James West
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
James West has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Valerie Rennoll
Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
4 shared publications - Cheng Huang
Johns Hopkins University, United States
2 shared publications - Helena Hahn
Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD, USA
2 shared publications - Howard E. Katz
Johns Hopkins University
2 shared publications - Ian McLane
Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, USA
2 shared publications Ilene Busch-Vishniac
McMaster University, 1280 Main Street West, Hamilton, ON L9G 4X6, Canada
2 shared publications
Latest Publications
- 1 October 2024
- Published by Springer Nature
- p. 23-31
Sensors and Devices Integrated into Telerehabilitation Interventions – A Review
- 1 October 2024
- Published by Springer Nature
- p. 23-31
Sensors and Devices Integrated into Telerehabilitation Interventions – A Review
- Open Access
- 15 November 2023
- Published by MDPI AG
- Vol. 58 (1) , 99
Wearable Impedance-Matched Noise Canceling Sensor for Voice Pickup
Communicating under extreme noise conditions remains challenging in spite of higher-order noise-canceling microphones, throat microphones, and signal processing. Both natural and human-made background ambient noise can disturb the conveyance of information because of high noise levels. Noise cancellation, which is used frequently in audio technology, has limits in noise reduction and does not guarantee clear vocal pickup in these severe situations. A contact microphone that is attached directly to the medium of interest has the potential to pick up vocal signals with reduced noise. In this study, an electrostatic transducer with an elastomer layer that is impedance-matched to the human body is used to pick up speech sounds through constant contact on the chin and cheek. By attaching the wearable device directly to the skin, the medium of air is bypassed, and airborne noise is passively canceled. Because of the acoustic impedance-matched layer, the sensor is more sensitive to low frequencies under 500 Hz, so frequency equalization was implemented to flatten the frequency response throughout the vocal range. The perceptual evaluation of speech quality (PESQ) scores of the wearable device with equalization averaged around 2.6 on a scale from –0.5 to 4.5. Speech recordings were also collected in a noise field of 85 dB, and the performance was compared to a cardioid lapel mic, a cardioid dynamic mic, and an omnidirectional condenser mic. The recordings revealed a significantly reduced presence of white noise in the contact sensor. This study provides preliminary results that show potential vocal applications for a wearable impedance-matched sensor.
- 15 November 2023
- Published by MDPI AG
- Vol. 58 (1) , 99
Open AccessWearable Impedance-Matched Noise Canceling Sensor for Voice Pickup
Communicating under extreme noise conditions remains challenging in spite of higher-order noise-canceling microphones, throat microphones, and signal processing. Both natural and human-made background ambient noise can disturb the conveyance of information because of high noise levels. Noise cancellation, which is used frequently in audio technology, has limits in noise reduction and does not guarantee clear vocal pickup in these severe situations. A contact microphone that is attached directly to the medium of interest has the potential to pick up vocal signals with reduced noise. In this study, an electrostatic transducer with an elastomer layer that is impedance-matched to the human body is used to pick up speech sounds through constant contact on the chin and cheek. By attaching the wearable device directly to the skin, the medium of air is bypassed, and airborne noise is passively canceled. Because of the acoustic impedance-matched layer, the sensor is more sensitive to low frequencies under 500 Hz, so frequency equalization was implemented to flatten the frequency response throughout the vocal range. The perceptual evaluation of speech quality (PESQ) scores of the wearable device with equalization averaged around 2.6 on a scale from –0.5 to 4.5. Speech recordings were also collected in a noise field of 85 dB, and the performance was compared to a cardioid lapel mic, a cardioid dynamic mic, and an omnidirectional condenser mic. The recordings revealed a significantly reduced presence of white noise in the contact sensor. This study provides preliminary results that show potential vocal applications for a wearable impedance-matched sensor.
- 20 July 2023
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 6 (8) , 3241-3256
Electrostatic Acoustic Sensor with an Impedance-Matched Diaphragm Characterized for Body Sound Monitoring
Acoustic sensors are able to capture more incident energy if their acoustic impedance closely matches the acoustic impedance of the medium being probed, such as skin or wood. Controlling the acoustic impedance of polymers can be achieved by selecting materials with appropriate densities and stiffnesses as well as adding ceramic nanoparticles. This study follows a statistical methodology to examine the impact of polymer type and nanoparticle addition on the fabrication of acoustic sensors with desired acoustic impedances in the range of 1-2.2 MRayls. The proposed method using a design of experiments approach measures sensors with diaphragms of varying impedances when excited with acoustic vibrations traveling through wood, gelatin, and plastic. The sensor diaphragm is subsequently optimized for body sound monitoring, and the sensor's improved body sound coherence and airborne noise rejection are evaluated on an acoustic phantom in simulated noise environments and compared to electronic stethoscopes with onboard noise cancellation. The impedance-matched sensor demonstrates high sensitivity to body sounds, low sensitivity to airborne sound, a frequency response comparable to two state-of-the-art electronic stethoscopes, and the ability to capture lung and heart sounds from a real subject. Due to its small size, use of flexible materials, and rejection of airborne noise, the sensor provides an improved solution for wearable body sound monitoring, as well as sensing from other mediums with acoustic impedances in the range of 1-2.2 MRayls, such as water and wood.
