BFBruno Fain

Bruno Fain

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bruno Fain has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Flexible hybrid electronics including a micromachined ultrasonic transducer for wearable physiological monitoring

    by Jean-Charles Souriau, Hélène Lhermet, François Blard, Laurent Gerfault, Jean-Rémi Chatroux, Rémi Franiatte, Daniel Mermin, Aurélia Plihon, Pierre Blandin, Bruno Fain

    Flexible hybrid electronics (FHE) is a breakthrough in semiconductor packaging and an opportunity in the field on medical applications, such as the monitoring of physiological parameters using wearable devices. Using ultrasound on portable systems is a promising way to probe vascular network and arteries. This article focuses on developing a flexible, thin label that incorporates a piezoelectric micromachined ultrasonic transducer (PMUT) and can be used in a medical patch. The process described is carried out on a silicon wafer carrier in a microelectronic manufacturing line, enabling high integration resolution. PMUTs are hybridized on a flexible interconnection redistribution layer using flip-chip technology; they are thinned down and encapsulated with polyimide film. Finally, the label is attached to a ribbon and fully encapsulated with Parylene that provides biocompatibility and moisture tolerance. The functionality of the flexible PMUT arrays is validated through acoustic measurements in water.

  • Characterization of a Multi-Channel CMUT Gas Sensor

    by Charles Boutonnet, Anurupa Shaw, Jean-Claude Bastien, François Blard, Adrien Vialletelle, Vincent Pinon, Christophe Le Blanc, Cyril Herrier, Thierry Livache, Bruno Fain

    We report the design, the fabrication and the test of a multi-channel gas sensor based on Capacitive Micro-machined Ultrasonic Transducers (CMUT) functionalized with peptides as sensing material, dedicated to volatile organic compound (VOC) measurements in ambient air. The design, the fabrication and the electrical test of the CMUT device is reported, achieving a mass sensitivity per unit area of $\mathbf{5.9~Hz/(ag/\boldsymbol{\mu}m^{2})}$ . The corresponding electronics, ensuring self-sustained oscillations of the loops, is described. Experimental characterization of the loops using a Vector Network Analyser (VNA) and associated simulations using Eldo software highlight how the Barkhausen criteria are fulfilled. A gas flow setup is used to expose the sensors to different gases. The three channels of the device reveal different sensitivities to gas, ranging from $\mathbf{0.13~Hz/ppmv}$ to $\mathbf{0.41~Hz/ppmv}$ for nonane. This is attributed to different surface affinities towards nonane, confirming the potential of CMUT devices for electronic noses. 2024-0089


  • Modeling and characterization of AlN-Based piezoelectric micromachined ultrasonic transducers

    by Romain Liechti, François Blard, Jean-Rémi Chatroux, Jean-Claude Bastien, Aude Lefèvre, Hélène Lhermet, Bruno Fain

    In this paper, we present the modeling and characterization of AlN-based piezoelectric micromachined ultrasonic transducers (PMUTs) dedicated to biomedical applications. Our study encompasses detailed analytical modeling of these transducers in both air and water environments. The model is confronted with finite element simulations that account for realistic issues such as imperfect clamping. To validate the model’s relevance, we compare its predictions with results from optical, electrical, and acoustical characterization. This comprehensive approach provides a robust framework for understanding PMUT behavior and facilitates efficient modeling of future devices.


  • Open Access

    Efficient Modeling of Piezoelectric Micromachined Ultrasonic Transducers Using a Combination of Finite and Lumped Element Modeling

    by Romain Liechti, Francois Blard, Jean-Rémi Chatroux, Jean-Claude Bastien, Hélène Lhermet, Bruno Fain

    This research paper presents a comprehensive methodology for the efficient modeling of piezoelectric micromachined ultrasonic transducers (PMUTs) using a combination of finite and lumped element models. A single membrane is first studied in air with an eigenfrequency study in order to calibrate the lumped element model on the finite element model. From this electrical equivalent circuit, a complete model of the PMUT cell composed of numerous membranes is developed using the propagation, directivity, absorption, mutual and self-impedances, and variability of the resonance frequencies due to manufacturing discrepancies. The calculated acoustic response of the PMUT is then compared with a measured response, in water. The relatively good agreement between the simulation and the measurement, as well as the very low computation time, makes this approach relevant for further optimization of the PMUT design to target larger bandwidth and higher sensitivity.


  • Wafer-level experimental study of residual stress in AlN-based bimorph piezoelectric micromachined ultrasonic transducer

    by Joontaek Jung, Jean-Claude Bastien, Aude Lefevre, Kevin Benedetto, Rémy Dejaeger, François Blard, Bruno Fain

    During the last decade, piezoelectric micromachined ultrasonic transducer (pMUT) have raised a great interest for various applications. In particular, AlN material has been used to build bimorph structures made of two AlN layers sandwiched between metallic electrodes. This kind of pMUT offer good performances for both sensing and actuating because of the multi-electrodes scheme of the design. Yet, this pMUT architecture is expected to be particularly sensitive to residual stress within the AlN layers. At the wafer level, stress dispersion is likely to cause important performance variations. In this paper, we characterize bimorph pMUT working in the 50–250 kHz range to investigate how much stress variations at the wafer level (8″) impact critical pMUT features such as resonant frequency, sensitivity and quality factor. Drive sensitivity up to 216 nm/V are obtained with a single electrode scheme. Two approaches are combined, respectively based on pMUT simulation and curvature measurement, to assess the contribution of AlN residual stress to the overall tension of the diaphragm, ranging from −300 to 900 N m −1 . The resulting dispersion of resonant frequency is higher than 100%. We highlight how to obtain satisfactory yield.