Seung-Il Kim
Research Subjects
Seung-Il Kim has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Su-Min Kang
4 shared publications- Dae-Jin Kim
Department of Architectural Engineering, Kyung Hee University, Yongin, South Korea
2 shared publications - Hui-Do Kim2 shared publications
- Seung-Jae Lee2 shared publications
Tae-Sung Eom
2 shared publications- Chang Joon Lee
Department of Architectural Engineering, Chungbuk National University, Cheongju, Republic of Korea
1 shared publication
Latest Publications
- 7 November 2026
- Published by Elsevier in Structures
- Vol. 94
In-plane shear performance of new-to-existing slab interfaces with indented circular shear keys
- 7 November 2026
- Published by Elsevier in Structures
- Vol. 94
In-plane shear performance of new-to-existing slab interfaces with indented circular shear keys
- Open Access
- 23 June 2026
- Published by Elsevier in SSRN Electronic Journal
Seismic Performance of Precast Concrete Rocking Walls Post-Tensioned with Distributed 600 MPa Steel Bars
In this study, the seismic and self-centering behavior of unbonded post-tensioned precast concrete rocking walls (PT walls) under cyclic lateral loading was investigated. Unlike conventional PT walls utilizing high-strength strands concentrated near the center of the wall section, this system utilizes ordinary 600 MPa grade steel bars distributed across the wall section to improve constructability and cost-efficiency, targeting applications in low- to medium-rise buildings. Three isolated and two coupled wall specimens were tested under cyclic loading. The tests revealed that the hysteretic behavior of the isolated walls exhibited pronounced pinching and near-zero energy dissipation, marking a distinct departure from the typical self-centering behavior of conventional PT walls; despite localized concrete crushing and cover spalling at the wall toes in the early loading stages, the structural integrity remained stable up to a drift ratio of 6%, with minimal strength degradation. In contrast, the coupled wall specimens exhibited cyclic responses resembling the typical self-centering behavior. However, since damage continuously accumulated in the coupling beams from the early loading stages, subsequent post-yield strength degradation became rapid and significant, ultimately reducing the overall deformation capacity. A rocking model incorporating structural compatibility constraints was proposed to calculate the strength and deformation at the first yield and ultimate states, while accounting for the pinching observed in the post-yield cyclic behavior.
- 23 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSeismic Performance of Precast Concrete Rocking Walls Post-Tensioned with Distributed 600 MPa Steel Bars
In this study, the seismic and self-centering behavior of unbonded post-tensioned precast concrete rocking walls (PT walls) under cyclic lateral loading was investigated. Unlike conventional PT walls utilizing high-strength strands concentrated near the center of the wall section, this system utilizes ordinary 600 MPa grade steel bars distributed across the wall section to improve constructability and cost-efficiency, targeting applications in low- to medium-rise buildings. Three isolated and two coupled wall specimens were tested under cyclic loading. The tests revealed that the hysteretic behavior of the isolated walls exhibited pronounced pinching and near-zero energy dissipation, marking a distinct departure from the typical self-centering behavior of conventional PT walls; despite localized concrete crushing and cover spalling at the wall toes in the early loading stages, the structural integrity remained stable up to a drift ratio of 6%, with minimal strength degradation. In contrast, the coupled wall specimens exhibited cyclic responses resembling the typical self-centering behavior. However, since damage continuously accumulated in the coupling beams from the early loading stages, subsequent post-yield strength degradation became rapid and significant, ultimately reducing the overall deformation capacity. A rocking model incorporating structural compatibility constraints was proposed to calculate the strength and deformation at the first yield and ultimate states, while accounting for the pinching observed in the post-yield cyclic behavior.
