Murat Olgun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Murat Olgun has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Yavuz Yenginar
Civil Engineering Department, Engineering Faculty, Necmettin Erbakan University, 42090 Konya, Türkiye
8 shared publications - Alican Şenkaya
Konya Teknik Üniversitesi
4 shared publications - Ekrem Burak Toka
Konya Teknik Üniversitesi
4 shared publications - İbrahim Hakkı Erkan
Department of Civil Engineering, Konya Technical University, Konya (Turkey)
4 shared publications - Bekir Fidan
Ministry of Interior Disaster and Emergency Management Presidency (AFAD) Konya Provincial Directorate of Disaster and Emergency
2 shared publications - Esra Uray
KTO Karatay University
2 shared publications
Latest Publications
- Open Access
- 14 July 2026
- Published by Omer Halisdemir Universitesi in Ömer Halisdemir Üniversitesi Mühendislik Bilimleri Dergisi
- Vol. 17
Derin karıştırma kolonu dayanımının yanıt yüzey yöntemi esaslı modellenmesi ve karşılaştırmalı analitik ve metasezgisel optimizasyonu
Bu çalışmada, düşük plastisiteli killi zeminde oluşturulan laboratuvar ölçekli derin karıştırma kolonlarının (DKK) 28 günlük serbest basınç dayanımı (UCS), yanıt yüzey yöntemi (YYY) esaslı I-optimal yaklaşımla modellenmiş ve analitik/metasezgisel optimizasyon yöntemleriyle optimize edilmiştir. Laboratuvar ölçekli DKK’lerde çimento (%5–%20), silis dumanı (%0–%15), akışkanlaştırıcı katkı (%0–%5), su/bağlayıcı oranı (0.9–2.5) ve su muhtevası (%25–%33) etkileri 21 karışımla incelenmiştir. Karotların 28 günlük UCS değerleri 123.8–5037.7 kPa aralığında bulunmuş, varyans analizi (ANOVA) ile en etkili parametrelerin sırasıyla su/bağlayıcı oranı, çimento oranı ve silis dumanı oranı olduğu belirlenmiştir. Belirleme katsayısı (R²) = 0.945 olan regresyon modeli üzerinde Lagrange çarpanları 5089.7 kPa, parçacık sürü optimizasyonu (PSO) ve arılar algoritması ise 5154.2 kPa optimum UCS öngörmüş; optimum karışımla üretilen DKK’den alınan karotlardan ortalama 5218 kPa UCS ölçülerek tahminlerle %1.24–%2.52 aralığında uyum sağlanmıştır. Çalışma; DKK için I-optimal tasarımı, analitik/metasezgisel optimizasyonu ve laboratuvar ölçekli DKK boyutlarında doğrulamayı birleştirerek literatüre özgün bir katkı sunmaktadır.
- 14 July 2026
- Published by Omer Halisdemir Universitesi in Ömer Halisdemir Üniversitesi Mühendislik Bilimleri Dergisi
- Vol. 17
Open AccessDerin karıştırma kolonu dayanımının yanıt yüzey yöntemi esaslı modellenmesi ve karşılaştırmalı analitik ve metasezgisel optimizasyonu
Bu çalışmada, düşük plastisiteli killi zeminde oluşturulan laboratuvar ölçekli derin karıştırma kolonlarının (DKK) 28 günlük serbest basınç dayanımı (UCS), yanıt yüzey yöntemi (YYY) esaslı I-optimal yaklaşımla modellenmiş ve analitik/metasezgisel optimizasyon yöntemleriyle optimize edilmiştir. Laboratuvar ölçekli DKK’lerde çimento (%5–%20), silis dumanı (%0–%15), akışkanlaştırıcı katkı (%0–%5), su/bağlayıcı oranı (0.9–2.5) ve su muhtevası (%25–%33) etkileri 21 karışımla incelenmiştir. Karotların 28 günlük UCS değerleri 123.8–5037.7 kPa aralığında bulunmuş, varyans analizi (ANOVA) ile en etkili parametrelerin sırasıyla su/bağlayıcı oranı, çimento oranı ve silis dumanı oranı olduğu belirlenmiştir. Belirleme katsayısı (R²) = 0.945 olan regresyon modeli üzerinde Lagrange çarpanları 5089.7 kPa, parçacık sürü optimizasyonu (PSO) ve arılar algoritması ise 5154.2 kPa optimum UCS öngörmüş; optimum karışımla üretilen DKK’den alınan karotlardan ortalama 5218 kPa UCS ölçülerek tahminlerle %1.24–%2.52 aralığında uyum sağlanmıştır. Çalışma; DKK için I-optimal tasarımı, analitik/metasezgisel optimizasyonu ve laboratuvar ölçekli DKK boyutlarında doğrulamayı birleştirerek literatüre özgün bir katkı sunmaktadır.
