Sanjay Kumar
Sanjay Kumar has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Barjeev Tyagi
Electrical Engineering Department, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand, India
3 shared publications - Sunita Chohan
Load Despatch and Communication Department, Power Grid Corporation of India Limited, Gurugram, Haryana, India
3 shared publications - Vishal Kumar
Electrical Engineering Department, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand, India
3 shared publications - Jagannath Samantaray
Department of Electrical Engineering, Indian Institute of Technology Roorkee, Roorkee, India
1 shared publication - Maneesh Kumar
Department of Hydro & Renewable Energy, Indian Institute of Technology, Roorkee, India
1 shared publication - Sachidananda Sen
SR University
1 shared publication
Latest Publications
- 8 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (3) , 4870-4887
An Adaptive Fuzzy Controller-Based Distributed Voltage Control Strategy for a Remote Microgrid System With Solar Energy and Battery Support
This paper presents a robust decentralized voltage control strategy for a remote microgrid (rMG) system. The proposed decentralized voltage control strategy is applied to a voltage source inverter (VSI) through a pulse width modulation (PWM) technique. To implement the strategy, a small-scale remote microgrid test system is considered, supported by solar photovoltaic (SPV) and battery energy storage system (BSS). The two sources are connected through a common inverter connected to a three-phase system. Maximum power extraction is considered from the SPV system using an MPPT-based algorithm. The output voltage of the common inverter is maintained by triggering the inverter circuit in a controlled way using the PWM technique. BSS charging and discharging are also controlled through a controller circuit. The uncertainty in the solar irradiance data is captured through a series of variations with different slew rates. The output voltage VSI is controlled using an adaptive fuzzy PID controller (AFPID). This controller eliminates the need for the optimal adaptation gain value for robust control. The VSI voltage control is achieved by considering the peak value of the three-phase AC voltage as a reference, and a closed-loop dq control is implemented. The results are analyzed under various system conditions, and a comparative assessment is obtained with other control schemes such as dual-loop PID, model reference adaptive controller (MRAC), and APID controller. It is observed that the AFPID provides better voltage control and stability to the system as compared to other control schemes. The overall performance of the proposed fuzzy controller is investigated with the help of various performance indices.
- 8 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (3) , 4870-4887
An Adaptive Fuzzy Controller-Based Distributed Voltage Control Strategy for a Remote Microgrid System With Solar Energy and Battery Support
This paper presents a robust decentralized voltage control strategy for a remote microgrid (rMG) system. The proposed decentralized voltage control strategy is applied to a voltage source inverter (VSI) through a pulse width modulation (PWM) technique. To implement the strategy, a small-scale remote microgrid test system is considered, supported by solar photovoltaic (SPV) and battery energy storage system (BSS). The two sources are connected through a common inverter connected to a three-phase system. Maximum power extraction is considered from the SPV system using an MPPT-based algorithm. The output voltage of the common inverter is maintained by triggering the inverter circuit in a controlled way using the PWM technique. BSS charging and discharging are also controlled through a controller circuit. The uncertainty in the solar irradiance data is captured through a series of variations with different slew rates. The output voltage VSI is controlled using an adaptive fuzzy PID controller (AFPID). This controller eliminates the need for the optimal adaptation gain value for robust control. The VSI voltage control is achieved by considering the peak value of the three-phase AC voltage as a reference, and a closed-loop dq control is implemented. The results are analyzed under various system conditions, and a comparative assessment is obtained with other control schemes such as dual-loop PID, model reference adaptive controller (MRAC), and APID controller. It is observed that the AFPID provides better voltage control and stability to the system as compared to other control schemes. The overall performance of the proposed fuzzy controller is investigated with the help of various performance indices.
- 19 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-11
PMU-Based Voltage Stability Measurement Under Contingency Using ANN
An artificial neural network (ANN) is an effective and efficient approach for solving problems, which require fast and complicated computation. The study proposed a PMU measurement-based voltage stability monitoring and assessment using ANN hybrid model for the evaluation of voltage stability margin. Particle swarm optimization (PSO) optimizes the meta-parameter of ANNs for improving its convergence rate. This model helps in real-time monitoring of long-term voltage stability to avoid grid blackout. The power system security is generally defined based on the single contingency “N−1” criterion, meaning normal system minus one element. Separate ANNs are trained and designed for selected worst case “N−1” contingencies along with base case configuration. Phasor Measurement Unit installed at distant locations provide real-time synchronized measurements of voltage phasor, which forms the input feature for the proposed model. Load $P$ margin evaluated by continuation power flow (CPF) method is considered as output feature of the proposed ANN model. The performance indices mean absolute percentage error (MAPE) and maximum percentage error (MPE) with smaller values indicate small deviation between the estimated and the actual values. The proposed approach is effectively tested on IEEE 14-bus and 30-bus test system.
