Sudhanshu Verma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sudhanshu Verma has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Akhilesh Kumar Chaudhary
Department of Electronics and Communication Engineering Madan Mohan Malaviya University of Technology Gorakhpur Uttar Pradesh India
9 shared publications - Anupam Sahu
Madan Mohan Malaviya University of Technology
7 shared publications - Pallavi Pandey
Department of Electronics and Communication Engineering Madan Mohan Malaviya University of Technology Gorakhpur Uttar Pradesh India
3 shared publications - Rajeev Kumar Chauhan
Madan Mohan Malaviya University of Technology
3 shared publications - Richa Srivastava
Department of Electronics and Communication Engineering Madan Mohan Malaviya University of Technology Gorakhpur Uttar Pradesh India
3 shared publications - Santosh Kumar
Centre of Excellence for Nanotechnology, Department of Electronics and Communication Engineering, Koneru Lakshmaiah Education Foundation, Vaddeswaram 522302, Andhra Pradesh, India
3 shared publications
Latest Publications
- 30 September 2026
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 40 (29)
Lead-free CH 3 NH 3 SnBr 3 photodetector with low dark current enabling sensitive low-intensity light detection
This study presents a numerical simulation of the performance of perovskite-based photodetectors (PDs) with the tin-based absorptive material CH 3 NH 3 SnBr 3 , using SCAPS-1D. A device was designed on the architecture, using fluorine-doped tin oxide (FTO) as the front contact, PCBM as the electron transport layer (ETL), P3HT as the hole transport layer (HTL), and gold as the back contact. The parameters that affect key performance, such as responsivity, detectivity, dark current, quantum efficiency, thermal stability, and absorber thickness, were analyzed. The performance of the CH 3 NH 3 SnBr 3 -based PD was found to be very high, with a maximum responsivity of [Formula: see text]0.46[Formula: see text]A/W at 650[Formula: see text]nm, detectivity of [Formula: see text] Jones, and quantum efficiency of up to 90%, with a wide spectral range (400–800[Formula: see text]nm). It also showed high thermal stability and uniform open-circuit voltage ([Formula: see text]) and short-circuit current density ([Formula: see text]) over a temperature range of 250 K to 450[Formula: see text]K. This high performance of CH 3 NH 3 SnBr 3 is observed due to the optimized energy band alignment and the greater built-in electric field, which improves carrier separation and decreases recombination losses. The findings identify CH 3 NH 3 SnBr 3 as a very promising perovskite-based detector technology on a scalable high-performance platform applicable in optical sensing and environmental conditions.
- 30 September 2026
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 40 (29)
Lead-free CH 3 NH 3 SnBr 3 photodetector with low dark current enabling sensitive low-intensity light detection
This study presents a numerical simulation of the performance of perovskite-based photodetectors (PDs) with the tin-based absorptive material CH 3 NH 3 SnBr 3 , using SCAPS-1D. A device was designed on the architecture, using fluorine-doped tin oxide (FTO) as the front contact, PCBM as the electron transport layer (ETL), P3HT as the hole transport layer (HTL), and gold as the back contact. The parameters that affect key performance, such as responsivity, detectivity, dark current, quantum efficiency, thermal stability, and absorber thickness, were analyzed. The performance of the CH 3 NH 3 SnBr 3 -based PD was found to be very high, with a maximum responsivity of [Formula: see text]0.46[Formula: see text]A/W at 650[Formula: see text]nm, detectivity of [Formula: see text] Jones, and quantum efficiency of up to 90%, with a wide spectral range (400–800[Formula: see text]nm). It also showed high thermal stability and uniform open-circuit voltage ([Formula: see text]) and short-circuit current density ([Formula: see text]) over a temperature range of 250 K to 450[Formula: see text]K. This high performance of CH 3 NH 3 SnBr 3 is observed due to the optimized energy band alignment and the greater built-in electric field, which improves carrier separation and decreases recombination losses. The findings identify CH 3 NH 3 SnBr 3 as a very promising perovskite-based detector technology on a scalable high-performance platform applicable in optical sensing and environmental conditions.