- Open Access
- 24 June 2026
- Published by Tulpar Academic Publishing in Challenge Journal of Concrete Research Letters
- Vol. 17 (2) , 207-221
Behavior of GGBFS-modified DSM columns in clay soil: Strength–permeability characteristics and predictive laboratory modeling
This study investigated the influence of partially substituting cement with ground granulated blast furnace slag (GGBFS) on the unconfined compressive strength (UCS), splitting tensile strength (STS), and permeability coefficient (kDSM) of deep soil mixing (DSM) columns formed in clay soil. The water/binder ratio was kept constant at 1.0. Cast specimens were prepared using two binder contents, aw = 15% and 20% by dry soil mass, and five GGBFS substitution ratios of 0%, 10%, 20%, 35%, and 50%. Strength specimens were tested after 7, 28, and 56 days of curing, whereas permeability specimens were tested after 28 and 56 days. Four laboratory-scale DSM columns with a diameter of 300 mm and a length of 600 mm were formed for selected mixtures with aw = 20% and GGBFS ratios of 0%, 20%, 35%, and 50%; core samples were extracted after 28 days. UCS values ranged from 859 to 4939 kPa, STS from 182 to 830 kPa, and kDSM from 0.16×10⁻¹⁰ to 9.17×10⁻¹⁰ cm/s for cast specimens. GGBFS reduced early-age strength at 7 days, but improved strength and reduced permeability at later curing ages. The UCS and STS values of core samples were 45.26–69.79% and 63.00–77.58% of the corresponding cast specimen values, respectively, while permeability values of core samples were higher. SEM and XRD observations supported the formation of hydration and pozzolanic products.
- 24 June 2026
- Published by Tulpar Academic Publishing in Challenge Journal of Concrete Research Letters
- Vol. 17 (2) , 207-221
Open AccessBehavior of GGBFS-modified DSM columns in clay soil: Strength–permeability characteristics and predictive laboratory modeling
This study investigated the influence of partially substituting cement with ground granulated blast furnace slag (GGBFS) on the unconfined compressive strength (UCS), splitting tensile strength (STS), and permeability coefficient (kDSM) of deep soil mixing (DSM) columns formed in clay soil. The water/binder ratio was kept constant at 1.0. Cast specimens were prepared using two binder contents, aw = 15% and 20% by dry soil mass, and five GGBFS substitution ratios of 0%, 10%, 20%, 35%, and 50%. Strength specimens were tested after 7, 28, and 56 days of curing, whereas permeability specimens were tested after 28 and 56 days. Four laboratory-scale DSM columns with a diameter of 300 mm and a length of 600 mm were formed for selected mixtures with aw = 20% and GGBFS ratios of 0%, 20%, 35%, and 50%; core samples were extracted after 28 days. UCS values ranged from 859 to 4939 kPa, STS from 182 to 830 kPa, and kDSM from 0.16×10⁻¹⁰ to 9.17×10⁻¹⁰ cm/s for cast specimens. GGBFS reduced early-age strength at 7 days, but improved strength and reduced permeability at later curing ages. The UCS and STS values of core samples were 45.26–69.79% and 63.00–77.58% of the corresponding cast specimen values, respectively, while permeability values of core samples were higher. SEM and XRD observations supported the formation of hydration and pozzolanic products.
