JSJennifer Sha

Jennifer Sha

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jennifer Sha has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Visual performance of spectacle films utilising opaque, non-refractive features for potential myopia management

    by Jennie Diec, Daniel Tilia, Jennifer Sha, Karen Lahav-Yacouel, Klaus Ehrmann, Cathleen Fedtke, Ravi C Bakaraju

    A non-refractive approach for potential myopia management is introduced as spectacle films with opaque features, hypothesised to modulate retinal ganglion cell activity away from the baseline state of the eye. Visual performance of these spectacle films is currently unknown. The aim of this work is to compare the visual performance of spectacle films with opaque non-refractive features (test), MiYOSMART (control: MS), and single vision (control: SV) lenses. This was a prospective, randomised, unmasked, cross-over study where 37 myopic adults (18-42 years) wore each lens for a minimum of 5 days. Subjective visual performance was assessed with a 1-10 numeric rating scale for clarity of vision, vision at night, vision when walking, and overall vision satisfaction and visual acuity (monocular at 6 m and binocular at 6 m and 40 cm). Willingness-to-purchase, based on vision and myopia efficacy, was assessed with a binary Yes/No response. Test and SV were rated higher than MS (p ≤ 0.005) for all subjective ratings, while SV was rated higher than test (p ≤ 0.02) for all ratings except vision when walking (p = 0.11). A higher proportion were willing to purchase both test and SV compared to MS based on vision (p ≤ 0.001), with no difference between test and SV (p = 0.20). A higher proportion were willing to purchase SV compared to MS based on myopia efficacy (p = 0.005), with no difference between test and either control (p > 0.06). SV was significantly better than MS for acuity at 40 cm (p = 0.004) with no differences between lenses for other acuity measurements (p > 0.1). Test offered better subjective visual performance than MS with higher proportions of participants willing to purchase based on vision. Test offered worse subjective visual performance than SV with no differences in willingness-to-purchase questions. SV offered better visual performance than MS and higher proportions of participants willing to purchase for vision or myopia management.


  • Visual performance of phase alteration utilizing sub‐elements lenses for potential myopia management

    by Karen Lahav‐Yacouel, Daniel Tilia, Darrin Falk, Jennie Diec, Jennifer Sha, Cathleen Fedtke, Klaus Ehrmann, Ravi C. Bakaraju

    Purpose: To compare the visual performance (VP) of P.A.U.S.E. spectacle lenses (tests) against defocus incorporated multiple segments (DIMS; control). Methods: This randomized, single‐masked study included 48 participants aged 18–41 years who wore five tests (T1, T2, T4, T5, T6) and DIMS. VP was assessed through the full‐lens and inferior treatment zone. Full‐lens visual‐acuity (VA) based measurements comprised monocular high‐ and low‐contrast VA (HCVA/LCVA) at 6 m and binocular HCVA at 6 m and 40 cm. Assessments through the treatment zone comprised HCVA at 40 cm and subjective ratings (1–10 scale) of near vision‐clarity and ease‐of‐reading. VP was assessed after 3 days of wear (full‐lens) using subjective ratings of vision‐clarity, night‐vision, vision‐while‐walking, eyestrain, overall‐vision‐satisfaction, and willingness‐to‐purchase (yes/no: based on vision and myopia management efficacy). Analyses were performed using linear mixed models and the X 2 test. Significance was set at 5%. Results: Full‐lens binocular HCVA at 40 cm was significantly better with three tests (T2, T4, T5) compared to DIMS ( p ≤ 0.022), whereas there were no differences between any test and DIMS for monocular or binocular HCVA at 6 m ( p > 0.5). Full‐lens monocular LCVA at 6 m was significantly better with DIMS compared to T4 ( p = 0.0057). Through the treatment zone, four tests (T2, T4, T5, T6) were significantly better than DIMS for binocular HCVA at 40 cm ( p < 0.0001), near vision‐clarity ( p ≤ 0.0011) and ease‐of‐reading ( p ≤ 0.0014). T2 was rated significantly higher than DIMS for night‐vision ( p = 0.0085) and overall‐vision‐satisfaction ( p = 0.0495), whereas DIMS was rated higher than T1 for vision‐clarity ( p = 0.0001). There were no significant differences between DIMS and any test for other subjective ratings ( p > 0.07), nor willingness‐to‐purchase based on vision ( p > 0.2) or myopia management efficacy ( p > 0.6). Conclusions: Most of the test lenses achieved better VP through the treatment zone compared to the DIMS control. T2 showed better overall VP compared to DIMS, whereas DIMS showed better overall VP compared to T1.

