Zengpeng Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zengpeng Wang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Dong Huang
Department of Refrigeration & Cryogenic Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China
1 shared publication - Fei Wang
School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China
1 shared publication - Rijing Zhao
Department of Refrigeration & Cryogenic Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China
1 shared publication - Yu Sun
Department of Refrigeration & Cryogenic Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China
1 shared publication
Latest Publications
- Open Access
- 6 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (18) , 8960
Effect of the Number of Circuits on a Finned-Tube Heat Exchanger Performance and Its Improvement by a Reversely Variable Circuitry
The finned-tube heat exchanger (FTHX) works better with more circuits as an evaporator but fewer as a condenser in air-source heat pumps (ASHPs). In this article, a reversely variable circuitry is proposed to address this contradiction. The effects of the circuit number on the performance of an outdoor FTHX in an ASHP prototype was first studied numerically using the EVAP-COND 4.0 software. We showed that the evaporator capacity reached its peak with four circuits, but the condenser capacity decreased monotonously as the circuit number increased. A reversely variable circuitry was obtained by combining distributors and check valves, so that the FTHX exhibited four circuits in the evaporator mode but one and a half (two circuits merging into one) in the condenser mode, thus better matching the respective requirements of the two modes. Comparative tests showed that in the ASHP, the reversely variable FTHX had a 6.1% higher cooling capacity than the four-circuit reversely fixed exchanger and a 3.9% higher heating capacity than the 1.5-circuit reversely fixed one. Therefore, the novel design of the FTHX enhanced both the heating and the cooling performance of the ASHP.
- 6 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (18) , 8960
Open AccessEffect of the Number of Circuits on a Finned-Tube Heat Exchanger Performance and Its Improvement by a Reversely Variable Circuitry
The finned-tube heat exchanger (FTHX) works better with more circuits as an evaporator but fewer as a condenser in air-source heat pumps (ASHPs). In this article, a reversely variable circuitry is proposed to address this contradiction. The effects of the circuit number on the performance of an outdoor FTHX in an ASHP prototype was first studied numerically using the EVAP-COND 4.0 software. We showed that the evaporator capacity reached its peak with four circuits, but the condenser capacity decreased monotonously as the circuit number increased. A reversely variable circuitry was obtained by combining distributors and check valves, so that the FTHX exhibited four circuits in the evaporator mode but one and a half (two circuits merging into one) in the condenser mode, thus better matching the respective requirements of the two modes. Comparative tests showed that in the ASHP, the reversely variable FTHX had a 6.1% higher cooling capacity than the four-circuit reversely fixed exchanger and a 3.9% higher heating capacity than the 1.5-circuit reversely fixed one. Therefore, the novel design of the FTHX enhanced both the heating and the cooling performance of the ASHP.