Qiliang Sun
Research Subjects
Qiliang Sun has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Hongli Zhang
Key Laboratory of Evaluation and Multipurpose Utilization of Polymetallic Ores Ministry of Natural Resources, Zhengzhou 450006, China
2 shared publications - Lu Liu
Key Laboratory of Evaluation and Multipurpose Utilization of Polymetallic Ores Ministry of Natural Resources, Zhengzhou 450006, China
2 shared publications - Wenshan Ni
Zhengzhou Institute of Multipurpose Utilization of Mineral Resources, CAGS, Zhengzhou 450006, China
2 shared publications - Xiangju Mao
Zhengzhou Institute of Multipurpose Utilization of Mineral Resources, CAGS, Zhengzhou 450006, China
2 shared publications - Xiaorui Guo
Zhengzhou Institute of Multipurpose Utilization of Mineral Resources, CAGS, Zhengzhou 450006, PR China
2 shared publications - Yao Mingxing
Zhengzhou Institute of Multipurpose Utilization of Mineral Resources, CAGS, Zhengzhou 450006, China
1 shared publication
Latest Publications
- Open Access
- 5 May 2021
- Published by Wiley in International Journal of Analytical Chemistry
- Vol. 2021, 1-8
Bismuth-Remaining Cupellation Fire Assay Preconcentration Combined with Inductively Coupled Plasma Mass Spectrometry for the Simultaneous Determination of Ultratrace Au, Pt, Pd, Ru, Rh, and Ir in Geologic Samples
In this work, a novel method of bismuth fire assay (Bi-FA) combined with inductively coupled plasma mass spectrometry (ICP-MS) simultaneous determination of ultratrace gold (Au), platinum (Pt), palladium (Pd), ruthenium (Ru), rhodium (Rh), and iridium (Ir) in geologic samples was established. Bismuth oxide (Bi2O3) was used as noble metal elements fire assay collector, and Bi-remaining protection cupellation was employed to generate Bi granule. After the Bi granule was microwave-digested by aqua regia (40, v/v), 197Au, 195Pt, 106Pd, 101Ru, 103Rh, and 193Ir in the sample solution were determined by ICP-MS. Using Bi as cupellation protector, volatile Ru could be collected effectively and without volatilization loss during microwave digestion and decompression. Moreover, the toxicity of Bi was exceptionally low compared to toxic nickel oxide and lead oxide in nickel sulfide/lead fire assay; thus Bi-FA was a green environmental analysis method. The mineral composition and decomposition character of chromite, black shale, and polymetallic ore were investigated, and pretreatment procedures were optimized for such special samples. Besides, the influence of mass spectrum interference of coexisting elements was discussed. Under the optimal conditions, excellent curve fittings of Au, Pt, Pd, Ru, Rh, and Ir were obtained between 0.01 and 100ng·mL−1, with the correlation coefficients exceeding 0.9995. The detection limits were from 0.002ng·g−1 to 0.025ng·g−1. The developed method was applied to analyze the Chinese Certified Reference Materials (CRMs) and the determined values were in good agreement with the certified values.
- 5 May 2021
- Published by Wiley in International Journal of Analytical Chemistry
- Vol. 2021, 1-8
Open AccessBismuth-Remaining Cupellation Fire Assay Preconcentration Combined with Inductively Coupled Plasma Mass Spectrometry for the Simultaneous Determination of Ultratrace Au, Pt, Pd, Ru, Rh, and Ir in Geologic Samples
In this work, a novel method of bismuth fire assay (Bi-FA) combined with inductively coupled plasma mass spectrometry (ICP-MS) simultaneous determination of ultratrace gold (Au), platinum (Pt), palladium (Pd), ruthenium (Ru), rhodium (Rh), and iridium (Ir) in geologic samples was established. Bismuth oxide (Bi2O3) was used as noble metal elements fire assay collector, and Bi-remaining protection cupellation was employed to generate Bi granule. After the Bi granule was microwave-digested by aqua regia (40, v/v), 197Au, 195Pt, 106Pd, 101Ru, 103Rh, and 193Ir in the sample solution were determined by ICP-MS. Using Bi as cupellation protector, volatile Ru could be collected effectively and without volatilization loss during microwave digestion and decompression. Moreover, the toxicity of Bi was exceptionally low compared to toxic nickel oxide and lead oxide in nickel sulfide/lead fire assay; thus Bi-FA was a green environmental analysis method. The mineral composition and decomposition character of chromite, black shale, and polymetallic ore were investigated, and pretreatment procedures were optimized for such special samples. Besides, the influence of mass spectrum interference of coexisting elements was discussed. Under the optimal conditions, excellent curve fittings of Au, Pt, Pd, Ru, Rh, and Ir were obtained between 0.01 and 100ng·mL−1, with the correlation coefficients exceeding 0.9995. The detection limits were from 0.002ng·g−1 to 0.025ng·g−1. The developed method was applied to analyze the Chinese Certified Reference Materials (CRMs) and the determined values were in good agreement with the certified values.
