OSO. V. Sidorova

O. V. Sidorova

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


O. V. Sidorova has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative evaluation of fluoride ion release from glass ionomer cements for permanent fixation

    by I.V. Yanishen, O.V. Sidorova, R.V. Kuznietsov, V.YU. Bugaiev

    Background. In modern prosthodontics, the long-term stability of fixed restorations depends largely on the properties of the bonding materials. Glass ionomer cements are of great importance, as they combine reliable adhesion to hard dental tissues, biocompatibility, and the ability to release fluoride ions over an extended period. Purpose – of this study is to evaluate the ability of glass ionomer cements to release fluoride ions after final setting, based on the results of laboratory studies. Materials and Methods. The release of fluoride ions from glass ionomer cements for permanent restoration was investigated at the laboratory of Stoma JSC. Forty-five discshaped specimens (d = 8.60 mm; h = 1.65 mm) were prepared and divided into three groups (n = 15): «Ketac Cem» (Germany), «Riva» (Australia), and glass ionomer cement based on polycarboxylic and tartaric acids (Ukraine). The specimens were incubated in buffer, demineralization (pH 4.3), and remineralization (pH 7.0) solutions. Fluoride ion concentration was determined on days 9, 15, 21, and 30. Results. A comparative evaluation was conducted based on changes in fluoride ion release by three glass ionomer cements over a 30-day period in various solutions. For «Ketac Cem», a 32.6% decrease was observed in solution «A» (p0.05); in «B», 9.4% (p<0.05); and in «C», 17.1% (p<0.01). Conclusions. All of the glass ionomer cements studied are capable of releasing fluoride ions after setting, with the rate of release depending on the material composition and environmental conditions. The most pronounced changes in indicators were observed in «Ketac Cem» and «Riva» cements, whereas the glass ionomer cement based on polycarboxylic and tartaric acids was characterized by more stable fluoride release.

  • Open Access

    ASSESSMENT OF PATIENT ADAPTATION TO REMOVABLE DENTURES OVER TIME

    by I. V. Yanishen, N. V. Krychka, O. V. Sidorova, A. V. Pogorila, D. P. Kapelko

    Partial and complete edentulism remains common dental condition, leading to a growing need for prosthetic correction. The use of prosthetic appliances is often accompanied by adaptation difficulties, including discomfort, pain, speech impairment, and poor prosthesis retention, particularly in older patients. Therefore, studying the specifics of adaptation to removable prostheses is a pressing issue in modern prosthetic dentistry. Objective. To assess the adaptation and changes in quality of life among patients using partial and complete removable dentures over time. Participants and Methods. The study included 185 patients (90 men and 95 women) aged 35–85 years who underwent prosthetic correction with partial and complete removable dentures at the Department of Prosthodontics. The choice of prosthesis design was made on an individual basis, taking into account the clinical situation following an examination by prosthetic dentist. A clinical and statistical analysis of 185 outpatient records was conducted, along with a patient survey regarding adaptation time, quality of life, and primary complaints related to prosthesis use. Results. On the day the dentures were fitted, a statistically significant decline in quality of life was observed in all groups (p<0.001), followed by a gradual improvement in adaptation over the course of 14–33 days. The most pronounced difficulties in adaptation were observed in patients in the older age groups. The main complaints associated with the use of removable dentures were discomfort, speech difficulties, the gag reflex, and excessive salivation. In patients with complete removable dentures, these symptoms were observed significantly more frequently compared to partial dentures: gag reflex – 18.42±1.36% vs. 12.16±1.14% (p<0.05), excessive salivation – 14.83±1.11% vs. 6.17±0.21% (p0.01), speech impairment – 34.57±2.74% vs. 26.82±2.62% (p0.05), discomfort – 61.38±3.94% vs. 50.43±3.68% (p0.05). Patients with complete edentulism adapted to dentures more quickly compared to those with partial edentulism. Conclusion. A statistically significant association was found between patient age and the type of removable orthopedic prosthesis (p<0.05): partial dentures were more commonly used in patients in Group I, while complete dentures were more common in Group II. On the day of prosthesis placement, a significant decrease in quality of life indicators was observed in all groups (p<0.001), most pronounced in patients in the older age groups. The main complaints during the adaptation period were discomfort, pain, and speech impairment (p<0.05).