- 20 July 2023
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 6 (8) , 3241-3256
Electrostatic Acoustic Sensor with an Impedance-Matched Diaphragm Characterized for Body Sound Monitoring
Acoustic sensors are able to capture more incident energy if their acoustic impedance closely matches the acoustic impedance of the medium being probed, such as skin or wood. Controlling the acoustic impedance of polymers can be achieved by selecting materials with appropriate densities and stiffnesses as well as adding ceramic nanoparticles. This study follows a statistical methodology to examine the impact of polymer type and nanoparticle addition on the fabrication of acoustic sensors with desired acoustic impedances in the range of 1-2.2 MRayls. The proposed method using a design of experiments approach measures sensors with diaphragms of varying impedances when excited with acoustic vibrations traveling through wood, gelatin, and plastic. The sensor diaphragm is subsequently optimized for body sound monitoring, and the sensor's improved body sound coherence and airborne noise rejection are evaluated on an acoustic phantom in simulated noise environments and compared to electronic stethoscopes with onboard noise cancellation. The impedance-matched sensor demonstrates high sensitivity to body sounds, low sensitivity to airborne sound, a frequency response comparable to two state-of-the-art electronic stethoscopes, and the ability to capture lung and heart sounds from a real subject. Due to its small size, use of flexible materials, and rejection of airborne noise, the sensor provides an improved solution for wearable body sound monitoring, as well as sensing from other mediums with acoustic impedances in the range of 1-2.2 MRayls, such as water and wood.
- Open Access
Considerations and Challenges for Real-World Deployment of an Acoustic-Based COVID-19 Screening System
Coronavirus disease 2019 (COVID-19) has led to countless deaths and widespread global disruptions. Acoustic-based artificial intelligence (AI) tools could provide a simple, scalable, and prompt method to screen for COVID-19 using easily acquirable physiological sounds. These systems have been demonstrated previously and have shown promise but lack robust analysis of their deployment in real-world settings when faced with diverse recording equipment, noise environments, and test subjects. The primary aim of this work is to begin to understand the impacts of these real-world deployment challenges on the system performance. Using Mel-Frequency Cepstral Coefficients (MFCC) and RelAtive SpecTrAl-Perceptual Linear Prediction (RASTA-PLP) features extracted from cough, speech, and breathing sounds in a crowdsourced dataset, we present a baseline classification system that obtains an average receiver operating characteristic area under the curve (AUC-ROC) of 0.77 when discriminating between COVID-19 and non-COVID subjects. The classifier performance is then evaluated on four additional datasets, resulting in performance variations between 0.64 and 0.87 AUC-ROC, depending on the sound type. By analyzing subsets of the available recordings, it is noted that the system performance degrades with certain recording devices, noise contamination, and with symptom status. Furthermore, performance degrades when a uniform classification threshold from the training data is subsequently used across all datasets. However, the system performance is robust to confounding factors, such as gender, age group, and the presence of other respiratory conditions. Finally, when analyzing multiple speech recordings from the same subjects, the system achieves promising performance with an AUC-ROC of 0.78, though the classification does appear to be impacted by natural speech variations. Overall, the proposed system, and by extension other acoustic-based diagnostic aids in the literature, could provide comparable accuracy to rapid antigen testing but significant deployment challenges need to be understood and addressed prior to clinical use.
