Ledia Lilaj
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ledia Lilaj has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Ingolf Sack
Department of Radiology, Charité – Universitätsmedizin Berlin, Berlin, Germany
3 shared publications - Jürgen Braun
Institute of Medical Informatics, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
3 shared publications Gergely Bertalan
Department of Radiology Charité–Universitätsmedizin Berlin Berlin Germany
2 shared publications- Helge Herthum
Berlin Center for Advanced Neuroimaging Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt‐Universität zu Berlin, and Berlin Institute of Health Berlin Germany
2 shared publications - Mehrgan Shahryari
Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
2 shared publications - Sebastian Hirsch
Atmosfair gGmbh, Berlin, Germany
2 shared publications
Latest Publications
- Open Access
- 10 May 2025
- Published by Elsevier in Photoacoustics
- Vol. 44, 100727
Scale-equivariant deep model-based optoacoustic image reconstruction
- 10 May 2025
- Published by Elsevier in Photoacoustics
- Vol. 44, 100727
Open AccessScale-equivariant deep model-based optoacoustic image reconstruction
- Open Access
- 1 August 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (08) , 080801-15
Tutorial on phantoms for photoacoustic imaging applications
Central to the process of successfully translating a novel medical imaging modality lies accurate characterization of device performance and standardization of measurements. For this purpose, test objects with well-defined properties are used to relate a measured imaging signal to the underlying ground-truth property. A subset of these test objects is referred to as tissue-mimicking phantoms, which are artificial objects specifically designed to mimic certain properties of real-world tissues, objects or materials for calibration, testing, and validation purposes. Phantoms are essential to establish consensus performance test methods and support future standards development in biomedical imaging, enabling quality assurance and control as well as performance comparison of different imaging equipment during development and marketing.
- 1 August 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (08) , 080801-15
Open AccessTutorial on phantoms for photoacoustic imaging applications
Central to the process of successfully translating a novel medical imaging modality lies accurate characterization of device performance and standardization of measurements. For this purpose, test objects with well-defined properties are used to relate a measured imaging signal to the underlying ground-truth property. A subset of these test objects is referred to as tissue-mimicking phantoms, which are artificial objects specifically designed to mimic certain properties of real-world tissues, objects or materials for calibration, testing, and validation purposes. Phantoms are essential to establish consensus performance test methods and support future standards development in biomedical imaging, enabling quality assurance and control as well as performance comparison of different imaging equipment during development and marketing.
- Open Access
- 28 June 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (5) , 2552-2561
Inversion‐recovery MR elastography of the human brain for improved stiffness quantification near fluid–solid boundaries
Purpose: In vivo MR elastography (MRE) holds promise as a neuroimaging marker. In cerebral MRE, shear waves are introduced into the brain, which also stimulate vibrations in adjacent CSF, resulting in blurring and biased stiffness values near brain surfaces. We here propose inversion‐recovery MRE (IR‐MRE) to suppress CSF signal and improve stiffness quantification in brain surface areas.Methods: Inversion‐recovery MRE was demonstrated in agar‐based phantoms with solid‐fluid interfaces and 11 healthy volunteers using 31.25‐Hz harmonic vibrations. It was performed by standard single‐shot, spin‐echo EPI MRE following 2800‐ms IR preparation. Wave fields were acquired in 10 axial slices and analyzed for shear wave speed (SWS) as a surrogate marker of tissue stiffness by wavenumber‐based multicomponent inversion.Results: Phantom SWS values near fluid interfaces were 7.5 ± 3.0% higher in IR‐MRE than MRE (P= .01). In the brain, IR‐MRE SNR was 17% lower than in MRE, without influencing parenchymal SWS (MRE: 1.38 ± 0.02 m/s; IR‐MRE: 1.39 ± 0.03 m/s;P= .18). The IR‐MRE tissue–CSF interfaces appeared sharper, showing 10% higher SWS near brain surfaces (MRE: 1.01 ± 0.03 m/s; IR‐MRE: 1.11 ± 0.01 m/s;P< .001) and 39% smaller ventricle sizes than MRE (P< .001).Conclusions: Our results show that brain MRE is affected by fluid oscillations that can be suppressed by IR‐MRE, which improves the depiction of anatomy in stiffness maps and the quantification of stiffness values in brain surface areas. Moreover, we measured similar stiffness values in brain parenchyma with and without fluid suppression, which indicates that shear wavelengths in solid and fluid compartments are identical, consistent with the theory of biphasic poroelastic media.