- Open Access
- 24 March 2021
- Published by Bentham Science Publishers Ltd. in Current Analytical Chemistry
- Vol. 17 (4) , 552-563
Simultaneous Determination of Ultra-trace Pt, Pd, Rh and Ir in Geochemical Samples by Inductively Coupled Plasma Mass Spectrometry Following Tin Fire Assay Preconcentration and Microwave Digestion
Background: Platinum (Pt), palladium (Pd), rhodium (Rh) and iridium (Ir) are platinum group elements (PGEs) and also important elements of geochemistry and environmental chemistry with the similar physic-chemical properties, which have been widely used in industry and laboratory. However, due to the low abundance and inhomogeneous distribution in natural ore as well as the nugget effect, the accurate determination of PGEs has been a challenge to analytical chemistry. Methods: In this work, a novel fire assay method was reported for the determination of ultra-trace Pt, Pd, Rh and Ir in geochemical samples. Tin powder (Sn) instead of stannic oxide (SnO2) was used as a fire assay collector to reduce the melting temperature from 1250°C to 1050°C, the escape of molten material caused by high temperature was successfully avoided. Tin bead was compressed into thin slice and dissolved by HCl. For the target Pt, Pd, Rh and Ir, HCl insoluble substance such as PtSn4, PdSn4, RhSn4 and Ir3Sn7 were formed and separated from matrix by filtering. The metal compounds precipitate together with filter paper were microwave-assisted completely digested by aqua regia (50%, v/v), thence the sample solution was determined by inductively coupled plasma mass spectrometry (ICP-MS). Results: Compared with nickel oxide and lead oxide in nickel sulfide /lead fire assay, the reagent blank of tin powder were relatively low and could be directly employed in tin fire assay to collect Pt, Pd, Rh and Ir without purifying. Moreover, the harm of nickel oxide and lead oxide to the analyst and environment was avoided by using the non-toxic tin powder. The decomposition method of chromite and black shale was investigated as well as the amount of tin powder and flour, microwave digestion program for the determination of Pt, Pd, Rh and Ir were optimized. Besides, the influence of mass spectrum interference of co-existing elements was discussed and the standard mode and kinetic energy discrimination collision pool mode were compared. Under the optimal conditions, excellent curve fitting of Pt, Pd, Rh and Ir were obtained between 0.01~100 ng mL-1, with the correlation coefficients exceeding 0.9996. The detection limits were from 0.003 ng g-1 to 0.057 ng g-1. Conclusion: The developed method was applied to analyze the Chinese Certified Reference Materials and the determined values were in good agreement with the certified values.
- 24 March 2021
- Published by Bentham Science Publishers Ltd. in Current Analytical Chemistry
- Vol. 17 (4) , 552-563
Open AccessSimultaneous Determination of Ultra-trace Pt, Pd, Rh and Ir in Geochemical Samples by Inductively Coupled Plasma Mass Spectrometry Following Tin Fire Assay Preconcentration and Microwave Digestion
Background: Platinum (Pt), palladium (Pd), rhodium (Rh) and iridium (Ir) are platinum group elements (PGEs) and also important elements of geochemistry and environmental chemistry with the similar physic-chemical properties, which have been widely used in industry and laboratory. However, due to the low abundance and inhomogeneous distribution in natural ore as well as the nugget effect, the accurate determination of PGEs has been a challenge to analytical chemistry. Methods: In this work, a novel fire assay method was reported for the determination of ultra-trace Pt, Pd, Rh and Ir in geochemical samples. Tin powder (Sn) instead of stannic oxide (SnO2) was used as a fire assay collector to reduce the melting temperature from 1250°C to 1050°C, the escape of molten material caused by high temperature was successfully avoided. Tin bead was compressed into thin slice and dissolved by HCl. For the target Pt, Pd, Rh and Ir, HCl insoluble substance such as PtSn4, PdSn4, RhSn4 and Ir3Sn7 were formed and separated from matrix by filtering. The metal compounds precipitate together with filter paper were microwave-assisted completely digested by aqua regia (50%, v/v), thence the sample solution was determined by inductively coupled plasma mass spectrometry (ICP-MS). Results: Compared with nickel oxide and lead oxide in nickel sulfide /lead fire assay, the reagent blank of tin powder were relatively low and could be directly employed in tin fire assay to collect Pt, Pd, Rh and Ir without purifying. Moreover, the harm of nickel oxide and lead oxide to the analyst and environment was avoided by using the non-toxic tin powder. The decomposition method of chromite and black shale was investigated as well as the amount of tin powder and flour, microwave digestion program for the determination of Pt, Pd, Rh and Ir were optimized. Besides, the influence of mass spectrum interference of co-existing elements was discussed and the standard mode and kinetic energy discrimination collision pool mode were compared. Under the optimal conditions, excellent curve fitting of Pt, Pd, Rh and Ir were obtained between 0.01~100 ng mL-1, with the correlation coefficients exceeding 0.9996. The detection limits were from 0.003 ng g-1 to 0.057 ng g-1. Conclusion: The developed method was applied to analyze the Chinese Certified Reference Materials and the determined values were in good agreement with the certified values.