Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fernando Luiz Lavoie has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Uso de resíduo fresado de pavimento asfáltico para melhoria de solo laterítico argiloso em base de rodovias

    by Gustavo Antezana Fajardo, Clara Souza de Oliveira, Rafael Ribeiro Plácido, Tiago De Jesus Souza, Fernando Luiz Lavoie

    O aumento da produção de resíduo fresado de pavimento asfáltico tem promovido a necessidade de realizar pesquisas sobre seu reaproveitamento na construção de camadas de suporte em obras rodoviárias, visando ganhos ambientais e econômicos. Este trabalho apresenta uma investigação de compósitos formados por solo laterítico argiloso e resíduo fresado de pavimento asfáltico (RFPA) nas proporções de 100/0, 75/25, 50/50 e 25/75 (solo/RFPA, percentual em massa), realizada por meio de ensaio de compactação de Proctor na energia modificada, cisalhamento direto, e módulo de resiliência. A presença do RFPA nos compósitos conferiu melhorias no comportamento mecânico às misturas 75/25 e 50/50, evidenciada por módulos resilientes, coesões e ângulos de atrito maiores. Ademais, os ensaios demonstraram que as amostras com adição de 50% de RFPA fornece melhor equilíbrio entre a rigidez dinâmica e a resistência ao cisalhamento, recomendando-se seu uso em bases de pavimentos.


  • PERFORMANCE OF AN ENVIRONMENTAL PROTECTION LINER AFTER LABORATORY UV EXPOSURE

    by Fernando Luiz Lavoie, Marcelo Kobelnik, Clever Valentin, Érica Fernanda Tirelli, Maria Lopes, Jefferson da Silva

    High-density polyethylene (HDPE) geomembranes are commonly used as an environmental protection liner due to their good chemical and mechanical resistances and low cost. Ultraviolet (UV) radiation is an essential issue in durability studies for pond applications. This study evaluated a 1.5-mm thick HDPE geomembrane exposed to ultraviolet fluorescent radiation for 8760 h in a laboratory and thermoanalytical and physical analyses were conducted towards the understanding of its performance after exposure. According to the results, although the geomembrane maintained the ductile behavior, it showed a 52.48% final decrease in stress crack resistance (SCR) compared to virgin SCR. Moreover, a considerable antioxidant depletion occurred after 8760 h exposure shown by the Std. OIT (standard oxidative-induction time) results, demonstrating a Std. OIT value decrease of 89.19% compared to the virgin Std. OIT. Such a behavior contributed to the susceptibility of thermal effects in the DSC (differential scanning calorimetry) curves and the losses observed in the SCR values, attesting the geomembrane’s oxidative degradation mechanism occurred and changed the polymer’s structure.


  • Open Access

    Study of heat and UV radiation exposures on HDPE geomembranes

    by Fernando Luiz Lavoie, Marcelo Kobelnik, Clever Aparecido Valentin, Maria de Lurdes Lopes, Jefferson Lins da Silva, Ennio Marques Palmeira


  • Open Access

    AVALIAÇÃO DA INFLUÊNCIA DE DANOS NA PERMEAÇÃO E DIFUSÃO DE GEOMEMBRANAS POLIMÉRICAS

    by Júlia Bosso Mello, Fernando Luiz Lavoie, Paulo César Lodi

    As geomembranas têm sido empregadas com o objetivo de impermeabilizar e proteger o solo e também os lençóis freáticos e mananciais. No entanto, durante o processo de instalação estas podem tornar-se suscetíveis à ocorrência de danos mecânicos (furos, microfuros e/ou rasgos). Dessa forma, os parâmetros de permeabilidade/permeação podem ser afetados e, caso ocorram vazamentos, fugas ou pequenas imperfeições que aumentem o fluxo através da geomembrana, a obra toda terá perdido sua função levando à falência do projeto. Nesse contexto, torna-se imprescindível o estudo da permeação e do processo difusivo em geomembranas poliméricas, permitindo garantir que suas propriedades estejam dentro dos parâmetros para qual foi projetada. Assim, essa pesquisa avaliou as propriedades de permeação e difusão de geomembranas de polietileno de alta densidade (PEAD) e poli cloreto de vinila (PVC) nas espessuras de 1,0 mm quando em contato com água e hidrocarbonetos. Foram avaliadas geomembranas intactas e com danos induzidos (microfuros, furos e por processos de abrasão). Os ensaios de permeação foram realizados de acordo com as recomendações da ASTM E96. O ensaio de difusão foi realizado com equipamento desenvolvido e com o auxílio da técnica de cromatografia gasosa. Para tanto foram avaliados dois tipos de solos locais (arenoso e argiloso). Os principais resultados mostram que os danos causados às geomembranas influenciaram significativamente os valores de permeação. A cromatografia gasosa mostrou-se extremamente eficaz na detecção de compostos do tipo BTEX.

