Anupam Sahu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Anupam Sahu has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Dharmendra Kumar
Department of Electronics and Communication Engineering, Guru Ghasidas Vishwavidyalaya, Bilaspur, Chhattisgarh, India
11 shared publications - Sudhanshu Verma
Department of Electronics and Communication Engineering Madan Mohan Malaviya University of Technology Gorakhpur Uttar Pradesh India
7 shared publications - Akhilesh Kumar Chaudhary
Department of Electronics and Communication Engineering Madan Mohan Malaviya University of Technology Gorakhpur Uttar Pradesh India
3 shared publications - Santosh Kumar
Centre of Excellence for Nanotechnology, Department of Electronics and Communication Engineering, Koneru Lakshmaiah Education Foundation, Vaddeswaram 522302, Andhra Pradesh, India
3 shared publications - Vijay Shanker Chaudhary
Department of Electronics and Communication Engineering, Madan Mohan Malaviya University of Technology, Gorakhpur, Uttar Pradesh, India
3 shared publications - Brijesh Kumar
Department of Information Technology, Indira Gandhi Delhi Technical University for Women, Delhi, India
2 shared publications
Latest Publications
- 2 July 2026
- Published by Wiley in Luminescence
- Vol. 41 (7) , e70560
Low‐Cost Lanthanum Nickel Manganese Oxide‐Based Photodetector With PCBM and CuI Transport Layers for Eco‐Friendly Applications
In this article, an environmentally benign lead‐free double‐perovskite photodetector with a configuration of FTO/PCBM/La 2 NiMnO 6 /CuI/carbon has been proposed. The proposed design configuration has been numerically analyzed using SCAPS‐1D to develop a high‐performance photodetector by optimizing absorber thickness, acceptor doping, defect density, and interfacial quality. LNMO (lanthanum nickel manganese oxide) acts as an absorber that exhibits a high absorption coefficient greater than 100,000 cm −1 in the visible–NIR region and possesses favorable band alignment with PCBM (phenyl‐C 61 ‐butyric acid methyl ester) and CuI (copper (I) iodide) material for efficient charge extraction with reduced recombination. It gives a peak responsivity of 0.62 A W −1 at wavelengths of 800–840 nm and a detectivity of 1.1 × 10 15 Jones under optimized parameters, 1‐μm absorber with N A ≈ 10 16 cm −3 , N t ≈ 10 14 cm −3 . The temperature and interface‐trap analyses, therefore, highlighted thermal robustness and the dominant role of interfacial recombination in limiting performance. Thus, the obtained results indicated that proposed La 2 NiMnO 6 ‐based double‐perovskite structures integrated with sustainable transport layers act as a promising low‐toxicity path toward stable and cost‐efficient photodetectors for applications in optical communication, imaging, and environmental sensing.
- 2 July 2026
- Published by Wiley in Luminescence
- Vol. 41 (7) , e70560
Low‐Cost Lanthanum Nickel Manganese Oxide‐Based Photodetector With PCBM and CuI Transport Layers for Eco‐Friendly Applications
In this article, an environmentally benign lead‐free double‐perovskite photodetector with a configuration of FTO/PCBM/La 2 NiMnO 6 /CuI/carbon has been proposed. The proposed design configuration has been numerically analyzed using SCAPS‐1D to develop a high‐performance photodetector by optimizing absorber thickness, acceptor doping, defect density, and interfacial quality. LNMO (lanthanum nickel manganese oxide) acts as an absorber that exhibits a high absorption coefficient greater than 100,000 cm −1 in the visible–NIR region and possesses favorable band alignment with PCBM (phenyl‐C 61 ‐butyric acid methyl ester) and CuI (copper (I) iodide) material for efficient charge extraction with reduced recombination. It gives a peak responsivity of 0.62 A W −1 at wavelengths of 800–840 nm and a detectivity of 1.1 × 10 15 Jones under optimized parameters, 1‐μm absorber with N A ≈ 10 16 cm −3 , N t ≈ 10 14 cm −3 . The temperature and interface‐trap analyses, therefore, highlighted thermal robustness and the dominant role of interfacial recombination in limiting performance. Thus, the obtained results indicated that proposed La 2 NiMnO 6 ‐based double‐perovskite structures integrated with sustainable transport layers act as a promising low‐toxicity path toward stable and cost‐efficient photodetectors for applications in optical communication, imaging, and environmental sensing.
