NMNicole McFarlane

Nicole McFarlane

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nicole McFarlane has a total of 75 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Analysis of a Prototype Multi-Detector Fast-Neutron Radiography Panel

    by Christian X. Young, Chloe A. Browning, Ryan J. Thurber, Matthew R. Smalley, Michael J. Liesenfelt, Jason P. Hayward, Nicole McFarlane, Michael P. Cooper, Jeff R. Preston

    A multi-detector fast neutron radiography panel was built using the previous work on scalable neutron radiography using the IDEAS ROSSPAD readout module. A new aluminum housing was built to accommodate a large number of detectors tiled together. Additional changes to startup and processing code were made to operate the detector as one cohesive unit. Spatial resolution of the full panel using Cs-137 gammas was reported to be 0.42 line pairs per centimeter at 90% MTF and 2.09 line pairs per centimeter at 10% MTF. Three neutron radiographs generated using a Cf-252 fission neutron source were used to determine the spatial resolution of the panel for neutrons. The experiments had 90% MTF values of 0.24, 0.3, and 0.27 line pairs per centimeter and 10% MTF values of 1.30, 1.46, and 1.40 line pairs per centimeter. An example neutron radiograph was also used to prove that the radiography panel can perform true neutron radiography.

  • Open Access

    Welcome to the 5th Volume of the Open Journal of Circuits and Systems

    by Nicole McFarlane

    Welcome to the 5th volume of the Open Journal of Circuits and Systems (OJCAS). The Circuits and Systems Society’s Gold Open Access Journal is maturing, welcoming more submissions and getting our first impact factor score. I welcome our new Associate Editor in Chief, Alex James of Digital University Kerala in Trivandrum India to help mature the journal even more. As the journal matures, it is important to note that OJCAS covers all the topics of the society with the only exception being that it is open access. This means we hold submissions to the same quality standard as the other IEEE Journals. As soon as the paper is accepted, the paper is immediately available on IEEE Xplore and freely available to all researchers across the globe. In order to cover the cost of hosting the papers, as well as minimal editing and formatting, the article processing charges are indeed higher than traditional journals. Fortunately, many institutions have open access funds to cover this purpose and some funding agencies in certain countries mandate that research funded by those agencies be freely available to the public. In addition, IEEE has a waiver policy for authors from low and lower-middle income countries. More facts about open access for IEEE can be found at https://open.ieee.org/about/faqs/ .

  • Open Access

    Scalable Detector Design for a High-Resolution Fast-Neutron Radiography Panel

    by Christian X. Young, Chloe A. Browning, Ryan J. Thurber, Matthew R. Smalley, Michael J. Liesenfelt, Jason P. Hayward, Nicole McFarlane, Michael P. Cooper, Jeff R. Preston

    Development of a scalable flat-panel neutron radiography device is needed to meet the nondestructive testing needs of a growing industrial market. Flood field images from a Cs-137 gamma source and a Cf-252 fission neutron source were generated using a detector composed of a 3-mm-thick sheet of EJ-200, and 3-mm-thick sheet of acrylic light spreader, an 8 $$\times $$ × 8 array of SensL MICROFJ-60035-TSV SiPMs, and an IDEAS ROSSPAD readout module. The readout module can be tiled together with similar systems to create a panel of any size, and is only limited by the number of available Ethernet ports in a switching system. A collimated gamma line image demonstrated a 90% spatial resolution of approximately 0.47 line pairs per centimeter and a 10% spatial resolution of approximately 2.32 line pairs per centimeter. A neutron edge image demonstrated a 90% spatial resolution of approximately 0.70 line pairs per centimeter and a 10% spatial resolution of approximately 3.35 line pairs per centimeter. Both of these images show the ability to generate radiographs with sub-SiPM spatial resolution. Using these readout modules, a large-scale radiographic panel can be developed by tiling ROSSPAD modules together.


  • Women in Circuits and Systems (WiCAS) at ISCAS 2022 [Women in CAS]

    by Nicole McFarlane

    A “Women in Circuits and Systems” (WiCAS) event took place during the IEEE International Symposium on Circuits and Systems (ISCAS), held in Austin (TX), USA, from May 28 through June 1, 2022. The event was held on May 30, 2022, organized by Jennifer Blain Christen (Arizona State University, USA), and Nicole McFarlane (University of Tennessee, Knoxville, USA).