  • Open Access

    Environmental protection liner in a biodegradable waste pond: A case study

    by Fernando Luiz Lavoie, Marcelo Kobelnik, Clever Aparecido Valentin, Érica Fernanda da Silva Tirelli, Maria de Lurdes Lopes, Jefferson Lins da Silva


  • Open Access

    Environmental Protection with HDPE Geomembranes in Mining Facility Constructions

    by Fernando Luiz Lavoie, Marcelo Kobelnik, Clever Aparecido Valentin, Érica Fernanda da Silva Tirelli, Maria de Lurdes Lopes, Jefferson Lins da Silva

    The present work evaluated two high-density polyethylene (HDPE) geomembranes exhumed from mining facility constructions in Brazil. The MIN sample was exhumed from a pond for water use for the iron ore process after 7.92 years of exposure. The MIN2 sample was exhumed from a spillway channel of a ferronickel tailing dam after 10.08 years of service. The physical evaluations showed high depletion for antioxidants that work in the temperature range of 200 °C. The samples presented brittle tensile behavior and had similar behaviors between stress cracking and tensile. Low tensile elongation values and low-stress crack resistance were noted. The MIN2 sample presented a higher melt flow index (MFI) value and lower stress crack resistance. Thermogravimetric curves (TG) under synthetic air purge gas evaluation showed that both samples presented a similar behavior during the evaluation but had several mass losses. The results showed that exothermic and endothermic events occurred with loss of mass and showed no combustion events in the differential thermal analysis (DTA) curve evaluation. Differential scanning calorimetry (DSC) analysis showed no changes in the samples’ behavior. Thus, the results of tensile, stress cracking, and viscosity properties can demonstrate that changes in polymer structure occurred after field exposures.


  • Open Access

    Laboratory Study of the Ultraviolet Radiation Effect on an HDPE Geomembrane

    by Fernando Luiz Lavoie, Marcelo Kobelnik, Clever Aparecido Valentin, Érica Fernanda da Silva Tirelli, Maria de Lurdes Lopes, Jefferson Lins da Silva

    High-density polyethylene (HDPE) geomembranes are polymeric geosynthetic materials usually applied as a liner in environmental facilities due to their good mechanical properties, good welding conditions, and excellent chemical resistance. A geomembrane’s field performance is affected by different conditions and exposures, including ultraviolet radiation, thermal and oxidative exposure, and chemical contact. This article presents an experimental study with a 1.0 mm-thick HDPE virgin geomembrane exposed by the Xenon arc weatherometer for 2160 h and the ultraviolet fluorescent weatherometer for 8760 h to understand the geomembrane’s behavior under ultraviolet exposure. The evaluation was performed using the melt flow index (MFI) test, oxidative-induction time (OIT) tests, tensile test, differential scanning calorimetry (DSC) analysis, and Fourier transform infrared spectroscopy (FTIR) analysis. The sample exposed in the Xenon arc equipment showed a tendency to increase the MFI values during the exposure time. This upward trend may indicate morphological changes in the polymer. The tensile behavior analysis showed a tendency of the sample to lose ductility, without showing brittle behavior. The samples’ OIT test results under both device exposures showed faster antioxidant depletion for the standard OIT test than the high-pressure OIT test. The DSC and FTIR analyses did not demonstrate the polymer’s changes.


  • Open Access

    Study of the Ultraviolet Effect and Thermal Analysis on Polypropylene Nonwoven Geotextile

    by Clever Aparecido Valentin, Marcelo Kobelnik, Yara Barbosa Franco, Fernando Luiz Lavoie, Jefferson Lins da Silva, Marta Pereira da Luz

    The use of polymeric materials such as geosynthetics in infrastructure works has been increasing over the last decades, as they bring down costs and provide long-term benefits. However, the aging of polymers raises the question of its long-term durability and for this reason researchers have been studying a sort of techniques to search for the required renewal time. This paper examined a commercial polypropylene (PP) nonwoven geotextile before and after 500 h and 1000 h exposure to ultraviolet (UV) light by performing laboratory accelerated ultraviolet-aging tests. The state of the polymeric material after UV exposure was studied through a wide set of tests, including mechanical and physical tests and thermoanalytical tests and scanning electron microscopy analysis. The calorimetric evaluations (DSC) showed distinct behaviors in sample melting points, attributed to the UV radiation effect on the aged samples. Furthermore, after exposure, the samples presented low thermal stability in the thermomechanical analysis (TMA), with a continuing decrease in their thicknesses. The tensile tests showed an increase in material stiffness after exposition. This study demonstrates that UV aging has effects on the properties of the polypropylene polymer.


  • Open Access

    HDPE Geomembranes for Environmental Protection: Two Case Studies

    by Fernando Luiz Lavoie, Clever Aparecido Valentin, Marcelo Kobelnik, Jefferson Lins da Silva, Maria de Lurdes Lopes

    High-density polyethylene (HDPE) geomembranes have been used for different applications in engineering including sanitation, such as landfills and waste liquid ponds. For these applications, the material can be exposed to aging mechanisms as thermal and chemical degradation, even to UV radiation and biological contact, which can degrade the geomembrane and decrease the material’s durability. This paper aims to present an experimental evaluation of two exhumed HDPE geomembranes, the first was used for 2.75 years in a sewage treatment aeration pond (LTE sample) and another was used for 5.17 years in a municipal landfill leachate pond (LCH sample). Physical and thermal analyses were used such as thermogravimetry (TG), differential thermal analysis (DTA), differential scanning calorimetry (DSC) and dynamic mechanic analysis (DMA). The thermogravimetric analyses showed significant changes in the LCH sample’s thermal decomposition probably caused by the interaction reactions between the polymer and the leachate. For the DSC analyses, the behavior seen in the LTE sample was not observed in the LCH sample. In the DMA analyses, the behavior of the LTE sample storage module shows which LCH sample is less brittle. The LTE sample presented low stress cracking resistance and low tensile elongation at break, following the DMA results.


  • DURABILITY OF HDPE GEOMEMBRANES: AN OVERVIEW

    by Fernando Lavoie, Marcelo Kobelnik, Clever Valentin, Jefferson Da Silva