Ari-Petteri Ronkainen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Ari-Petteri Ronkainen has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Mimmi K. Liukkonen
Kuopio University Hospital
3 shared publications - Siru Kaartinen
Kuopio University Hospital, Wellbeing Services County of North Savo
2 shared publications Ali Al-Gburi
Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland
1 shared publication- Hanna Matikka
Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland
1 shared publication Hedman M
Institute of Medicine University of Eastern Finland Kuopio Finland
1 shared publication- James M. Fick
Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
1 shared publication
Latest Publications
- Open Access
- 30 October 2026
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 46 (6)
15 O‐water PET‐detected myocardial ischaemia and CT‐derived FFR: Predicting the functional significance of anatomical stenosis
Aims: Coronary artery disease (CAD) is a major cause of morbidity and mortality worldwide. While coronary computed tomography angiography (CCTA) provides anatomical assessment of coronary stenoses, its ability to determine their functional significance is limited. Computed tomography‐derived fractional flow reserve (CT‐FFR) has emerged as a non‐invasive method for lesion‐specific ischaemia assessment. This study evaluated the diagnostic performance of CT‐FFR using 15 O‐water positron emission tomography (PET) myocardial perfusion imaging as the reference standard. Methods and Results: We retrospectively reviewed 193 patients who underwent hybrid CCTA and 15 O‐water PET at Kuopio University Hospital between 2017 and 2022. Patients with low‐to‐moderate pretest probability of CAD in whom CAD could not be ruled out by CCTA were eligible. After exclusions, 165 patients were included. CT‐FFR values were calculated using a research prototype algorithm and compared with PET‐derived perfusion abnormalities. In the overall cohort, CT‐FFR showed moderate diagnostic performance, with area under the curve (AUC) values of 0.672–0.740. In a subgroup of 83 patients with high‐quality CCTA and stenosis >50%, diagnostic performance improved substantially (AUC 0.836). Using a CT‐FFR threshold of 0.80, sensitivity and specificity were 85% and 87%, respectively. Conclusion: In an unselected clinical population referred for PET perfusion imaging after CCTA, CT‐FFR did not significantly improve diagnostic performance compared with CCTA alone. However, in patients with high‐quality CCTA and obstructive coronary stenoses, CT‐FFR demonstrated good accuracy for identifying functionally significant disease, supporting its role as a complementary non‐invasive diagnostic tool.
- 30 October 2026
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 46 (6)
Open Access15 O‐water PET‐detected myocardial ischaemia and CT‐derived FFR: Predicting the functional significance of anatomical stenosis
Aims: Coronary artery disease (CAD) is a major cause of morbidity and mortality worldwide. While coronary computed tomography angiography (CCTA) provides anatomical assessment of coronary stenoses, its ability to determine their functional significance is limited. Computed tomography‐derived fractional flow reserve (CT‐FFR) has emerged as a non‐invasive method for lesion‐specific ischaemia assessment. This study evaluated the diagnostic performance of CT‐FFR using 15 O‐water positron emission tomography (PET) myocardial perfusion imaging as the reference standard. Methods and Results: We retrospectively reviewed 193 patients who underwent hybrid CCTA and 15 O‐water PET at Kuopio University Hospital between 2017 and 2022. Patients with low‐to‐moderate pretest probability of CAD in whom CAD could not be ruled out by CCTA were eligible. After exclusions, 165 patients were included. CT‐FFR values were calculated using a research prototype algorithm and compared with PET‐derived perfusion abnormalities. In the overall cohort, CT‐FFR showed moderate diagnostic performance, with area under the curve (AUC) values of 0.672–0.740. In a subgroup of 83 patients with high‐quality CCTA and stenosis >50%, diagnostic performance improved substantially (AUC 0.836). Using a CT‐FFR threshold of 0.80, sensitivity and specificity were 85% and 87%, respectively. Conclusion: In an unselected clinical population referred for PET perfusion imaging after CCTA, CT‐FFR did not significantly improve diagnostic performance compared with CCTA alone. However, in patients with high‐quality CCTA and obstructive coronary stenoses, CT‐FFR demonstrated good accuracy for identifying functionally significant disease, supporting its role as a complementary non‐invasive diagnostic tool.