  • Open Access

    New Year Editorial 2023

    by Gabriele Manganaro, Nicole Mcfarlane

    DEAR readers, happy 2023! I have recently been elected as the Vice President for Publications for the CAS Society for the 2023–2024 term. Because of that I am unable to complete my term as EiC, which would have otherwise elapsed on 31 December 2023. We are lucky to have two outstanding leaders, Alison Burdett and Nicole Mcfarlane, presently serving as Associate Editors-in-Chief (AEiC). The IEEE Circuits and Systems Society (CASS) has formally appointed Nicole Mcfarlane to serve as the IEEE Open Journal of Circuits and Systems (OJCAS) Editor-in-Chief for the 2023 calendar year and I am glad that she accepted to work in this capacity. I have no doubts that Nicole will carry her new appointment flawlessly and I wish her all the best.

  • Open Access

    A Comprehensive Survey of Readout Strategies for SiPMs Used in Nuclear Imaging Systems

    by Shahram Hatefi Hesari, Mohammad Aminul Haque, Nicole McFarlane

    Silicon photomultipliers (SiPMs) offer advantages such as lower relative cost, smaller size, and lower operating voltages compared to photomultiplier tubes. A SiPM’s readout circuit topology can significantly affect the characteristics of an imaging array. In nuclear imaging and detection, energy, timing, and position are the primary characteristics of interest. Nuclear imaging has applications in the medical, astronomy, and high energy physics fields, making SiPMs an active research area. This work is focused on the circuit topologies required for nuclear imaging. We surveyed the readout strategies including the front end preamplification topology choices of transimpedance amplifier, charge amplifier, and voltage amplifier. In addition, a review of circuit topologies suitable for energy, timing, and position information extraction was performed along with a summary of performance limitations and current challenges.


  • A Combined pH-Impedance System Suitable for Portable Continuous Sensing

    by Shaghayegh Aslanzadeh, Ava Hedayatipour, Matthew Smalley, Nicole McFarlane

    In this paper, a combined pH and impedance sensing system suitable for portable measurements is presented. The sensor outputs are converted directly to frequency or pulse width. The pH sensor is based on a voltage clamp topology that uses charging and discharging capacitors, voltage window comparators, and an SR-Latch to convert the output to frequency. The impedance to frequency sensor is based on current and voltage comparators and an SR-Latch. The pH system based on ISFET transistors is experimentally verified with on chip electrodes while the impedance sensor is characterized with discrete electronic components. The portable system is implemented with two chips and an external multi-electrode array into a portable system. Resistance, capacitance, and pH are experimentally measured using buffer solutions to simulate a water quality monitoring application. The system is implemented in a portable format and all modules, excluding the commercial microprocessor, consume an average power of 56 $ \mu W$ with an area of 0.006 mm $^{2}$ using a 180 nm technology.


  • An Encryption Architecture Suitable for on Chip Integration With Sensors

    by Ava Hedayatipour, Nicole McFarlane

    This paper demonstrates a hardware encryption algorithm that can be integrated directly with sensors on the same chip. In contrast to using power-hungry microprocessors and software implementations, the encryption algorithm was based on a Lorenz chaotic system and was implemented as time scaling chaotic shift keying (TS-CSK). The coupled differential equations of TS-CSK were implemented using low power integrators, multiplexers, switches, and passive components. Both a single-ended and differential system was developed. The single-ended based system showed no oscillation, while the differential based system demonstrated oscillation. Experimental measurements of the differential system with an integrated temperature sensor demonstrated the ability to encrypt and decrypt the transmitted signal. The differential encryption/decryption system was implemented in 180 nm technology and operated with a 1.8 V power supply and 1.5 mW of power.


  • Modeling and Simulation of PGSPAD-Based Silicon Photomultipliers

    by Mst Shamim Ara Shawkat, Sakib Hasan, Nicole Mcfarlane

    This article presents and develops a novel comprehensive simulation model for perimeter gated single-photon avalanche diode-based silicon photomultipliers (PGSPAD SiPMs). A PGSPAD is a modification of single-photon avalanche diodes (SPADs) that contains a third terminal to mitigate perimeter edge breakdown. It does this without excessively enlarging the device area. The applied gate voltage modulates the dynamic range, breakdown voltage, and dark current characteristics. The proposed PGSPAD SiPM model correctly mimics the current-voltage transfer function and the avalanche-quench process of the SiPM detector and is verified by the experimental measurements of a PGSPAD SiPM fabricated in a commercial 0.5- μm CMOS process. The model includes the dark current of the PGSPAD device. This was not included in previous SiPM models. The effect of the number of triggered microcells versus the total number of microcells and the impact of different parameters on the PGSPAD SiPM performance with added gate terminal are evaluated. The photon-electron spectrum with the effect of an extra gate terminal has been studied. Simulation results show very good agreement with experimental measurements.