Daniel C. Marsh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Daniel C. Marsh has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Adam Berrington
University of Nottingham
1 shared publication - Christopher Mirfin
University of Nottingham
1 shared publication - Michal Považan
Russell H. Morgan Department of Radiology and Radiological Science The Johns Hopkins University School of Medicine Baltimore Maryland USA
1 shared publication - Penny A. Gowland
Sir Peter Mansfield Imaging Centre School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, UK
1 shared publication - Richard Bowtell
Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham
1 shared publication - Stephen Bawden
Sir Peter Mansfield Imaging Centre, National Institute for Health Research (NIHR) Nottingham Biomedical Research Centre, University of Nottingham, School of Physics, Nottingham, UK
1 shared publication
Latest Publications
- Open Access
Calibration-free regional RF shims for MR spectroscopy
Purpose: Sufficient control of the RF transmit field (B 1 + ) in small regions-of-interest (ROIs) is critical for single voxel MR spectroscopy at ultra-high field. Static RF shimming, using parallel transmit (pTx), can improve B 1 + , but must be calibrated for each participant and ROI, which limits its applicability. Additionally, specific-absorption-rate (SAR) becomes hard to predict. This work aimed to find RF shims, which can be applied to any participant, to produce the desired |B 1 + | within pre-defined target ROIs. Methods: RF shims were found offline by joint-optimisation on a database, comprising B 1 + maps from 11 subjects, considering ROIs in occipital cortex, hippocampus and posterior-cingulate, as well as the whole brain. The B 1 + magnitude achieved using calibration-free RF shims was compared to a tailored shimming approach, and MR spectra were acquired using tailored and calibration-free RF shimming in 4 participants. Global and local 10g SAR deposition were modelled. Results: Calibration-free RF shims resulted in similar |B 1 + | in small ROIs compared to tailored shimming, in addition to producing spectra of excellent quality and equivalent SNR. Only a small database size was required. SAR deposition was reduced compared to operating in quadrature mode for all ROIs. Conclusion: This work demonstrates that static RF shims, optimised offline for small regions in single voxel MRS, avoid the need for lengthy B 1 + mapping and pTx optimisation for each ROI and participant. Furthermore, power settings may be increased when using calibration-free shims to better take advantage of the flexibility provided by RF shimming for regional acquisition at ultra-high field.
Open AccessCalibration-free regional RF shims for MR spectroscopy
Purpose: Sufficient control of the RF transmit field (B 1 + ) in small regions-of-interest (ROIs) is critical for single voxel MR spectroscopy at ultra-high field. Static RF shimming, using parallel transmit (pTx), can improve B 1 + , but must be calibrated for each participant and ROI, which limits its applicability. Additionally, specific-absorption-rate (SAR) becomes hard to predict. This work aimed to find RF shims, which can be applied to any participant, to produce the desired |B 1 + | within pre-defined target ROIs. Methods: RF shims were found offline by joint-optimisation on a database, comprising B 1 + maps from 11 subjects, considering ROIs in occipital cortex, hippocampus and posterior-cingulate, as well as the whole brain. The B 1 + magnitude achieved using calibration-free RF shims was compared to a tailored shimming approach, and MR spectra were acquired using tailored and calibration-free RF shimming in 4 participants. Global and local 10g SAR deposition were modelled. Results: Calibration-free RF shims resulted in similar |B 1 + | in small ROIs compared to tailored shimming, in addition to producing spectra of excellent quality and equivalent SNR. Only a small database size was required. SAR deposition was reduced compared to operating in quadrature mode for all ROIs. Conclusion: This work demonstrates that static RF shims, optimised offline for small regions in single voxel MRS, avoid the need for lengthy B 1 + mapping and pTx optimisation for each ROI and participant. Furthermore, power settings may be increased when using calibration-free shims to better take advantage of the flexibility provided by RF shimming for regional acquisition at ultra-high field.