TLTat-Thang Le

Tat-Thang Le

*This is an algorithmically generated author record based on publicly available information.

Tat-Thang Le has a total of 59 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Optimizing Magnetic Design of LLC Converters for Onboard Chargers: Performance in Wide Voltage and Temperature Ranges

    by Tat-Thang Le, Kiran Pamenan, Thanh-Tung Nguyen, Quang Bach Nguyen

    This article introduces an optimal design methodology for the resonant inductor and transformer in an inductor–inductor–capacitor resonant converter (LLC) converter tailored for on-board charger (OBC) applications. It includes extensive thermal validation tests conducted across a wide input/output voltage range and under extreme temperature conditions, specifically with a coolant temperature of 70 ° C in 80 ° C ambient temperature. The design process focuses on optimizing critical parameters, such as the number of turns, core material, vacuum processing, potting material, and switching frequency. A comparative analysis of different core and winding structures is conducted, evaluating them based on their losses and tolerance levels. The design approach will be validated through experimental results obtained from an 11-kW LLC converter tested across a wide voltage and temperature range. This design methodology proves to be both practical and beneficial for a variety of applications, including general OBCs and low-voltage direct current (LDC) systems.


  • A New Control Method for an On-Board Charger for Electric Vehicles Operating in a Split-Phase System

    by Tat-Thang Le, Gebregergis Abraham, Hoai-Nhan Nguyen, Hoai-Trung Tran, Thanh-Tung Nguyen, Quang Bach Nguyen

    This article introduces a novel control method for an on-board charger (OBC) operating within a split-phase system, which is commonly used in the North American Free Trade Agreement (NAFTA) region, including the United States, Canada, and Mexico. Previous research has not extensively explored control methods for split-phase systems. In response, this article proposes a discontinuous pulsewidth modulation-minimum (DPWM-MIN) approach, which significantly improves efficiency compared to the conventional sinusoidal pulsewidth modulation (SPWM) method. The proposed DPWM-MIN method demonstrates the ability to manage grid conditions when unbalanced loads are present. A comprehensive comparison between SPWM and DPWM-MIN is conducted, focusing on current ripple, switching loss, and core loss analysis. Experimental results from a 7.68-kW OBC prototype are presented to validate the effectiveness of the proposed method. The new control method achieves a peak efficiency of 98%, which is 1% higher than the conventional method. Other performance metrics, such as total harmonic distortion (THD) and the ability to handle unbalanced currents, remain similar to those of the conventional approach.


  • Novel Shielding Method for Planar Transformers to Suppress Common-Mode EMI Noise and Improve Soft-Switching Range

    by Khuong-Duy Le, Quang-Huy Nguyen, Minh-Quan Nguyen, Tat-Thang Le, Trong-Nha Quang, Duy-Dinh Nguyen

    High-frequency LLC resonant converters are crucial for high power density applications such as data center power supplies and battery chargers due to their soft-switching capability. At these frequencies, planar PCB winding transformers are preferred over wire-wound types because of their size and performance advantages. However, high parasitic capacitances, such as inter- and intra-winding capacitance, can increase common-mode (CM) EMI noise and reduce the zero-voltage switching (ZVS) range. To maintain ZVS, either the dead time must be increased or the magnetizing inductance reduced, both of which raise conduction losses. Shielding can mitigate CM noise, but it also adds to transformer’s parasitic capacitance. This article presents a novel floating shielding technique (FST) that blocks CM noise while improving the ZVS range. Testing on a 242 kHz, 380V/48V, 250W LLC half-bridge converter shows that the FST reduces CM noise by 22 dBµV, preserves ZVS, and increases efficiency by 0.46% compared to conventional shielding.


