Mun-Seog Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mun-Seog Kim has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Hehree Cho
Korea Research Institute of Standards and Science, 267 Gajeong-ro, Yuseong-gu, Daejeon 34113, Rep. of Korea
4 shared publications - Dong-Hun Chae
Korea Research Institute of Standards and Science (KRISS), Daejeon 34113, Republic of Korea
3 shared publications - Nobu-Hisa Kaneko
Global Research and Development Center for Business by Quantum-AI Technology (G-QuAT), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
2 shared publications - Seung-Nam Park
Korea Research Institute of Standards and Science (KRISS)
2 shared publications - Stephane Solve
BIPM, Svres Cedex, France
2 shared publications - Takehiko Oe
National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Tsukuba, Japan
2 shared publications
Latest Publications
- Open Access
- 24 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-7
Effect of Sampler Characteristics in Differential Sampling Adopting a Programmable Josephson Voltage Standard
We investigated the impact of measurement circuit configuration, sampler gain error, sampling trigger delay setting, and the built-in filter of the sampler on the accuracy of quantumbased differential sampling. In addition, we evaluated through numerical simulations how the filter function for NI PXI-5922, which changes with sampling rate, is reflected in differential sampling. We found that the filter introduces ripples throughout the differential signal, resulting in a measurement error proportional to frequency. At 3.125 kHz, the maximum difference among the RMS amplitude values obtained with different sampling rates was approximately 2 μV/V. Finally, we performed differential sampling on 1 V AC waveforms using NI PXI-5922 and Fluke 8588A, with bandwidths set to 3 MHz or higher. We found that the RMS amplitude values obtained by the two different samplers agreed within ±52 nV in the frequency range below 1.25 kHz.
- 24 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-7
Open AccessEffect of Sampler Characteristics in Differential Sampling Adopting a Programmable Josephson Voltage Standard
We investigated the impact of measurement circuit configuration, sampler gain error, sampling trigger delay setting, and the built-in filter of the sampler on the accuracy of quantumbased differential sampling. In addition, we evaluated through numerical simulations how the filter function for NI PXI-5922, which changes with sampling rate, is reflected in differential sampling. We found that the filter introduces ripples throughout the differential signal, resulting in a measurement error proportional to frequency. At 3.125 kHz, the maximum difference among the RMS amplitude values obtained with different sampling rates was approximately 2 μV/V. Finally, we performed differential sampling on 1 V AC waveforms using NI PXI-5922 and Fluke 8588A, with bandwidths set to 3 MHz or higher. We found that the RMS amplitude values obtained by the two different samplers agreed within ±52 nV in the frequency range below 1.25 kHz.
- 14 November 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (6) , 065011
Series connection of quantum Hall resistance array and programmable Josephson voltage standard for current generation at one microampere
An accurate current can be realized by a series connection of an invariant voltage and resistance with zero interconnection resistance in the framework of Ohm’s law. In practice, however, accurate current realization is limited by the temporal drift and instability of employed resistors, solid-state voltage sources and interconnection wires against environmental fluctuations, such as temperature or atmospheric pressure. Here, we generated a current of 1 μA, determined by the Josephson voltage and quantized Hall resistance array (QHRA). A programmable Josephson voltage standard (PJVS), 1 MΩ QHRA and ultrastable low noise current amplifier (ULCA) are connected in series to generate and measure a current of 1 μA. The expected current is calculated as the ratio of the Josephson voltage to the QHRA plus the output resistance of the PJVS. The relative difference between the current measured by the ULCA and the calculated current is as small as 40 nA A−1 with a combined measurement uncertainty (k = 1) of 0.13 μA A−1.
- 14 November 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (6) , 065011
Series connection of quantum Hall resistance array and programmable Josephson voltage standard for current generation at one microampere
An accurate current can be realized by a series connection of an invariant voltage and resistance with zero interconnection resistance in the framework of Ohm’s law. In practice, however, accurate current realization is limited by the temporal drift and instability of employed resistors, solid-state voltage sources and interconnection wires against environmental fluctuations, such as temperature or atmospheric pressure. Here, we generated a current of 1 μA, determined by the Josephson voltage and quantized Hall resistance array (QHRA). A programmable Josephson voltage standard (PJVS), 1 MΩ QHRA and ultrastable low noise current amplifier (ULCA) are connected in series to generate and measure a current of 1 μA. The expected current is calculated as the ratio of the Josephson voltage to the QHRA plus the output resistance of the PJVS. The relative difference between the current measured by the ULCA and the calculated current is as small as 40 nA A−1 with a combined measurement uncertainty (k = 1) of 0.13 μA A−1.