- 1 December 2024
- Published by Konya Muhendislik Bilimleri Dergisi in Konya Journal of Engineering Sciences
- Vol. 12 (4) , 865-885
A CASE STUDY: COST-BENEFIT AND RISK ANALYSES OF GABION WALL FOR ROCKFALL PROTECTION METHOD IN BOZKIR, TURKEY
The construction of residential buildings, highways, and dams in the areas under the risk of rockfall constitutes a significant threat to life and property safety. Previously, the easiest solution for rockfall protection was to move the settlements in the regions under rockfall risk to another location although it was expensive. Another method is removing the rocks by hand, machine, or using explosives, since it is dangerous. Nowadays, various rock improvement methods of constructing barriers exist due to the developing technology and facilities. In the study, to resist the rockfall, a case study on analysis of a gabion wall in the Dereköy neighborhood of Bozkır District in Konya was presented. In the preliminary design stage, mapping studies, rock kinematic analyses, and the possible rockfall scenarios in the study area were carried out to determine the current conditions of the land before the construction works. The rockfall analysis shows that the rocks on the slope will reveal energy of 400-500 kJ, and the splash heights may vary between 30-150 cm. As a result of this data, a 420m-length and 3m-height gabion wall was constructed. The gabion wall, which has a 10000-kJ energy damping capacity, eliminates the risk of rockfall for 150 houses in the region. A huge cost-benefit has been achieved by constructing a gabion wall instead of other methods (expropriation of 150 houses or the surface coating with steel mesh) as a precaution against the hazard of rockfall in the study area.
- 1 December 2024
- Published by Konya Muhendislik Bilimleri Dergisi in Konya Journal of Engineering Sciences
- Vol. 12 (4) , 865-885
A CASE STUDY: COST-BENEFIT AND RISK ANALYSES OF GABION WALL FOR ROCKFALL PROTECTION METHOD IN BOZKIR, TURKEY
The construction of residential buildings, highways, and dams in the areas under the risk of rockfall constitutes a significant threat to life and property safety. Previously, the easiest solution for rockfall protection was to move the settlements in the regions under rockfall risk to another location although it was expensive. Another method is removing the rocks by hand, machine, or using explosives, since it is dangerous. Nowadays, various rock improvement methods of constructing barriers exist due to the developing technology and facilities. In the study, to resist the rockfall, a case study on analysis of a gabion wall in the Dereköy neighborhood of Bozkır District in Konya was presented. In the preliminary design stage, mapping studies, rock kinematic analyses, and the possible rockfall scenarios in the study area were carried out to determine the current conditions of the land before the construction works. The rockfall analysis shows that the rocks on the slope will reveal energy of 400-500 kJ, and the splash heights may vary between 30-150 cm. As a result of this data, a 420m-length and 3m-height gabion wall was constructed. The gabion wall, which has a 10000-kJ energy damping capacity, eliminates the risk of rockfall for 150 houses in the region. A huge cost-benefit has been achieved by constructing a gabion wall instead of other methods (expropriation of 150 houses or the surface coating with steel mesh) as a precaution against the hazard of rockfall in the study area.
- Open Access
- 25 July 2024
- Published by Springer Nature in Bulletin of Engineering Geology and the Environment
- Vol. 83 (8) , 1
Correction to: Physical, mechanical, and microstructural characteristics of fly ash replaced cement deep mixing columns
- 25 July 2024
- Published by Springer Nature in Bulletin of Engineering Geology and the Environment
- Vol. 83 (8) , 1
Open AccessCorrection to: Physical, mechanical, and microstructural characteristics of fly ash replaced cement deep mixing columns
- Open Access
- 11 July 2024
- Published by Springer Nature in Bulletin of Engineering Geology and the Environment
- Vol. 83 (8) , 1-24
Physical, mechanical, and microstructural characteristics of fly ash replaced cement deep mixing columns
The novel approach of the study is implementing the installation procedure of fly ash (FA) replaced cement deep mixing (DM) columns to field cases aiming at managing FA waste and reducing cement utilization. FA replaced cement DM columns (diameter of 30 cm and length of 80 cm) were installed on clayey soils using a laboratory type DM machine. The effect of installation parameters such as the binder dosage, FA replacement ratio, superplasticizer content, water/binder ratio, and the liquidity index (LI) of the soil on column performance was investigated. The design of experiments and optimization process were conducted using the Taguchi method, S/N and ANOVA analyses, and the desirability function method. Observations have shown that the mixing time required for a homogeneously mixed column depends on the LI of the soil and the volume ratio (VR) of the slurry. A key parameter (LI∙VR) is defined to decide the minimum number of the mixing process. The blade rotation number should be minimum of 252 rev/m to obtain a homogeneous soil-slurry mixture. The highest strength of the column was obtained when LI of fresh soilcrete (LImix) is 1.25∙LI. Optimum installation parameters were determined as binder dosage of 425 kg/m3, FA replacement ratio is 40%, superplasticizer content is 3%, water/binder ratio is 0.8, and LI of the untreated soil is 1. In the optimum design, the mixing efficiency of the soil-slurry mixture increased and the best column performance was obtained. In addition, cement utilization and binder cost decrease 40% and 33%, respectively, in FA-replaced cement DM columns. SEM images prove the increase in column performance due to the cementation products (CSH and CAH gels) formed in the microstructure of the column.