- 16 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanobioscience
- Vol. 25 (3) , 332-339
Recent Advancements and Emerging Trends in Biosensors: A Review on Disease Diagnosis and Personalized Medicine
Recent research advances and developments in biosensor technology and an overview of its innovative applications for the healthcare industry are reviewed in this article. Biosensors can monitor and detect a variety of biological and chemical characteristics with accuracy and less or minimal invasiveness. It can be classified depending upon their working principle and transducing property, like electrochemical, optical, and piezoelectric processes, and are deployed for various medical applications discussed in this article. This paper provides a brief review of the novel applications of biosensors in healthcare, including illness diagnosis, medication development, and personalized medicine. Difficulties in healthcare biosensor technology as well as the future directions for research and development is highlighted. The fundamental elements of biosensors, their types—such as electrochemical, piezoelectric, thermometric, and optical—as well as current developments in the area, operating theories, and their potential applications, have been covered. This article provides a thorough understanding of the most current advancements in biosensor technology for healthcare and how they may further enhance outcomes and treatment for patients.
- 16 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanobioscience
- Vol. 25 (3) , 332-339
Recent Advancements and Emerging Trends in Biosensors: A Review on Disease Diagnosis and Personalized Medicine
Recent research advances and developments in biosensor technology and an overview of its innovative applications for the healthcare industry are reviewed in this article. Biosensors can monitor and detect a variety of biological and chemical characteristics with accuracy and less or minimal invasiveness. It can be classified depending upon their working principle and transducing property, like electrochemical, optical, and piezoelectric processes, and are deployed for various medical applications discussed in this article. This paper provides a brief review of the novel applications of biosensors in healthcare, including illness diagnosis, medication development, and personalized medicine. Difficulties in healthcare biosensor technology as well as the future directions for research and development is highlighted. The fundamental elements of biosensors, their types—such as electrochemical, piezoelectric, thermometric, and optical—as well as current developments in the area, operating theories, and their potential applications, have been covered. This article provides a thorough understanding of the most current advancements in biosensor technology for healthcare and how they may further enhance outcomes and treatment for patients.
- 28 December 2025
- Published by Wiley in Luminescence
- Vol. 40 (12) , e70389
High Performance Lead‐Free Perovskite‐Based Photodetector for Low‐Light Intensity Detection in Biomedical Applications
This work presents a comprehensive numerical study on a lead‐free, tin‐based perovskite photodetector (PPD) designed for low‐light biomedical sensing applications. Using CH 3 NH 3 SnBr 3 as the active absorber layer, we model a device architecture comprising FTO/CdZnS/CH 3 NH 3 SnBr 3 /Spiro‐OMeTAD/Au, optimizing key parameters through combined SCAPS‐1D and COMSOL Multiphysics simulations. We systematically investigate the influence of absorber thickness, defect density, donor doping, electric field distribution, series and shunt resistance, and interface properties to maximize optoelectronic performance. The optimized PPD achieves a peak responsivity of 0.55 A/W and a detectivity of 9.7 × 10 14 Jones within the red‐light spectral window (680–790 nm), demonstrating enhanced charge carrier lifetimes and effective interfacial charge extraction. These results highlight the potential of CH 3 NH 3 SnBr 3 as an eco‐friendly alternative to lead‐based perovskites, advancing the development of high‐sensitivity, low‐illumination photodetectors for biomedical imaging and diagnostics.
- 28 December 2025
- Published by Wiley in Luminescence
- Vol. 40 (12) , e70389
High Performance Lead‐Free Perovskite‐Based Photodetector for Low‐Light Intensity Detection in Biomedical Applications
This work presents a comprehensive numerical study on a lead‐free, tin‐based perovskite photodetector (PPD) designed for low‐light biomedical sensing applications. Using CH 3 NH 3 SnBr 3 as the active absorber layer, we model a device architecture comprising FTO/CdZnS/CH 3 NH 3 SnBr 3 /Spiro‐OMeTAD/Au, optimizing key parameters through combined SCAPS‐1D and COMSOL Multiphysics simulations. We systematically investigate the influence of absorber thickness, defect density, donor doping, electric field distribution, series and shunt resistance, and interface properties to maximize optoelectronic performance. The optimized PPD achieves a peak responsivity of 0.55 A/W and a detectivity of 9.7 × 10 14 Jones within the red‐light spectral window (680–790 nm), demonstrating enhanced charge carrier lifetimes and effective interfacial charge extraction. These results highlight the potential of CH 3 NH 3 SnBr 3 as an eco‐friendly alternative to lead‐based perovskites, advancing the development of high‐sensitivity, low‐illumination photodetectors for biomedical imaging and diagnostics.