- Open Access
- 17 June 2026
- Published by Elsevier in SSRN Electronic Journal
Cyclic testing of wall spandrels with prefabricated reinforcement details
The wall-spandrel structural system is a common lateral force-resisting system in high-rise residential buildings in Korea. In this system, ductile behavior under seismic loading can be achieved by designing the spandrels to be weaker than the connecting walls. Although proper seismic detailing is critical, reinforcement detailing for deep, narrow wall spandrels can present challenges to constructability. Thus, this study proposes prefabricated reinforcement details for wall spandrels to facilitate on-site construction and experimentally evaluates the seismic performance. Cyclic tests were performed on seven wall spandrels with prefabricated or conventional reinforcement. The results showed that the wall spandrels with the prefabricated reinforcement exhibited strength and stiffness comparable to those with conventional reinforcement. However, due to premature concrete failure and reinforcement buckling/rupture in the minimally reinforced zone, their deformation capacities decreased to drift levels of 2 ~ 3%. The cyclic curves were significantly pinched, due to the small aspect ratios of 1.33 and 1.78, leading to limited hysteretic energy dissipation. The flexural and shear strengths of the wall spandrels were compared with the nominal strengths calculated according to conventional design theory. In addition, the effective stiffness prior to yielding and the deformation capacity, obtained from the experiments, were compared with the modeling parameters of coupling beams specified in existing seismic guidelines.
- 17 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessCyclic testing of wall spandrels with prefabricated reinforcement details
The wall-spandrel structural system is a common lateral force-resisting system in high-rise residential buildings in Korea. In this system, ductile behavior under seismic loading can be achieved by designing the spandrels to be weaker than the connecting walls. Although proper seismic detailing is critical, reinforcement detailing for deep, narrow wall spandrels can present challenges to constructability. Thus, this study proposes prefabricated reinforcement details for wall spandrels to facilitate on-site construction and experimentally evaluates the seismic performance. Cyclic tests were performed on seven wall spandrels with prefabricated or conventional reinforcement. The results showed that the wall spandrels with the prefabricated reinforcement exhibited strength and stiffness comparable to those with conventional reinforcement. However, due to premature concrete failure and reinforcement buckling/rupture in the minimally reinforced zone, their deformation capacities decreased to drift levels of 2 ~ 3%. The cyclic curves were significantly pinched, due to the small aspect ratios of 1.33 and 1.78, leading to limited hysteretic energy dissipation. The flexural and shear strengths of the wall spandrels were compared with the nominal strengths calculated according to conventional design theory. In addition, the effective stiffness prior to yielding and the deformation capacity, obtained from the experiments, were compared with the modeling parameters of coupling beams specified in existing seismic guidelines.
- Open Access
- 17 April 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (4) , e0301622
Experimental and numerical investigation on the reinforced concrete boundary beam-wall system subjected to axial compression
This paper proposes a reinforced concrete (RC) boundary beam-wall system that requires less construction material and a smaller floor height compared to the conventional RC transfer girder system. The structural performance of this system subjected to axial compression was evaluated by performing a structural test on four specimens of 1/2 scale. In addition, three-dimensional nonlinear finite element analysis was also performed to verify the effectiveness of the boundary beam-wall system. Three test parameters such as the lower wall length-to-upper wall length ratio, lower wall thickness, and stirrup details of the lower wall were considered. The load-displacement curve was plotted for each specimen and its failure mode was identified. The test results showed that decrease in the lower wall length-to-upper wall length ratio significantly reduced the peak strength of the boundary beam-wall system and difference in upper and lower wall thicknesses resulted in lateral bending caused by eccentricity in the out-of-plane direction. Additionally, incorporating cross-ties and reducing stirrup spacing in the lower wall significantly improved initial stiffness and peak strength, effectively minimizing stress concentration.
