YZYu-Zhong Zhang

Yu-Zhong Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yu-Zhong Zhang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Number Concentration Measurements of Polystyrene Submicrometer Particles

    by Paul C. DeRose, Kurt D. Benkstein, Elzafir B. Elsheikh, Adolfas K. Gaigalas, Sean E. Lehman, Dean C. Ripple, Linhua Tian, Wyatt N. Vreeland, Eric J. Welch, Adam W. York, et al.

    The number of techniques to measure number concentrations and size distributions of submicrometer particles has recently increased. Submicrometer particle standards are needed to improve the accuracy and reproducibility of these techniques. The number concentrations of fluorescently labeled polystyrene submicrometer sphere suspensions with nominal 100 nm, 200 nm and 500 nm diameters were measured using seven different techniques. Diameter values were also measured where possible. The diameter values were found to agree within 20%, but the number concentration values differed by as much as a factor of two. Accuracy and reproducibility related with the different techniques are discussed with the goal of using number concentration standards for instrument calibration. Three of the techniques were used to determine SI-traceable number concentration values, and the three independent values were averaged to give consensus values. This consensus approach is proposed as a protocol for certifying SI-traceable number concentration standards.


  • Open Access

    Sources of Variability in the Response of Labeled Microspheres and B Cells during the Analysis by a Flow Cytometer

    by Adolfas K. Gaigalas, Yu-Zhong Zhang, Linhua Tian, Lili Wang

    A stochastic model of the flow cytometer measurement process was developed to assess the nature of the observed coefficient of variation (CV%) of the mean fluorescence intensity (MFI) from a population of labeled microspheres (beads). Several sources of variability were considered: the total number of labels on a bead, the path through the laser beam, the optical absorption cross-section, the quantum yield, the numerical aperture of the collection optics, and the photoelectron conversion efficiency of the photomultiplier (PMT) cathode. The variation in the number of labels on a bead had the largest effect on the CV% of the MFI of the bead population. The variation in the path of the bead through the laser beam was minimized using flat-top lasers. The variability in the average optical properties of the labels was of minor importance for beads with sufficiently large number of labels. The application of the bead results to the measured CV% of labeled B cells indicated that the measured CV% was a reliable measure of the variability of antibodies bound per cell. With some modifications, the model can be extended to multicolor flow cytometers and to the study of CV% from cells with low fluorescence signal.


  • Open Access

    Expanding NIST Calibration of Fluorescent Microspheres for Flow Cytometry to More Fluorescence Channels and Smaller Particles

    by Paul DeRose, Linhua Tian, Elzafir Elsheikh, Aaron Urbas, Yu-Zhong Zhang, Lili Wang

    The National Institute of Standards and Technology (NIST), the National Institutes of Health (NIH) and other industry stakeholders have been working together to enable fluorescence intensities of flow cytometer calibration beads to be assigned quantitative equivalent reference fluorophore (ERF) values with high accuracy and precision. The ultimate goal of this effort is to accurately quantify the number of antibodies bound to individual living cells. The expansion of this effort to assign ERF values to more than 50 fluorescence channels and particles with diameters ranging from 10 μm down to 80 nm is reported here.