Open AccessConsiderations and Challenges for Real-World Deployment of an Acoustic-Based COVID-19 Screening System
Coronavirus disease 2019 (COVID-19) has led to countless deaths and widespread global disruptions. Acoustic-based artificial intelligence (AI) tools could provide a simple, scalable, and prompt method to screen for COVID-19 using easily acquirable physiological sounds. These systems have been demonstrated previously and have shown promise but lack robust analysis of their deployment in real-world settings when faced with diverse recording equipment, noise environments, and test subjects. The primary aim of this work is to begin to understand the impacts of these real-world deployment challenges on the system performance. Using Mel-Frequency Cepstral Coefficients (MFCC) and RelAtive SpecTrAl-Perceptual Linear Prediction (RASTA-PLP) features extracted from cough, speech, and breathing sounds in a crowdsourced dataset, we present a baseline classification system that obtains an average receiver operating characteristic area under the curve (AUC-ROC) of 0.77 when discriminating between COVID-19 and non-COVID subjects. The classifier performance is then evaluated on four additional datasets, resulting in performance variations between 0.64 and 0.87 AUC-ROC, depending on the sound type. By analyzing subsets of the available recordings, it is noted that the system performance degrades with certain recording devices, noise contamination, and with symptom status. Furthermore, performance degrades when a uniform classification threshold from the training data is subsequently used across all datasets. However, the system performance is robust to confounding factors, such as gender, age group, and the presence of other respiratory conditions. Finally, when analyzing multiple speech recordings from the same subjects, the system achieves promising performance with an AUC-ROC of 0.78, though the classification does appear to be impacted by natural speech variations. Overall, the proposed system, and by extension other acoustic-based diagnostic aids in the literature, could provide comparable accuracy to rapid antigen testing but significant deployment challenges need to be understood and addressed prior to clinical use.
- Open Access
Optimized Acoustic Phantom Design for Characterizing Body Sound Sensors
Many commercial and prototype devices are available for capturing body sounds that provide important information on the health of the lungs and heart; however, a standardized method to characterize and compare these devices is not agreed upon. Acoustic phantoms are commonly used because they generate repeatable sounds that couple to devices using a material layer that mimics the characteristics of skin. While multiple acoustic phantoms have been presented in literature, it is unclear how design elements, such as the driver type and coupling layer, impact the acoustical characteristics of the phantom and, therefore, the device being measured. Here, a design of experiments approach is used to compare the frequency responses of various phantom constructions. An acoustic phantom that uses a loudspeaker to generate sound and excite a gelatin layer supported by a grid is determined to have a flatter and more uniform frequency response than other possible designs with a sound exciter and plate support. When measured on an optimal acoustic phantom, three devices are shown to have more consistent measurements with added weight and differing positions compared to a non-optimal phantom. Overall, the statistical models developed here provide greater insight into acoustic phantom design for improved device characterization.
Open AccessOptimized Acoustic Phantom Design for Characterizing Body Sound Sensors
Many commercial and prototype devices are available for capturing body sounds that provide important information on the health of the lungs and heart; however, a standardized method to characterize and compare these devices is not agreed upon. Acoustic phantoms are commonly used because they generate repeatable sounds that couple to devices using a material layer that mimics the characteristics of skin. While multiple acoustic phantoms have been presented in literature, it is unclear how design elements, such as the driver type and coupling layer, impact the acoustical characteristics of the phantom and, therefore, the device being measured. Here, a design of experiments approach is used to compare the frequency responses of various phantom constructions. An acoustic phantom that uses a loudspeaker to generate sound and excite a gelatin layer supported by a grid is determined to have a flatter and more uniform frequency response than other possible designs with a sound exciter and plate support. When measured on an optimal acoustic phantom, three devices are shown to have more consistent measurements with added weight and differing positions compared to a non-optimal phantom. Overall, the statistical models developed here provide greater insight into acoustic phantom design for improved device characterization.
- Open Access
Soft CNT-Polymer Composites for High Pressure Sensors
Carbon–polymer composite-based pressure sensors have many attractive features, including low cost, easy integration, and facile fabrication. Previous studies on carbon–polymer composite sensors focused on very high sensitivities for low pressure ranges (10 s of kPa), which saturate quickly at higher pressures and thus are ill-suited to measure the high pressure ranges found in various applications, including those in underwater (>1 atm, 101 kPa) and industrial environments. Current sensors designed for high pressure environments are often difficult to fabricate, expensive, and, similarly to their low-pressure counterparts, have a narrow sensing range. To address these issues, this work reports the design, synthesis, characterization, and analysis of high-pressure TPU-MWCNT based composite sensors, which detect pressures from 0.5 MPa (4.9 atm) to over 10 MPa (98.7 atm). In this study, the typical approach to improve sensitivity by increasing conductive additive concentration was found to decrease sensor performance at elevated pressures. It is shown that a better approach to elevated pressure sensitivity is to increase sensor response range by decreasing the MWCNT weight percentage, which improves sensing range and resolution. Such sensors can be useful for measuring high pressures in many industrial (e.g., manipulator feedback), automotive (e.g., damping elements, bushings), and underwater (e.g., depth sensors) applications.