- 2 July 2026
- Published by Wiley in Luminescence
- Vol. 41 (7) , e70560
Low‐Cost Lanthanum Nickel Manganese Oxide‐Based Photodetector With PCBM and CuI Transport Layers for Eco‐Friendly Applications
In this article, an environmentally benign lead‐free double‐perovskite photodetector with a configuration of FTO/PCBM/La 2 NiMnO 6 /CuI/carbon has been proposed. The proposed design configuration has been numerically analyzed using SCAPS‐1D to develop a high‐performance photodetector by optimizing absorber thickness, acceptor doping, defect density, and interfacial quality. LNMO (lanthanum nickel manganese oxide) acts as an absorber that exhibits a high absorption coefficient greater than 100,000 cm −1 in the visible–NIR region and possesses favorable band alignment with PCBM (phenyl‐C 61 ‐butyric acid methyl ester) and CuI (copper (I) iodide) material for efficient charge extraction with reduced recombination. It gives a peak responsivity of 0.62 A W −1 at wavelengths of 800–840 nm and a detectivity of 1.1 × 10 15 Jones under optimized parameters, 1‐μm absorber with N A ≈ 10 16 cm −3 , N t ≈ 10 14 cm −3 . The temperature and interface‐trap analyses, therefore, highlighted thermal robustness and the dominant role of interfacial recombination in limiting performance. Thus, the obtained results indicated that proposed La 2 NiMnO 6 ‐based double‐perovskite structures integrated with sustainable transport layers act as a promising low‐toxicity path toward stable and cost‐efficient photodetectors for applications in optical communication, imaging, and environmental sensing.
- 2 July 2026
- Published by Wiley in Luminescence
- Vol. 41 (7) , e70560
Low‐Cost Lanthanum Nickel Manganese Oxide‐Based Photodetector With PCBM and CuI Transport Layers for Eco‐Friendly Applications
In this article, an environmentally benign lead‐free double‐perovskite photodetector with a configuration of FTO/PCBM/La 2 NiMnO 6 /CuI/carbon has been proposed. The proposed design configuration has been numerically analyzed using SCAPS‐1D to develop a high‐performance photodetector by optimizing absorber thickness, acceptor doping, defect density, and interfacial quality. LNMO (lanthanum nickel manganese oxide) acts as an absorber that exhibits a high absorption coefficient greater than 100,000 cm −1 in the visible–NIR region and possesses favorable band alignment with PCBM (phenyl‐C 61 ‐butyric acid methyl ester) and CuI (copper (I) iodide) material for efficient charge extraction with reduced recombination. It gives a peak responsivity of 0.62 A W −1 at wavelengths of 800–840 nm and a detectivity of 1.1 × 10 15 Jones under optimized parameters, 1‐μm absorber with N A ≈ 10 16 cm −3 , N t ≈ 10 14 cm −3 . The temperature and interface‐trap analyses, therefore, highlighted thermal robustness and the dominant role of interfacial recombination in limiting performance. Thus, the obtained results indicated that proposed La 2 NiMnO 6 ‐based double‐perovskite structures integrated with sustainable transport layers act as a promising low‐toxicity path toward stable and cost‐efficient photodetectors for applications in optical communication, imaging, and environmental sensing.
- 28 December 2025
- Published by Wiley in Luminescence
- Vol. 40 (12) , e70389
High Performance Lead‐Free Perovskite‐Based Photodetector for Low‐Light Intensity Detection in Biomedical Applications
This work presents a comprehensive numerical study on a lead‐free, tin‐based perovskite photodetector (PPD) designed for low‐light biomedical sensing applications. Using CH 3 NH 3 SnBr 3 as the active absorber layer, we model a device architecture comprising FTO/CdZnS/CH 3 NH 3 SnBr 3 /Spiro‐OMeTAD/Au, optimizing key parameters through combined SCAPS‐1D and COMSOL Multiphysics simulations. We systematically investigate the influence of absorber thickness, defect density, donor doping, electric field distribution, series and shunt resistance, and interface properties to maximize optoelectronic performance. The optimized PPD achieves a peak responsivity of 0.55 A/W and a detectivity of 9.7 × 10 14 Jones within the red‐light spectral window (680–790 nm), demonstrating enhanced charge carrier lifetimes and effective interfacial charge extraction. These results highlight the potential of CH 3 NH 3 SnBr 3 as an eco‐friendly alternative to lead‐based perovskites, advancing the development of high‐sensitivity, low‐illumination photodetectors for biomedical imaging and diagnostics.
- 28 December 2025
- Published by Wiley in Luminescence
- Vol. 40 (12) , e70389
High Performance Lead‐Free Perovskite‐Based Photodetector for Low‐Light Intensity Detection in Biomedical Applications
This work presents a comprehensive numerical study on a lead‐free, tin‐based perovskite photodetector (PPD) designed for low‐light biomedical sensing applications. Using CH 3 NH 3 SnBr 3 as the active absorber layer, we model a device architecture comprising FTO/CdZnS/CH 3 NH 3 SnBr 3 /Spiro‐OMeTAD/Au, optimizing key parameters through combined SCAPS‐1D and COMSOL Multiphysics simulations. We systematically investigate the influence of absorber thickness, defect density, donor doping, electric field distribution, series and shunt resistance, and interface properties to maximize optoelectronic performance. The optimized PPD achieves a peak responsivity of 0.55 A/W and a detectivity of 9.7 × 10 14 Jones within the red‐light spectral window (680–790 nm), demonstrating enhanced charge carrier lifetimes and effective interfacial charge extraction. These results highlight the potential of CH 3 NH 3 SnBr 3 as an eco‐friendly alternative to lead‐based perovskites, advancing the development of high‐sensitivity, low‐illumination photodetectors for biomedical imaging and diagnostics.
