YTYuguo Tang

Yuguo Tang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yuguo Tang has a total of 209 co-authors. Here are the top co-authors by number of shared publications:

  • Peng Miao

    University of Science and Technology of China

    10 shared publications
  • Bidou Wang

    CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China

    5 shared publications
  • Hongbo Jia

    Advanced Institute for Brain and Intelligence, School of Physical Science and Technology, Guangxi University

    4 shared publications
  • Gang Wen

    Academy for Engineering and Technology, Fudan University, Shanghai, China

    3 shared publications
  • Hui Li

    Laboratory of Advanced Theranostic Materials and Technology Ningbo Institute of Materials Technology and Engineering Chinese Academy of Sciences Ningbo China

    3 shared publications
  • Jing Lyu

    Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China

    3 shared publications

Latest Publications

  • Open Access

    Ultra-wide-field, deep, adaptive two-photon microscopy for multi-scale neuronal imaging

    by Mengke Yang, Zhen-Qiao Zhou, Song Lang, Hanqing Zheng, Shuai Chen, Tong Li, Eline Stas, Jess Yu, Long Zhang, Zhi Zhang, et al.

    Observing the activity patterns of large neural populations throughout the brain is essential for understanding brain function. However, capturing neural interactions across widely distributed brain regions from both superficial and deep cortical layers remains challenging with existing microscopy technologies. Here, we introduce a state-of-the-art two-photon microscopy system, ULTRA, capable of single-cell resolution imaging across an ultra-large field of view (FOV) exceeding 50 mm², enabling deep and wide field in vivo imaging. To demonstrate its capabilities, we conducted a series of experiments under multiple imaging conditions, successfully visualizing brain structures and neuronal activities spanning a spatial range of over 7 mm from superficial layers to depths of up to 900 μm, while covering a volume of 45.24 mm 3 in the mouse brain. This versatile imaging platform overcomes traditional spatial constraints, providing a powerful tool for comprehensive exploration of neuronal circuitry over extensive spatial scales with cellular resolution.


  • Open Access

    An Enhanced Electrochemiluminescence Immunoassay Platform via Optimized Magnetic Bead Uniformity for Reliable Thyroid-Stimulating Hormone Monitoring

    by Hengbo Lei, Xinyu Huang, Xiang Cao, Yuguo Tang, Yang Ge

    Electrochemiluminescence immunoassay (ECLIA) is widely used in clinical diagnostics owing to its high sensitivity, broad dynamic range, and excellent analytical stability. However, the influence of magnetic bead deposition behavior on electrochemiluminescence (ECL) signal performance remains insufficiently characterized. In this study, a quantitative evaluation method for magnetic bead distribution uniformity on the electrode surface was established and applied to optimize fluidic parameters in an ECLIA measurement system. By combining microscopic imaging with image analysis, magnetic bead spreading behavior under different flow conditions was systematically characterized and correlated with luminescence signal intensity. Optimization of the flow rate (18.46 µL·s−1) improved bead distribution uniformity and resulted in a 26.32% increase in luminescence intensity without altering bead coverage or assay chemistry. The optimized system was further validated using thyroid-stimulating hormone (TSH) detection, showing a linear response over 0.016–120 µIU·mL−1 (R2 > 0.996) and high consistency with a commercial analyzer (R2 = 0.998) from Roche. These results demonstrate that quantitative control of magnetic bead distribution provides an effective strategy for improving ECLIA performance and offers a general optimization framework for bead-based electrochemiluminescence systems.


  • Open Access

    Cellular multipoint adaptive technology for two-photon mesoscope

    by Shuai Chen, Mengke Yang, Jing Lyu, Yu Huang, Hong Ye, Qian Gao, Tangmin Chen, Haiyang Chen, Huanhuan Zeng, Min Li, et al.