  • A Comprehensive Analysis of Capacitance Network Models of Planar Transformer Across Converter Operating Scenarios

    by Quang-Huy Nguyen, Minh-Quang Ngo, Nhat-Truong Phan, Tat-Thang Le, Duy-Dinh Nguyen

    This study investigates the accuracy and reliability of various capacitance network models for planar transformers typically employed in isolated converters. Parasitic capacitances significantly impact converter performance, affecting zero-voltage switching, efficiency, and electromagnetic interference (EMI). To analyze and evaluate the impact of parasitic capacitances across the converter operating scenarios, a capacitance network model can be used. However, previous studies have not comprehensively assessed the accuracy of these capacitance network models across converter operating scenarios, nor fully explored how transformer structure affects model accuracy. To address these gaps, this study performed simulations and experimental validations to evaluate various capacitance network models across different transformer structures and operating scenarios. The impedance of the planar transformer was used as a benchmark for assessing the accuracy of these models in various scenarios. Four distinct capacitance network models were analyzed across four transformer configurations and six operating scenarios. Results indicated that two models of four models demonstrated consistent accuracy under all conditions. These models are, therefore, recommended to be utilized to analyze the impacts of parasitic capacitances across converter operating scenarios, regardless of winding structure.


  • A Compact 17.6 kW Single-/22 kW Three-Phase Compatible EV Charger: Analysis of Active Power Decoupling, Wide Voltage Range Operation

    by Jaeyeon Lee, Tat-Thang LE, Heonhee Kim, Sewan Choi

    In this article, a single- and three-phase compatible battery charger with active power decoupling (APD) is proposed. The two-stage system consists of CLLC resonant converter for dc–dc converter and integration of two-level inverter (three-phase) and three-phase interleaved totem-pole inverter (single-phase) for ac–dc converter. Through the simple relay operation, the ac–dc converter switches the operations according to the grid phase. By applying the active power decoupling technique to reduce the used capacitance and substitute to film capacitor, it solves the problems of lifespan and stability caused by using electrolytic capacitors. The ac–dc converter variably control the dc link voltage to maximize the battery voltage range of the DCX region with good efficiency characteristics for the dc–dc converter. In addition, the CLLC resonant converter performs the seamless control combining with frequency control and phase-shift control by using only one PI controller. A 17.6/22 kW(1Ø/3Ø), 2.18 kW/L prototype is implemented to validate the proposed concept and demonstrated 95.77% and 94.98% peak efficiency for three- and single-phase, respectively.


  • Open-Circuit Fault-Tolerant Method for Three-Phase CF-DAB Converter With Auto-Balancing Control

    by Tat-Thang Le, The-Tiep Pham, Minh-Khai Nguyen, Truong-Duy Duong, Duy-Dinh Nguyen, Minh-Chau Dinh, Sewan Choi

    Fault-tolerant methods have been recognized for improving the reliability of multi-phase bidirectional DC-DC converters. Few fault-tolerant methods for current-fed dual active bridge (CF-DAB) converter have been developed because it becomes more challenging due to the asymmetrical structure between primary and secondary sides. In this paper, the behaviors of the CF-DAB converter are comprehensively analyzed when an open-circuit fault occurs in different fault scenarios. Analysis and proposed fault-tolerant method are aimed to determine the open-circuit cases which can recover full conversion power after the fault occurs. Moreover, this paper also proposed an auto-balancing control method to prevent the converter from being out of control. The proposed balancing control method can be utilized for general multi-phase current-fed converters. A 6-kW prototype is built to verify the proposed method.


  • Open Access

    Open-Circuit Fault-Tolerant Method for Three-Phase CF-DAB Converter with Auto-Balancing Control

    by Tat-Thang Le

    Fault-tolerant methods have been recognized for improving the reliability of multi-phase bidirectional DC-DC converters. Few fault-tolerant methods for current-fed dual active bridge (CF-DAB) converters have been developed because it becomes more challenging due to the asymmetrical structure between primary and secondary sides. In this paper, the behaviors of the CF-DAB converter are comprehensively analyzed when an open-circuit fault occurs in different fault scenarios. Analysis and proposed fault-tolerant method are aimed to determine the open-circuit cases which can recover full conversion power after the fault occurs. Moreover, this paper also proposed an auto-balancing control method to prevent the converter from being out of control. The proposed balancing control method can be utilized for general multi-phase current-fed converters. A 6-kW prototype is built to verify the proposed method.