- Open Access
- 22 July 2026
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 46 (3) , 031519
Effect of radiation protection apron defect on radiation dose during fluoroscopy
Occupational exposure should be minimised to a level that is as low as reasonably achievable. Radiation protection aprons and thyroid collars are effective in reducing occupational radiation dose as they typically attenuate at least 90% of scattered radiation. However, cracks and holes may compromise the shielding capacity of the apron. The aim of the study was to quantify change in radiation dose behind defects to support the development of rejection criteria for damaged aprons. Air kerma rates were measured with a calibrated solid‐state dosimeter behind a 0.25 mm Pb‐equivalent apron containing seven circular defects (diameter 1.5–20 mm) and one horizontal crack (50 mm) under two clinical fluoroscopy settings and compared with measurements obtained behind an intact apron. The air kerma rate increased by up to 165 µ Gy h −1 behind the damaged apron. Based on average annual fluoroscopy times per operator at Kuopio University Hospital, the use of damaged apron could result in an annual air kerma increase of 9.7 mGy behind the damaged area. Defect size and location affect the shielding performance of protective aprons. Considering defect position in rejection criteria allows more realistic estimation of the potential impact on staff effective dose and helps avoid unnecessary replacement of protective garments. Based on the present measurements, defects smaller than approximately 1 cm did not produce a meaningful increase in air-kerma values under the tested conditions.
- 22 July 2026
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 46 (3) , 031519
Open AccessEffect of radiation protection apron defect on radiation dose during fluoroscopy
Occupational exposure should be minimised to a level that is as low as reasonably achievable. Radiation protection aprons and thyroid collars are effective in reducing occupational radiation dose as they typically attenuate at least 90% of scattered radiation. However, cracks and holes may compromise the shielding capacity of the apron. The aim of the study was to quantify change in radiation dose behind defects to support the development of rejection criteria for damaged aprons. Air kerma rates were measured with a calibrated solid‐state dosimeter behind a 0.25 mm Pb‐equivalent apron containing seven circular defects (diameter 1.5–20 mm) and one horizontal crack (50 mm) under two clinical fluoroscopy settings and compared with measurements obtained behind an intact apron. The air kerma rate increased by up to 165 µ Gy h −1 behind the damaged apron. Based on average annual fluoroscopy times per operator at Kuopio University Hospital, the use of damaged apron could result in an annual air kerma increase of 9.7 mGy behind the damaged area. Defect size and location affect the shielding performance of protective aprons. Considering defect position in rejection criteria allows more realistic estimation of the potential impact on staff effective dose and helps avoid unnecessary replacement of protective garments. Based on the present measurements, defects smaller than approximately 1 cm did not produce a meaningful increase in air-kerma values under the tested conditions.
- Open Access
- 3 June 2026
- Published by Elsevier in Radiography
- Vol. 32 (5) , 103461
Optimizing CT pulmonary angiography: Manual versus automatic kVp selection
- 3 June 2026
- Published by Elsevier in Radiography
- Vol. 32 (5) , 103461
Open AccessOptimizing CT pulmonary angiography: Manual versus automatic kVp selection
- Open Access
- 1 June 2026
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 46 (2) , 021529
Dosimetric assessment of fetal radiation dose in clinical mammography
Objective . We quantify fetal radiation exposure from standard clinical mammography protocols and assess whether routine pregnancy verification is necessary before clinically indicated mammography. Approach . Measurements were performed on a Hologic Selenia Dimensions system using an Alderson Rando Female anthropomorphic phantom with tissue-equivalent breast slabs. Standard craniocaudal (CC) 2D mammography and tomosynthesis were acquired for two compressed breast thicknesses and four sets of imaging parameters. Air kerma was measured with a calibrated RaySafe Xi Survey detector at representative locations corresponding to the first, second and third trimesters; each configuration was repeated three times and a single configuration was repeated after fully rebuilding the setup to estimate positioning-related variability. Main results Mean measured fetal doses were 0.048 μ Gy–0.264 μ Gy (first trimester), 0.017 μ Gy–0.084 μ Gy (second trimester) and 0.753 μ Gy–7.253 μ Gy (third trimester). Across protocols, CC projections yielded 0.017 μ Gy–2.462 μ Gy and tomosynthesis 0.037 μ Gy–7.253 μ Gy. Dose increased with breast thickness and was highest in the third trimester, consistent with increased scatter and shorter path to the fetus. Between-setup variability for the rebuilt configuration was 36.2%. Significance . Fetal dose from mammography was several orders of magnitude below thresholds associated with deterministic fetal effects and the highest measured values remain far below levels that can be considered clinically significant. These findings suggest that clinically indicated mammography should not generally be delayed solely on the basis of pregnancy status, while recognising that decisions must follow local guidelines, institutional or national policies and individual risk considerations. Routine pregnancy screening prior to mammography is unlikely to provide meaningful clinical benefit in the context of radiation safety.