    SignificanceIn mesoscopic imaging research in neuroscience, achieving high spatial resolution optical imaging across the entire field of view (FOV) remains critical. This directly determines whether researchers can precisely analyze the large-scale dynamic activities of neural circuits at the single-cell or even subcellular level. Consistent optical quality throughout the entire imaging FOV is essential to accurately capture the spatiotemporal patterns of neural activity across brain regions, thereby providing a powerful tool for understanding the circuit mechanisms underlying cognition, behavior, and disease at cellular and subcellular resolution in vivo.AimThis study aims to develop a technology that extends the imaging FOV in a two-photon mesoscope while enhancing the optical quality across the entire FOV in vivo. The key point is to establish a robust method that can significantly extend the FOV beyond what the micro/mesoscope objective had been originally designed for, yet maintain the original resolution specifications. As such, the value of the method also extends beyond improving just one mesoscope, which we use as a demo in this study.ApproachThis study introduces an innovative approach that combines block scanning with adaptive optical (AO) correction through a bioinspired honeycomb-based cellular multipoint adaptive technology (CMAT) to achieve mesoscopic two-photon imaging. This system enables unprecedented large-FOV, high-resolution imaging by dividing an 8×8 mm2 imaging area into subregions, each pre-optimized with deformable mirror (DM) compensation while applying real-time dynamic wavefront correction during scanning. Furthermore, we have designed multiple user-defined sub-region scanning functions. Each sub-region automatically loads the aberration correction compensation values from the nearest reference point relative to its center, thereby ensuring optimal optical performance for every individual sub-region. The robustness of this technology has been systematically verified across multiple neural circuit observation scenarios using transgenic mouse models, demonstrating its capability for reliable single-cell resolution imaging across extensive brain regions.ResultsComprehensive evaluation using standard samples and transgenic mouse models demonstrated that the CMAT significantly enhances the imaging performance of the two-photon mesoscope. This technique extends the effective two-photon imaging FOV from 6×6 mm2 to 8×8 mm2 while markedly improving the optical quality in the peripheral regions. High resolution was maintained at ∼1 μm (lateral) and ∼10 μm (axial) in the central area, with edge regions achieving improved resolutions of ∼1.3 μm (lateral) and ∼14 μm (axial). Quantitative analysis confirmed that multipoint AO not only enhances image contrast and optical resolution but also substantially increases the signal-to-noise ratio (SNR) in Ca2+ imaging. This work delivers a pivotal technical advance for large-scale functional imaging of neural circuits.ConclusionCMAT significantly extends the effective FOV and enhances the optical quality of the two-photon mesoscope system.

  • Open Access

    A novel preparation method for monodisperse streptavidin magnetic beads and its application in electrochemiluminescent immunoassay for CEA

    by Hengbo Lei, Yuguo Tang

    The magnetic microspheres coated with streptavidin (PS-SA) were successfully prepared by loading streptavidin onto modified hyperbranched poly(glycerol) (HPG) magnetic microspheres. This material was comprehensively characterized using various methods, including scanning electron microscopy, thermogravimetric analysis, fourier-transform infrared spectroscopy, vibrating sample magnetometry and zeta potential measurement. This study introduced a novel electrochemiluminescence immunoassay utilizing functionalized magnetic microspheres for the ultrasensitive detection of carcinoembryonic antigen (CEA). The sensor employed Ru(bpy) 3 2+ -labeled anti-CEA-Ab2 (Ru-Ab2) as the signal probe and combined it with monodisperse streptavidin magnetic beads and biotinylated anti-CEA-Ab1 (bio-Ab1) to selectively capture CEA. Under optimized conditions, the immunosensor exhibited a broad linear range from 0.05 to 1000 ng/mL for CEA detection (R² = 0.998), along with an exceptionally low detection limit (LOD) of 0.02383 ng/mL. Moreover, the developed immunosensor demonstrated remarkable selectivity, excellent stability, and satisfactory reproducibility, indicating its significant potential for clinical diagnostic applications.


  • Open Access

    Automatic Tuning Method for Quadrupole Mass Spectrometer Based on Improved Differential Evolution Algorithm

    by Yuanqing Zhang, Baolin Xiong, Le Feng, Liang Li, Wenbo Cheng, Yuguo Tang

    Quadrupole mass spectrometers are highly sensitive and specific analytical instruments, widely used in pharmaceuticals, clinical diagnostics, and other fields. Their performance depends on a tuning process to optimize key parameters, which has traditionally relied on engineers’ expertise or simple univariate search methods. This paper proposes an automatic tuning method using an improved differential evolution algorithm. This algorithm introduces a ranking and subpopulation classification for individuals, enabling distinct mutation strategies. Validation on the CEC-2017 benchmark functions confirms the superiority of the improved algorithm. In automatic tuning experiments, it achieved a 25.3% performance gain over the univariate search method and also surpassed both the classical differential evolution algorithm and standard particle swarm optimization algorithm. This method proves to be an effective approach for enhancing the performance of quadrupole mass spectrometers.