- 19 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-11
PMU-Based Voltage Stability Measurement Under Contingency Using ANN
An artificial neural network (ANN) is an effective and efficient approach for solving problems, which require fast and complicated computation. The study proposed a PMU measurement-based voltage stability monitoring and assessment using ANN hybrid model for the evaluation of voltage stability margin. Particle swarm optimization (PSO) optimizes the meta-parameter of ANNs for improving its convergence rate. This model helps in real-time monitoring of long-term voltage stability to avoid grid blackout. The power system security is generally defined based on the single contingency “N−1” criterion, meaning normal system minus one element. Separate ANNs are trained and designed for selected worst case “N−1” contingencies along with base case configuration. Phasor Measurement Unit installed at distant locations provide real-time synchronized measurements of voltage phasor, which forms the input feature for the proposed model. Load $P$ margin evaluated by continuation power flow (CPF) method is considered as output feature of the proposed ANN model. The performance indices mean absolute percentage error (MAPE) and maximum percentage error (MPE) with smaller values indicate small deviation between the estimated and the actual values. The proposed approach is effectively tested on IEEE 14-bus and 30-bus test system.
- 26 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (12) , 9893-9906
Optimization of Phasor Measurement Units Placement Under Contingency Using Reliability of Network Components
This study reports an optimization technique to reduce the requirement of phasor measurement units (PMUs) for complete observability under contingency with the use of component reliability. The present methodology secures the data measurement of unreliable and weak-load buses of power network considering hybrid observability for multiphase PMUs installation. The ( $N - 1$ ), ( $N - 2$ ) contingency present in the power network requires redundancy for data measurement. The network components with high reliability decrease the contingency of power networks. This reduces the requirement of data measurement redundancy for the network component having high reliability. This article utilizes this relationship between network component reliability and power network contingency to propose the concept of hybrid observability for PMU placement. It combines the concept of complete and redundant observabilities. Power network reliability is determined by incorporating the component reliability of the PMU data measurement system. Weak-load buses responsible for voltage collapse are determined by varying reactive power loading. Furthermore, the proposed weak-load bus closeness criteria (WLCC) and reliability observability criterion (ROC) are utilized for performing ranking of PMU locations using an analytical hierarchical process. These criteria identify the most significant location for initial phases of PMU installation. This strengthens the data measurement of weak-load buses through the most reliable network preventing voltage collapse due to data unavailability even during initial phases of PMU placement. The proposed methodology is illustrated on the IEEE 30-bus and NRPG 246-bus system.
- 26 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (12) , 9893-9906
Optimization of Phasor Measurement Units Placement Under Contingency Using Reliability of Network Components
This study reports an optimization technique to reduce the requirement of phasor measurement units (PMUs) for complete observability under contingency with the use of component reliability. The present methodology secures the data measurement of unreliable and weak-load buses of power network considering hybrid observability for multiphase PMUs installation. The ( $N - 1$ ), ( $N - 2$ ) contingency present in the power network requires redundancy for data measurement. The network components with high reliability decrease the contingency of power networks. This reduces the requirement of data measurement redundancy for the network component having high reliability. This article utilizes this relationship between network component reliability and power network contingency to propose the concept of hybrid observability for PMU placement. It combines the concept of complete and redundant observabilities. Power network reliability is determined by incorporating the component reliability of the PMU data measurement system. Weak-load buses responsible for voltage collapse are determined by varying reactive power loading. Furthermore, the proposed weak-load bus closeness criteria (WLCC) and reliability observability criterion (ROC) are utilized for performing ranking of PMU locations using an analytical hierarchical process. These criteria identify the most significant location for initial phases of PMU installation. This strengthens the data measurement of weak-load buses through the most reliable network preventing voltage collapse due to data unavailability even during initial phases of PMU placement. The proposed methodology is illustrated on the IEEE 30-bus and NRPG 246-bus system.
- Open Access
- 30 July 2018
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 12 (16) , 3900-3909
Incremental PMU placement considering reliability of power system network using analytical hierarchical process
This study presents a methodology for enhancing the observability of interconnected power network with the incorporation of component reliability for incremental phasor measurement units (PMUs) placement. Initially, multiple optimal solutions for complete observability have been determined with the use of genetic algorithm. An overall system reliability index has been proposed for the selection of the most suitable solution among the determined solutions. Furthermore, the ranking of the buses for PMU placement has been performed using the proposed reliability observability criteria. An index determined by series–parallel combinations of different components of the network has been used for this purpose. To achieve effective multi‐phasing of PMU placement analytical hierarchical process has been utilised. This strengthens the observability through most reliable buses during the initial phases. The proposed methodology is illustrated on IEEE 14‐bus and eastern region Indian power grid 90‐bus real system.
- 30 July 2018
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 12 (16) , 3900-3909
Open AccessIncremental PMU placement considering reliability of power system network using analytical hierarchical process
This study presents a methodology for enhancing the observability of interconnected power network with the incorporation of component reliability for incremental phasor measurement units (PMUs) placement. Initially, multiple optimal solutions for complete observability have been determined with the use of genetic algorithm. An overall system reliability index has been proposed for the selection of the most suitable solution among the determined solutions. Furthermore, the ranking of the buses for PMU placement has been performed using the proposed reliability observability criteria. An index determined by series–parallel combinations of different components of the network has been used for this purpose. To achieve effective multi‐phasing of PMU placement analytical hierarchical process has been utilised. This strengthens the observability through most reliable buses during the initial phases. The proposed methodology is illustrated on IEEE 14‐bus and eastern region Indian power grid 90‐bus real system.