RNRikki Nezich

Rikki Nezich

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rikki Nezich has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    From point sources to phantoms: refining dose rate models in nuclear medicine with Tc-99m, F-18, I-131 and Lu-177

    by Joshua Ierace, Pejman Rowshanfarzad, Christine Sinnott, Rikki Nezich, Paul Brayshaw, Mario Djukelic

    Healthcare workers are often exposed to external radiation from patients who have been administered radionuclides for nuclear medicine (NM) studies, particularly during subsequent procedures requiring close contact. Traditional dose rate estimates commonly assume patients to be unattenuated point sources and apply inverse square law calculations, which tend to overestimate exposures at clinical distances. This study presents an experimental approach to quantify dose rates more accurately from NM patients using point, line, and phantom source models of Tc-99m, F-18, I-131, and Lu-177. Measurements were performed with calibrated ionisation chambers under controlled low-background conditions. Radionuclide activities were selected to achieve detectable dose rates while minimising staff exposure. Point and line source measurements provided baseline external exposure data across 10–100 cm. Phantom models, including a homogeneous water-filled NEMA body phantom and a PMMA neck phantom, were used to replicate clinical patient geometries. Dose rates were decay-corrected, normalised to activity, and fitted with biexponential models to generate exposure curves. Gamma factors (GFs) were evaluated at 0.3 m and 1.0 m from the centre of the radioactive source and compared with internationally recognised literature values. Self-absorption factors (SFs) were derived by comparing phantom and point source curves across clinical distances. Measured GFs showed excellent agreement with published data and internationally recognised standards, differing by only 2% for F-18 at both 30 cm (1.84 μSv/h/MBq) and 100 cm (0.161 μSv/h/MBq), and by 1% for I-131 at 30 cm (0.721 μSv/h/MBq). The average SF for F-18 (0.71 ± 0.04), representing patient self-attenuation for an unknown body orientation, was consistent with published Monte Carlo estimates. Differences reported in the literature were attributed to methodological variations, including the use of computational modelling rather than direct experimental measurements, along with variations in phantom design, source geometry, and detector configuration. This work presents an experimentally measured dataset with corresponding dose rate models for NM applications. The results contribute additional empirical evidence that may be used alongside established radiation protection methodologies to support assessments of shielding, procedure scheduling, and occupational and public radiation risk, potentially reducing reliance on overly conservative assumptions when evaluating dose rates at clinical distances.

  • Open Access

    Development and validation of a 3D-printed dosimetry phantom for paediatric radiology

    by Jonathon Richard Stone, Pejman Rowshanfarzad, Adriano Polpo, Chris Williams, Rikki Nezich

    Radiation dosimetry is essential in the optimisation and justification of medical imaging procedures. However, the complexity of modern imaging equipment often surpasses the capabilities of standard dose calculation software, necessitating the use of commercially available dosimetry phantoms, which are often prohibitively expensive. This study aimed to develop a cost-effective, 3D-printed newborn-equivalent dosimetry phantom for measuring organ and whole-body effective doses. Several Polylactic Acid (PLA)-based filaments were investigated for tissue equivalency through Hounsfield-value analysis via micro-CT (40–70 kVp) and clinical CT (70–140 kVp) measurements. Standard PLA at 93% (ρ = 1.14 g/cm 3 ) and 26% (ρ = 0.41 g/cm 3 ) infill density was selected for soft tissue and lung, respectively, while StoneFil composite PLA (FormFutura) at 81% (ρ = 1.21 g/cm 3 ) infill was chosen for bone. The phantom was modelled on a modified Cristy and Eckerman newborn design, with 21 sections generated using MATLAB and printed on a Bambu Lab X1 Carbon 3D printer. A total of 186 thermoluminescent dosimeter (TLD) capsules were embedded in the phantom, and TLD measurements from whole-body 60 kVp radiographs were compared with Monte Carlo (PCXMC 2.0) simulations for validation. The phantom demonstrated accurate dosimetry for the radiographic exposure, with average organ doses closely matching the simulated exposure, and the effective dose (ICRP 103) within 2% of the simulation. The phantom required 135 h to print, with a material cost of A$165. This study successfully developed and validated a cost-effective dosimetry phantom for paediatric radiography, with the potential to print larger phantoms for older children. Future work will explore the phantom’s application in other X-ray imaging modalities.