- 1 June 2026
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 46 (2) , 021529
Open AccessDosimetric assessment of fetal radiation dose in clinical mammography
Objective . We quantify fetal radiation exposure from standard clinical mammography protocols and assess whether routine pregnancy verification is necessary before clinically indicated mammography. Approach . Measurements were performed on a Hologic Selenia Dimensions system using an Alderson Rando Female anthropomorphic phantom with tissue-equivalent breast slabs. Standard craniocaudal (CC) 2D mammography and tomosynthesis were acquired for two compressed breast thicknesses and four sets of imaging parameters. Air kerma was measured with a calibrated RaySafe Xi Survey detector at representative locations corresponding to the first, second and third trimesters; each configuration was repeated three times and a single configuration was repeated after fully rebuilding the setup to estimate positioning-related variability. Main results Mean measured fetal doses were 0.048 μ Gy–0.264 μ Gy (first trimester), 0.017 μ Gy–0.084 μ Gy (second trimester) and 0.753 μ Gy–7.253 μ Gy (third trimester). Across protocols, CC projections yielded 0.017 μ Gy–2.462 μ Gy and tomosynthesis 0.037 μ Gy–7.253 μ Gy. Dose increased with breast thickness and was highest in the third trimester, consistent with increased scatter and shorter path to the fetus. Between-setup variability for the rebuilt configuration was 36.2%. Significance . Fetal dose from mammography was several orders of magnitude below thresholds associated with deterministic fetal effects and the highest measured values remain far below levels that can be considered clinically significant. These findings suggest that clinically indicated mammography should not generally be delayed solely on the basis of pregnancy status, while recognising that decisions must follow local guidelines, institutional or national policies and individual risk considerations. Routine pregnancy screening prior to mammography is unlikely to provide meaningful clinical benefit in the context of radiation safety.
- Open Access
- 27 January 2022
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 279 (9) , 4407-4414
A dose–neutral image quality comparison of different CBCT and CT systems using paranasal sinus imaging protocols and phantoms
Purpose: To compare the image quality produced by equivalent low-dose and default sinus imaging protocols of a conventional dental cone-beam computed tomography (CBCT) scanner, an extremity CBCT scanner and a clinical multidetector computed tomography (MDCT) scanner. Methods: Three different phantoms were scanned using dose–neutral ultra-low-dose and low-dose sinus imaging protocols, as well as default sinus protocols of each device. Quantified parameters of image quality included modulation transfer function (MTF) to characterize the spatial response of the imaging system, contrast-to-noise ratio, low contrast visibility, image uniformity and Hounsfield unit accuracy. MTF was calculated using the line spread and edge spread functions (LSF and ESF). Results: The dental CBCT had superior performance over the extremity CBCT in each studied parameter at similar dose levels. The MDCT had better contrast-to-noise ratio, low contrast visibility and image uniformity than the CBCT scanners. However, the CBCT scanners had better resolution compared to the MDCT. Accuracy of HU values for different materials was on the same level between the dental CBCT and MDCT, but substantially poorer performance was observed with the extremity CBCT. Conclusions: The studied dental CBCT scanner showed superior performance over the studied extremity CBCT scanner when using dose–neutral imaging protocols. In case a dental CBCT is not available, the given extremity CBCT is still a viable option as it provides the benefit of high resolution over a conventional MDCT.
- 27 January 2022
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 279 (9) , 4407-4414
Open AccessA dose–neutral image quality comparison of different CBCT and CT systems using paranasal sinus imaging protocols and phantoms
Purpose: To compare the image quality produced by equivalent low-dose and default sinus imaging protocols of a conventional dental cone-beam computed tomography (CBCT) scanner, an extremity CBCT scanner and a clinical multidetector computed tomography (MDCT) scanner. Methods: Three different phantoms were scanned using dose–neutral ultra-low-dose and low-dose sinus imaging protocols, as well as default sinus protocols of each device. Quantified parameters of image quality included modulation transfer function (MTF) to characterize the spatial response of the imaging system, contrast-to-noise ratio, low contrast visibility, image uniformity and Hounsfield unit accuracy. MTF was calculated using the line spread and edge spread functions (LSF and ESF). Results: The dental CBCT had superior performance over the extremity CBCT in each studied parameter at similar dose levels. The MDCT had better contrast-to-noise ratio, low contrast visibility and image uniformity than the CBCT scanners. However, the CBCT scanners had better resolution compared to the MDCT. Accuracy of HU values for different materials was on the same level between the dental CBCT and MDCT, but substantially poorer performance was observed with the extremity CBCT. Conclusions: The studied dental CBCT scanner showed superior performance over the studied extremity CBCT scanner when using dose–neutral imaging protocols. In case a dental CBCT is not available, the given extremity CBCT is still a viable option as it provides the benefit of high resolution over a conventional MDCT.
- 1 November 2015
- Published by Elsevier in Journal of Biomechanics
- Vol. 48 (15) , 4010-4019
Site-dependent biomechanical responses of chondrocytes in the rabbit knee joint
- 1 November 2015
- Published by Elsevier in Journal of Biomechanics
- Vol. 48 (15) , 4010-4019
Site-dependent biomechanical responses of chondrocytes in the rabbit knee joint