- 7 January 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (1) , 015006
Differential sampling of AC waveforms based on a programmable Josephson voltage standard using a high-precision sampler
A high-precision sampler, Fluke 8588A multimeter in the sampling mode, was utilised to perform differential sampling of AC waveforms with a programmable Josephson voltage standard. The systematic error on the differential sampling, induced by the inherent voltage-response characteristics and built-in low-pass filter of the sampler, was estimated. Experimental results and numerical simulations revealed that the sampler could be used for reliable differential sampling of AC waveforms at frequencies up to several kilohertz, with an appropriate number of the voltage steps per the waveform period, when the input bandwidth was set to 3 MHz. In addition, the sampler was compared to an integrating sampler, Keysight 3458A, now widely used for differential sampling. At 62.5 Hz, a key frequency in the future on-site key comparison of the differential sampling on AC voltage, the difference in root mean square (RMS) amplitudes obtained by the differential sampling using the two different samplers is approximately 150 nV V−1 due to the systematic error caused by the limited bandwidth of 150 kHz for the integrating sampler.
- 7 January 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (1) , 015006
Differential sampling of AC waveforms based on a programmable Josephson voltage standard using a high-precision sampler
A high-precision sampler, Fluke 8588A multimeter in the sampling mode, was utilised to perform differential sampling of AC waveforms with a programmable Josephson voltage standard. The systematic error on the differential sampling, induced by the inherent voltage-response characteristics and built-in low-pass filter of the sampler, was estimated. Experimental results and numerical simulations revealed that the sampler could be used for reliable differential sampling of AC waveforms at frequencies up to several kilohertz, with an appropriate number of the voltage steps per the waveform period, when the input bandwidth was set to 3 MHz. In addition, the sampler was compared to an integrating sampler, Keysight 3458A, now widely used for differential sampling. At 62.5 Hz, a key frequency in the future on-site key comparison of the differential sampling on AC voltage, the difference in root mean square (RMS) amplitudes obtained by the differential sampling using the two different samplers is approximately 150 nV V−1 due to the systematic error caused by the limited bandwidth of 150 kHz for the integrating sampler.
- 31 March 2021
- Published by Korean Physical Society in Physics and High Technology
- Vol. 30 (3) , 17-25
Quantum Metrology of Electrical Quantities and Mass
- 31 March 2021
- Published by Korean Physical Society in Physics and High Technology
- Vol. 30 (3) , 17-25
Quantum Metrology of Electrical Quantities and Mass
- Open Access
- 28 October 2020
- Published by IOP Publishing in Metrologia
- Vol. 57 (6) , 065025
Precision measurement of single-electron current with quantized Hall array resistance and Josephson voltage
A single electron pump was incorporated with a quantum Hall resistance and a Josephson voltage for the current evaluation in the framework of Ohm’s law. The pump current of about 60 pA level was amplified by a stable amplifier with a gain of 103 to induce a Hall voltage of about 60 mV level across a 1 MΩ Hall resistance array, which was compared with the Josephson voltage. The gain of the current amplifier was calibrated with a cryogenic current comparator bridge. For two different drive frequencies and repeated thermal cycles, the comparisons demonstrated that the pump current averaged over the first plateau was equal to ef within the combined uncertainty level of 0.3 × 10−6 (k = 1).
- 28 October 2020
- Published by IOP Publishing in Metrologia
- Vol. 57 (6) , 065025
Open AccessPrecision measurement of single-electron current with quantized Hall array resistance and Josephson voltage
A single electron pump was incorporated with a quantum Hall resistance and a Josephson voltage for the current evaluation in the framework of Ohm’s law. The pump current of about 60 pA level was amplified by a stable amplifier with a gain of 103 to induce a Hall voltage of about 60 mV level across a 1 MΩ Hall resistance array, which was compared with the Josephson voltage. The gain of the current amplifier was calibrated with a cryogenic current comparator bridge. For two different drive frequencies and repeated thermal cycles, the comparisons demonstrated that the pump current averaged over the first plateau was equal to ef within the combined uncertainty level of 0.3 × 10−6 (k = 1).