- 17 April 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (4) , e0301622
Open AccessExperimental and numerical investigation on the reinforced concrete boundary beam-wall system subjected to axial compression
This paper proposes a reinforced concrete (RC) boundary beam-wall system that requires less construction material and a smaller floor height compared to the conventional RC transfer girder system. The structural performance of this system subjected to axial compression was evaluated by performing a structural test on four specimens of 1/2 scale. In addition, three-dimensional nonlinear finite element analysis was also performed to verify the effectiveness of the boundary beam-wall system. Three test parameters such as the lower wall length-to-upper wall length ratio, lower wall thickness, and stirrup details of the lower wall were considered. The load-displacement curve was plotted for each specimen and its failure mode was identified. The test results showed that decrease in the lower wall length-to-upper wall length ratio significantly reduced the peak strength of the boundary beam-wall system and difference in upper and lower wall thicknesses resulted in lateral bending caused by eccentricity in the out-of-plane direction. Additionally, incorporating cross-ties and reducing stirrup spacing in the lower wall significantly improved initial stiffness and peak strength, effectively minimizing stress concentration.
- 31 October 2022
- Published by The Korean Society of Nondestructive Testing in Journal of the Korean Society for Nondestructive Testing
- Vol. 42 (5) , 369-376
Corrosion Monitoring of a Water Supply Pipe Using a Circumferential Guided Wave Magnetostrictive Patch Transducer System
본 연구에서는 장기간 모니터링과 넓은 영역 검사에 유리하도록 고안된 원주방향 유도초음파 자기변형 패치 트랜스듀서 시스템을 용수배관에 적용하고 배관 내면의 부식이 진전됨에 따라 변하는 초음파 신호를 모니터링 하였다. 부식 변화를 관찰하기에 앞서 다양한 사전실험을 수행하여 해당 시스템의 적용 가능성을 검증하였으며 이를 통해 개발된 트랜스듀서가 배관 내부에 액체가 있어도 이에 대한 영향 없이 원주방향 전단파를 특정 축 방향 위치와 주파수에서 효과적으로 발생 및 측정할 수 있음을 확인하였다. 내면 부식을 발생시키는데 적합한 화학 용액을 선택하기 위해 용액 종류에 따라 일정 시간 부식이 진행된 용수배관 시편을 비교하는 실험을 진행한 후 모니터링 실험으로 연구를 확장하였다. 외부에 설치된 용수배관에 개발한 시스템을 설치하고 화학 용액을 주입한 상태에서 30일간 원주방향 전단파 신호 변화를 모니터링 하였으며 시간에 따라 내면 부식이 증가할수록 신호크기 또한 선형적인 감소를 확인할 수 있었다. 해당 결과를 통해 원주 경로상의 부식 정도를 모니터링하고 정밀 점검 기준을 설정하는 용도로 적용이 가능할 것으로 파악되었으며 추가적인 연구를 통해 실제 현장에서 운용되는 용수배관에 시스템을 적용하고자 한다.
- 31 October 2022
- Published by The Korean Society of Nondestructive Testing in Journal of the Korean Society for Nondestructive Testing
- Vol. 42 (5) , 369-376
Corrosion Monitoring of a Water Supply Pipe Using a Circumferential Guided Wave Magnetostrictive Patch Transducer System
본 연구에서는 장기간 모니터링과 넓은 영역 검사에 유리하도록 고안된 원주방향 유도초음파 자기변형 패치 트랜스듀서 시스템을 용수배관에 적용하고 배관 내면의 부식이 진전됨에 따라 변하는 초음파 신호를 모니터링 하였다. 부식 변화를 관찰하기에 앞서 다양한 사전실험을 수행하여 해당 시스템의 적용 가능성을 검증하였으며 이를 통해 개발된 트랜스듀서가 배관 내부에 액체가 있어도 이에 대한 영향 없이 원주방향 전단파를 특정 축 방향 위치와 주파수에서 효과적으로 발생 및 측정할 수 있음을 확인하였다. 내면 부식을 발생시키는데 적합한 화학 용액을 선택하기 위해 용액 종류에 따라 일정 시간 부식이 진행된 용수배관 시편을 비교하는 실험을 진행한 후 모니터링 실험으로 연구를 확장하였다. 외부에 설치된 용수배관에 개발한 시스템을 설치하고 화학 용액을 주입한 상태에서 30일간 원주방향 전단파 신호 변화를 모니터링 하였으며 시간에 따라 내면 부식이 증가할수록 신호크기 또한 선형적인 감소를 확인할 수 있었다. 해당 결과를 통해 원주 경로상의 부식 정도를 모니터링하고 정밀 점검 기준을 설정하는 용도로 적용이 가능할 것으로 파악되었으며 추가적인 연구를 통해 실제 현장에서 운용되는 용수배관에 시스템을 적용하고자 한다.