  • Open Access

    Effect of cylinder power and axis changes on vision in astigmatic participants

    by J Sha, C Fedtke, D Tilia, N Yeotikar, M Jong, J Diec, V Thomas, Rc Bakaraju

    Purpose: To ascertain the impact of altering cylinder (cyl) power and axis on vision in astigmatism. Methods: In a prospective, randomized, participant-masked, crossover clinical trial, 28 astigmatic participants were tested for the following conditions on different days: full sphero-cyl correction and undercorrection by 0.25, 0.50, and 0.75 DC while maintaining spherical equivalence. Axis was also misaligned between –30° and +30°, in 10° steps. For each configuration, monocular high- and low-contrast visual acuities (HCVA, LCVA) were measured at 6 m, and participants rated vision clarity (1–10), vision satisfaction (1–10), and vision acceptability (yes/no). Linear mixed models were used to compare visual performance in the overall group and in low, medium, and high cyl subgroups. Results: Undercorrecting cyl power affected all groups equally (P≥0.073). Undercorrection by 0.75 DC was significantly different to full cyl power for all variables (P≤0.007), while 0.25 DC undercorrection did not cause any significant decreases (P>0.05). Undercorrection by 0.50 DC was significantly different to full cyl power for HCVA (P=0.006, however not clinically significant) and vision acceptability (P=0.034). Axis misalignment affected the cyl groups differently (PP≤0.003), while misalignments by ±10° or ±20° caused significant decreases for some cyl groups and test variables. Conclusion: Undercorrection of cyl by ≤0.50 DC while maintaining spherical equivalence has no significant effect on HCVA, LCVA, vision clarity, and vision satisfaction, while the amount of axis misalignment that can be tolerated is dependent on the cyl power. These results may have practical ophthalmic applications, such as reducing the total number of stock keeping units of toric contact lenses.


  • Open Access

    Visual performance of myopia control soft contact lenses in non-presbyopic myopes

    by Jennifer Sha, Daniel Tilia, Jennie Diec, Cathleen Fedtke, Nisha Yeotikar, Monica Jong, Varghese Thomas, Ravi C Bakaraju

    Purpose: To compare the visual performance of soft contact lenses reported to reduce myopia progression. Methods: In a double-blind, randomized, crossover trial, 30 non-presbyopic myopes wore MiSight™, center-distance Proclear® Multifocal (+2.00 D add), and two prototype lenses for 1 week each. High- and low-contrast visual acuities at 6 m, and 70 and 40 cm; stereopsis at 40 cm; accommodative facility at 33 cm; and horizontal phoria at 3 m and 33 cm were measured after 1 week. Subjective performance was assessed on a numeric rating scale for vision clarity, lack of ghosting, vision stability, haloes, overall vision satisfaction, and ocular comfort. Frequency of eye-strain symptoms and willingness to purchase lenses were also reported with categorical responses. Participants reported wearing times (total and visually acceptable). Linear mixed models and chi-square tests were employed in analysis with level of significance set at 5%. Theoretical optical performance of all lenses was assessed with schematic myopic model eyes (−1.00, −3.00, and −6.00 D) by comparing the slope of the edge spread function (ESF), an indicator for optical performance/resolution and the blur patch size of the line spread function, an indicator for contrast, between the lenses. Results: Proclear Multifocal and MiSight provided the best distance acuities. However, the prototype lenses were rated significantly higher for many subjective variables, and there were no subjective variables where commercial lenses were rated significantly higher than the prototypes. Theoretical optical performance showed steeper slopes of the ESF and greater blur patch sizes of the LSP with commercial lenses, supporting the clinical findings of better visual acuities but reduced subjective performance. Participants wore prototypes longer and reported their vision acceptable for longer each day compared to MiSight. Both prototypes had the highest willingness-to-purchase rate. Conclusions: The prototypes were better tolerated by myopes compared to the commercial soft contact lenses currently used for slowing myopia progression.


  • Open Access

    Effects of relative negative spherical aberration in single vision contact lens visual performance

    by Danny Kho, Cathleen Fedtke, Daniel Tilia, Jennie Diec, Jennifer Sha, Varghese Thomas, Ravi C Bakaraju

    Objective: The study aimed to compare the visual performance of contact lenses with and without negative spherical aberration (SA) over 5 days of wear. Methods: At baseline, 32 myopic participants (aged 18–33 years) were fitted in a randomized order with two lenses (test lens with minimal or no SA and 1-Day Acuvue Moist designed with negative SA) for 5 days (minimum 6 hours wear/day). Participants returned for a follow-up visit. This consisted of on-axis SA measurements; high- and low-contrast visual acuities at 6 m; high-contrast acuities at 70 and 40 cm; low-illumination, low-contrast acuity at 6 m; stereopsis at 40 cm; horizontal phorias at 3 m and 33 cm; and ±2.00 D monocular accommodative facility at 33 cm. Participants also rated (1–10 scale) vision quality (clarity and lack of ghosting for distance, intermediate, near, driving vision and vision stability during day- and night-time), overall vision satisfaction, ocular comfort, and willingness to purchase (yes/no response). Results: 1-Day Acuvue Moist induced significantly (p0.05) in acuity, binocular vision, and all subjective metrics except vision stability between lenses where the test lens was rated to provide more stable vision (p Conclusion: Contrary to expectations, incorporating negative SA in single vision soft contact lenses did not improve visual performance in non-presbyopic adult myopes.