SMStephanie Mellor

Stephanie Mellor

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Stephanie Mellor has a total of 106 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Robustness of cortical distortion metrics to unmodelled OPM errors

    by Alberto Mariola, Stephanie Mellor, James J. Bonaiuto, Tim M. Tierney, John Ashburner, Yaël Balbastre, José David López, Gareth R. Barnes

    The estimate of cortical current flow from magnetic fields measured outside the head is an ill-posed problem. Recent work using head casts to minimise co-registration errors in conventional cryogenic magnetoencephalography (MEG) has shown that ground truth anatomy can be used to judge between different inversion schemes and metrics. Inversion algorithms or metrics that are insensitive to anatomical distortion are unlikely to reflect correct assumptions about the underlying current distribution. Here we aim to identify constraints when using this approach to validate current flow estimated from recordings made with optically pumped MEG (OP-MEG). To do so, we used simulations contaminated by different sources of (typically unmodelled) error. For example: error in the estimate of the true sensor positions or orientations and the effects of unmodelled gain changes. In accordance with previous work, with no unmodelled errors, distortion was minimized when the simulation and the inversion assumptions matched. We then quantified the amount of error (in mm) relative to the true cortical mesh that one might expect in empirical recordings (given gain, position and orientation errors). We found that the approach was tolerant to independent sensor position errors of less than 2 mm (per axis); orientation errors of less than 5 degrees; fixed array displacements of less than 10 degrees and to random sensor gain errors of less than 10%. Additionally, we tested this approach using two empirical OPM datasets. We found that source reconstructions based on both minimum norm and beamformer assumptions were sensitive to the underlying anatomy.

  • Open Access

    Auditory evoked responses during ambulatory OP-MEG

    by Stephanie Mellor, Tim M. Tierney, James Osborne, Meaghan E. Spedden, Robert A. Seymour, Nicholas A. Alexander, Cody Doyle, David Bobela, George C. O’NEill, Katarzyna Rudzka, et al.

    The latest generation of optically pumped magnetometer (OPM)-based magnetoencephalography (OP-MEG) systems are increasingly portable and lightweight, making the system easier to wear while undertaking large, whole-body translational and rotational movements. We recorded OP-MEG from three participants during auditory stimulation, while the participants walked around a magnetically shielded room, moving across an area of at least 1.7 m2 and rotating by at least 180 degrees. All sensor-specific electronics were housed within a wearable backpack, minimising movement restrictions which would otherwise be imposed by sensor cabling. In this experiment, the maximum peak-to-peak range of the observed magnetic field recorded on a single channel was 25.2 nT, considerably beyond the approximately 4 nT range of many previous OP-MEG systems. We show that adaptive multipole modelling (AMM) with the temporal extension can be used to separate the interference and neuromagnetic signals, despite the large degree of movement and proximity of the sensor electronics. We observed significant auditory evoked responses at the sensor level, without the need for source localisation approaches for interference suppression. These findings demonstrate the capability of OP-MEG for conducting naturalistic experiments involving movement and for recordings with paediatric and clinical cohorts who cannot remain still.

  • Open Access

    Perceived Control Over Breathing Perturbations Depends on Interosensory Input and Prediction Error

    by Alexander J. Hess, Giulia Cornali, Stephanie Mellor, László Demkó, Laura Köchli, Chiara Bassi, Alexandra Kalberer, Stephanie Marino, Christoph Mathys, Stefan Frässle, et al.