  • Single-Stage Totem-Pole AC–DC Converter Based on Boost Half-Bridge Structure for Battery Chargers

    by Tat-Thang Le, Jaeyeon Lee, Sewan Choi

    In this article, a new single-stage bridgeless totem-pole ac–dc converter is proposed. The proposed converter is composed of two single-stage boost half-bridge ac–dc converters with the interleaved operation. Besides, while preserving the advantages of the L -type half-bridge-based single-stage totem-pole ac–dc converter, the proposed converter has the ability of phase-shedding operation, which helps to increase the total efficiency of the converter due to reduced switching and core losses by half under medium and light loads. A hybrid harmonic injection in phase shift and duty cycle according to battery voltage is proposed, which not only improves total harmonic distortion to smaller than 4% under the whole load range but also extends the zero-voltage switching range of the converter under a wide voltage range. The proposed control method can be utilized in the general dual-active-bridge-based single-stage converter. Experimental results from a 1.5-kW prototype are provided to validate the proposed concepts.


  • Open Access

    Impact of Parameter Mismatch on Three-Phase Dual-Active-Bridge Converters

    by Duy-Dinh Nguyen, The-Tiep Pham, Tat-Thang Le, Ton Duc Do, Takuya Goto, Kazuto Yukita

    Three-phase dual active bridge converters (DAB3) are a widely used topology in battery charging applications thanks to their numerous advantages, such as bidirectional power flow, galvanic isolation, low output current ripple, and inherent soft-switching. In such applications, three single-phase transformers are commonly employed as the AC-link to simplify manufacturing and reduce costs. These transformers’ leakage inductance can be utilized instead of the external leakage inductance to achieve high power density. However, the assumption of uniformity in these inductances is not always accurate as they can vary significantly during fabrication. This study presents a comprehensive analysis of the impact of transformer leakage inductance variation, which can deviate by up to 24% from the desired value. The effects of this variation are investigated from different perspectives, including power transfer, soft-switching range, root-mean-square (RMS) current, and the temperature rise of the transformer winding. Although the power transfer and total copper loss of transformers are changed insignificantly even under highly mismatched leakage inductance, the currents and thermal distribution among phases are considerably impacted. Based on statistical probability, a maximum leakage inductance variation threshold of 10–15% compared to the desired value is recommended to ensure the maximum acceptable temperature rise among phases. Experimental results are presented to validate the analysis.


  • Open Access

    A Modulation Method for Three-Phase Dual-Active-Bridge Converters in Battery Charging Applications

    by Duy-Dinh Nguyen, The-Tiep Pham, Tat-Thang Le, Sewan Choi, Kazuto Yukita

    The Three-phase Dual-Active-Bridge (DAB3) converters are a common choice for quick charging stations for batteries in electric vehicles due to their high power density, versatility, and galvanic isolation capability. However, the DAB3 topology has limited soft-switching range, particularly under light load conditions when the voltage conversion ratio differs significantly from unity, resulting in hard switching, increased loss, and higher electromagnetic interference. To address these issues, various techniques have been proposed, but they often lead to other problems such as higher current ripple or unbalanced thermal distribution. In this paper, a new modulation scheme, called symmetric duty-cycle control (SDM), is proposed for DAB3 converters to overcome these issues. A multiaspect comparison of SDM was conducted against two existing techniques, SPS and ADCC, and its superiority was validated through simulation and experimental results. Our proposed SDM scheme provides a current ripple within 10% to 15% of the average current and enables zero current switching for the whole voltage and power ranges. Additionally, a modified version of SDM can even improve overall efficiency by 7% compared to the conventional SPS technique.