- 11 July 2024
- Published by Springer Nature in Bulletin of Engineering Geology and the Environment
- Vol. 83 (8) , 1-24
Open AccessPhysical, mechanical, and microstructural characteristics of fly ash replaced cement deep mixing columns
The novel approach of the study is implementing the installation procedure of fly ash (FA) replaced cement deep mixing (DM) columns to field cases aiming at managing FA waste and reducing cement utilization. FA replaced cement DM columns (diameter of 30 cm and length of 80 cm) were installed on clayey soils using a laboratory type DM machine. The effect of installation parameters such as the binder dosage, FA replacement ratio, superplasticizer content, water/binder ratio, and the liquidity index (LI) of the soil on column performance was investigated. The design of experiments and optimization process were conducted using the Taguchi method, S/N and ANOVA analyses, and the desirability function method. Observations have shown that the mixing time required for a homogeneously mixed column depends on the LI of the soil and the volume ratio (VR) of the slurry. A key parameter (LI∙VR) is defined to decide the minimum number of the mixing process. The blade rotation number should be minimum of 252 rev/m to obtain a homogeneous soil-slurry mixture. The highest strength of the column was obtained when LI of fresh soilcrete (LImix) is 1.25∙LI. Optimum installation parameters were determined as binder dosage of 425 kg/m3, FA replacement ratio is 40%, superplasticizer content is 3%, water/binder ratio is 0.8, and LI of the untreated soil is 1. In the optimum design, the mixing efficiency of the soil-slurry mixture increased and the best column performance was obtained. In addition, cement utilization and binder cost decrease 40% and 33%, respectively, in FA-replaced cement DM columns. SEM images prove the increase in column performance due to the cementation products (CSH and CAH gels) formed in the microstructure of the column.
- Open Access
- 30 April 2024
- Published by Necmettin Erbakan University in Necmettin Erbakan Üniversitesi Fen ve Mühendislik Bilimleri Dergisi
- Vol. 6 (1) , 139-152
Uçucu Kül Katkısının Derin Karıştırma Kolonlarının Sıkışabilirliğine Etkisi
Sunulan bu çalışmanın özgün tarafı uçucu kül katkılı derin karıştırma kolonlarının (DKK) sıkışma kapasitesini en aza indirecek optimum enjeksiyon parametrelerini belirlemektir. Çalışmada killi bir zemin ıslak karıştırma yöntemiyle iyileştirilmiştir. Zeminin likitlik indisi, su/bağlayıcı oranı, çimento oranı, süper akışkanlaştırıcı miktarı ve uçucu kül ikame oranı gibi değişkenlerin DKK’nın sıkışabilirlik özelliğine etkisi incelenmiştir. Deneylerin tasarımı Taguchi yöntemine göre yapılmıştır. 5 parametre ve 4 seviye için L16 ortogonal dizin tablosuna göre DKK numuneleri hazırlanmıştır. Kürde bekletilen (28 ve 56 gün) numunelerin konsolidasyon deneyleri yapılarak numunenin sıkışma indisi, kabarma indisi ve boşluk oranındaki değişim belirlenmiştir. Analizler sonunda parametrelerin optimum değerleri (zeminin likitlik indisi=0.4, su/bağlayıcı oranı=0.8, bağlayıcı dozajı=425 kg/m3, süper akışkanlaştırıcı oranı=%3, uçucu kül oranı=%40) elde edilmiştir. Elde edilen sonuçlar DKK imalatında %40 oranında uçucu kül kullanılması ile enjeksiyon maliyetlerinin de bu oranda azalacağını göstermektedir. Ayrıca atık bir ürün olan uçucu kül kullanımının artması ile çevresel zararlar en aza inecektir.
