Time and Energy Characterization of Semi-Monolithic Detectors With Different Treatments and SiPMs Suitable for Clinical Imaging
- 1 August 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 7 (8) , 785-793
Abstract
The use of detectors based on semi-monolithic crystals can be of interest to clinical PET scanners due to their time of flight (TOF) and depth of interaction (DOI) capabilities. In this work, timing and energy characterization of four different detector configurations based on arrays of 8 LYSO slabs of 25.4×3.1×20 mm each coupled to SiPMs have been carried out. On the one hand, two different surface treatments have been studied. In one configuration, all the slab surfaces were treated with ESR (named ESR). In the other configuration, a retroreflector layer was added to the entrance face and the pixelated external faces were painted black (named ESR+B+RR). On the other hand, two different SiPM array models belonging to the series S13 and S14 from Hamamatsu Photonics were also compared. In all cases, the readout was performed by the TOFPET2 ASIC. The results show an energy resolution and a detector time resolution (DTR) as good as 12.5% and 193 ps, respectively, for the ESR treatment and the S13 photosensor. For the ESR+B+RR treatment and S13, the energy resolution and DTR are 14.6% and 238 ps, respectively. When using the S14, the energy resolutions and DTRs are, respectively, 11.6% and 219 ps for the ESR treatment, and 14.2% and 339 ps for the ESR+B+RR treatment.Keywords
Funding Information
- Ministerio de Ciencia, Innovaci?n y Universidades (PID2019-107790RB-C21)
- Generalitat Valenciana (ACIF/2019/112, APOSTD/2021/033, IDIFEDER/2021/004)
- Conselleria de Sanitat Universal i Salut Publica of the Goverment of Valencia Region (Imagen Molecular de Alta Sensibilidad (IMAS))
This publication has 20 references indexed in Scilit:
- Characterization of a High-Aspect Ratio Detector With Lateral Sides Readout for Compton PETIEEE Transactions on Radiation and Plasma Medical Sciences, 2020
- Minimization of parallax error in positron emission tomography using depth of interaction capable detectors: methods and apparatusBiomedical Physics & Engineering Express, 2019
- Experimental characterization of the TOFPET2 ASICJournal of Instrumentation, 2019
- Performance of long rectangular semi‐monolithic scintillator PET detectorsMedical Physics, 2019
- Performance Study of a Large Monolithic LYSO PET Detector With Accurate Photon DOI Using Retroreflector LayersIEEE Transactions on Radiation and Plasma Medical Sciences, 2017
- A multiplexed TOF and DOI capable PET detector using a binary position sensitive networkPhysics in Medicine & Biology, 2016
- Recent developments in time-of-flight PETEJNMMI Physics, 2016
- Preliminary evaluation of a monolithic detector module for integrated PET/MRI scanner with high spatial resolutionJournal of Instrumentation, 2015
- Improving the Time Resolution of TOF-PET Detectors by Double-Sided ReadoutIEEE Transactions on Nuclear Science, 2014
- Sub-200 ps CRT in monolithic scintillator PET detectors using digital SiPM arrays and maximum likelihood interaction time estimationPhysics in Medicine & Biology, 2013