Siru Kaartinen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Siru Kaartinen has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Ari-Petteri Ronkainen
Clinical Imaging Center Kuopio University Hospital Kuopio Finland
2 shared publications - Mimmi K. Liukkonen
Kuopio University Hospital
2 shared publications Ari-Petteri Ronkainen
Department of Clinical Radiology, Wellbeing Services County of North Savo, Kuopio University Hospital, Puijonlaaksontie 2, 70210 Kuopio, Finland
1 shared publication- Hanna Matikka
Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland
1 shared publication Mimmi K. Liukkonen
Department of Clinical Radiology, Wellbeing Services County of North Savo, Kuopio University Hospital, Puijonlaaksontie 2, 70210 Kuopio, Finland
1 shared publication- Minna Husso
Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland
1 shared publication
Latest Publications
- Open Access
- 22 July 2026
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 46 (3) , 031519
Effect of radiation protection apron defect on radiation dose during fluoroscopy
Occupational exposure should be minimised to a level that is as low as reasonably achievable. Radiation protection aprons and thyroid collars are effective in reducing occupational radiation dose as they typically attenuate at least 90% of scattered radiation. However, cracks and holes may compromise the shielding capacity of the apron. The aim of the study was to quantify change in radiation dose behind defects to support the development of rejection criteria for damaged aprons. Air kerma rates were measured with a calibrated solid‐state dosimeter behind a 0.25 mm Pb‐equivalent apron containing seven circular defects (diameter 1.5–20 mm) and one horizontal crack (50 mm) under two clinical fluoroscopy settings and compared with measurements obtained behind an intact apron. The air kerma rate increased by up to 165 µ Gy h −1 behind the damaged apron. Based on average annual fluoroscopy times per operator at Kuopio University Hospital, the use of damaged apron could result in an annual air kerma increase of 9.7 mGy behind the damaged area. Defect size and location affect the shielding performance of protective aprons. Considering defect position in rejection criteria allows more realistic estimation of the potential impact on staff effective dose and helps avoid unnecessary replacement of protective garments. Based on the present measurements, defects smaller than approximately 1 cm did not produce a meaningful increase in air-kerma values under the tested conditions.
- 22 July 2026
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 46 (3) , 031519
Open AccessEffect of radiation protection apron defect on radiation dose during fluoroscopy
Occupational exposure should be minimised to a level that is as low as reasonably achievable. Radiation protection aprons and thyroid collars are effective in reducing occupational radiation dose as they typically attenuate at least 90% of scattered radiation. However, cracks and holes may compromise the shielding capacity of the apron. The aim of the study was to quantify change in radiation dose behind defects to support the development of rejection criteria for damaged aprons. Air kerma rates were measured with a calibrated solid‐state dosimeter behind a 0.25 mm Pb‐equivalent apron containing seven circular defects (diameter 1.5–20 mm) and one horizontal crack (50 mm) under two clinical fluoroscopy settings and compared with measurements obtained behind an intact apron. The air kerma rate increased by up to 165 µ Gy h −1 behind the damaged apron. Based on average annual fluoroscopy times per operator at Kuopio University Hospital, the use of damaged apron could result in an annual air kerma increase of 9.7 mGy behind the damaged area. Defect size and location affect the shielding performance of protective aprons. Considering defect position in rejection criteria allows more realistic estimation of the potential impact on staff effective dose and helps avoid unnecessary replacement of protective garments. Based on the present measurements, defects smaller than approximately 1 cm did not produce a meaningful increase in air-kerma values under the tested conditions.
- Open Access
- 1 June 2026
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 46 (2) , 021529
Dosimetric assessment of fetal radiation dose in clinical mammography
Objective . We quantify fetal radiation exposure from standard clinical mammography protocols and assess whether routine pregnancy verification is necessary before clinically indicated mammography. Approach . Measurements were performed on a Hologic Selenia Dimensions system using an Alderson Rando Female anthropomorphic phantom with tissue-equivalent breast slabs. Standard craniocaudal (CC) 2D mammography and tomosynthesis were acquired for two compressed breast thicknesses and four sets of imaging parameters. Air kerma was measured with a calibrated RaySafe Xi Survey detector at representative locations corresponding to the first, second and third trimesters; each configuration was repeated three times and a single configuration was repeated after fully rebuilding the setup to estimate positioning-related variability. Main results Mean measured fetal doses were 0.048 μ Gy–0.264 μ Gy (first trimester), 0.017 μ Gy–0.084 μ Gy (second trimester) and 0.753 μ Gy–7.253 μ Gy (third trimester). Across protocols, CC projections yielded 0.017 μ Gy–2.462 μ Gy and tomosynthesis 0.037 μ Gy–7.253 μ Gy. Dose increased with breast thickness and was highest in the third trimester, consistent with increased scatter and shorter path to the fetus. Between-setup variability for the rebuilt configuration was 36.2%. Significance . Fetal dose from mammography was several orders of magnitude below thresholds associated with deterministic fetal effects and the highest measured values remain far below levels that can be considered clinically significant. These findings suggest that clinically indicated mammography should not generally be delayed solely on the basis of pregnancy status, while recognising that decisions must follow local guidelines, institutional or national policies and individual risk considerations. Routine pregnancy screening prior to mammography is unlikely to provide meaningful clinical benefit in the context of radiation safety.