- 1 April 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 46
Punching shear strength improved by upward panel in reinforced concrete transfer slabs
- 1 April 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 46
Punching shear strength improved by upward panel in reinforced concrete transfer slabs
- Open Access
- 1 April 2021
- Published by Computational Structural Engineering Institute of Korea in Journal of the Computational Structural Engineering Institute of Korea
- Vol. 34 (2) , 93-100
Finite Element Analysis of the Reinforced Concrete Boundary-Beam–Wall System Subjected to Axial Load
- 1 April 2021
- Published by Computational Structural Engineering Institute of Korea in Journal of the Computational Structural Engineering Institute of Korea
- Vol. 34 (2) , 93-100
Open AccessFinite Element Analysis of the Reinforced Concrete Boundary-Beam–Wall System Subjected to Axial Load
- 25 March 2009
- Published by Wiley in The Structural Design of Tall and Special Buildings
- Vol. 19 (7) , 707-727
Composite beam composed of steel and precast concrete (modularized hybrid system). Part IV: Application for multi‐residential housing
Multi‐residential bearing wall apartments have been constructed to meet the needs of the population growth in metropolitan Korea since 1980. It is extremely difficult to remodel wall‐type multi‐residential apartments due to the nature of the bearing walls. Residents also experience noise and vibrations generated between floors. It is necessary to introduce a frame structure that enables easy remodelling for the realization of long life of apartment. This paper introduces an efficient, multi‐residential modularized hybrid system (MHS). The material quantities, material cost and amount of CO2 emission for the MHS are compared to that of bearing wall structures (linear rectangular shape and tower shape) and flat slab structures. A multi‐residential apartment with an MHS composite girder ensures architectural plan flexibility and easy remodelling, while the floor heights are maintained at the same floor height as in bearing wall structures. The material cost of MHS multi‐residential housing can be reduced by reducing the amount of concrete and reinforcement steels required for the slabs and walls. The MHS also reduces CO2 emission in accordance with the reduction of construction materials. Dry‐type construction can be environment friendly by reducing human resources, temporary materials and waste. Copyright © 2009 John Wiley & Sons, Ltd.
- 25 March 2009
- Published by Wiley in The Structural Design of Tall and Special Buildings
- Vol. 19 (7) , 707-727
Composite beam composed of steel and precast concrete (modularized hybrid system). Part IV: Application for multi‐residential housing
Multi‐residential bearing wall apartments have been constructed to meet the needs of the population growth in metropolitan Korea since 1980. It is extremely difficult to remodel wall‐type multi‐residential apartments due to the nature of the bearing walls. Residents also experience noise and vibrations generated between floors. It is necessary to introduce a frame structure that enables easy remodelling for the realization of long life of apartment. This paper introduces an efficient, multi‐residential modularized hybrid system (MHS). The material quantities, material cost and amount of CO2 emission for the MHS are compared to that of bearing wall structures (linear rectangular shape and tower shape) and flat slab structures. A multi‐residential apartment with an MHS composite girder ensures architectural plan flexibility and easy remodelling, while the floor heights are maintained at the same floor height as in bearing wall structures. The material cost of MHS multi‐residential housing can be reduced by reducing the amount of concrete and reinforcement steels required for the slabs and walls. The MHS also reduces CO2 emission in accordance with the reduction of construction materials. Dry‐type construction can be environment friendly by reducing human resources, temporary materials and waste. Copyright © 2009 John Wiley & Sons, Ltd.