its Biomechanical Behavior
It is widely recognized that excessive stress and/or strain can lead to peri-implant bone atrophy; therefore, the clinical success of dental implants is intrinsically related to their biomechanical behavior. This study evaluates the influence of the diameter, length, and material [Ti6Al4V (α+β Ti) and Ti35Nb7Zr5Ta (β-Ti)] of a novel cylindrical dental implant on stress and strain levels within maxillary bone of type II quality. The implant design aims to ensure an appropriate distribution of stresses and strains within the peri-implant bone structures (cortical and trabecular bones) while also facilitating surgical machining by requiring a simple, linear, and less expensive bone incision. This approach minimizes the risk of thermal necrosis, a common complication in osteotomies for conical implants that can lead to peri-implant bone loss. Using finite element analysis, stress and strain patterns were evaluated in the maxillary second premolar region under static delayed loading. The results reveal that the cortical bone strains remained below the critical threshold (0.003) to prevent resorption. In the trabecular bone, only larger diameter/length configurations satisfied the previous strain criterion. In all simulations, trabecular bone stress remained below 3 MPa, whereas cortical bone stress peaked at 78 MPa. Notably, the implant model with the largest diameter/length minimized stress and strain concentrations in type II bone when compared to smaller designs, thereby demonstrating its biomechanical advantage.
- Open Access
- 1 January 2024
- Published by Universidad de Antioquia in Revista Facultad de Ingeniería Universidad de Antioquia
- No. 112
Use of rice husk as hot tipping on steel casting parts
The use of feeding aids in the foundry process has become widespread globally recent decades, leading to increased efficiency. This article examines the characterization of rice husks, their ashes, and their positive impact as hot topping on the efficiency of open risers in casting cylindrical parts made of AISI 1045 steel. The rice husks were analyzed through X-Ray Diffraction test, Thermal-Gravimetric Analysis, and Differential Thermal-Gravimetric Analysis, while the ashes were characterized using X-Ray Diffraction. The analyzed rice husks were found to contain cellulose and low crystallinity silicon, whereas the ashes primarily consisted of cristobalite and tridymite. It was observed that the thermal decomposition of rice husks occurs in three stages, with approximately 81% of the mass lost during their combustion as hot topping on liquid steel. The location of cavities contraction in the risers of casting parts was made through longitudinal cut of the part-riser system. The increase in the rice husks topping layer thickness positively influences the concentration of these cavities on the upper surface and enhances the feeder's efficiency.
- 1 January 2024
- Published by Universidad de Antioquia in Revista Facultad de Ingeniería Universidad de Antioquia
- No. 112
Open AccessUse of rice husk as hot tipping on steel casting parts
The use of feeding aids in the foundry process has become widespread globally recent decades, leading to increased efficiency. This article examines the characterization of rice husks, their ashes, and their positive impact as hot topping on the efficiency of open risers in casting cylindrical parts made of AISI 1045 steel. The rice husks were analyzed through X-Ray Diffraction test, Thermal-Gravimetric Analysis, and Differential Thermal-Gravimetric Analysis, while the ashes were characterized using X-Ray Diffraction. The analyzed rice husks were found to contain cellulose and low crystallinity silicon, whereas the ashes primarily consisted of cristobalite and tridymite. It was observed that the thermal decomposition of rice husks occurs in three stages, with approximately 81% of the mass lost during their combustion as hot topping on liquid steel. The location of cavities contraction in the risers of casting parts was made through longitudinal cut of the part-riser system. The increase in the rice husks topping layer thickness positively influences the concentration of these cavities on the upper surface and enhances the feeder's efficiency.
