Edward Lisowski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Edward Lisowski has a total of 141 co-authors. Here are the top co-authors by number of shared publications:
- Grzegorz Filo
Faculty of Mechanical Engineering, Cracow University of Technology, 31-864 Cracow, Poland
17 shared publications - Filip Lisowski
Faculty of Mechanical Engineering, Cracow University of Technology, Warszawska 24, Kraków, 31-155, Poland
14 shared publications - Janusz Rajda
Ponar Wadowice S.A.
9 shared publications - Eryk Czerwinski
Jagiellonian University
7 shared publications - Manish Das
Jagiellonian University
7 shared publications - Catalina Curceanu
Laboratori Nazionali di Frascati, INFN, Frascati, Italy
6 shared publications
Latest Publications
- Open Access
- 6 June 2026
- Published by Elsevier in Physics Letters B
- Vol. 879
First direct determination of the pick-off contribution to the ortho-positronium decay rate
- 6 June 2026
- Published by Elsevier in Physics Letters B
- Vol. 879
Open AccessFirst direct determination of the pick-off contribution to the ortho-positronium decay rate
- Open Access
- 13 April 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (7) , 075026
Monte Carlo-based scatter correction for the plastic-based modular PET scanner J-PET
Objective. This work presents and evaluates a Monte Carlo (MC) -based scatter correction (SC) method developed for the Jagiellonian positron emission tomography (J-PET) scanner, a modular PET system based on plastic scintillators. Approach. The algorithm employs SimSET-based simulations integrated into a time-of-flight ordered-subsets expectation maximization reconstruction framework to estimate scatter contributions. Phantom studies using the NEMA image quality (IQ) phantom and a proof-of-principle human subject scan with the J-PET scanner were analyzed. To accelerate computation, lutetium–yttrium oxyorthosilicate (LYSO) crystals were also assessed in simulations as a surrogate for the native plastic material BC-404. Main results. In phantom experiments, SC improved contrast recovery coefficients by over 20% and reduced background variability by 8.5%, without introducing significant noise. Residual activity in cold regions was also considerably reduced. Substituting LYSO in the simulations decreased runtime by nearly one order of magnitude, while maintaining deviations below 6% in IQ metrics compared to BC-404. Human subject data demonstrated qualitatively reduced residual scatter and improved organ delineation. Quantitative comparison with the commercial PET/CT scanner by General Electric HealthCare (GE) discovery MI Gen 2 showed consistent activity concentration ratios across organs, although higher noise and residual scatter between organs were observed in J-PET, which most likely originates from lower count density. Significance. The proposed MC-based SC method provides robust scatter removal for J-PET, improving quantitative performance and establishing a foundation for advanced correction and reconstruction techniques. These results bring the plastic scintillator-based J-PET scanner closer to enabling clinically relevant quantitative PET imaging.
- 13 April 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (7) , 075026
Open AccessMonte Carlo-based scatter correction for the plastic-based modular PET scanner J-PET
Objective. This work presents and evaluates a Monte Carlo (MC) -based scatter correction (SC) method developed for the Jagiellonian positron emission tomography (J-PET) scanner, a modular PET system based on plastic scintillators. Approach. The algorithm employs SimSET-based simulations integrated into a time-of-flight ordered-subsets expectation maximization reconstruction framework to estimate scatter contributions. Phantom studies using the NEMA image quality (IQ) phantom and a proof-of-principle human subject scan with the J-PET scanner were analyzed. To accelerate computation, lutetium–yttrium oxyorthosilicate (LYSO) crystals were also assessed in simulations as a surrogate for the native plastic material BC-404. Main results. In phantom experiments, SC improved contrast recovery coefficients by over 20% and reduced background variability by 8.5%, without introducing significant noise. Residual activity in cold regions was also considerably reduced. Substituting LYSO in the simulations decreased runtime by nearly one order of magnitude, while maintaining deviations below 6% in IQ metrics compared to BC-404. Human subject data demonstrated qualitatively reduced residual scatter and improved organ delineation. Quantitative comparison with the commercial PET/CT scanner by General Electric HealthCare (GE) discovery MI Gen 2 showed consistent activity concentration ratios across organs, although higher noise and residual scatter between organs were observed in J-PET, which most likely originates from lower count density. Significance. The proposed MC-based SC method provides robust scatter removal for J-PET, improving quantitative performance and establishing a foundation for advanced correction and reconstruction techniques. These results bring the plastic scintillator-based J-PET scanner closer to enabling clinically relevant quantitative PET imaging.