- 28 June 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (5) , 2552-2561
Open AccessInversion‐recovery MR elastography of the human brain for improved stiffness quantification near fluid–solid boundaries
Purpose: In vivo MR elastography (MRE) holds promise as a neuroimaging marker. In cerebral MRE, shear waves are introduced into the brain, which also stimulate vibrations in adjacent CSF, resulting in blurring and biased stiffness values near brain surfaces. We here propose inversion‐recovery MRE (IR‐MRE) to suppress CSF signal and improve stiffness quantification in brain surface areas.Methods: Inversion‐recovery MRE was demonstrated in agar‐based phantoms with solid‐fluid interfaces and 11 healthy volunteers using 31.25‐Hz harmonic vibrations. It was performed by standard single‐shot, spin‐echo EPI MRE following 2800‐ms IR preparation. Wave fields were acquired in 10 axial slices and analyzed for shear wave speed (SWS) as a surrogate marker of tissue stiffness by wavenumber‐based multicomponent inversion.Results: Phantom SWS values near fluid interfaces were 7.5 ± 3.0% higher in IR‐MRE than MRE (P= .01). In the brain, IR‐MRE SNR was 17% lower than in MRE, without influencing parenchymal SWS (MRE: 1.38 ± 0.02 m/s; IR‐MRE: 1.39 ± 0.03 m/s;P= .18). The IR‐MRE tissue–CSF interfaces appeared sharper, showing 10% higher SWS near brain surfaces (MRE: 1.01 ± 0.03 m/s; IR‐MRE: 1.11 ± 0.01 m/s;P< .001) and 39% smaller ventricle sizes than MRE (P< .001).Conclusions: Our results show that brain MRE is affected by fluid oscillations that can be suppressed by IR‐MRE, which improves the depiction of anatomy in stiffness maps and the quantification of stiffness values in brain surface areas. Moreover, we measured similar stiffness values in brain parenchyma with and without fluid suppression, which indicates that shear wavelengths in solid and fluid compartments are identical, consistent with the theory of biphasic poroelastic media.
- Open Access
- 26 October 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (4) , 1962-1973
Reduction of breathing artifacts in multifrequency magnetic resonance elastography of the abdomen
Purpose: With abdominal magnetic resonance elastography (MRE) often suffering from breathing artifacts, it is recommended to perform MRE during breath‐hold. However, breath‐hold acquisition prohibits extended multifrequency MRE examinations and yields inconsistent results when patients cannot hold their breath. The purpose of this work was to analyze free‐breathing strategies in multifrequency MRE of abdominal organs.Methods: Abdominal MRE with 30, 40, 50, and 60 Hz vibration frequencies and single‐shot, multislice, full wave‐field acquisition was performed four times in 11 healthy volunteers: once with multiple breath‐holds and three times during free breathing with ungated, gated, and navigated slice adjustment. Shear wave speed maps were generated by tomoelastography inversion. Image registration was applied for correction of intrascan misregistration of image slices. Sharpness of features was quantified by the variance of the Laplacian.Results: Total scan times ranged from 120 seconds for ungated free‐breathing MRE to 376 seconds for breath‐hold examinations. As expected, free‐breathing MRE resulted in larger organ displacements (liver, 4.7 ± 1.5 mm; kidneys, 2.4 ± 2.2 mm; spleen, 3.1 ± 2.4 mm; pancreas, 3.4 ± 1.4 mm) than breath‐hold MRE (liver, 0.7 ± 0.2 mm; kidneys, 0.4 ± 0.2 mm; spleen, 0.5 ± 0.2 mm; pancreas, 0.7 ± 0.5 mm). Nonetheless, breathing‐related displacement did not affect mean shear wave speed, which was consistent across all protocols (liver, 1.43 ± 0.07 m/s; kidneys, 2.35 ± 0.21 m/s; spleen, 2.02 ± 0.15 m/s; pancreas, 1.39 ± 0.15 m/s). Image registration before inversion improved the quality of free‐breathing examinations, yielding no differences in image sharpness to uncorrected breath‐hold MRE in most organs (P> .05).Conclusion: Overall, multifrequency MRE is robust to breathing when considering whole‐organ values. Respiration‐related blurring can readily be corrected using image registration. Consequently, ungated free‐breathing MRE combined with image registration is recommended for multifrequency MRE of abdominal organs.