- Open Access
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Matéria (Rio de Janeiro)
- Vol. 25 (4)
Effect of chemical and thermochemical treatments on the surface properties of commercially pure titanium
Chemical and physical methods have been generally used for modifying the surface of titanium implants with the aim of achieving better osseointegration. In this work, an evaluation of the effect of different chemicals and thermochemical treatments on the surface modification of titanium was carried out. Plates of commercially pure titanium were polished and treated with four different methods. Scanning electron microscopy, atomic force microscopy, energy-dispersive X-ray spectroscopy, infrared spectroscopy, X-ray diffraction and drop shape analysis were used to characterize the modified titanium surface. Our results showed that the AEPTTT surface exhibited the highest Ra values followed by AEAT, AEPT, polished Ti and AE samples. In addition, the AEAT and AEPTTT treatments developed the largest surface area, while the AE treatment produced the lowest surface area. Furthermore, the AEAT treatment created the most hydrophilic surface, which is known to positively affect the osseointegration rate of dental implants.
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Matéria (Rio de Janeiro)
- Vol. 25 (4)
Open AccessEffect of chemical and thermochemical treatments on the surface properties of commercially pure titanium
Chemical and physical methods have been generally used for modifying the surface of titanium implants with the aim of achieving better osseointegration. In this work, an evaluation of the effect of different chemicals and thermochemical treatments on the surface modification of titanium was carried out. Plates of commercially pure titanium were polished and treated with four different methods. Scanning electron microscopy, atomic force microscopy, energy-dispersive X-ray spectroscopy, infrared spectroscopy, X-ray diffraction and drop shape analysis were used to characterize the modified titanium surface. Our results showed that the AEPTTT surface exhibited the highest Ra values followed by AEAT, AEPT, polished Ti and AE samples. In addition, the AEAT and AEPTTT treatments developed the largest surface area, while the AE treatment produced the lowest surface area. Furthermore, the AEAT treatment created the most hydrophilic surface, which is known to positively affect the osseointegration rate of dental implants.
- Open Access
- 5 January 2017
- Published by FapUNIFESP (SciELO) in Materials Research
- Vol. 20 (1) , 168-174
Deposition of Multicomponent Chromium Carbide Coatings Using a Non-Conventional Source of Chromium and Silicon with Micro-Additions of Boron
The chromium carbide coatings are widely used in the mechanical industry due to its corrosion resistance and mechanical properties. In this work, we evaluated a new source of chromium and silicon with micro-additions of boron on the deposition of multi-component coatings of chromium carbides in W108 steel. The coatings were obtained by the pack cementation method, using a simultaneous deposition at 1000 oC for 4h. The coatings were analyzed by X-ray diffraction, X-ray energy dispersive spectroscopy, optical microscopy, microhardness test method and pin-on-disc wear test. It was found that the coatings formed on W108 steel were mainly constituted by (Cr,Fe)23C6, (Cr,Fe)7C3, Cr5-xSi3-xCx+z, Cr3B0,44C1,4 and (or) Cr7BC4. The carbide layers showed thicknesses between 14 and 15 µm and maximum values of microhardness between 15.8 and 18.8 GPa. Also, the micro-additions of boron to the mixtures showed statistically significant influence on the thickness, microhardness and abrasive wear resistance of the carbide coatings.
- 5 January 2017
- Published by FapUNIFESP (SciELO) in Materials Research
- Vol. 20 (1) , 168-174
Open AccessDeposition of Multicomponent Chromium Carbide Coatings Using a Non-Conventional Source of Chromium and Silicon with Micro-Additions of Boron
The chromium carbide coatings are widely used in the mechanical industry due to its corrosion resistance and mechanical properties. In this work, we evaluated a new source of chromium and silicon with micro-additions of boron on the deposition of multi-component coatings of chromium carbides in W108 steel. The coatings were obtained by the pack cementation method, using a simultaneous deposition at 1000 oC for 4h. The coatings were analyzed by X-ray diffraction, X-ray energy dispersive spectroscopy, optical microscopy, microhardness test method and pin-on-disc wear test. It was found that the coatings formed on W108 steel were mainly constituted by (Cr,Fe)23C6, (Cr,Fe)7C3, Cr5-xSi3-xCx+z, Cr3B0,44C1,4 and (or) Cr7BC4. The carbide layers showed thicknesses between 14 and 15 µm and maximum values of microhardness between 15.8 and 18.8 GPa. Also, the micro-additions of boron to the mixtures showed statistically significant influence on the thickness, microhardness and abrasive wear resistance of the carbide coatings.