    Thermal Analysis and Simulation of an Uncovered Flat-plate Solar Collector with Parallel Tubes

    by Deli Goron, Ayang Albert, Roger Ekani

    The use of low-temperature solar thermal energy is of vital importance to households both in temperate zones for heating and in Sahelian zones for domestic hot water. This study focuses on the thermal analysis and simulation of an uncovered flat plate collector with parallel tubes using water as the heat transfer fluid. It is based on the analysis of the thermal performance and the careful selection of each component of the system, namely the coating, the absorber, and the insulator, to obtain optimal operation of the solar collector. The equations are presented in such a way that they can be easily solved by programming in the structured language MATLAB. The Newton-Raphson method was used to determine the temperature of the absorber wall after obtaining a nonlinear equation. Unlike stainless steel and Aluminum, the copper absorber does not store enough energy in itself, but transmits most of the energy flow to the heat transfer fluid, resulting in outlet temperatures of 82.62°C from a 2m tube, making copper the most suitable material for an absorber. TINOX and black chrome are better quality coatings, with a tube outlet temperature of 82.9°C, while that of the selective black plate is 80.12°C. The study also involved a comparative analysis of the thermal system with four types of insulation at the tube outlet. The water temperature ranged from 81.56°C to 82.32°C with insulation, meanwhile it was 73.37°C without insulation. As the fluid inlet temperature approaches ambient temperature, collector efficiency increases until it attains a maximum value of 62%.


  • Open Access

    Parameters Estimation and Curves Analysis for Faults Evaluation of a Degraded Photovoltaic Module

    by Albert Ayang, Deli Goron, Fabrice Mbakop, Yaouba Mbakop

    In the present work, a fault evaluation method for photovoltaic arrays based on fault parameters identification and curves analysis is proposed for diagnosing the state of photovoltaic generators. An overview of the components, the modelling of the photovoltaic generator and the meaning of the parameters is established for relating parameters to photovoltaic components and environmental conditions. The analysis and investigation of the relationship between the maximum power points and the parameters variations are performed. Investigation on how degradations and failure on photovoltaic systems can affect parameters, is established. In this context, the methodology for diagnosing and monitoring defects based on photovoltaic estimated parameters is developed; the optimization technique maximum likelihood, is used for extracting health and faults parameters from the measured curves of the photovoltaic array. From residual vectors, the parameters which vary more are the series resistance, the shunt resistor, and the current of photon. The maximum power also changes and decreases from its reference value. The validation results prove deviations on parameters, which means that there are degradations and failures on the ARCO Solar M75 array after 20 years of outdoors operation. So, at the end of this analysis, it is recommended to act on the PV system through junction box, cell edges, wiring, busbars, and connectors.

  • Open Access

    Performance Comparison of Empirical Models for Estimating Global Solar Irradiation in the Soudano-Sahelian Zone of Cameroon: The Case of the City of Maroua and Garoua

    by Kodji Deli, Etienne Houdji, Albert Ayang, Dieudonne Kaoga, Noel Djongyang

    The main objective of this study is to compare thirty-five (35) solar radiation models available in the open literature in order to predict monthly solar radiation in two main cities of Cameroon. This estimation and comparison are based on selected statistical comparison parameters named, root mean square error (RMSE), mean bias error (MBE), mean percentage error (MPE) and determination coefficient (R 2 ). These different models are implemented using regression analysis tools named Exel and MATLAB. Estimated values were compared with measured values according to normalized values of statistical parameters, using measured meteorological data of more than 19 years, from 1984 to 2015. All the models have been classified with their associated ranking according to their statistical parameter accuracy. From this study it appears that the models of Ertekin and Yaldiz (MOD20), Togrul and Onat (MOD28), are more accurate than other models. Indeed, for the city of Maroua (MBE%=-2.82E-14; RMSE%=0.862; MPE=-0.00845; R 2 =0.985), while for Garoua (MBE%=-9.21E-15; RMSE%=0.806; MPE=-0.00631; R 2 =0.959). according to their accuracy these models can be therefore be used to predict monthly solar radiation for soudano-sahelian regions of Cameroon. Correlation equations found in this paper will help solar energy researcher to estimate data with trust because of its fine agreement with the observed one. hence the models presented in this study could be used to evaluate accurately the solar radiation at any locations with similar climate.


  • Least square estimator and IEC-60891 procedure for parameters estimation of single-diode model of photovoltaic generator at standard test conditions (STC)

    by Albert Ayang, René Wamkeue, Mohand Ouhrouche, Mohamad Saad, Tommy Andy Tameghe, Kodji Deli, Pierre Tchakoua Takoutsing


  • Open Access

    An investigation of incremental conductance based maximum power point tracking for photovoltaic water pumping system performances

    by Deli Kodji, Etienne Tchoffo Houdji, Noël Djongyang, Albert Ayang, Jean Gaston Tamba

    In this work, each components of the photovoltaic water pumping system have been modeled in the Matlab/Simulink platform using meteorological data obtained from the field for the specific month corresponding to the hottest one of the year and for different total heads or pump loads. Optimization is done using the incremental conductance MPPT techniques which help to track the maximum power available in the photovoltaic module at each time and then feed the pump with optimal power. The results of this simulations show the effectiveness of the optimized system compare to the direct-coupled one. For the considered water pumps, daily flow rates are predicted and permit to calculate monthly total volume of water which is in the range of 122 m3 to 200 m3 for the total heads in the range of 60 m to 24 m with optimization and in the range of 12 m3 to 43 m3 for the same range of total heads without optimization. This study also shows the relevance of the optimized system compare to the direct-coupled system for providing water in rural areas of soudano-sahelian zone of Cameroon.


  • Open Access

    Power Consumption: Base Stations of Telecommunication in Sahel Zone of Cameroon: Typology Based on the Power Consumption—Model and Energy Savings

    by Albert Ayang, Paul-Salomon Ngohe-Ekam, Bossou Videme, Jean Temga

    In this paper, the work consists of categorizing telecommunication base stations (BTS) for the Sahel area of Cameroon according to their power consumption per month. It consists also of proposing a model of a power consumption and finally proceeding to energy audits in each type of base station in order to outline the possibilities of realizing energy savings. Three types of telecommunication base stations (BTS) are found in the Sahel area of Cameroon. The energy model takes into account power consumption of all equipment located in base stations (BTS). The energy audits showed that mismanagement of lighting systems, and of air-conditioning systems, and the type of buildings increased the power consumption of the base station. By applying energy savings techniques proposed for base stations (BTS) in the Sahel zone, up to 17% of energy savings are realized in CRTV base stations, approximately 24.4% of energy are realized in the base station of Missinguileo, and approximately 14.5% of energy savings are realized in the base station of Maroua market.