    Interoception and homeostatic/allostatic control are not only fundamental for survival but play a key role for maintaining somatic and mental health. Furthermore, metacognitive evaluations of these processes, such as perceived failure of allostatic regulation, have been proposed to underlie the experience of chronic symptoms, such as chronic fatigue. A central question in this regard is what mechanisms the brain uses to evaluate control over bodily states. A prominent computational proposal posits that this is achieved by monitoring of interoceptive prediction errors (PEs). However, to date, this proposal has not been tested experimentally. Here, we tested this hypothesis by applying computational process models of perceived control to data from a novel behavioural paradigm, the Respiratory Metacognition of Control Task (RMCT). The RMCT manipulates control over breathing by changing inspiratory resistive loads as a function of control achieved in a gamified prediction task. We developed and compared trial-by-trial generative models of perceived explicit control in the RMCT, using data from 50 volunteers in a pre-registered analysis. Bayesian model selection suggested that perceived control over breathing is best explained as a function of both trial-wise interoceptive outcomes (breathing with or without an inspiratory resistive load) and trial-wise PEs about respiratory resistance. These results support a longstanding computational proposal of how the brain detects failures of bodily regulation and provide a mechanistic model for understanding inter-individual differences in perceived control over bodily states.

  • Experiences of ictal OP-MEG

    by Stephanie Mellor, George C. O’NEill, Daniel Bush, Arjun Ramaswamy, Ryan C. Timms, David Doig, Tim M. Tierney, Meaghan E. Spedden, Matthew C. Walker, Gareth R. Barnes, et al.


  • Open Access

    Using Wearable MEG to Study the Neural Control of Human Stepping

    by Meaghan E. Spedden, George C. O’neill, Timothy O. West, Tim M. Tierney, Stephanie Mellor, Nicholas A. Alexander, Robert Seymour, Jesper Lundbye-Jensen, Jens Bo Nielsen, Simon F. Farmer, et al.

    A central challenge in movement neuroscience is developing methods for non-invasive spatiotemporal imaging of brain activity during natural, whole-body movement. We test the utility of a new brain imaging modality, optically pumped magnetoencephalography (OP-MEG), as an instrument to study the spatiotemporal dynamics of human walking. Specifically, we ask whether known physiological signals can be recovered during discrete steps involving large-scale, whole-body translation. Our findings show that by using OP-MEG, we can image the brain during large-scale, natural movements. We provide proof-of-principle evidence for movement-related changes in beta band activity during stepping vs. standing, which are source-localized to the sensorimotor cortex. This work supports the significant potential of the OP-MEG modality for addressing fundamental questions in human gait research relevant to both the physiological and pathological mechanisms of walking.


  • Top Cited Papers
    Open Access

    SPM 25: open source neuroimaging analysis software

    by Tim M. Tierney, Nicholas A. Alexander, John Ashburner, Nicole Labra Avila, Yaël Balbastre, Gareth Barnes, Yulia Bezsudnova, Mikael Brudfors, Korbinian Eckstein, Guillaume Flandin, et al.

    Statistical Parametric Mapping (SPM) is an integrated set of methods for testing hypotheses about the brain's structure and function, using data from imaging devices. These methods are implemented in an open source software package, SPM, which has been in continuous development for more than 30 years by an international community of developers. This paper reports the release of SPM 25.01, a major new version of the software that incorporates novel analysis methods, optimisations of existing methods, as well as improved practices for open science and software development.


  • Open Access

    Wearable MEG data recorded during human stepping

    by Meaghan E. Spedden, George C. O’nEill, Timothy O. West, Tim M. Tierney, Stephanie Mellor, Nicholas A. Alexander, Robert Seymour, Jesper Lundbye-Jensen, Jens Bo Nielsen, Simon F. Farmer, et al.


  • Open Access

    Anatomically Veridical On‐Scalp Sensor Topographies

    by Nicholas A. Alexander, Johan Medrano, Robert A. Seymour, Stephanie Mellor, George C. O’nEill, Meaghan E. Spedden, Tim M. Tierney, Eleanor A. Maguire