Open AccessSoft CNT-Polymer Composites for High Pressure Sensors
Carbon–polymer composite-based pressure sensors have many attractive features, including low cost, easy integration, and facile fabrication. Previous studies on carbon–polymer composite sensors focused on very high sensitivities for low pressure ranges (10 s of kPa), which saturate quickly at higher pressures and thus are ill-suited to measure the high pressure ranges found in various applications, including those in underwater (>1 atm, 101 kPa) and industrial environments. Current sensors designed for high pressure environments are often difficult to fabricate, expensive, and, similarly to their low-pressure counterparts, have a narrow sensing range. To address these issues, this work reports the design, synthesis, characterization, and analysis of high-pressure TPU-MWCNT based composite sensors, which detect pressures from 0.5 MPa (4.9 atm) to over 10 MPa (98.7 atm). In this study, the typical approach to improve sensitivity by increasing conductive additive concentration was found to decrease sensor performance at elevated pressures. It is shown that a better approach to elevated pressure sensitivity is to increase sensor response range by decreasing the MWCNT weight percentage, which improves sensing range and resolution. Such sensors can be useful for measuring high pressures in many industrial (e.g., manipulator feedback), automotive (e.g., damping elements, bushings), and underwater (e.g., depth sensors) applications.
- Open Access
A Micro-Machined Microphone Based on a Combination of Electret and Field-Effect Transistor
Capacitive-type transduction is now widely used in MEMS microphones. However, its sensitivity decreases with reducing size, due to decreasing air gap capacitance. In the present study, we proposed and developed the Electret Gate of Field Effect Transistor (ElGoFET) transduction based on an electret and FET (field-effect-transistor) as a novel mechanism of MEMS microphone transduction. The ElGoFET transduction has the advantage that the sensitivity is dependent on the ratio of capacitance components in the transduction structure. Hence, ElGoFET transduction has high sensitivity even with a smaller air gap capacitance, due to a miniaturization of the transducer. A FET with a floating-gate electrode embedded on a membrane was designed and fabricated and an electret was fabricated by ion implantation with Ga+ ions. During the assembly process between the FET and the electret, the operating point of the FET was characterized using the static response of the FET induced by the electric field due to the trapped positive charge at the electret. Additionally, we evaluated the microphone performance of the ElGoFET by measuring the acoustic response in air using a semi-anechoic room. The results confirmed that the proposed transduction mechanism has potential for microphone applications.
Open AccessA Micro-Machined Microphone Based on a Combination of Electret and Field-Effect Transistor
Capacitive-type transduction is now widely used in MEMS microphones. However, its sensitivity decreases with reducing size, due to decreasing air gap capacitance. In the present study, we proposed and developed the Electret Gate of Field Effect Transistor (ElGoFET) transduction based on an electret and FET (field-effect-transistor) as a novel mechanism of MEMS microphone transduction. The ElGoFET transduction has the advantage that the sensitivity is dependent on the ratio of capacitance components in the transduction structure. Hence, ElGoFET transduction has high sensitivity even with a smaller air gap capacitance, due to a miniaturization of the transducer. A FET with a floating-gate electrode embedded on a membrane was designed and fabricated and an electret was fabricated by ion implantation with Ga+ ions. During the assembly process between the FET and the electret, the operating point of the FET was characterized using the static response of the FET induced by the electric field due to the trapped positive charge at the electret. Additionally, we evaluated the microphone performance of the ElGoFET by measuring the acoustic response in air using a semi-anechoic room. The results confirmed that the proposed transduction mechanism has potential for microphone applications.
- 13 May 2014
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 135 (6) , EL291-EL297
Planar microphone based on piezoelectric electrospun poly(γ-benzyl-α,L-glutamate) nanofibers
Velocity and pressure microphones composed of piezoelectric poly(γ-benzyl-α,L-glutamate) (PBLG) nanofibers were produced by adhering a single layer of PBLG film to a Mylar diaphragm. The device exhibited a sensitivity of −60 dBV/Pa in air, and both pressure and velocity response showed a broad frequency response that was primarily controlled by the stiffness of the supporting diaphragm. The pressure microphone response was ±3 dB between 200 Hz and 4 kHz when measured in a semi-anechoic chamber. Thermal stability, easy fabrication, and simple design make this single element transducer ideal for various applications including those for underwater and high temperature use.
