KSKlaus-Peter Schmitz

Klaus-Peter Schmitz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Klaus-Peter Schmitz has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development of a standardized intracranial vessel model from 3D time-of-flight magnetic resonance angiography data of the SHIP cohort

    by Antonia Dalmer, Stefan Siewert, Dominique Passler, Hagen Paetow, Christoph Brandt-Wunderlich, Daniel Cantré, Ebba Beller, Sönke Langner, Klaus-Peter Schmitz, Marc-André Weber, et al.

    Purpose: A standardized, population-based three-dimensional (3D) computer-aided design (CAD) model of the intracranial arterial system was developed from time-of-flight magnetic resonance angiography (TOF-MRA) data of the Study of Health in Pomerania (SHIP) cohort, tailored for realistic simulation and experimental neurovascular applications. Methods: An averaged intracranial TOF-MRA dataset generated from 4308 individual whole-body MRI examinations of the SHIP cohort was used as the anatomical basis. Intracranial arteries were segmented using 3D Slicer with Frangi-based vessel enhancement, semi-automatic region-growing, and manual refinement to obtain continuous vascular masks. Centerlines were extracted with VMTK (Vascular Modelling Toolkit) , and vessel radii were computed via distance mapping. The resulting centerline and radius data were imported into a CAD environment ( Creo Parametric ) to reconstruct smooth vessel centerlines, generate circular cross-sections, and create a lofted three-dimensional lumen model, which was converted into a hollow geometry with a uniform wall thickness and exported as an STL file for 3D printing. Results: The proposed workflow yielded a geometrically consistent, hollow 3D model of the central intracranial arteries, representing a population-averaged arterial anatomy with smooth vessel courses, gradual diameter transitions, and a closed, continuous wall. The CAD model could be successfully manufactured as a physical 3D-printed phantom and provides a stable, reproducible test environment for digital and in vitro investigations of neurovascular interventions under standardized anatomical conditions. Conclusions: Population-based TOF-MRA data can be transformed into a technically robust and anatomically meaningful intracranial reference model suitable for CAD-based simulation and additive manufacturing. The resulting 3D CAD geometry serves as a reusable reference for comparative studies, methodological validation, early-stage device development, and training in endovascular neurosurgery, without aiming to replace patient-specific models.

  • Open Access

    Analysis of thrombosis risk of commissural misaligned transcatheter aortic valve prostheses using particle image velocimetry

    by Finja Borowski, Sebastian Kaule, Jan Oldenburg, Klaus-Peter Schmitz, Alper Öner, Michael Stiehm

    Due to excellent clinical results, transcatheter aortic valve replacement (TAVR) has evolved to a treatment option for patients with low surgical risk, resulting in an increasing demand for durable heart valve prostheses. Durability of TAVR could be limited by leaflet thrombosis. Thrombus formation in the aortic root is mainly affected by the hemodynamic situation, which is dependent on the positioning of the implant. We investigated the flow field in the aortic root after TAVR implantation by means of particle image velocimetry. To quantify the influence of the implant-position with respect to an alignment or misalignment of the leaflet commissures on the thrombogenic potential, we used a transport equation for residence time (RT) to consider washout behavior. Furthermore, we introduced a shear effect criterion (SIE) to address platelet activation as a measure for a potential thrombus formation. Misaligned implantation of a TAVR resulted in a reversed direction of rotation of the occurring recirculation area. This led to fluid flow with comparable areas of increased relative blood RT (RTaligned: 97.6%, RTmisaligned: 88.0%) and a smaller area of low shear load for the misaligned TAVR (SIEaligned: 57.7%, SIEmisaligned: 3.70%) into the sinus region, indicating a higher potential for thrombus formation.


  • Open Access

    Analysis on the effects of hypo-attenuated leaflet thickening on the hemodynamics of transcatheter aortic valve prostheses by means of particle image velocimetry

    by Jan Oldenburg, Finja Borowski, Sebastian Kaule, Klaus-Peter Schmitz, Alper Öner, Michael Stiehm

    The minimally invasive therapy for the treatment of aortic valve regurgitation and stenosis, transcatheter aortic valve replacement (TAVR), is an alternative to surgical valve replacement. Promising clinical results led to the consideration of expanding the use of TAVR in younger patients with lower surgical risk. This implies a longer durability of the TAVR. In relation to the durability of the TAVR, thickening of TAVR leaflets, including reduced motion, has been clinically observed. The aim of this study was to analyse the effects of valve leaflet thickening with reduced leaflet kinematics on the hemodynamics. We measured the flow through a TAVR under pulsatile conditions by using phase-resolved particle image velocimetry (PIV). It has been shown that flow conditions alter in a pathological manner in a TAVR replica with thickened leaflets compared with thin leaflets. In detail, shear stress and Reynolds stress increased by up to a factor of two and additionally the washout behaviour was worse for thickened leaflets. This suggests that a thickened valve is at higher risk for platelet activation and aggregation. This could lead to a self-reinforcing process in which the formation of a thickened valve promotes thrombus formation, which in turn promotes further progression of the thickening.