- Open Access
- 4 February 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (3)
Studies of C P T symmetry in positronium decays with the 192 plastic strip J-PET detector
A direct test of the C P T symmetry is performed for the electromagnetic decays of ortho-positronium using the Jagiellonian positron emission tomograph (J-PET). We present the precise measurement of the C P T -sensitive angular correlation entailing the positronium spin and the momenta of its annihilation photons, surpassing previous studies utilizing the same detection system. Positrons originating from a Na 22 source are emitted from the detector’s center and subsequently form positronium atoms within the spherical chamber covered with porous material. Reconstruction of annihilation locations using the 192-strip J-PET detector makes it possible to determine the positronium emission direction, which defines the quantization axis along which positronium is polarized, without the application of external magnetic fields. The measurements were performed in total for 356 days resulting in an identification of 47.8 × 10 6 events with ortho-positronium decays into three photons. The results are consistent with the exactness of C P T symmetry with measured asymmetry amplitude − 0.00029 ± 0.00022 (stat.) and with statistical error four times smaller than the previous best measurement.
- 4 February 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (3)
Open AccessStudies of C P T symmetry in positronium decays with the 192 plastic strip J-PET detector
A direct test of the C P T symmetry is performed for the electromagnetic decays of ortho-positronium using the Jagiellonian positron emission tomograph (J-PET). We present the precise measurement of the C P T -sensitive angular correlation entailing the positronium spin and the momenta of its annihilation photons, surpassing previous studies utilizing the same detection system. Positrons originating from a Na 22 source are emitted from the detector’s center and subsequently form positronium atoms within the spherical chamber covered with porous material. Reconstruction of annihilation locations using the 192-strip J-PET detector makes it possible to determine the positronium emission direction, which defines the quantization axis along which positronium is polarized, without the application of external magnetic fields. The measurements were performed in total for 356 days resulting in an identification of 47.8 × 10 6 events with ortho-positronium decays into three photons. The results are consistent with the exactness of C P T symmetry with measured asymmetry amplitude − 0.00029 ± 0.00022 (stat.) and with statistical error four times smaller than the previous best measurement.
- Open Access
- 24 January 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1086
Nanoporosity imaging by positronium lifetime tomography
- 24 January 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1086
Open AccessNanoporosity imaging by positronium lifetime tomography
- 18 October 2025
- Published by Springer Nature
- p. 76-85
Analysis of a Hydraulic System Flow Rate Measurement Accuracy Using Low-Cost Flowmeters
- 18 October 2025
- Published by Springer Nature
- p. 76-85
Analysis of a Hydraulic System Flow Rate Measurement Accuracy Using Low-Cost Flowmeters
- 18 October 2025
- Published by Springer Nature
- p. 45-55
Analysis of a Control Valve Flow Resistance in the Application of Switching the Hydraulic Motor Circuits
- 18 October 2025
- Published by Springer Nature
- p. 45-55
Analysis of a Control Valve Flow Resistance in the Application of Switching the Hydraulic Motor Circuits
- Open Access
- 6 October 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (19) , 10747
Modelling a Fuzzy Logic-Based Multiple-Actuator Hydraulic Lifting and Positioning System
This paper presents a fuzzy logic control strategy for synchronising the vertical lifting and positioning of a multi-actuator hydraulic system designed for a 360-ton movable platform. The primary focus is on achieving precise actuator movement coordination under uneven loading conditions without using external reference systems or high-cost sensors. A mathematical model and a simulation environment were developed in MATLAB/Simulink with Fuzzy Logic Toolbox. Four fuzzy controller variants were evaluated regarding positioning accuracy, robustness, and compliance with dynamic constraints. The results demonstrate the effectiveness of the proposed control method, particularly when using Gaussian membership functions and PROD–PROBOR fuzzy operators. The system achieved sub-millimetre synchronisation accuracy even under 20% load imbalance. This work contributes to developing decentralised, sensor-light control strategies for large-scale hydraulic systems and offers a validated foundation for future experimental implementation in the PANDA particle detector project.