- 1 June 2026
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 46 (2) , 021529
Open AccessDosimetric assessment of fetal radiation dose in clinical mammography
Objective . We quantify fetal radiation exposure from standard clinical mammography protocols and assess whether routine pregnancy verification is necessary before clinically indicated mammography. Approach . Measurements were performed on a Hologic Selenia Dimensions system using an Alderson Rando Female anthropomorphic phantom with tissue-equivalent breast slabs. Standard craniocaudal (CC) 2D mammography and tomosynthesis were acquired for two compressed breast thicknesses and four sets of imaging parameters. Air kerma was measured with a calibrated RaySafe Xi Survey detector at representative locations corresponding to the first, second and third trimesters; each configuration was repeated three times and a single configuration was repeated after fully rebuilding the setup to estimate positioning-related variability. Main results Mean measured fetal doses were 0.048 μ Gy–0.264 μ Gy (first trimester), 0.017 μ Gy–0.084 μ Gy (second trimester) and 0.753 μ Gy–7.253 μ Gy (third trimester). Across protocols, CC projections yielded 0.017 μ Gy–2.462 μ Gy and tomosynthesis 0.037 μ Gy–7.253 μ Gy. Dose increased with breast thickness and was highest in the third trimester, consistent with increased scatter and shorter path to the fetus. Between-setup variability for the rebuilt configuration was 36.2%. Significance . Fetal dose from mammography was several orders of magnitude below thresholds associated with deterministic fetal effects and the highest measured values remain far below levels that can be considered clinically significant. These findings suggest that clinically indicated mammography should not generally be delayed solely on the basis of pregnancy status, while recognising that decisions must follow local guidelines, institutional or national policies and individual risk considerations. Routine pregnancy screening prior to mammography is unlikely to provide meaningful clinical benefit in the context of radiation safety.
- Open Access
- 26 August 2025
- Published by Elsevier in Physica Medica
- Vol. 137, 105082
Foetal dose in novel full body cone beam computed tomography device
- 26 August 2025
- Published by Elsevier in Physica Medica
- Vol. 137, 105082
Open AccessFoetal dose in novel full body cone beam computed tomography device
- Open Access
- 21 December 2020
- Published by Springer Nature in European Radiology
- Vol. 31 (6) , 4377-4385
Operator’s eye lens dose in computed tomography–guided interventions
Objectives: To survey (1) operator’s eye lens doses in typical computed tomography (CT)-guided interventions, (2) correlation between dose length product (DLP) and the operator’s dose, and (3) different ways for estimating the eye lens dose in clinical settings. Methods: Doses of 16 radiologists in 164 CT-guided interventional procedures were prospectively measured during a 6-month time period upon radioprotective garments and descriptive statistical outcomes were calculated. The correlations between DLP and measured doses were surveyed. Results: On average, the operator’s dose at the eye level (DEL, Hp(0.07)) was 22 μSv per procedure and the personal equivalent dose Hp(10) at the collar level was 21 μSv per procedure. The mean DLP of a procedure was 320 mGy cm, where 54% resulted from the fluoroscopy, the mean exposure time being 18 s. Based on the results, the operator’s DEL could be estimated from DLP using the equation DEL (μSv) = 0.10 μSv/mGy cm × patient fluoro DLP (mGycm) (p < 0.001), and the dose at the collar level (DCL) using the equation DCL (μSv) = 0.12 μSv/mGy cm × patient fluoro DLP (mGy cm) (p < 0.001). In addition, DEL (μSv) = 0.7 × DCL (μSv). Conclusions: The eye lens doses in CT-guided interventions are generally low even without protective equipment, and it is unlikely that the recommended annual equivalent dose limit of 20 mSv for the lens of the eye will be exceeded by conducting CT-guided interventions solely. Eye lens dose can be roughly estimated based on either DLP of the procedure or dose measured at the operator’s collar level. Key Points: • Eye lens doses in CT-guided operations are generally low. • It is unlikely that the ICRP recommendation of the yearly equivalent dose limit of 20 mSv will be exceeded by conducting CT-guided interventions solely. • Magnitude of eye lens dose can be estimated based on either DLP of the procedure or dose measured at the operator’s collar level.
- 21 December 2020
- Published by Springer Nature in European Radiology
- Vol. 31 (6) , 4377-4385
Open AccessOperator’s eye lens dose in computed tomography–guided interventions
Objectives: To survey (1) operator’s eye lens doses in typical computed tomography (CT)-guided interventions, (2) correlation between dose length product (DLP) and the operator’s dose, and (3) different ways for estimating the eye lens dose in clinical settings. Methods: Doses of 16 radiologists in 164 CT-guided interventional procedures were prospectively measured during a 6-month time period upon radioprotective garments and descriptive statistical outcomes were calculated. The correlations between DLP and measured doses were surveyed. Results: On average, the operator’s dose at the eye level (DEL, Hp(0.07)) was 22 μSv per procedure and the personal equivalent dose Hp(10) at the collar level was 21 μSv per procedure. The mean DLP of a procedure was 320 mGy cm, where 54% resulted from the fluoroscopy, the mean exposure time being 18 s. Based on the results, the operator’s DEL could be estimated from DLP using the equation DEL (μSv) = 0.10 μSv/mGy cm × patient fluoro DLP (mGycm) (p < 0.001), and the dose at the collar level (DCL) using the equation DCL (μSv) = 0.12 μSv/mGy cm × patient fluoro DLP (mGy cm) (p < 0.001). In addition, DEL (μSv) = 0.7 × DCL (μSv). Conclusions: The eye lens doses in CT-guided interventions are generally low even without protective equipment, and it is unlikely that the recommended annual equivalent dose limit of 20 mSv for the lens of the eye will be exceeded by conducting CT-guided interventions solely. Eye lens dose can be roughly estimated based on either DLP of the procedure or dose measured at the operator’s collar level. Key Points: • Eye lens doses in CT-guided operations are generally low. • It is unlikely that the ICRP recommendation of the yearly equivalent dose limit of 20 mSv will be exceeded by conducting CT-guided interventions solely. • Magnitude of eye lens dose can be estimated based on either DLP of the procedure or dose measured at the operator’s collar level.