- 27 October 2020
- Published by IOP Publishing in Metrologia
- Vol. 57 (6) , 065020
Measurement configurations for differential sampling of AC waveforms based on a programmable Josephson voltage standard: effects of sampler bandwidth on the measurements
A measurement setup for differential sampling of AC waveforms based on a programmable Josephson voltage standard, with an integrating sampler, Keysight 3458, and a Δ-Σ analogue-to-digital converter, NI PXI-5922, is described. The system operates in several circuit configurations with different synchronization and triggering schemes. In particular, the focus is on how the filters implemented in the samplers affect sampling measurements. Numerical simulations on the frequency response characteristics of low-pass and finite impulse response filters for the samplers in differential sampling were performed, and the RMS amplitude of the fundamental for waveforms generated from an AC source in a voltage range of 1 V ≤ V ≤ 7.07 V and a frequency range of 40 Hz ≤ f ≤ 1.02 kHz was measured. The RMS amplitudes measured with the different samplers coincided within a few parts in 10 7 at frequencies below 100 Hz. However, the difference between the amplitudes increased with frequency, mainly due to the dramatic change of the value obtained with the integrating sampler. The difference reached up to −27 µV/V at 1.02 kHz. This feature is inferred to originate from the difference in the bandwidths for the two samplers. The stability of output waveforms for an AC source, APx-555, which could serve as a transfer standard in the framework of an on-site comparison of two independent differential sampling setups, is evaluated.
- 27 October 2020
- Published by IOP Publishing in Metrologia
- Vol. 57 (6) , 065020
Measurement configurations for differential sampling of AC waveforms based on a programmable Josephson voltage standard: effects of sampler bandwidth on the measurements
A measurement setup for differential sampling of AC waveforms based on a programmable Josephson voltage standard, with an integrating sampler, Keysight 3458, and a Δ-Σ analogue-to-digital converter, NI PXI-5922, is described. The system operates in several circuit configurations with different synchronization and triggering schemes. In particular, the focus is on how the filters implemented in the samplers affect sampling measurements. Numerical simulations on the frequency response characteristics of low-pass and finite impulse response filters for the samplers in differential sampling were performed, and the RMS amplitude of the fundamental for waveforms generated from an AC source in a voltage range of 1 V ≤ V ≤ 7.07 V and a frequency range of 40 Hz ≤ f ≤ 1.02 kHz was measured. The RMS amplitudes measured with the different samplers coincided within a few parts in 10 7 at frequencies below 100 Hz. However, the difference between the amplitudes increased with frequency, mainly due to the dramatic change of the value obtained with the integrating sampler. The difference reached up to −27 µV/V at 1.02 kHz. This feature is inferred to originate from the difference in the bandwidths for the two samplers. The stability of output waveforms for an AC source, APx-555, which could serve as a transfer standard in the framework of an on-site comparison of two independent differential sampling setups, is evaluated.
- 12 October 2020
- Published by IOP Publishing in Metrologia
- Vol. 57 (6) , 065007
Long-term drift analysis of Zener voltage standards and proposal of an initial calibration interval using calibration records accumulated for 15 years
In electrical metrology, voltage is a key quantity together with resistance for realising all electric standards in the low-frequency range. Zener voltage standards are accepted as the most stable to disseminate voltage references traceable to the Josephson standard devices. We study the long-term drift of the Zener devices to propose their initial calibration interval (CI), statistically analysing the calibration records accumulated for 15 years at the Korea Research Institute of Standards and Science (KRISS). First, we apply the direct method where the measurement reliability is obtained by integrating the probability density functions acquired from kernel density estimation (KDE). Markov chain Monte Carlo (MCMC) has been successfully demonstrated to determine the parameters of the Weibull reliability model. A numerical experiment was performed to confirm that the MCMC method works properly and is able to replace the S3 method of NCSLI. The direct method agrees with the MCMC within the highest posterior density (HPD) obtained by the MCMC method. The KDEs of the parameters acquired by the MCMC method enable the uncertainty of the parameters to be expressed in probability distributions rather than in confidence intervals. The final result proposes an initial CI of the 10 V output taps in the Zener devices without any calibration record of 8.8 months with a 0.91-month standard deviation for 90% of the measurement reliability target (MRT) and a 16 μV tolerance limit.