- 13 June 2025
- Published by Wiley in Advanced Theory and Simulations
- Vol. 8 (10)
Performance Analysis of SPR Sensor Based on Tin Di‐selenide, Silicon and Lead Titanate for Malaria Detection
This paper introduces the design of a high‐performance Surface Plasmon Resonance (SPR) sensor using a SnSe2/Si/PbTiO3 heterostructure for detecting malaria, targeting the different stages of the plasmodium parasite lifecycle. The Tin di‐selenide (SnSe2) with high refractive index (RI) and excellent absorption property in visible and infrared regions allows efficient interaction with the evanescent field, thereby increasing sensitivity for small RI changes near the surface. The strategic integration of lead titanate (PbTiO3), known for its high RI and tunable bandgap, with SnSe2 and Silicon (Si) layers, the proposed sensor design (FK51A‐prism/Ag/SnSe2/Si/PbTiO3/Sensing‐Medium) significantly improves sensitivity to 390.41°/RIU for the ring stage of malaria. The Kretschmann configuration, in conjunction with the Transfer Matrix Method (TMM) and angular interrogation, has been utilized to optimize the performance of the proposed SPR sensor. The proposed design achieves an optimal Quality Factor (QF) of 130.92 RIU⁻¹, enabling the detection of small changes in RI. With a Detection Accuracy (DA) of 0.33 deg−1 for the ring stage, the proposed SPR sensor demonstrates its potential for early and accurate malaria diagnosis. Also, the enhanced DA and QF in later stages (trophozoite and schizont stages) offers broad detection range of the proposed SPR design. The design offers a promising application across different biomedical applications.
- 13 June 2025
- Published by Wiley in Advanced Theory and Simulations
- Vol. 8 (10)
Performance Analysis of SPR Sensor Based on Tin Di‐selenide, Silicon and Lead Titanate for Malaria Detection
This paper introduces the design of a high‐performance Surface Plasmon Resonance (SPR) sensor using a SnSe2/Si/PbTiO3 heterostructure for detecting malaria, targeting the different stages of the plasmodium parasite lifecycle. The Tin di‐selenide (SnSe2) with high refractive index (RI) and excellent absorption property in visible and infrared regions allows efficient interaction with the evanescent field, thereby increasing sensitivity for small RI changes near the surface. The strategic integration of lead titanate (PbTiO3), known for its high RI and tunable bandgap, with SnSe2 and Silicon (Si) layers, the proposed sensor design (FK51A‐prism/Ag/SnSe2/Si/PbTiO3/Sensing‐Medium) significantly improves sensitivity to 390.41°/RIU for the ring stage of malaria. The Kretschmann configuration, in conjunction with the Transfer Matrix Method (TMM) and angular interrogation, has been utilized to optimize the performance of the proposed SPR sensor. The proposed design achieves an optimal Quality Factor (QF) of 130.92 RIU⁻¹, enabling the detection of small changes in RI. With a Detection Accuracy (DA) of 0.33 deg−1 for the ring stage, the proposed SPR sensor demonstrates its potential for early and accurate malaria diagnosis. Also, the enhanced DA and QF in later stages (trophozoite and schizont stages) offers broad detection range of the proposed SPR design. The design offers a promising application across different biomedical applications.
- 29 May 2025
- Published by IOP Publishing in Journal of Optics
- Vol. 27 (6) , 065301
High-sensitivity double-D shaped photonic crystal fiber biosensor with rectangular split core for early cancer detection in various human organs
This study presents and evaluates a novel double-D-shaped photonic crystal fiber (PCF) biosensor with a rectangular split core, designed for rapid cancer diagnosis in skin, adrenal gland, cervical, blood, and breast tissues by differentiating the refractive indices of healthy and malignant cells. The cladding features five rings of air holes in circular and elliptical shapes, while the central region contains three rectangular strip air holes intended for sample analyte insertion. The sensing performance is assessed by quantifying the dip wavelength shift in the transmission spectra between cancerous and normal cells. The proposed biosensor is modeled and analyzed through simulations performed using the finite element method in COMSOL multiphysics. Mathematical analysis indicates that the biosensor achieves a maximum wavelength sensitivity of 16 571.42 nm RIU−1 for blood cancer cells. This high-sensitivity PCF biosensor offers a promising approach for early cancer detection.
- 29 May 2025
- Published by IOP Publishing in Journal of Optics
- Vol. 27 (6) , 065301
High-sensitivity double-D shaped photonic crystal fiber biosensor with rectangular split core for early cancer detection in various human organs
This study presents and evaluates a novel double-D-shaped photonic crystal fiber (PCF) biosensor with a rectangular split core, designed for rapid cancer diagnosis in skin, adrenal gland, cervical, blood, and breast tissues by differentiating the refractive indices of healthy and malignant cells. The cladding features five rings of air holes in circular and elliptical shapes, while the central region contains three rectangular strip air holes intended for sample analyte insertion. The sensing performance is assessed by quantifying the dip wavelength shift in the transmission spectra between cancerous and normal cells. The proposed biosensor is modeled and analyzed through simulations performed using the finite element method in COMSOL multiphysics. Mathematical analysis indicates that the biosensor achieves a maximum wavelength sensitivity of 16 571.42 nm RIU−1 for blood cancer cells. This high-sensitivity PCF biosensor offers a promising approach for early cancer detection.
