Yapeng Zhang
Research Subjects
Yapeng Zhang has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Xiaoping Ouyang
School of Physics and Astronomy, Beijing Normal University 4 , Beijing 100875
3 shared publications - Fangbao Wang
National Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Pingyu Road 28th, Xi'an, 710024, China
2 shared publications - Jinlu Ruan
National Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Pingyu Road 28th, Xi'an, 710024, China
2 shared publications - Liang Chen
Radiation Detection Research Center, Northwest Institute of Nuclear Technology 3 , Xi'an 710024
2 shared publications Naizhe Zhao
National Key Laboratory of Intense Pulsed Radiation Environment Simulation and Effect, Northwest Institute of Nuclear Technology 2 , Xi’an 710024
2 shared publications- Silong Zhang
School of Materials Science and Engineering, Xiangtan University 3 , Xiangtan 411105
2 shared publications
Latest Publications
- 1 September 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (9)
A neutron spectrometer based on recoil proton track imaging for high-yield inertial confinement fusion primary deuterium–tritium neutrons
The energy spectra of primary deuterium–tritium (DT) neutrons provide essential information about the implosion performance in inertial confinement fusion (ICF) experiments. Recoil proton track imaging is a recently developed technique for measuring neutron energy spectra, which optically records the track image of recoil protons in a gas scintillator using high-performance imaging devices, then derives the neutron spectrum through an unfolding procedure. Here, focusing on the ICF primary DT neutrons with a yield of up to 1019, we design a neutron spectrometer based on this method. Considering the trade-off between energy resolution and detection efficiency, we optimize key system parameters, including recoil angle, recoil proton flight distance, aperture size, polyethylene foil thickness, and gas scintillator pressure through simulation, achieving a recoil proton conversion efficiency of 8.68×10−7 for 14.1 MeV neutrons. In addition, since the high-precision spectrum unfolding requires a high-quality track image, we specially design a large-aperture fixed-focus lens to enhance the efficiency of scintillation photon collection. Furthermore, we propose a realistic track image simulation method that combines Monte Carlo simulation with optical imaging simulation, allowing for a more accurate calculation of the neutron energy response. Based on the designed system, we simulate track images for mono-energetic neutrons, neutrons with spectra from National Ignition Facility ignition experiments, and neutrons with a Gaussian spectrum. The results demonstrate that high-quality track images can be obtained under the designed system. Subsequently, the spectrum unfolding for simulated track images corresponding to energy spectra is performed using MLEM and GRAVEL algorithms. The high quality of the unfolded spectra indicates that the recoil proton track imaging is a promising approach for diagnosing ICF primary DT neutron spectra.
- 1 September 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (9)
A neutron spectrometer based on recoil proton track imaging for high-yield inertial confinement fusion primary deuterium–tritium neutrons
The energy spectra of primary deuterium–tritium (DT) neutrons provide essential information about the implosion performance in inertial confinement fusion (ICF) experiments. Recoil proton track imaging is a recently developed technique for measuring neutron energy spectra, which optically records the track image of recoil protons in a gas scintillator using high-performance imaging devices, then derives the neutron spectrum through an unfolding procedure. Here, focusing on the ICF primary DT neutrons with a yield of up to 1019, we design a neutron spectrometer based on this method. Considering the trade-off between energy resolution and detection efficiency, we optimize key system parameters, including recoil angle, recoil proton flight distance, aperture size, polyethylene foil thickness, and gas scintillator pressure through simulation, achieving a recoil proton conversion efficiency of 8.68×10−7 for 14.1 MeV neutrons. In addition, since the high-precision spectrum unfolding requires a high-quality track image, we specially design a large-aperture fixed-focus lens to enhance the efficiency of scintillation photon collection. Furthermore, we propose a realistic track image simulation method that combines Monte Carlo simulation with optical imaging simulation, allowing for a more accurate calculation of the neutron energy response. Based on the designed system, we simulate track images for mono-energetic neutrons, neutrons with spectra from National Ignition Facility ignition experiments, and neutrons with a Gaussian spectrum. The results demonstrate that high-quality track images can be obtained under the designed system. Subsequently, the spectrum unfolding for simulated track images corresponding to energy spectra is performed using MLEM and GRAVEL algorithms. The high quality of the unfolded spectra indicates that the recoil proton track imaging is a promising approach for diagnosing ICF primary DT neutron spectra.
- 1 May 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (05) , P05023
Simulation and experiment study of performances of the hybrid photomultiplier tube based on a SiC detector
Because of its advantages such as large maximum linear current, fast time response and radiation resistance, the hybrid photomultiplier tube based on a SiC detector (SiC-HPMT) is expected to become an important photon detector for the scintillation detectors used in measuring intense pulsed radiation fields. The performance of the SiC-HPMT is dependent on the electron transport process and properties of the SiC detector. The properties of the SiC detector have been studied in detail. However, how the electron transport process affects the performance of the SiC-HPMT is still unclear. Therefore, the influence of the electron transport process on the performance of the SiC-HPMT was simulated by the CST software. According to the simulation results, the leading edge, the trailing edge and the full width at half maximum of the electron transport time are only 0.24 ns, less than 1.5 ns and less than 1 ns, respectively, which is significantly smaller than the temporal response of the SiC detector. Therefore, the temporal response of the SiC-HPMT is mainly determined by the SiC detector. Moreover, the maximum linear current (MLC) of the SiC-HPMT can be significantly improved by adjusting the distribution of the electric field. The variation trend obtained from experiments is consistent with simulations. The experimental result indicated that the MLC is larger than 1 A. This study provides important theoretical guidance for optimizing the performance of the SiC-HPMT, which can make the SiC-HPMT more advantageous in applications for measuring pulsed radiation fields.
