Cameron Storm
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Cameron Storm has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Rikki Nezich
Department of Medical Technology and Physics, Sir Charles Gairdner Hospital, Nedlands, Australia
2 shared publications Alicia Harvey
Medical Technology & Physics, Sir Charles Gairdner Hospital, Perth, Australia
1 shared publicationDavid Cryer
Department of Medical Technology and Physics, Sir Charles Gairdner Hospital, Nedlands, Australia
1 shared publication- Janette Atkinson
Department of Medical Technology and Physics, Sir Charles Gairdner Hospital, Nedlands, Australia
1 shared publication - Mario Djukelic
GenesisCare WA, Wembley, Australia
1 shared publication - Martin Andrew Ebert
Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, Australia
1 shared publication
Latest Publications
- Open Access
- 5 February 2024
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 47 (2) , 491-501
Construction and validation of an infant chest phantom for paediatric computed tomography
Paediatric imaging protocols should be carefully optimised to maintain the desired image quality while minimising the delivered patient dose. A paediatric chest phantom was designed, constructed and evaluated to optimise chest CT examinations for infants. The phantom was designed to enable dosimetry and image quality measurements within the anthropomorphic structure. It was constructed using tissue equivalent materials to mimic thoracic structures of infants, aged 0–6 months. The phantom materials were validated across a range of diagnostic tube voltages with resulting CT numbers found equivalent to paediatric tissues observed via a survey of clinical paediatric chest studies. The phantom has been successfully used to measure radiation dose and evaluate various image quality parameters for paediatric specific protocols.
- 5 February 2024
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 47 (2) , 491-501
Open AccessConstruction and validation of an infant chest phantom for paediatric computed tomography
Paediatric imaging protocols should be carefully optimised to maintain the desired image quality while minimising the delivered patient dose. A paediatric chest phantom was designed, constructed and evaluated to optimise chest CT examinations for infants. The phantom was designed to enable dosimetry and image quality measurements within the anthropomorphic structure. It was constructed using tissue equivalent materials to mimic thoracic structures of infants, aged 0–6 months. The phantom materials were validated across a range of diagnostic tube voltages with resulting CT numbers found equivalent to paediatric tissues observed via a survey of clinical paediatric chest studies. The phantom has been successfully used to measure radiation dose and evaluate various image quality parameters for paediatric specific protocols.
- 4 April 2023
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 46 (2) , 747-751
Establishment of a local diagnostic reference level for dental intraoral bitewing X-rays
- 4 April 2023
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 46 (2) , 747-751
Establishment of a local diagnostic reference level for dental intraoral bitewing X-rays
- Open Access
- 20 January 2023
- Published by Springer Nature in Research Square
Establishment of a diagnostic reference level for dental intraoral bitewing X-rays in Western Australia
Diagnostic reference levels (DRLs) for dental intraoral X-rays have been established in Western Australia. DRL values of 2.0 mGy incident air kerma (IAK) and 57 mGy cm2 air kerma-area product (KAP) for an adult posterior bitewing X-ray were determined based on 811 X-ray units surveyed. This IAK DRL value is greater than those established in several other nations and regions around the world in similar studies. Analyses of radiographic technique and equipment usage are included to provide broad guidance as to ways that imaging could be optimised, such as in the selection of exposure factors, collimators, image receptors, and X-ray unit models.
- 20 January 2023
- Published by Springer Nature in Research Square
Open AccessEstablishment of a diagnostic reference level for dental intraoral bitewing X-rays in Western Australia
Diagnostic reference levels (DRLs) for dental intraoral X-rays have been established in Western Australia. DRL values of 2.0 mGy incident air kerma (IAK) and 57 mGy cm2 air kerma-area product (KAP) for an adult posterior bitewing X-ray were determined based on 811 X-ray units surveyed. This IAK DRL value is greater than those established in several other nations and regions around the world in similar studies. Analyses of radiographic technique and equipment usage are included to provide broad guidance as to ways that imaging could be optimised, such as in the selection of exposure factors, collimators, image receptors, and X-ray unit models.
- 5 August 2020
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 43 (3) , 1125-1129
Mammography diagnostic reference levels in Western Australia
Mammography dose data has been collected from Western Australian units to establish Diagnostic Reference Levels for the state. Reference levels have been determined for a variety of phantom thicknesses for both full field digital mammography units and digital breast tomosynthesis units. Levels for the American College of Radiology (ACR) Phantom have been established as 1.3 mGy and 1.5 mGy mean glandular dose for full field digital mammography and digital breast tomosynthesis respectively. 2 cm PMMA was 0.9 mGy and 1.0 mGy and 6 cm PMMA had values of 2.0 mGy and 2.3 mGy. This data can be utilised to help establish national reference levels in the future.
- 5 August 2020
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 43 (3) , 1125-1129
Mammography diagnostic reference levels in Western Australia
Mammography dose data has been collected from Western Australian units to establish Diagnostic Reference Levels for the state. Reference levels have been determined for a variety of phantom thicknesses for both full field digital mammography units and digital breast tomosynthesis units. Levels for the American College of Radiology (ACR) Phantom have been established as 1.3 mGy and 1.5 mGy mean glandular dose for full field digital mammography and digital breast tomosynthesis respectively. 2 cm PMMA was 0.9 mGy and 1.0 mGy and 6 cm PMMA had values of 2.0 mGy and 2.3 mGy. This data can be utilised to help establish national reference levels in the future.