- Top Cited Papers
- 7 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (4) , 5956-5968
Photonic Crystal Fiber-Based Sensors for Various Cancer Detection in Human Body: A Review
The development of compact, highly sensitive sensors for real-time analyte detection is crucial for medical diagnostics. The promising characteristics of photonic crystal fibers (PCFs) have captivated researchers, driving efforts to develop sensors for early cancer detection. The microscopic air holes within the PCF structure allow analytes to be inserted, enabling precise interaction between confined light and analyte for detecting malignancies. This review examines PCFs’ potential in cancer detection, focusing on principles like evanescent waves (EWs), surface plasmon resonance (SPR), surface-enhanced Raman scattering (SERS), and interferometry. SPR-based PCF sensors stand out for their design flexibility and optical properties, showing great promise for cancer detection and potential clinical applications. This review also emphasizes recent developments in PCF-SPR sensors, addressing their performance and possible improvements.
- 7 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (4) , 5956-5968
Top Cited PapersPhotonic Crystal Fiber-Based Sensors for Various Cancer Detection in Human Body: A Review
The development of compact, highly sensitive sensors for real-time analyte detection is crucial for medical diagnostics. The promising characteristics of photonic crystal fibers (PCFs) have captivated researchers, driving efforts to develop sensors for early cancer detection. The microscopic air holes within the PCF structure allow analytes to be inserted, enabling precise interaction between confined light and analyte for detecting malignancies. This review examines PCFs’ potential in cancer detection, focusing on principles like evanescent waves (EWs), surface plasmon resonance (SPR), surface-enhanced Raman scattering (SERS), and interferometry. SPR-based PCF sensors stand out for their design flexibility and optical properties, showing great promise for cancer detection and potential clinical applications. This review also emphasizes recent developments in PCF-SPR sensors, addressing their performance and possible improvements.
- 3 November 2024
- Published by Wiley in Physica Status Solidi (b)
- Vol. 262 (3)
Enhancement in Photodetector Sensitivity Using All‐Inorganic Perovskite Absorber RbGeI3 and Copper Bismuth Thiocyanate for Superior Charge Transport
This study investigates a photodetector design using the nontoxic, all‐inorganic perovskite material RbGeI3, which is distinguished by its efficient light absorption and excellent photoelectric conversion properties. Incorporating copper bismuth thiocyanate (CBTS) and indium gallium zinc oxide layers, this design enhances charge transport, leading to a photodetector that exhibits exceptional sensitivity across the visible spectrum, along with a peak responsivity of 0.63 A W−1 and a detectivity of 1.37 × 1013 Jones in the near‐infrared (NIR) at 900 nm. The proposed photodetector exhibits wide‐spectrum detection, encompassing both the visible range and the NIR region. These results position RbGeI3 and CBTS as compelling alternatives to traditional photodetector materials such as Si‐Ge, InGaAs, ZnO, and GaN. Validation is achieved through simulations using the SCAPS‐1D simulator, underscoring the potential of perovskite materials for advanced photodetector applications.
- 3 November 2024
- Published by Wiley in Physica Status Solidi (b)
- Vol. 262 (3)
Enhancement in Photodetector Sensitivity Using All‐Inorganic Perovskite Absorber RbGeI3 and Copper Bismuth Thiocyanate for Superior Charge Transport
This study investigates a photodetector design using the nontoxic, all‐inorganic perovskite material RbGeI3, which is distinguished by its efficient light absorption and excellent photoelectric conversion properties. Incorporating copper bismuth thiocyanate (CBTS) and indium gallium zinc oxide layers, this design enhances charge transport, leading to a photodetector that exhibits exceptional sensitivity across the visible spectrum, along with a peak responsivity of 0.63 A W−1 and a detectivity of 1.37 × 1013 Jones in the near‐infrared (NIR) at 900 nm. The proposed photodetector exhibits wide‐spectrum detection, encompassing both the visible range and the NIR region. These results position RbGeI3 and CBTS as compelling alternatives to traditional photodetector materials such as Si‐Ge, InGaAs, ZnO, and GaN. Validation is achieved through simulations using the SCAPS‐1D simulator, underscoring the potential of perovskite materials for advanced photodetector applications.