  • Open Access

    Accelerated Endothelialization of Nanofibrous Scaffolds for Biomimetic Cardiovascular Implants

    by Claudia Matschegewski, Stefanie Kohse, Jana Markhoff, Michael Teske, Katharina Wulf, Niels Grabow, Klaus-Peter Schmitz, Sabine Illner

    Nanofiber nonwovens are highly promising to serve as biomimetic scaffolds for pioneering cardiac implants such as drug-eluting stent systems or heart valve prosthetics. For successful implant integration, rapid and homogeneous endothelialization is of utmost importance as it forms a hemocompatible surface. This study aims at physicochemical and biological evaluation of various electrospun polymer scaffolds, made of FDA approved medical-grade plastics. Human endothelial cells (EA.hy926) were examined for cell attachment, morphology, viability, as well as actin and PECAM 1 expression. The appraisal of the untreated poly-L-lactide (PLLA L210), poly-ε-caprolactone (PCL) and polyamide-6 (PA-6) nonwovens shows that the hydrophilicity (water contact angle > 80°) and surface free energy (3-plasma surface functionalization resulted in a more physiological localization of cell–cell contact markers, promoting endothelialization on all polymeric surfaces, while fiber diameter remained unaltered. Our data indicates that hydrophobic nonwovens are often insufficient to mimic the native extracellular matrix but also that they can be easily adapted by targeted post-processing steps such as plasma treatment. The results achieved increase the understanding of cell–implant interactions of nanostructured polymer-based biomaterial surfaces in blood contact while also advocating for plasma technology to increase the surface energy of nonpolar biostable, as well as biodegradable polymer scaffolds. Thus, we highlight the potential of plasma-activated electrospun polymer scaffolds for the development of advanced cardiac implants.


  • Open Access

    Particle-Image-Velocimetry zur strömungsmechanischen Analyse des thrombogenen Potentials von Transkatheter-Aortenklappenprothesen

    by Finja Borowski, Sebastian Kaule, Jan Oldenburg, Klaus-Peter Schmitz, Alper Öner, Michael Stiehm

    Zusammenfassung Die minimalinvasive Implantation einer Transkatheter-Aortenklappenprothese (TAVR) hat sich zur Standardtherapie für Patienten mit schwerer Aortenklappenstenose und erhöhtem Operationsrisiko etabliert. Postoperative Komplikationen, wie die subklinische Klappenthrombose, rufen langfristig eine Funktionsstörung der TAVR hervor, die ohne Revisionstherapie zum Tod des Patienten führen kann. Mit der Abschätzung des Thromboserisikos von TAVR werden strömungsmechanische Mechanismen assoziiert. Die Particle Image Velocimetry (PIV) bietet ein etabliertes Messverfahren zur Bestimmung des Geschwindigkeitsfeldes einer TAVR, aus dem beispielsweise die Verweilzeit von Blut im Umfeld einer TAVR abgeleitet werden kann. Ein traversierbarer stereo-PIV Aufbau, bei dem zwei CMOS-Kameras im 45 ° Winkel zur Lichtschnittebene positioniert wurden, ermöglichte die Detektion von Tracerpartikeln in den relevanten Bereichen im Umfeld des TAVR. Mit einer geeigneten Messkammer, die in die hydraulische Nachbildung eines kardiovaskulären Kreislaufs implementiert wurde, konnte eine quasi-volumetrische Messung des physiologischen Geschwindigkeitsfeldes durchgeführt werden. Dafür wurde anhand radiologischer Daten eine realistische Implantationsumgebung rekonstruiert. Mit einem Blutersatzfluid (NaCl-Glycerin-Gemisch) wurde die normativ (ISO 5840:2021) geforderte kinematische Viskosität von ν = 3,5 cSt realisiert. Phasengetriggerte Aufnahmen ermöglichten die Messung zu definierten Zeitpunkten im kardiologischen Zyklus. Insgesamt ist es gelungen die komplexe Strömungstopologie mit dem dargestellten Messaufbau in allen relevanten Bereichen zu erfassen und damit zukünftig das Thromboserisiko abschätzen zu können.


  • Open Access

    Influence of Drug Incorporation on the Physico-Chemical Properties of Poly(l-Lactide) Implant Coating Matrices—A Systematic Study

    by Daniela Arbeiter, Thomas Reske, Michael Teske, Dalibor Bajer, Volkmar Senz, Klaus-Peter Schmitz, Niels Grabow, Stefan Oschatz

    Local drug delivery has become indispensable in biomedical engineering with stents being ideal carrier platforms. While local drug release is superior to systemic administration in many fields, the incorporation of drugs into polymers may influence the physico-chemical properties of said matrix. This is of particular relevance as minimally invasive implantation is frequently accompanied by mechanical stresses on the implant and coating. Thus, drug incorporation into polymers may result in a susceptibility to potentially life-threatening implant failure. We investigated spray-coated poly-l-lactide (PLLA)/drug blends using thermal measurements (DSC) and tensile tests to determine the influence of selected drugs, namely sirolimus, paclitaxel, dexamethasone, and cyclosporine A, on the physico-chemical properties of the polymer. For all drugs and PLLA/drug ratios, an increase in tensile strength was observed. As for sirolimus and dexamethasone, PLLA/drug mixed phase systems were identified by shifted drug melting peaks at 200 °C and 240 °C, respectively, whereas paclitaxel and dexamethasone led to cold crystallization. Cyclosporine A did not affect matrix thermal properties. Altogether, our data provide a contribution towards an understanding of the complex interaction between PLLA and different drugs. Our results hold implications regarding the necessity of target-oriented thermal treatment to ensure the shelf life and performance of stent coatings.