  • TrCL-AGS: A Universal Sequential Triple-Stage Contrastive Learning Framework for Bacterial Detection With Across-Growth-Stage Information

    by Lesong Zheng, Yunbo Guo, Ying Liang, Lirong Wang, Siyu Meng, Yizhi Song, Yuguo Tang

    The imprudent use of antibiotics has led to increased bacterial resistance, posing a serious threat to public health. Traditional visual-based antibiotic susceptibility testing (AST) methods are time-consuming and labor-intensive. Deep-learning-based bacterial detection algorithms have significantly improved the efficiency and accuracy of AST. However, existing deep-learning-based bacterial detection algorithms ignore unique challenges of AST images, such as confluent clusters, complex backgrounds, and morphologically similar noise. To address these issues, we propose a novel bacterial detection framework named the triple-stage contrastive learning framework with across-growth-stage information (TrCL-AGS). Specifically, we design a novel across-growth-stage pretraining (AGSP) task to mine across-growth-stage information from the continuous images, providing a richer and more robust feature space for subsequent stages. Instance-level contrastive learning (ILCL) is constructed to extract invariant semantic features of bacteria at a particular growth stage and exclude features similar to bacteria but do not match the specific growth stages. Besides, discriminative features between objects and backgrounds are enhanced by the category-level contrastive learning (CLCL) stage. Extensive experiments on a real-world clinical bacterial AST dataset demonstrate that our method can achieve state-of-the-art performance compared with existing object detection methods. And our framework is compatible with most detectors.


  • Open Access

    Rapid Autofocus Method Based on LED Oblique Illumination for Metaphase Chromosome Microscopy Imaging System

    by Changliang Yu, Fangqiu Ding, Zhenyu Ma, Yuguo Tang

    In clinical practice, microscopes are commonly used for imaging chromosomes to diagnose genetic diseases. Achieving precise and rapid autofocusing is a significant challenge in the advancement of high-throughput chromosome imaging systems. Here, we introduce a rapid autofocus method based on LED oblique illumination for dual-objective configuration in metaphase chromosome imaging system. Our method utilizes a programmable LED array for sample illumination, employing a sequential activation of two LEDs from opposing angles to create oblique illumination. The defocus distance is ascertained through image cross-correlation calculation. Illumination with multiple LEDs in the array is used to acquire bright-field images after completing the focusing. Our method can perform continuous autofocus under a 10× objective and a 100× oil immersion objective, with average focusing errors of 1.29 μm and 0.12 μm, respectively. The total imaging time for a single sample has been significantly reduced from approximately 10 min with conventional methods to just 2 min. This study provides preliminary evidence supporting the viability of developing a next-generation high-throughput chromosome scanner employing a LED array.


  • Open Access

    Spectrum-optimized direct image reconstruction of super-resolution structured illumination microscopy

    by Gang Wen, Simin Li, Yong Liang, Linbo Wang, Jie Zhang, Xiaohu Chen, Xin Jin, Chong Chen, Yuguo Tang, Hui Li

    Super-resolution structured illumination microscopy (SR-SIM) has become a widely used nanoscopy technique for rapid, long-term, and multi-color imaging of live cells. Precise but troublesome determination of the illumination pattern parameters is a prerequisite for Wiener-deconvolution-based SR-SIM image reconstruction. Here, we present a direct reconstruction SIM algorithm (direct-SIM) with an initial spatial-domain reconstruction followed by frequency-domain spectrum optimization. Without any prior knowledge of illumination patterns and bypassing the artifact-sensitive Wiener deconvolution procedures, resolution-doubled SR images could be reconstructed by direct-SIM free of common artifacts, even for the raw images with large pattern variance in the field of view (FOV). Direct-SIM can be applied to previously difficult scenarios such as very sparse samples, periodic samples, very small FOV imaging, and stitched large FOV imaging.


  • Theoretical foundation for designing multilayer Halbach array magnets for benchtop NMR and MRI

    by Peng Yu, Ya Wang, Yajie Xu, Zhongyi Wu, Ying Zhao, Bowen Peng, Feng Wang, Yuguo Tang, Xiaodong Yang