    When working with sensor‐level data recorded using on‐scalp neuroimaging methods such as electroencephalography (EEG), it is common practice to use two‐dimensional (2D) representations of sensor positions to aid interpretation. Positioning of sensors relative to anatomy, as in the classic 10–20 system of EEG electrode placement, enables the use of 2D topographies that are familiar to many researchers and clinicians. However, when using another increasingly popular on‐scalp neuroimaging method, optically pumped magnetometer–based magnetoencephalography (OP‐MEG), bespoke sensor arrays are much more common, and these are not prepared according to any standard principle. Consequently, polar projection is often used to produce individual sensor topographies that are not directly related to anatomy and cannot be averaged across people simply. Given the current proliferation of OP‐MEG facilities globally, this issue will become an increasing hindrance when visualising OP‐MEG data, particularly for group studies. To address this problem, we adapted and extended the 10–20 system to build a flexible, anatomical projection method applied to digitised head shape, fiducials and sensor positions. We demonstrate that the method maintains spatially veridical representations across individuals improving on standard polar projections at varying OPM sensor array densities. By applying our projection method, the benefits of anatomically veridical 2D topographies can now be enjoyed when visualising data, such as those from OP‐MEG, regardless of variation in sensor placement as in sparse or focal arrays.


  • Open Access

    Wearable MEG data recorded during human stepping

    by Meaghan Elizabeth Spedden, George C. O’NEill, Timothy O. West, Tim M. Tierney, Stephanie J Mellor, Nicholas A. Alexander, Robert Seymour, Jesper Lundbye-Jensen, Jens Bo Nielsen, Simon F. Farmer, et al.

    Non-invasive spatiotemporal imaging of brain activity during large-scale, whole body movement is a significant methodological challenge for the field of movement neuroscience. Here, we present a dataset recorded using a new imaging modality – optically-pumped magnetoencephalography (OP-MEG) – to record brain activity during human stepping. Participants ( n =3) performed a visually guided stepping task requiring precise foot placement while dual-axis and triaxial OP-MEG and leg muscle activity (electromyography, EMG) were recorded. The dataset also includes a structural MRI for each participant and foot kinematics. We validate the fidelity of the OPM data by showing movement-related beta band desynchronization source localised to the primary motor cortex. This multimodal dataset offers a resource for methodological development and testing for OPM data (e.g., movement-related interference rejection), within-subject analyses, and exploratory analyses to generate hypotheses for further work on the neural control of human stepping.


  • Open Access

    Test-retest reliability of auditory MMN measured with OPM-MEG

    by Laszlo Demko, Sandra Iglesias, Stephanie Mellor, Katja Brand, Alexandra Kalberer, Laura Köchli, Stephanie Marino, Noé Zimmermann, Jakob Heinzle, Klaas Enno Stephan

    In this paper, we report results from an investigation of auditory mismatch responses as measured by magnetoencephalography (MEG) based on optically pumped magnetometers (OPM). Specifically, as part of a quality control study, we examined the reliability and validity of auditory mismatch negativity (MMN) recordings, obtained with a newly installed OPM-MEG system. Based on OPM-MEG data from 30 healthy volunteers, measured twice with an established auditory MMN paradigm with frequency deviants, we examined the following questions: First, we focused on construct validity and examined whether OPM-MEG measurements of MMN responses (in terms of event-related fields, ERFs) were qualitatively comparable to previous MMN findings from studies using EEG or MEG based on superconducting quantum interference devices (SQUIDs). In particular, we examined whether significant MMN responses measured by OPM-MEG occurred in a comparable time window and showed a similar topography as in previous EEG/MEG studies of MMN. Second, we quantified test-retest reliability of MMN amplitude and latency over two separate measurement sessions. The results of our analyses show that MMN responses recorded with OPM-MEG are in good agreement with previously reported MMN results in terms of timing and topography. Furthermore, the comparison of group-level MMN topographies and timeseries shows excellent consistency across the two measurement sessions. Our quantitative test-retest reliability analyses at the sensor level indicate good reliability for MMN amplitude, but poor reliability for MMN latency. Overall, our findings suggest that OPM-MEG measurements of auditory MMN (i) are comparable to results from EEG and SQUID-based MEG and (ii) show good test-retest reliability for amplitude measures at the sensor level. Notably, these results were achieved in an “out of the box” state of the OPM-MEG system, shortly after installation and without further optimisation. The reason for the insufficient reliability for MMN latency we observed is currently under investigation and represents an important target for future improvements.