  • Open Access

    Differentiated Application of Dental Materials in the Treatment with Fixed Dental Prostheses: A Literature Review

    by Igor Yanishen, Olga Sidorova, Roman Kuznetsov, Alla Pogorila

    The article reviews modern approaches to selecting materials and fixation systems for the manufacture of fixed orthopedic dental structures. It is shown that their reliability and durability depend not only on the material's properties but also on the type of cement and adhesive system. The physico-mechanical properties of metal-ceramics, ceramics, zirconia, composite materials, and metal alloys are analyzed. It was established that modified glass ionomer and composite adhesive cements provide stronger fixation than traditional cements. The importance of digital CAD/CAM technologies and pressing, which improve the fit of structures and reduce the risk of microleakage and complications, is demonstrated. The need for differentiated material selection and fixation systems to increase the effectiveness of orthopedic treatment and the durability of fixed structures is substantiated. Objective: To analyze the scientific and practical works of domestic and foreign authors regarding the differentiated use of modern dental materials in the manufacture and fixation of fixed denture structures. Results: A search for scientific publications in the PubMed, Scopus, Web of Science, and Google Scholar databases identified 428 sources potentially relevant to the research topic. After removing 112 duplicates, 316 publications remained for further analysis. During the initial screening of titles and abstracts, 198 works were excluded, leaving 118 articles selected for full-text analysis. After a detailed analysis of the content, another 72 publications were excluded for irrelevance to the topic or for lacking relevant results. Ultimately, 46 scientific articles were included in the systematic review. The analysis included original research, systematic reviews, and meta-analyses dedicated to the use of dental materials in fixed orthopedic prosthetics and the evaluation of their physico-mechanical or clinical properties. Full-text articles in Ukrainian and English were considered. Duplicates, conference abstracts, short communications, clinical cases, and publications without full text were excluded from the analysis. Conclusions: The effectiveness of orthopedic treatment with fixed dentures largely depends on the selection of dental materials tailored to the various clinical stages. The physico-mechanical properties of materials, their adhesive characteristics, and dimensional stability affect the accuracy of structure fabrication, the quality of marginal fit, and the durability of restorations. The use of modern elastomeric impression materials and digital technologies increases the accuracy of anatomical structure transfer, while the use of adhesive composite cements ensures a stronger bond with tooth tissues and reduces the risk of microleakage.

  • Open Access

    PREPARATION OF ORTHOPAEDIC TREATMENT FOR PATIENTS WITH PERIODONTAL DISEASES AND REDUCED OCCLUSAL HEIGHT

    by K.YU. Andriienko, O.L. Fedotova, A.V. Pohorila, I.L. Dudina, O.V. Sidorova

    Periodontology is rapidly evolving, integrating advances in fundamental sciences, pharmacology, and dental materials. A thoroughly planned orthopaedic treatment protocol, aimed at restoring dentition defects and stabilising remaining teeth, normalises occlusal load, periodontal trophism, and reparative processes, thereby enhancing the effectiveness of periodontal disease management. The aim of our study was to improve the effectiveness of prosthetic treatment in patients with periodontal diseases accompanied by a decrease in interalveolar height through the use of a splint-cap. Participants and methods. Orthopaedic treatment of patients with periodontal tissue diseases was carried out at the Department of Prosthetic Dentistry of the University Dental Centre of Kharkiv National Medical University. To achieve the study objectives, 33 patients aged 45-70 years were examined and treated. The study included patients with periodontal diseases who underwent treatment according to the Jankelson technique followed by the fabrication of splint-caps. Depending on the applied orthopaedic treatment approach, the patients were divided into two clinical groups. Participants and Methods. Orthopaedic treatment of patients with periodontal diseases was performed at the Department of Prosthetic Dentistry of the University Dental Centre of Kharkiv National Medical University. To achieve the study objectives, 33 patients aged 45–70 years were examined and treated. The study included patients with periodontal disease who underwent treatment according to the Jankelson technique, followed by the fabrication of splint-caps. Depending on the orthopaedic treatment approach applied, the patients were divided into two clinical groups. Results. A reduction in tooth mobility was observed predominantly in areas previously affected by pronounced occlusal overload. In the first study group, positive dynamics of this parameter were recorded in 14 patients (82.35%), whereas in the comparison group improvement was noted in 11 patients (68.75%). A decrease in periodontal pocket depth of at least 1 mm, according to control probing, was observed in 13 patients in the first study group (76.47%) and in 11 patients in the second group (68.75%).In the first study group, normalization of masticatory muscle tone persisted throughout the entire observation period in 16 patients (94.12%). In the second group, a similar outcome was observed in 15 patients (93.75%); however, some of them required repeated correction of occlusal contacts. Conclusion. Comparative analysis of the two patient groups demonstrated that fixed splint-caps provide more effective stabilization of the mandibular neuromuscular position, more even distribution of occlusal load, greater periodontal tissue stability, and faster patient adaptation compared with removable splints. Fixed splint-caps significantly improved occlusal contacts, mandibular spatial position, and periodontal tissue condition (p < 0.05), while reducing the need for additional adjustments. These findings support their use as an effective component of comprehensive orthopaedic treatment for patients with periodontal disease and reduced interalveolar height.