- 26 October 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (4) , 1962-1973
Open AccessReduction of breathing artifacts in multifrequency magnetic resonance elastography of the abdomen
Purpose: With abdominal magnetic resonance elastography (MRE) often suffering from breathing artifacts, it is recommended to perform MRE during breath‐hold. However, breath‐hold acquisition prohibits extended multifrequency MRE examinations and yields inconsistent results when patients cannot hold their breath. The purpose of this work was to analyze free‐breathing strategies in multifrequency MRE of abdominal organs.Methods: Abdominal MRE with 30, 40, 50, and 60 Hz vibration frequencies and single‐shot, multislice, full wave‐field acquisition was performed four times in 11 healthy volunteers: once with multiple breath‐holds and three times during free breathing with ungated, gated, and navigated slice adjustment. Shear wave speed maps were generated by tomoelastography inversion. Image registration was applied for correction of intrascan misregistration of image slices. Sharpness of features was quantified by the variance of the Laplacian.Results: Total scan times ranged from 120 seconds for ungated free‐breathing MRE to 376 seconds for breath‐hold examinations. As expected, free‐breathing MRE resulted in larger organ displacements (liver, 4.7 ± 1.5 mm; kidneys, 2.4 ± 2.2 mm; spleen, 3.1 ± 2.4 mm; pancreas, 3.4 ± 1.4 mm) than breath‐hold MRE (liver, 0.7 ± 0.2 mm; kidneys, 0.4 ± 0.2 mm; spleen, 0.5 ± 0.2 mm; pancreas, 0.7 ± 0.5 mm). Nonetheless, breathing‐related displacement did not affect mean shear wave speed, which was consistent across all protocols (liver, 1.43 ± 0.07 m/s; kidneys, 2.35 ± 0.21 m/s; spleen, 2.02 ± 0.15 m/s; pancreas, 1.39 ± 0.15 m/s). Image registration before inversion improved the quality of free‐breathing examinations, yielding no differences in image sharpness to uncorrected breath‐hold MRE in most organs (P> .05).Conclusion: Overall, multifrequency MRE is robust to breathing when considering whole‐organ values. Respiration‐related blurring can readily be corrected using image registration. Consequently, ungated free‐breathing MRE combined with image registration is recommended for multifrequency MRE of abdominal organs.
- Open Access
- 9 September 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (3) , 1655-1668
Separation of fluid and solid shear wave fields and quantification of coupling density by magnetic resonance poroelastography
Purpose Biological soft tissues often have a porous architecture comprising fluid and solid compartments. Upon displacement through physiological or externally induced motion, the relative motion of these compartments depends on poroelastic parameters, such as coupling density () and tissue porosity. This study introduces inversion recovery MR elastography (IR‐MRE) (1) to quantify porosity defined as fluid volume over total volume, (2) to separate externally induced shear strain fields of fluid and solid compartments, and (3) to quantify coupling density assuming a biphasic behavior of in vivo brain tissue. Theory and Methods Porosity was measured in eight tofu phantoms and gray matter (GM) and white matter (WM) of 21 healthy volunteers. Porosity of tofu was compared to values obtained by fluid draining and microscopy. Solid and fluid shear‐strain amplitudes and were estimated both in phantoms and in in vivo brain. Results T1‐based measurement of tofu porosity agreed well with reference values (R = 0.99, P < .01). Brain tissue porosity was 0.14 ± 0.02 in GM and 0.05 ± 0.01 in WM (P < .001). Fluid shear strain was found to be phase‐locked with solid shear strain but had lower amplitudes in both tofu phantoms and brain tissue (P < .05). In accordance with theory, tofu and brain were negative. Conclusion IR‐MRE allowed for the first time separation of shear strain fields of solid and fluid compartments for measuring coupling density according to the biphasic theory of poroelasticity. Thus, IR‐MRE opens horizons for poroelastography‐derived imaging markers that can be used in basic research and diagnostic applications.
- 9 September 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (3) , 1655-1668
Open AccessSeparation of fluid and solid shear wave fields and quantification of coupling density by magnetic resonance poroelastography
Purpose Biological soft tissues often have a porous architecture comprising fluid and solid compartments. Upon displacement through physiological or externally induced motion, the relative motion of these compartments depends on poroelastic parameters, such as coupling density () and tissue porosity. This study introduces inversion recovery MR elastography (IR‐MRE) (1) to quantify porosity defined as fluid volume over total volume, (2) to separate externally induced shear strain fields of fluid and solid compartments, and (3) to quantify coupling density assuming a biphasic behavior of in vivo brain tissue. Theory and Methods Porosity was measured in eight tofu phantoms and gray matter (GM) and white matter (WM) of 21 healthy volunteers. Porosity of tofu was compared to values obtained by fluid draining and microscopy. Solid and fluid shear‐strain amplitudes and were estimated both in phantoms and in in vivo brain. Results T1‐based measurement of tofu porosity agreed well with reference values (R = 0.99, P < .01). Brain tissue porosity was 0.14 ± 0.02 in GM and 0.05 ± 0.01 in WM (P < .001). Fluid shear strain was found to be phase‐locked with solid shear strain but had lower amplitudes in both tofu phantoms and brain tissue (P < .05). In accordance with theory, tofu and brain were negative. Conclusion IR‐MRE allowed for the first time separation of shear strain fields of solid and fluid compartments for measuring coupling density according to the biphasic theory of poroelasticity. Thus, IR‐MRE opens horizons for poroelastography‐derived imaging markers that can be used in basic research and diagnostic applications.