TRTeena Rajan

Teena Rajan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Teena Rajan has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Graphite Development From a Manufacturers Perspective: Processing, Formation, and Benchmarking

    by Elizabeth E. Oseland, Teena S. Rajan, Michael Lain, Daniela Proprentner, Harriet Dutton, Andrew Bostwick, Paul Siddy, David Wilson, Louis F.J. Piper

    Graphite remains the most widely used anode material in lithium-ion batteries, and the initial formation of the solid electrolyte interphase (SEI) largely dictates the long-term performance of commercial cells. Developing a new graphite anode to diversify the supply chain remains challenging due to proprietary formation protocols and inconsistent test formats. In this study, we evaluate a pitch-coated synthetic graphite developed by James Durrans & Sons against a commercial benchmark using a harmonized methodology across a coin, three-electrode PAT cell, and pilot line built single-layer pouch cells. By standardizing electrode morphology, formation procedures, and testing conditions, we isolate the influence of active material properties, e.g., how the first cycle loss is linked to SEI formation and how coatings and cycling conditions such as temperature can influence it. Under “like for like” comparative studies of NMC 811//graphite pouch cell, the modified synthetic graphite developed displayed higher rate performance and increased capacity retention at 1C over 200 cycles over established commercial counterparts.


  • Open Access

    Graphite Development from a Manufacturers Perspective: Processing, Formation and Benchmarking

    by Elizabeth Oseland, Teena Rajan, Michael Lain, Daniela Proprentner, Harriet Dutton, Andrew Bostwick, Paul Siddy, David Wilson, Louis Piper

    Graphite remains the most widely used anode material in lithium-ion batteries, and the initial formation of the solid electrolyte interphase (SEI) largely dictates the long-term performance of commercial cells. Developing new graphite anode to diversify the supply chain remains challenging due to proprietary formation protocols and inconsistent test formats. In this study, we evaluate a pitch-coated synthetic graphite developed by James Durrans & Sons against a commercial benchmark using a harmonized methodology across coin, 3 electrode PAT cell, and pilot line built single-layer pouch cells. By standardizing electrode morphology, formation procedures, and testing conditions, we isolate the influence of active material properties e.g. how first cycle loss is linked to SEI formation and how coatings and cycling conditions (e.g. temperature and additives) can influence it. Under “like for like” comparative studies of NMC 811//graphite pouch cell, the modified synthetic graphite developed displayed higher rate performance and increased capacity retention at 1C over 200 cycles over established commercial counterparts.

  • Open Access

    Dicobalt(ii) helices kill colon cancer cells via enantiomer-specific mechanisms; DNA damage or microtubule disruption

    by Hualong Song, Hana Kostrhunova, Jakub Cervinka, Julie Macpherson, Jaroslav Malina, Teena Rajan, Roger Phillips, Miles Postings, Samantha Shepherd, Xuejian Zhang, et al.

    Highly diastereoselective self-assembly reactions give both enantiomers (Λ and Δ) of anti-parallel triple-stranded bimetallic Co(II) and Co(III) cationic helices, without the need for resolution; the first such reaction for Co. The complexes are water soluble and stable, even in the case of Co(II). Studies in a range of cancer and healthy cell lines indicate high activity and selectivity, and substantial differences between enantiomers. The oxidation state has little effect, and correspondingly, Co(III) compounds are reduced to Co(II) e.g. by glutathione. In HCT116 colon cancer cells the Λ enantiomer induces dose-dependent G2-M arrest in the cell cycle and disrupts microtubule architectures. This Co(II) Λ enantiomer is ca. five times more potent than the isostructural Fe(II) compound. Since the measured cellular uptakes are similar this implies a higher affinity of the Co system for the intracellular target(s); while the two systems are isostructural they have substantially different charge distributions as shown by calculated hydrophobicity maps. In contrast to the Λ enantiomer, Δ-Co(II) induces G1 arrest in HCT116 cells, efficiently inhibits the topoisomerase I-catalyzed relaxation of supercoiled plasmid DNA, and, unlike the isostructural Fe(II) system, causes DNA damage. It thus seems very likely that redox chemistry plays a role in the latter.