- 12 October 2020
- Published by IOP Publishing in Metrologia
- Vol. 57 (6) , 065007
Long-term drift analysis of Zener voltage standards and proposal of an initial calibration interval using calibration records accumulated for 15 years
In electrical metrology, voltage is a key quantity together with resistance for realising all electric standards in the low-frequency range. Zener voltage standards are accepted as the most stable to disseminate voltage references traceable to the Josephson standard devices. We study the long-term drift of the Zener devices to propose their initial calibration interval (CI), statistically analysing the calibration records accumulated for 15 years at the Korea Research Institute of Standards and Science (KRISS). First, we apply the direct method where the measurement reliability is obtained by integrating the probability density functions acquired from kernel density estimation (KDE). Markov chain Monte Carlo (MCMC) has been successfully demonstrated to determine the parameters of the Weibull reliability model. A numerical experiment was performed to confirm that the MCMC method works properly and is able to replace the S3 method of NCSLI. The direct method agrees with the MCMC within the highest posterior density (HPD) obtained by the MCMC method. The KDEs of the parameters acquired by the MCMC method enable the uncertainty of the parameters to be expressed in probability distributions rather than in confidence intervals. The final result proposes an initial CI of the 10 V output taps in the Zener devices without any calibration record of 8.8 months with a 0.91-month standard deviation for 90% of the measurement reliability target (MRT) and a 16 μV tolerance limit.
- 1 August 2017
- Published by Elsevier in Measurement
- Vol. 106, 31-34
Linearity evaluation of high-speed sampling ADC board
- 1 August 2017
- Published by Elsevier in Measurement
- Vol. 106, 31-34
Linearity evaluation of high-speed sampling ADC board
- 20 September 2005
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 95 (13) , 137002
Correlation between Superfluid Density andof UnderdopedNear the Superconductor-Insulator TransitionWe report measurements of the -plane superfluid density (magnetic penetration depth ) of heavily underdoped films of , with ’s from 6 to 50 K. We find the characteristic length for vortex unbinding transition equal to the film thickness, suggesting strongly coupled layers. At the lowest dopings, is as much as 5 times larger than the upper limit set by the 2D Kosterlitz-Thouless-Berezinskii transition temperature calculated for individual bilayers. Our main finding is that is not proportional to ; instead, we find . This conflicts with a popular point of view that quasi-2D thermal phase fluctuations determine the transition temperature.- 20 September 2005
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 95 (13) , 137002
Correlation between Superfluid Density andof UnderdopedNear the Superconductor-Insulator TransitionWe report measurements of the -plane superfluid density (magnetic penetration depth ) of heavily underdoped films of , with ’s from 6 to 50 K. We find the characteristic length for vortex unbinding transition equal to the film thickness, suggesting strongly coupled layers. At the lowest dopings, is as much as 5 times larger than the upper limit set by the 2D Kosterlitz-Thouless-Berezinskii transition temperature calculated for individual bilayers. Our main finding is that is not proportional to ; instead, we find . This conflicts with a popular point of view that quasi-2D thermal phase fluctuations determine the transition temperature.- Open Access
Correlation between superfluid density and Tc of underdoped YBa2Cu3O6+x near the superconductor-insulator transition
We report measurements of the ab-plane superfluid density Ns (magnetic penetration depth, \lambda) of severely underdoped films of YBa2Cu3O6+x, with Tc's from 6 to 50 K. Tc is not proportional to Ns(0); instead, we find Tc ~ Ns^{1/2.3 +/- 0.4}. At the lowest dopings, Tc is as much as 5 times larger than the upper limit set by the KTB transition temperature of individual CuO2 bilayers.
Open AccessCorrelation between superfluid density and Tc of underdoped YBa2Cu3O6+x near the superconductor-insulator transition
We report measurements of the ab-plane superfluid density Ns (magnetic penetration depth, \lambda) of severely underdoped films of YBa2Cu3O6+x, with Tc's from 6 to 50 K. Tc is not proportional to Ns(0); instead, we find Tc ~ Ns^{1/2.3 +/- 0.4}. At the lowest dopings, Tc is as much as 5 times larger than the upper limit set by the KTB transition temperature of individual CuO2 bilayers.