- 1 May 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (05) , P05023
Simulation and experiment study of performances of the hybrid photomultiplier tube based on a SiC detector
Because of its advantages such as large maximum linear current, fast time response and radiation resistance, the hybrid photomultiplier tube based on a SiC detector (SiC-HPMT) is expected to become an important photon detector for the scintillation detectors used in measuring intense pulsed radiation fields. The performance of the SiC-HPMT is dependent on the electron transport process and properties of the SiC detector. The properties of the SiC detector have been studied in detail. However, how the electron transport process affects the performance of the SiC-HPMT is still unclear. Therefore, the influence of the electron transport process on the performance of the SiC-HPMT was simulated by the CST software. According to the simulation results, the leading edge, the trailing edge and the full width at half maximum of the electron transport time are only 0.24 ns, less than 1.5 ns and less than 1 ns, respectively, which is significantly smaller than the temporal response of the SiC detector. Therefore, the temporal response of the SiC-HPMT is mainly determined by the SiC detector. Moreover, the maximum linear current (MLC) of the SiC-HPMT can be significantly improved by adjusting the distribution of the electric field. The variation trend obtained from experiments is consistent with simulations. The experimental result indicated that the MLC is larger than 1 A. This study provides important theoretical guidance for optimizing the performance of the SiC-HPMT, which can make the SiC-HPMT more advantageous in applications for measuring pulsed radiation fields.
- Open Access
- 1 December 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (12)
Measurement of relative neutron energy response curve of plastic scintillator detector based on the back-n-white neutron source at CSNS
The plastic scintillator detector is widely used to measure pulsed radiation fields, and a high-quality neutron energy response curve is crucial for accurately determining neutron yields. Traditionally, the neutron energy response curve can be obtained by the simulation of the performance of neutron detectors via the knowledge of the light yield of secondary particles or direct measuring energy response. Both methods record signals by a data acquisition system in the counting mode. This work establishes a new model to directly measure the energy response to neutrons of a plastic scintillator detector in current mode with white source spectra. The plastic scintillator detector can be triggered externally. There is no signal loss and dead time, and it is possible to calibrate the neutron detector with a high-intensity neutron source. Efficiencies can be determined at all energies simultaneously, and a rapid calibration of the plastic scintillator detector is available. To validate the experimental results, the theoretical values are obtained by Geant4 simulation, and the results reproduce the shapes of the experimental curves reasonably well. The neutron energy response curves of the detector show that when the thickness of the scintillator is reduced from 3 to 1 mm, the reduction ratio of gamma signal intensity is greater than that of neutron signal intensity, which leads to an increase in the neutron–gamma sensitivity ratio. Meanwhile, the thin scintillator thickness can obtain a somewhat flatter neutron energy response curve compared with other thicknesses.
- 1 December 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (12)
Open AccessMeasurement of relative neutron energy response curve of plastic scintillator detector based on the back-n-white neutron source at CSNS
The plastic scintillator detector is widely used to measure pulsed radiation fields, and a high-quality neutron energy response curve is crucial for accurately determining neutron yields. Traditionally, the neutron energy response curve can be obtained by the simulation of the performance of neutron detectors via the knowledge of the light yield of secondary particles or direct measuring energy response. Both methods record signals by a data acquisition system in the counting mode. This work establishes a new model to directly measure the energy response to neutrons of a plastic scintillator detector in current mode with white source spectra. The plastic scintillator detector can be triggered externally. There is no signal loss and dead time, and it is possible to calibrate the neutron detector with a high-intensity neutron source. Efficiencies can be determined at all energies simultaneously, and a rapid calibration of the plastic scintillator detector is available. To validate the experimental results, the theoretical values are obtained by Geant4 simulation, and the results reproduce the shapes of the experimental curves reasonably well. The neutron energy response curves of the detector show that when the thickness of the scintillator is reduced from 3 to 1 mm, the reduction ratio of gamma signal intensity is greater than that of neutron signal intensity, which leads to an increase in the neutron–gamma sensitivity ratio. Meanwhile, the thin scintillator thickness can obtain a somewhat flatter neutron energy response curve compared with other thicknesses.
- 6 November 2020
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 31 (11) , 1-13
Preliminary analysis of fuel cycle performance for a small modular heavy water-moderated thorium molten salt reactor
- 6 November 2020
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 31 (11) , 1-13
Preliminary analysis of fuel cycle performance for a small modular heavy water-moderated thorium molten salt reactor