  • Open Access

    INVESTGATION OF SOLUBILITY OF GLASS-COMPOSITE COATINGS FOR DENTAL IMPLANTS IN MODEL SOLUTIONS

    by Ахмед Альбакр, O.V. Kirichek, P.V. Maksymenko, O.V. Sidorova

    Relevance. Modern regenerative medicine, particularly in the field of implantology and bone tissue reconstruction, places high demands on materials used as implants or carriers for replacing or repairing defects. Purpose: to investigate the solubility and ability to form an apatite-like layer of the FAR-5X composite material in comparison with its analog. Materials and methods. The study of the solubility of the FAR-5X composite in comparison with the FAR-5 analog revealed an increase in the level of solubility, estimated by losses in distilled water (Wdw, 1.30 days%), saline (Wfr, 120 days%), citric acid solution (Wlc, 120 days%), and model solution (Wmc, 120 days%). The choice of solutions was based on ISO 10993-14-2011. The extreme solution method with citric acid buffer (pH = 3) is used to screen degradation products of bioactive materials. The model solution method (pH = 7.4) is applied to study degradation at 37 °C for 5 days. Distilled water (pH0 = 7.0) and saline solution simulate body plasma (90-92% water). The mass loss (B) was determined gravimetrically, and the concentration of Na+ and Ca2+ ions was determined using a PFM-UH.I. photometer, and phosphate groups were determined using a CFC-2 photocolorimeter. Results. The study has shown that the FAR-5X composite has increased ion mass loss (10 wt. %) and Na+ and Ca2+ concentrations (10-20 wt. %) in distilled water. The yield of phosphate groups (≈ 50 wt. %) is associated with the replacement of carbonate groups in the GAP, which confirms the presence of A-type GAP. The mass loss increases by 10-20 wt. % with an increase in the amount of CAP by 10 vol. %. The intensity of losses increases with the aggressiveness of physiological fluids. The determination of sodium ions (0.493 wt. %) and calcium ions (0.152 wt. %) in the DV creates conditions for the formation of an apatite layer at pH 7.25. In the model environment (MRO, pH = 7.25), the mass loss of FAR-5X decreases, indicating the formation of a calcium phosphate layer. Statistically significant differences between the materials were found on days 14, 21, 28, and 35, with the advantage of FAR-5X, which may indicate more active ion absorption. Conclusion. The introduction of chitosan into calcium phosphate SCM allows the creation of biocompatible materials for dental prosthetics, which contributes to the formation of a hardened mineralized layer at the implant-bone interface. FAR-5X composite can be used as a coating for titanium dentures that require rapid fusion.

  • Determination of the toxicity glass ionomer cements for permanent fixa-tion of non-removable constructions of dentures

    by O. Sidorova, I. Yanishen

    The experiment was carried out on groups of laboratory rats with a detailed study of the injected material, hematological, biochemical parameters of blood, behavioral reactions of animals and kidney function of experimental animals. The aim of the study was to determine the toxic effect of the new glass ionomer cement for permanent fixation of fixed structures of dentures on organs and tissues of laboratory animals. The keeping of animals and experiments were carried out in accordance with the "European Convention for the Protection of Vertebrate Animals used for Experimental and Other Scientific Purposes" (Strasbourg, 1986), Law of Ukraine No. 3447-IV on 21 Feb 2006 "On protection of animals from cruel treatment". Observations of the state and behavior of the animals showed that they tolerate daily contact with glass ionomer cement for one month satisfactorily. Indicators of liver weight in females (5.135±0.233) g and in males (6.234±0.342) g. In the experimental groups in contact with glass ionomer material, there were no significant differences in the number of erythrocytes [females – (4.86±0.26)·1012/l and in males – (4.53±0.14)·1012/l], hemoglobin [in females – (79.62±2.37) g/l, in males – (81.21±5.48) g/l], leukocytes [in males – (10.27±0.94)·109, in females – (9.81±0.68)·109/l]. The data obtained indicate the absence of toxic the effect of dental glass ionomer cement on peripheral blood. So the studied glass ionomer cement had no cytolyses effect on the liver. Changes in the composition of total protein [in males – (69.79±2.36) mmol/l, while in females – (67.35±2.47) mmol/l], albumin [in males – (28.56±1.87) mmol/l, in females – (28.49±2.36) mmol/l] in blood serum correspond to disorders of protein synthesis associated with damage to the liver parenchyma. The obtained results indicate that glass ionomer cement for permanent fixation of non-removable orthopedic prostheses did not have a toxic effect on the organs and tissues of experimental animals with prolonged use. Keywords: glass ionomer cement, permanent fixation, fixed structures of dentures, toxicity, experiment.