    Inconel 625–Yttria Stabilized Zirconia Composite and Coating Systems: Processing Routes, Microstructure, and Performance – A Comprehensive Review

    by Aseem Dubey, Akhilesh Arora

    The potable water can be produced most economically from saline/brackish water using solar still. The productivity can be further enhanced by increasing the basin water temperature and storing the dissipated thermal energy from the solar still by using energy storage materials for re-utilization at night. In the present study, considering the environmental revenue earned, an economic analysis of the viability of a single slope solar integrated with an evacuated tube collector (ETC) and paraffin wax (PCM) has been carried out. The ETC integrated solar still increased the yield by ~30.0% when paraffin wax was incorporated compared to the system without PCM, yielding annually to 1683 kg/m2 . The net CO2 mitigation, considering the 20 years life of the system, has been found to be 31.5 tons with a net annual environmental cash flow return of Rs. 1325. With the increase in the system’s life from 10-20 years, the cost of distillate decreased from Rs. 1.28 to Rs. 0.31 per liter at a 2% interest rate considering carbon credit. The payback period has been found in the range of 1.5-17.4 years for a system life of 10 and 20 years, respectively, at an interest rate range of 2-10%, and if distillate is sold at a selling rate from Rs.10.0-2.0/kg. The production cost from the present system is in the acceptable range compared to other designs with PCM.

  • Open Access

    Energetic and Exergetic Performance of PCM Incorporated Etc Integrated Solar Still Under Forced Mode

    by Aseem Dubey, Akhilesh Arora

    The incorporation of phase change material (PCM) enhances the productivity of the solar still as well as makes it continuously operative during low sunshine/nighttime. This study analyzes the performance of single slope solar still incorporated with paraffin wax as a PCM beneath the basin liner and further integrated with an evacuated tube collector under forced convection. The results have revealed that under similar climatic conditions, PCM-incorporated solar still improves the productivity by 30% compared to the system without PCM, yielding 5.064 kg/day using 15 kg PCM at 0.03 m water depth and a flow rate of 0.06 kg/s. The overall energetic and exergetic efficiencies have been found to be 39.56% and 4.05%. Irreversibility has been seen as a function of the intensity of available radiations during the daytime and is crucial at basin liner and, minimum at PCM. Moreover, at night, basin water has the highest irreversibility of ~78% (~30.0 W/m2), while PCM is at a minimum of ~2.0 W/m2. The effect of wind velocity has revealed an increase in energy efficiency by ~3%, reaching a maximum of 44.03% at an optimal speed of 3.0 m/s, while exergy efficiency decreased by ~11%. The increase in PCM and basin water mass has reduced the performance, reaching a maximum of 15 kg paraffin wax for a given water depth.


  • Open Access

    Energetic and exergetic performance of PCM incorporated ETC integrated solar still under forced mode

    by Aseem Dubey, Akhilesh Arora

    The incorporation of phase change material (PCM) enhances the productivity of the solar still as well as makes it continuously operative during low sunshine/night time. This study analyzes the performance of single slope solar still incorporated with paraffin wax as a PCM beneath the basin liner and further integrated with an evacuated tube collector under forced convection. The results have revealed that under similar climatic conditions, PCM-incorporated solar still improves the productivity by 30% compared to the system without PCM, yielding 5.064 kg/day using 15 kg PCM at 0.03 m water depth and flow rate of 0.06 kg/s. The overall energetic and exergetic efficiencies have been found to be 39.56% and 4.05%. Irreversibility has been seen as a function of the intensity of available radiations during the daytime and is crucial at basin liner and, minimum at PCM. Moreover, at night, basin water has the highest irreversibility of ~78% (~30.0 W/m2), while PCM is at a minimum of ~2.0 W/m2. The effect of wind velocity has revealed an increase in energy efficiency by ~3%, reaching a maximum of 44.03% at an optimal speed of 3.0 m/s, while exergy efficiency decreased by ~11%. The increase in PCM and basin water mass has reduced the performance, reaching a maximum of 15 kg paraffin wax for a given water depth.


  • Thermodynamic Performance Enhancement of an Air Conditioner With Dew Point Evaporative Cooler

    by Sunil Kumar Gupta, B. B. Arora, Akhilesh Arora

    The vapor-compression based conventional split air conditioners (CAC) consume a large portion of total electrical power and pose an alarming threat to global environment. The present work aims to reduce cooling load and power consumption of CAC by employing a dew point evaporative cooler (DPEC). DPEC consists of a counter flow type heat and mass exchanger with alternate layers of dry and wet channels. The intake air is sensibly cooled before entering the cooling room through the evaporator coil of the air-conditioner. Also, the working air (a part of outlet air in dry channel), after absorbing sensible heat of intake air and water vapors from the wet channel surface, is allowed to pass across the condenser coils. The intake dry bulb temperature (T0 = 29-44°C) and specific humidity (ω0 = 6-22g/kg) are taken as input parameters. While the cooled air entering the evaporator decreases the cooling load on the conditioned space, the compression work is also reduced due to increased heat transfer in the condenser. The maximum reductions in cooling load and monthly energy consumption at T0 =44°C and ω0 = 6 g/kg are found as 59.54% and 340kWh, respectively. The average energy savings with the DPEC system for hot-dry climate (from April to June) and hot-humid climate (from July to September) of New Delhi, India are observed to be 479.6kWh and 79.1kWh, respectively. The proposed system is found to payback in about 2.7 years.