- 30 April 2024
- Published by Necmettin Erbakan University in Necmettin Erbakan Üniversitesi Fen ve Mühendislik Bilimleri Dergisi
- Vol. 6 (1) , 139-152
Open AccessUçucu Kül Katkısının Derin Karıştırma Kolonlarının Sıkışabilirliğine Etkisi
Sunulan bu çalışmanın özgün tarafı uçucu kül katkılı derin karıştırma kolonlarının (DKK) sıkışma kapasitesini en aza indirecek optimum enjeksiyon parametrelerini belirlemektir. Çalışmada killi bir zemin ıslak karıştırma yöntemiyle iyileştirilmiştir. Zeminin likitlik indisi, su/bağlayıcı oranı, çimento oranı, süper akışkanlaştırıcı miktarı ve uçucu kül ikame oranı gibi değişkenlerin DKK’nın sıkışabilirlik özelliğine etkisi incelenmiştir. Deneylerin tasarımı Taguchi yöntemine göre yapılmıştır. 5 parametre ve 4 seviye için L16 ortogonal dizin tablosuna göre DKK numuneleri hazırlanmıştır. Kürde bekletilen (28 ve 56 gün) numunelerin konsolidasyon deneyleri yapılarak numunenin sıkışma indisi, kabarma indisi ve boşluk oranındaki değişim belirlenmiştir. Analizler sonunda parametrelerin optimum değerleri (zeminin likitlik indisi=0.4, su/bağlayıcı oranı=0.8, bağlayıcı dozajı=425 kg/m3, süper akışkanlaştırıcı oranı=%3, uçucu kül oranı=%40) elde edilmiştir. Elde edilen sonuçlar DKK imalatında %40 oranında uçucu kül kullanılması ile enjeksiyon maliyetlerinin de bu oranda azalacağını göstermektedir. Ayrıca atık bir ürün olan uçucu kül kullanımının artması ile çevresel zararlar en aza inecektir.
- Open Access
- 24 February 2024
- Published by Konya Muhendislik Bilimleri Dergisi in Konya Journal of Engineering Sciences
- Vol. 12 (2) , 307-325
EFFECT OF PILE GEOMETRY AND SOIL SATURATION DEGREE ON POINT BEARING CAPACITY FOR BORED PILES IN SANDS
In the present paper, an experimental study was conducted to determine the factors affecting the point bearing capacity of pile foundations constructed in dry and saturated sandy soils. Model piles were installed as reinforced concrete bored piles cast-in-situ. Model pile foundations of various geometries resting at different depths in homogeneous sand of different saturation degrees (%0-100) were loaded statically to failure. The test results showed that the bearing capacity of piles did not significantly affect by the loading rate. At most 10% difference was observed in pile bearing capacity when the loading rate was between 0.7 and 2.5 mm/min. Subsequently, the load bearing capacities of the piles were determined at a specified constant loading rate. The point and total capacities of the piles were measured separately in the experiments, then test results were compared with theoretical values. Pile point capacities provided from pile load tests are smaller than the theoretical values. The differences between experimental and theoretical results have been attributed to the Nq values. The Nq values not only dependent on the internal friction angle of the soil but also the saturation degree of the soil, the pile diameter, and the effective stress. Nq values decrease since the pile length/pile diameter ratio increases.
- 24 February 2024
- Published by Konya Muhendislik Bilimleri Dergisi in Konya Journal of Engineering Sciences
- Vol. 12 (2) , 307-325
Open AccessEFFECT OF PILE GEOMETRY AND SOIL SATURATION DEGREE ON POINT BEARING CAPACITY FOR BORED PILES IN SANDS
In the present paper, an experimental study was conducted to determine the factors affecting the point bearing capacity of pile foundations constructed in dry and saturated sandy soils. Model piles were installed as reinforced concrete bored piles cast-in-situ. Model pile foundations of various geometries resting at different depths in homogeneous sand of different saturation degrees (%0-100) were loaded statically to failure. The test results showed that the bearing capacity of piles did not significantly affect by the loading rate. At most 10% difference was observed in pile bearing capacity when the loading rate was between 0.7 and 2.5 mm/min. Subsequently, the load bearing capacities of the piles were determined at a specified constant loading rate. The point and total capacities of the piles were measured separately in the experiments, then test results were compared with theoretical values. Pile point capacities provided from pile load tests are smaller than the theoretical values. The differences between experimental and theoretical results have been attributed to the Nq values. The Nq values not only dependent on the internal friction angle of the soil but also the saturation degree of the soil, the pile diameter, and the effective stress. Nq values decrease since the pile length/pile diameter ratio increases.
- 28 March 2023
- Published by Springer Nature in Bulletin of Engineering Geology and the Environment
- Vol. 82 (4) , 1-16
Optimizing installation parameters of DM columns in clay using Taguchi method
- 28 March 2023
- Published by Springer Nature in Bulletin of Engineering Geology and the Environment
- Vol. 82 (4) , 1-16
Optimizing installation parameters of DM columns in clay using Taguchi method