- 6 October 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (19) , 10747
Open AccessModelling a Fuzzy Logic-Based Multiple-Actuator Hydraulic Lifting and Positioning System
This paper presents a fuzzy logic control strategy for synchronising the vertical lifting and positioning of a multi-actuator hydraulic system designed for a 360-ton movable platform. The primary focus is on achieving precise actuator movement coordination under uneven loading conditions without using external reference systems or high-cost sensors. A mathematical model and a simulation environment were developed in MATLAB/Simulink with Fuzzy Logic Toolbox. Four fuzzy controller variants were evaluated regarding positioning accuracy, robustness, and compliance with dynamic constraints. The results demonstrate the effectiveness of the proposed control method, particularly when using Gaussian membership functions and PROD–PROBOR fuzzy operators. The system achieved sub-millimetre synchronisation accuracy even under 20% load imbalance. This work contributes to developing decentralised, sensor-light control strategies for large-scale hydraulic systems and offers a validated foundation for future experimental implementation in the PANDA particle detector project.
- Open Access
μPPET: Investigating the Muon Puzzle with J-PET Detectors
The PPET [mu()on Probe with J-PET] project aims to investigate the “Muon Puzzle” seen in cosmic ray air showers. This puzzle arises from the observation of a significantly larger number of muons on Earth’s surface than that predicted by the current theoretical models. The investigated hypothesis is based on recently observed asymmetries in the parameters for the strong interaction cross-section and trajectory of an outgoing particle due to projectile–target polarization. The measurements require detailed information about muons at the ground level, including their track and charge distributions. To achieve this, the two PET scanners developed at the Jagiellonian University in Krakow (Poland), the J-PET detectors, will be employed, taking advantage of their well-known resolution and convenient location for detecting muons that reach long depths in the atmosphere. One station will be used as a muon tracker, while the second will reconstruct the core of the air shower. In parallel, the existing hadronic interaction models will be modified and fine-tuned based on the experimental results. In this work, we present the conceptualization and preliminary designs of PPET.Open AccessμPPET: Investigating the Muon Puzzle with J-PET Detectors
The PPET [mu()on Probe with J-PET] project aims to investigate the “Muon Puzzle” seen in cosmic ray air showers. This puzzle arises from the observation of a significantly larger number of muons on Earth’s surface than that predicted by the current theoretical models. The investigated hypothesis is based on recently observed asymmetries in the parameters for the strong interaction cross-section and trajectory of an outgoing particle due to projectile–target polarization. The measurements require detailed information about muons at the ground level, including their track and charge distributions. To achieve this, the two PET scanners developed at the Jagiellonian University in Krakow (Poland), the J-PET detectors, will be employed, taking advantage of their well-known resolution and convenient location for detecting muons that reach long depths in the atmosphere. One station will be used as a muon tracker, while the second will reconstruct the core of the air shower. In parallel, the existing hadronic interaction models will be modified and fine-tuned based on the experimental results. In this work, we present the conceptualization and preliminary designs of PPET. - Top Cited PapersOpen Access
- 2 May 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (18) , eads3046
Nonmaximal entanglement of photons from positron-electron annihilation demonstrated using a plastic PET scanner
In state-of-the-art positron emission tomography (PET), information about annihilation photon polarization is unavailable. Here, we present a PET scanner built from plastic scintillators, where annihilation photons primarily interact via the Compton effect, providing information about both photon polarization and propagation direction. Using this plastic-based PET, we determined the distribution of the relative angle between polarization planes of photons from positron-electron annihilation in a porous polymer. The amplitude of the observed distribution is smaller than predicted for maximally quantum entangled two-photon states but larger than expected for separable photons. This result can be well explained by assuming that photons from pick-off annihilation are not entangled, while photons from direct and parapositronium annihilations are maximally entangled. Our result indicates that the degree of entanglement depends on the annihilation mechanism in matter, opening avenues for exploring polarization correlations in PET as a diagnostic indicator.