  • Open Access

    From Point Sources to Phantoms: Refining Dose Rate Models in Nuclear Medicine with Tc-99m, F-18, I-131 and Lu- 177

    by Joshua Ierace, Pejman Rowshanfarzad, Christine Sinnott, Rikki Nezich, Paul Brayshaw, Mario Djukelic

    Healthcare workers in nuclear medicine (NM) are often exposed to external radiation from patients who have been administered radiopharmaceuticals, particularly during procedures requiring close contact. Traditional dose rate estimates commonly assume patients to be unattenuated point sources and apply inverse square law calculations, which tend to overestimate exposures at clinical distances. This study presents an experimental approach to quantify dose rates more accurately from NM patients using point, line, and phantom source models of Tc-99m, F-18, I-131, and Lu-177.Measurements were performed with calibrated ionisation chambers under controlled low-background conditions. Radioisotope activities were selected to achieve detectable dose rates while minimising staff exposure. Point and line source measurements provided baseline external exposure data across 10–100 cm. Phantom models, including a homogeneous water-filled NEMA body phantom and a PMMA neck phantom, were used to replicate clinical patient geometries. Dose rates were decay-corrected, normalised to activity, and fitted with biexponential models to generate exposure curves. Gamma factors (GFs) were evaluated at 0.3 m and 1.0 m and compared with internationally recognised literature values. Self-absorption factors (SFs) were derived by comparing phantom and point source curves across clinical distances.Results showed that measured GFs agreed within 10% of published values for most isotopes, with discrepancies largely explained by methodological differences. SFs varied by isotope and geometry, with lateral phantom orientations exhibiting the highest attenuation. For F-18 and Tc-99m, phantom-derived SFs were consistent with patient data and Monte Carlo simulations. I-131 neck phantom results demonstrated orientation-dependent shielding, with posterior measurements showing the greatest attenuation.This work provides a validated dataset and modelling framework for dose rate estimation in NM. These results support evidence-based clinical decisions regarding shielding, procedure scheduling, and occupational safety, reducing reliance on overly conservative assumptions and enabling accurate, practical radiation protection strategies.


  • Open Access

    Radiation Dose and Risk in the Radiological Investigation of Suspected Non‐Accidental Injury ( NAI )

    by Tooba Zaidi, Rikki Nezich

    Introduction: Skeletal surveys are a series of X‐ray images used to identify bone injuries in suspected cases of non‐accidental injury (NAI). This study evaluates effective radiation doses and associated risks of radiation exposure from skeletal surveys that were performed on children under 5 years of age at a tertiary paediatric hospital in Australia. Methods: Radiographic exposure records were retrospectively analysed for 362 initial and follow‐up skeletal surveys conducted between 2018 and 2023 for suspected physical abuse. Effective doses and organ absorbed doses were calculated using PCXMC software against background equivalent radiation times (BERT) in Australia. Nominal risks of radiation‐induced cancer induction and fatality were estimated using Biologic Effects of Ionising Radiation (BEIR) VII risk coefficients. Results: The mean effective dose was 0.24 mSv for initial examinations and 0.18 mSv for follow‐up examinations, equivalent to 52 and 38 days of background radiation exposure, respectively. The averaged nominal risks associated with an initial skeletal survey are 9.3 in 10,000 for cancer induction, and 3.1 in 10,000 for fatal cancer. Variability of radiation effective dose is demonstrated, with an interquartile range of 0.17–0.30 mSv and an overall range of 0.04–0.76 mSv for initial skeletal surveys. Conclusion: Radiation doses for initial and follow‐up skeletal surveys performed for suspected NAI were determined from a large set of examinations. Several radiation risk metrics have been presented to assist healthcare professionals and caregivers in understanding the associated risks of radiation exposure.

  • Open Access

    Construction and validation of an infant chest phantom for paediatric computed tomography

    by Seonaid Rodgers, Janette Atkinson, David Cryer, Cameron Storm, Rikki Nezich, Martin A. Ebert, Pejman Rowshanfarzad

    Paediatric imaging protocols should be carefully optimised to maintain the desired image quality while minimising the delivered patient dose. A paediatric chest phantom was designed, constructed and evaluated to optimise chest CT examinations for infants. The phantom was designed to enable dosimetry and image quality measurements within the anthropomorphic structure. It was constructed using tissue equivalent materials to mimic thoracic structures of infants, aged 0–6 months. The phantom materials were validated across a range of diagnostic tube voltages with resulting CT numbers found equivalent to paediatric tissues observed via a survey of clinical paediatric chest studies. The phantom has been successfully used to measure radiation dose and evaluate various image quality parameters for paediatric specific protocols.