- 13 May 2014
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 135 (6) , EL291-EL297
Planar microphone based on piezoelectric electrospun poly(γ-benzyl-α,L-glutamate) nanofibers
Velocity and pressure microphones composed of piezoelectric poly(γ-benzyl-α,L-glutamate) (PBLG) nanofibers were produced by adhering a single layer of PBLG film to a Mylar diaphragm. The device exhibited a sensitivity of −60 dBV/Pa in air, and both pressure and velocity response showed a broad frequency response that was primarily controlled by the stiffness of the supporting diaphragm. The pressure microphone response was ±3 dB between 200 Hz and 4 kHz when measured in a semi-anechoic chamber. Thermal stability, easy fabrication, and simple design make this single element transducer ideal for various applications including those for underwater and high temperature use.
- 1 March 2010
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 127 (3_Suppleme) , 2008
Electret condenser microphones.
For more than 4 decades electretmicrophones have dominated most transducer applications in the audio frequency range for three main reasons, linearity, simplicity, and they are inexpensive. E. C. Wente invented the condensermicrophone in 1916 searching for a replacement for the carbonmicrophone used in most telephones, but it was impractical until the high‐voltage battery was replaced with a permanently charged polymer.Electretmicrophones have been the workhorse for most microphone applications including microphones for professional sound level measurements,telephones, hearing aids, professional audio recordings, games, and toys. Recent worldwide estimates of the electretmicrophone market suggest that over 2 billion units are made annually. Electretcondensermicrophones are available in a variety of sizes from very small (a few millimeters in diameter) to about 2 in. in diameter. The use of multiple microphone elements in arrays and the use of digital signal processing provide interesting prospects for improving signal‐to‐noise. A variety of microphone arrays and some important historical facts will be discussed in this talk.
- 1 March 2010
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 127 (3_Suppleme) , 2008
Electret condenser microphones.
For more than 4 decades electretmicrophones have dominated most transducer applications in the audio frequency range for three main reasons, linearity, simplicity, and they are inexpensive. E. C. Wente invented the condensermicrophone in 1916 searching for a replacement for the carbonmicrophone used in most telephones, but it was impractical until the high‐voltage battery was replaced with a permanently charged polymer.Electretmicrophones have been the workhorse for most microphone applications including microphones for professional sound level measurements,telephones, hearing aids, professional audio recordings, games, and toys. Recent worldwide estimates of the electretmicrophone market suggest that over 2 billion units are made annually. Electretcondensermicrophones are available in a variety of sizes from very small (a few millimeters in diameter) to about 2 in. in diameter. The use of multiple microphone elements in arrays and the use of digital signal processing provide interesting prospects for improving signal‐to‐noise. A variety of microphone arrays and some important historical facts will be discussed in this talk.
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 2981
Spatial Audio Reproduction Using Distributed Mode Loudspeakers
For future telecommunication systems to become more pervasive in society they must have the ability to produce high quality surround sound audio for multiple listeners. Current 5.1 audio systems lack the capacity to handle large group telecommunications because of their limited optimal listening positions ("sweet spots") and their preference for soundgenerated in front of the listeners. This is due in part to the non‐optimal position of the loudspeakers and also to the fact that very directional speakers are commonly used. Recently, a new form of speaker has been developed called a distributed mode loudspeaker (DML). These speakers use bending waves in a panel to radiate sound. Consequently, they can be very good omnidirectional sources throughout nearly all of the human hearing range. Experiments using a higher order ambisonics (HOA) approach to sound field capture and generation will be presented to show how conventional electrodynamic speaker arrays compare to equivalent DML arrays for spatial sound reproduction. This work is funded by NSF Grant IIS‐0534221.
- 1 May 2008
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 123 (5_Suppleme) , 2981
Spatial Audio Reproduction Using Distributed Mode Loudspeakers
For future telecommunication systems to become more pervasive in society they must have the ability to produce high quality surround sound audio for multiple listeners. Current 5.1 audio systems lack the capacity to handle large group telecommunications because of their limited optimal listening positions ("sweet spots") and their preference for soundgenerated in front of the listeners. This is due in part to the non‐optimal position of the loudspeakers and also to the fact that very directional speakers are commonly used. Recently, a new form of speaker has been developed called a distributed mode loudspeaker (DML). These speakers use bending waves in a panel to radiate sound. Consequently, they can be very good omnidirectional sources throughout nearly all of the human hearing range. Experiments using a higher order ambisonics (HOA) approach to sound field capture and generation will be presented to show how conventional electrodynamic speaker arrays compare to equivalent DML arrays for spatial sound reproduction. This work is funded by NSF Grant IIS‐0534221.