  • Multi-Objective Optimization of an Inlet Air-Cooled Combined Cycle Power Plant

    by Ashutosh Mishra, B. B. Arora, Akhilesh Arora

    The present work aims to investigate the effect of inlet air cooling in conjunction with other input parameters on the exergetic performance of combined cycle power plants (CCPP). To mitigate the adverse effects of high ambient temperature on performance, the CCPP has been equipped with an inlet air cooler, which lowers the air temperature at the inlet of the compressor. Under a specific combination of input parameters, the analysis revealed a maximum increase in net specific work, efficiency, and exergetic efficiency of 14.16%, 3.93%, and 5.65%, respectively. Moreover, the effects of multiple input parameters were analyzed individually and in combination. This was done in order to identify the most influential exergy-affecting parameters for the CCPP, which turned out to be the degree of cooling, pressure ratio, and turbine inlet temperature. The simulated model is then subjected to two sets of multi-objective optimization using a genetic algorithm, considering the above parameters as design variables. According to the Pareto set of optimal solutions, cooling the inlet air by 16.5 K results in the highest net-specific work output and increased exergy destruction. Increased exergy destruction, on the other hand, is undesirable. However, if the cost of power per unit is high, this could be economically advantageous.


  • Exergy analysis of a vortex tube expansion two-stage transcritical N 2 O refrigeration cycle

    by Gaurav Jain, Akhilesh Arora, S. N. Gupta

    In the present article, two-stage transcritical cycle with expansion valve (TSTCEV) and two-stage transcritical cycle with vortex tube (TSTCVT) are compared mainly on the basis of the second law of thermodynamics. Natural refrigerant nitrous oxide (N2O) is used in both cycles for thermodynamic analysis. The gas cooler and evaporator temperatures are varied from 35°C to 55°C and −55°C to 5°C, respectively. The effects of various operating parameters on the optimum intercooler and gas cooler pressures, the coefficient of performance (COP), exergy destruction and the exergetic efficiency are presented. A component-wise exergy analysis of TSTCEV and TSTCVT shows that the use of the vortex tube instead of the expansion valve reduces the total exergy destruction and increases the exergetic efficiency as well as COP. The exergetic efficiency of TSTCVT is on average 9.17% to 11.68% higher than that of TSTCEV for considered operating conditions. Furthermore, the optimum intercooler and gas cooler pressures in TSTCVT are lower than those of TSTCEV. These results offer significant help for optimum design and the selection of appropriate operating conditions of TSTCVT using refrigerant N2O.


  • Open Access

    ENERGY AND EXERGY INVESTIGATIONS OF R1234yf AND R1234ze AS R134a REPLACEMENTS IN MECHANICALLY SUBCOOLED VAPOUR COMPRESSION REFRIGERATION CYCLE

    by Shyam Agarwal, Akhi̇lEsh Arora, Bharat Bhushan Arora

    The aim of present work is the evaluation of mechanically subcooled simple vapour compression refrigeration system on the basis of energy and exergy analysis, and compatibility of alternative low GWP and zero ODP HFOs R1234yf and R1234ze to replace HFC 134a. A computer program has been developed in Engineering Equation solver software to compute the system performance parameters such as COP, exergetic efficiency, total exergy destruction and exergy destruction ratio. The effect of degree of subcooling (5 to 30℃), evaporator temperature (-30℃ to 15℃), effectiveness of liquid vapour heat exchanger (0.2 to 1.0) and compressor efficiency (0.4 to 1.0) has been investigted on the performance parameters viz. exergy desturction, exergy destruction ratio (EDR) and exergetic efficiency of the system components. The results of current analysis highlight that the R1234ze is the best alternate refrigerant considered in the analysis and can replace R134a as the COP and exergetic efficiency of R1234ze are 1.87% and 1.88% more than that of R134a for 30℃ of subcoooling. However, R1234yf offers lower performance than R134a. The components condenser and evaporator are the sites of highest and lowest exergy destruction respectively for the refrigerants considered.


  • High-Temperature Distillation Using N-Parallel Evacuated Tube Collector Integrated With Double Slope Solar Still in Force Mode

    by Aseem Dubey, Akhilesh Arora

    In the present communication, a performance investigation of a double-slope solar still augmented with parallel evacuated tubes under forced mode is carried out for a modified geometry. A comprehensive mathematical model is used for the numerical simulation using the experimental data and incorporating the effect of variable flowrate, water depth, and the number of tubes. An optimum flowrate range ∼0.006–0.007 kg/s/tube is found irrespective of the number of tubes and basin water depth to extract optimal energy. The flowrate is validated with other experiments, carried out by various authors. At optimal flowrate with ten tubes and 0.005 m basin water depth, the system yields 6.644 kg, while overall energetic and exergetic efficiencies are observed as ∼33.8% and 4.9%, respectively. With an increase in the tubes as 20 and 30, the respective yields are found to be increased by ∼2.64% and ∼6.62% for nearly the same collector output temperature attainable (≈98.5°C), while the energy and exergy efficiencies decreased significantly by ∼24.6% and ∼38.6%, compared with ten tubes arrangement. Daily yield and overall exergy efficiency are increased by 13.3% and 19.3%, respectively, using a diffused reflector.