- 2 May 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (18) , eads3046
Top Cited PapersOpen AccessNonmaximal entanglement of photons from positron-electron annihilation demonstrated using a plastic PET scanner
In state-of-the-art positron emission tomography (PET), information about annihilation photon polarization is unavailable. Here, we present a PET scanner built from plastic scintillators, where annihilation photons primarily interact via the Compton effect, providing information about both photon polarization and propagation direction. Using this plastic-based PET, we determined the distribution of the relative angle between polarization planes of photons from positron-electron annihilation in a porous polymer. The amplitude of the observed distribution is smaller than predicted for maximally quantum entangled two-photon states but larger than expected for separable photons. This result can be well explained by assuming that photons from pick-off annihilation are not entangled, while photons from direct and parapositronium annihilations are maximally entangled. Our result indicates that the degree of entanglement depends on the annihilation mechanism in matter, opening avenues for exploring polarization correlations in PET as a diagnostic indicator.
- 23 December 2024
- Published by Index Copernicus in Bio-Algorithms and Med-Systems
- Vol. 20 (1) , 101-110
Development of correction techniques for the J-PET scanner
Objective: Positron emission tomography (PET) is a widely used medical imaging technique that allows for non-invasive imaging of metabolic processes. However, traditional PET scanners rely on costly inorganic scintillators that limit their accessibility, especially in light of emerging long axial field-of-view devices. The modular J-PET scanner, an innovative alternative, uses 50-cm-long plastic scintillator strips, offering a cost-effective and modular solution. In this study we develop and assess the PET data correction techniques required for quantitative image reconstruction. Methods: We present methods for attenuation correction, random coincidence correction using the delayed time window (DTW) technique and scatter correction based on Monte Carlo simulations. Phantom studies using the NEMA IQ phantom were performed to qualitatively evaluate these corrections. Results: The results demonstrate that our implemented corrections for attenuation and random and scattered coincidences successfully improve the uniformity of tracer distribution in homogenous volumes and significantly reduce undesired activity in cold regions. Despite limitations in sensitivity and axial resolution, the applied correction techniques effectively enhance image quality, providing promising results for future applications. Conclusions: These findings highlight the potential of the modular J-PET system to offer affordable PET imaging and to pave the way for a total-body PET scanner based on plastic scintillators. Future work will focus on quantitative validation and the implementation of these corrections for human subject imaging.
- 23 December 2024
- Published by Index Copernicus in Bio-Algorithms and Med-Systems
- Vol. 20 (1) , 101-110
Development of correction techniques for the J-PET scanner
Objective: Positron emission tomography (PET) is a widely used medical imaging technique that allows for non-invasive imaging of metabolic processes. However, traditional PET scanners rely on costly inorganic scintillators that limit their accessibility, especially in light of emerging long axial field-of-view devices. The modular J-PET scanner, an innovative alternative, uses 50-cm-long plastic scintillator strips, offering a cost-effective and modular solution. In this study we develop and assess the PET data correction techniques required for quantitative image reconstruction. Methods: We present methods for attenuation correction, random coincidence correction using the delayed time window (DTW) technique and scatter correction based on Monte Carlo simulations. Phantom studies using the NEMA IQ phantom were performed to qualitatively evaluate these corrections. Results: The results demonstrate that our implemented corrections for attenuation and random and scattered coincidences successfully improve the uniformity of tracer distribution in homogenous volumes and significantly reduce undesired activity in cold regions. Despite limitations in sensitivity and axial resolution, the applied correction techniques effectively enhance image quality, providing promising results for future applications. Conclusions: These findings highlight the potential of the modular J-PET system to offer affordable PET imaging and to pave the way for a total-body PET scanner based on plastic scintillators. Future work will focus on quantitative validation and the implementation of these corrections for human subject imaging.