- 13 June 2025
- Published by Wiley in Advanced Theory and Simulations
- Vol. 8 (10)
Performance Analysis of SPR Sensor Based on Tin Di‐selenide, Silicon and Lead Titanate for Malaria Detection
This paper introduces the design of a high‐performance Surface Plasmon Resonance (SPR) sensor using a SnSe2/Si/PbTiO3 heterostructure for detecting malaria, targeting the different stages of the plasmodium parasite lifecycle. The Tin di‐selenide (SnSe2) with high refractive index (RI) and excellent absorption property in visible and infrared regions allows efficient interaction with the evanescent field, thereby increasing sensitivity for small RI changes near the surface. The strategic integration of lead titanate (PbTiO3), known for its high RI and tunable bandgap, with SnSe2 and Silicon (Si) layers, the proposed sensor design (FK51A‐prism/Ag/SnSe2/Si/PbTiO3/Sensing‐Medium) significantly improves sensitivity to 390.41°/RIU for the ring stage of malaria. The Kretschmann configuration, in conjunction with the Transfer Matrix Method (TMM) and angular interrogation, has been utilized to optimize the performance of the proposed SPR sensor. The proposed design achieves an optimal Quality Factor (QF) of 130.92 RIU⁻¹, enabling the detection of small changes in RI. With a Detection Accuracy (DA) of 0.33 deg−1 for the ring stage, the proposed SPR sensor demonstrates its potential for early and accurate malaria diagnosis. Also, the enhanced DA and QF in later stages (trophozoite and schizont stages) offers broad detection range of the proposed SPR design. The design offers a promising application across different biomedical applications.
- 13 June 2025
- Published by Wiley in Advanced Theory and Simulations
- Vol. 8 (10)
Performance Analysis of SPR Sensor Based on Tin Di‐selenide, Silicon and Lead Titanate for Malaria Detection
This paper introduces the design of a high‐performance Surface Plasmon Resonance (SPR) sensor using a SnSe2/Si/PbTiO3 heterostructure for detecting malaria, targeting the different stages of the plasmodium parasite lifecycle. The Tin di‐selenide (SnSe2) with high refractive index (RI) and excellent absorption property in visible and infrared regions allows efficient interaction with the evanescent field, thereby increasing sensitivity for small RI changes near the surface. The strategic integration of lead titanate (PbTiO3), known for its high RI and tunable bandgap, with SnSe2 and Silicon (Si) layers, the proposed sensor design (FK51A‐prism/Ag/SnSe2/Si/PbTiO3/Sensing‐Medium) significantly improves sensitivity to 390.41°/RIU for the ring stage of malaria. The Kretschmann configuration, in conjunction with the Transfer Matrix Method (TMM) and angular interrogation, has been utilized to optimize the performance of the proposed SPR sensor. The proposed design achieves an optimal Quality Factor (QF) of 130.92 RIU⁻¹, enabling the detection of small changes in RI. With a Detection Accuracy (DA) of 0.33 deg−1 for the ring stage, the proposed SPR sensor demonstrates its potential for early and accurate malaria diagnosis. Also, the enhanced DA and QF in later stages (trophozoite and schizont stages) offers broad detection range of the proposed SPR design. The design offers a promising application across different biomedical applications.
- 31 May 2025
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 54 (8) , 6903-6911
Two-Port Frequency Tunable Graphene–Silicon Built Array Antenna in THz Regime with High Gain and Pattern Diversity Features
- 31 May 2025
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 54 (8) , 6903-6911
Two-Port Frequency Tunable Graphene–Silicon Built Array Antenna in THz Regime with High Gain and Pattern Diversity Features
- 22 April 2025
- Published by Springer Nature in Plasmonics
- Vol. 20 (8) , 6623-6639
Design and Analysis of Surface Plasmon Resonance Sensor Utilizing Silver, Nickel, and Black Phosphorous for Various Cancer Detection
- 22 April 2025
- Published by Springer Nature in Plasmonics
- Vol. 20 (8) , 6623-6639
Design and Analysis of Surface Plasmon Resonance Sensor Utilizing Silver, Nickel, and Black Phosphorous for Various Cancer Detection
- Top Cited Papers
- 12 February 2025
- Published by Springer Nature in Plasmonics
- p. 1-8
Sensitivity Enhancement of SPR Sensor with Si/Perovskite heterostructure for Early Detection of Malaria
- 12 February 2025
- Published by Springer Nature in Plasmonics
- p. 1-8
Top Cited PapersSensitivity Enhancement of SPR Sensor with Si/Perovskite heterostructure for Early Detection of Malaria