  • Ex Vivo Electrochemical pH Mapping of the Gastrointestinal Tract in the Absence and Presence of Pharmacological Agents

    by Teena S. Rajan, Tania L. Read, Aya Abdalla, Bhavik A. Patel, Julie V. Macpherson

    Ex vivo pH profiling of the upper gastrointestinal (GI) tract (of a mouse), using an electrochemical pH probe, in both the absence and presence of pharmacological agents aimed at altering acid/bicarbonate production, is reported. Three pH electrodes were first assessed for suitability using a GI tract biological mimic buffer solution containing 0.5% mucin. These include a traditional glass pH probe, an iridium oxide (IrOx)-coated electrode (both operated potentiometrically), and a quinone (Q) surface-integrated boron-doped diamond (BDD-Q) electrode (voltammetric). In mucin, the time scale for both IrOx and glass to provide a representative pH reading was in the ∼100’s of s, most likely due to mucin adsorption, in contrast to 6 s with the BDD-Q electrode. Both the glass and IrOx pH electrodes were also compromised on robustness due to fragility and delamination (IrOx) issues; contact with the GI tissue was an experimental requirement. BDD-Q was deemed the most appropriate. Ten measurements were made along the GI tract, esophagus (1), stomach (5), and duodenum (4). Under buffer only conditions, the BDD-Q probe tracked the pH from neutral in the esophagus to acidic in the stomach and rising to more alkaline in the duodenum. In the presence of omeprazole, a proton pump inhibitor, the body regions of the stomach exhibited elevated pH levels. Under melatonin treatment (a bicarbonate agonist and acid inhibitor), both the body of the stomach and the duodenum showed elevated pH levels. This study demonstrates the versatility of the BDD-Q pH electrode for real-time ex vivo biological tissue measurements.


  • Open Access

    Ex-vivo Electrochemical pH Mapping of the Gastrointestinal Tract in the Absence and Presence of Pharmacological Agents

    by Teena Rajan, Tania Read, Aya Abdalla, Bhavik Patel, Julie Macpherson

    Ex-vivo pH profiling of the upper gastrointestinal (GI) tract (of a mouse) in both the absence and presence of pharmacological agents aimed at altering acid/bicarbonate production, is reported using an electrochemical pH probe, for the first time. Three pH electrodes were assessed for suitability using a GI tract biological mimic buffer solution containing 0.5 % mucin. These include a traditional glass pH probe, an iridium oxide (IrOx) coated electrode (both potentiometric) and a quinone (Q) surface-integrated boron doped diamond (BDD-Q) electrode (voltammetric). In mucin the timescale for both IrOx and glass to obtain stable pH readings was in the ~100’s of s, most likely due to mucin adsorption, in contrast to 6 s with the BDD-Q electrode. Both the glass and IrOx pH electrodes were also compromised on robustness due to fragility and delamination (IrOx); contact with the GI tissue was an experimental requirement. BDD-Q was deemed the most appropriate. Ten measurements were made along the GI tract, esophagus (1), stomach (5) and duodenum (4). Under untreated conditions (buffer only), the BDD-Q probe tracked the pH from neutral in the esophagus, to acidic in the stomach and rising to more alkaline in the duodenum. In the presence of omeprazole, a proton pump inhibitor, the body regions of the stomach exhibited elevated pH levels. Under melatonin treatment (a bicarbonate agonist and acid inhibitor), both the body of the stomach and the duodenum showed elevated pH levels. This study demonstrates the versatility of the BDD-Q pH electrode for real-time ex-vivo biological tissue measurements.

  • A Coupling Approach for the Generation of α,α-Bis(enolate) Equivalents: Regioselective Synthesis of gem-Difunctionalized Ketones

    by Carmelo E. Iacono, Thomas C. Stephens, Teena S. Rajan, Graham Pattison

    Regioselective α,α-difunctionalization adjacent to a ketone is a significant synthetic challenge. Here we present a solution to this problem through the transition-metal-free coupling of esters with geminal bis(boron) compounds. This forms a α,α-bis(enolate) equivalent which can be trapped with electrophiles including alkyl halides and fluorinating agents. This presents an efficient, convergent synthetic strategy for the synthesis of unsymmetrical blocked ketones.